Compare commits
5 Commits
s-allius/i
...
support-nu
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
b16a4ad549 | ||
|
|
af5604d029 | ||
|
|
015b6b8db0 | ||
|
|
7782a3cb57 | ||
|
|
3d073acc58 |
11
app/Makefile
11
app/Makefile
@@ -22,7 +22,16 @@ dev debug:
|
||||
export IMAGE=$(PRIVAT_CONTAINER_REGISTRY)$(IMAGE) && \
|
||||
docker buildx bake -f docker-bake.hcl $@
|
||||
|
||||
preview rc rel:
|
||||
rc:
|
||||
@[ "${RC}" ] || ( echo ">> RC is not set"; exit 1 )
|
||||
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
|
||||
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
|
||||
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
|
||||
export VERSION=$(VERSION)-$@$(RC) && \
|
||||
export IMAGE=$(PUBLIC_CONTAINER_REGISTRY)$(IMAGE) && \
|
||||
docker buildx bake -f docker-bake.hcl $@
|
||||
|
||||
preview rel:
|
||||
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
|
||||
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
|
||||
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
flake8==7.2.0
|
||||
pytest==8.3.5
|
||||
pytest-asyncio==0.26.0
|
||||
pytest-cov==6.1.0
|
||||
pytest-cov==6.1.1
|
||||
python-dotenv==1.1.0
|
||||
mock==5.2.0
|
||||
coverage==7.8.0
|
||||
|
||||
@@ -19,6 +19,19 @@ class RegisterFunc:
|
||||
result += prod
|
||||
return result
|
||||
|
||||
@staticmethod
|
||||
def cmp_values(info: Infos, params: map) -> None | int:
|
||||
try:
|
||||
val = info.get_db_value(params['reg'])
|
||||
if val < params['cmp_val']:
|
||||
return params['res'][0]
|
||||
if val == params['cmp_val']:
|
||||
return params['res'][1]
|
||||
return params['res'][2]
|
||||
except Exception:
|
||||
pass
|
||||
return None
|
||||
|
||||
|
||||
class RegisterMap:
|
||||
# make the class read/only by using __slots__
|
||||
@@ -136,8 +149,8 @@ class RegisterMap:
|
||||
0x42010034: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Voltage PV2
|
||||
0x42010036: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Current PV2
|
||||
0x42010038: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
|
||||
0x4201003c: {'reg': Register.BATT_STATUS_1, 'fmt': '!H'}, # noqa: E501 MPTT-1 Operating Status: 0(Standby), 1(Work)
|
||||
0x4201003e: {'reg': Register.BATT_STATUS_2, 'fmt': '!H'}, # noqa: E501 MPTT-2 Operating Status: 0(Standby), 1(Work)
|
||||
0x4201003c: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-1 Operating Status: 0(Standby), 1(Work)
|
||||
0x4201003e: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-2 Operating Status: 0(Standby), 1(Work)
|
||||
0x42010040: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x42010042: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501 => Batterie Status: <0(Discharging), 0(Static), 0>(Loading)
|
||||
0x42010044: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
|
||||
@@ -164,7 +177,7 @@ class RegisterMap:
|
||||
0x4201006e: {'reg': Register.BATT_OUT_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 Output Current
|
||||
0x42010070: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!H'}, # noqa: E501 Output Working Status: 0(Standby), 1(Work)
|
||||
0x42010072: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E50, Environment temp
|
||||
0x42010074: {'reg': Register.BATT_74, 'fmt': '!H'}, # noqa: E501 Warning Alarmcode 1, Bit 0..15
|
||||
0x42010074: {'reg': Register.BATT_ALARM, 'fmt': '!H'}, # noqa: E501 Warning Alarmcode 1, Bit 0..15
|
||||
0x42010076: {'reg': Register.BATT_HW_VERS, 'fmt': '!h'}, # noqa: E501 hardware version
|
||||
0x42010078: {'reg': Register.BATT_SW_VERS, 'fmt': '!h'}, # noqa: E501 software main version
|
||||
'calc': {
|
||||
@@ -173,8 +186,12 @@ class RegisterMap:
|
||||
[Register.BATT_PV2_VOLT, Register.BATT_PV2_CUR]]},
|
||||
2: {'reg': Register.BATT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
|
||||
'params': [[Register.BATT_VOLT, Register.BATT_CUR]]},
|
||||
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Supply Power => Power Supply State: 0(Idle), 0>(Power Supply)
|
||||
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Supply Power => Power Supply State: 0(Idle), 0>(Power Supply)
|
||||
'params': [[Register.BATT_OUT_VOLT, Register.BATT_OUT_CUR]]},
|
||||
4: {'reg': Register.BATT_PWR_SUPL_STATE, 'func': RegisterFunc.cmp_values, # noqa: E501
|
||||
'params': {'reg': Register.BATT_OUT_PWR, 'cmp_val': 0, 'res': [0, 0, 1]}}, # noqa: E501
|
||||
5: {'reg': Register.BATT_STATUS, 'func': RegisterFunc.cmp_values, # noqa: E501
|
||||
'params': {'reg': Register.BATT_CUR, 'cmp_val': 0.0, 'res': [0, 1, 2]}} # noqa: E501
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
149
app/src/infos.py
149
app/src/infos.py
@@ -126,8 +126,8 @@ class Register(Enum):
|
||||
BATT_PV2_VOLT = 1002
|
||||
BATT_PV2_CUR = 1003
|
||||
BATT_TOTAL_CHARG = 1005
|
||||
BATT_STATUS_1 = 1006
|
||||
BATT_STATUS_2 = 1007
|
||||
BATT_PV1_STATUS = 1006
|
||||
BATT_PV2_STATUS = 1007
|
||||
BATT_VOLT = 1010
|
||||
BATT_CUR = 1011
|
||||
BATT_SOC = 1012
|
||||
@@ -154,12 +154,14 @@ class Register(Enum):
|
||||
BATT_OUT_CUR = 1033
|
||||
BATT_OUT_STATUS = 1034
|
||||
BATT_TEMP_4 = 1035
|
||||
BATT_74 = 1036
|
||||
BATT_ALARM = 1036
|
||||
BATT_HW_VERS = 1037
|
||||
BATT_SW_VERS = 1038
|
||||
BATT_PV_PWR = 1040
|
||||
BATT_PWR = 1041
|
||||
BATT_OUT_PWR = 1042
|
||||
BATT_PWR_SUPL_STATE = 1043
|
||||
BATT_STATUS = 1044
|
||||
|
||||
TEST_VAL_0 = 2000
|
||||
TEST_VAL_1 = 2001
|
||||
@@ -324,6 +326,7 @@ class Infos:
|
||||
SOLAR_POWER_VAR = 'mdi:solar-power-variant'
|
||||
SOLAR_POWER = 'mdi:solar-power'
|
||||
WIFI = 'mdi:wifi'
|
||||
ALARM_LIGHT = 'mdi:alarm-light'
|
||||
UPDATE = 'mdi:update'
|
||||
DAILY_GEN = 'Daily Generation'
|
||||
TOTAL_GEN = 'Total Generation'
|
||||
@@ -377,6 +380,8 @@ class Infos:
|
||||
__status_type_val_tpl = "{%set inv_status = ['Off-line', 'On-grid', 'Off-grid'] %}{{inv_status[value_json['Inverter_Status']|int(0)]|default(value_json['Inverter_Status'])}}" # noqa: E501
|
||||
__mppt1_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv1']['MPPT-Status']|int(0)]|default(value_json['pv1']['MPPT-Status'])}}" # noqa: E501
|
||||
__mppt2_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv2']['MPPT-Status']|int(0)]|default(value_json['pv2']['MPPT-Status'])}}" # noqa: E501
|
||||
__supply_status_type_val_tpl = "{%set supply_status = ['Idle', 'Power-Supply'] %}{{supply_status[value_json['out']['Suppl_State']|int(0)]|default(value_json['out']['Suppl_State'])}}" # noqa: E501
|
||||
__batt_status_type_val_tpl = "{%set batt_status = ['Discharging', 'Static', 'Loading'] %}{{batt_status[value_json['batt']['Batt_State']|int(0)]|default(value_json['batt']['Batt_State'])}}" # noqa: E501
|
||||
__out_status_type_val_tpl = "{%set out_status = ['Standby', 'On'] %}{{out_status[value_json['out']['Out_Status']|int(0)]|default(value_json['out']['Out_Status'])}}" # noqa: E501
|
||||
__rated_power_val_tpl = "{% if 'Rated_Power' in value_json and value_json['Rated_Power'] != None %}{{value_json['Rated_Power']|string() +' W'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
|
||||
__designed_power_val_tpl = '''
|
||||
@@ -399,52 +404,52 @@ class Infos:
|
||||
{% set result = 'noAlarm'%}
|
||||
{%else%}
|
||||
{% set result = '' %}
|
||||
{% if val_int | bitwise_and(1)%}
|
||||
{% if val_int | bitwise_and(0x0001)%}
|
||||
{% set result = result + 'HBridgeFault, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(2)%}
|
||||
{% if val_int | bitwise_and(0x0002)%}
|
||||
{% set result = result + 'DriVoltageFault, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(3)%}
|
||||
{% if val_int | bitwise_and(0x0004)%}
|
||||
{% set result = result + 'GFDI-Fault, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(4)%}
|
||||
{% if val_int | bitwise_and(0x0008)%}
|
||||
{% set result = result + 'OverTemp, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(5)%}
|
||||
{% if val_int | bitwise_and(0x0010)%}
|
||||
{% set result = result + 'CommLose, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(6)%}
|
||||
{% if val_int | bitwise_and(0x0020)%}
|
||||
{% set result = result + 'Bit6, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(7)%}
|
||||
{% if val_int | bitwise_and(0x0040)%}
|
||||
{% set result = result + 'Bit7, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(8)%}
|
||||
{% if val_int | bitwise_and(0x0080)%}
|
||||
{% set result = result + 'EEPROM-Fault, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(9)%}
|
||||
{% if val_int | bitwise_and(0x0100)%}
|
||||
{% set result = result + 'NoUtility, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(10)%}
|
||||
{% if val_int | bitwise_and(0x0200)%}
|
||||
{% set result = result + 'VG_Offset, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(11)%}
|
||||
{% if val_int | bitwise_and(0x0400)%}
|
||||
{% set result = result + 'Relais_Open, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(12)%}
|
||||
{% if val_int | bitwise_and(0x0800)%}
|
||||
{% set result = result + 'Relais_Short, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(13)%}
|
||||
{% if val_int | bitwise_and(0x1000)%}
|
||||
{% set result = result + 'GridVoltOverRating, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(14)%}
|
||||
{% if val_int | bitwise_and(0x2000)%}
|
||||
{% set result = result + 'GridVoltUnderRating, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(15)%}
|
||||
{% if val_int | bitwise_and(0x4000)%}
|
||||
{% set result = result + 'GridFreqOverRating, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(16)%}
|
||||
{% if val_int | bitwise_and(0x8000)%}
|
||||
{% set result = result + 'GridFreqUnderRating, '%}
|
||||
{% endif %}
|
||||
{% endif %}
|
||||
@@ -461,42 +466,104 @@ class Infos:
|
||||
{% set result = 'noFault'%}
|
||||
{%else%}
|
||||
{% set result = '' %}
|
||||
{% if val_int | bitwise_and(1)%}
|
||||
{% if val_int | bitwise_and(0x0001)%}
|
||||
{% set result = result + 'PVOV-Fault (PV OverVolt), '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(2)%}
|
||||
{% if val_int | bitwise_and(0x0002)%}
|
||||
{% set result = result + 'PVLV-Fault (PV LowVolt), '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(3)%}
|
||||
{% if val_int | bitwise_and(0x0004)%}
|
||||
{% set result = result + 'PV OI-Fault (PV OverCurrent), '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(4)%}
|
||||
{% if val_int | bitwise_and(0x0008)%}
|
||||
{% set result = result + 'PV OFV-Fault, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(5)%}
|
||||
{% if val_int | bitwise_and(0x0010)%}
|
||||
{% set result = result + 'DC ShortCircuitFault, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(6)%}{% set result = result + 'Bit6, '%}
|
||||
{% if val_int | bitwise_and(0x0020)%}{% set result = result + 'Bit6, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(7)%}{% set result = result + 'Bit7, '%}
|
||||
{% if val_int | bitwise_and(0x0040)%}{% set result = result + 'Bit7, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(8)%}{% set result = result + 'Bit8, '%}
|
||||
{% if val_int | bitwise_and(0x0080)%}{% set result = result + 'Bit8, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(9)%}{% set result = result + 'Bit9, '%}
|
||||
{% if val_int | bitwise_and(0x0100)%}{% set result = result + 'Bit9, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(10)%}{% set result = result + 'Bit10, '%}
|
||||
{% if val_int | bitwise_and(0x0200)%}{% set result = result + 'Bit10, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(11)%}{% set result = result + 'Bit11, '%}
|
||||
{% if val_int | bitwise_and(0x0400)%}{% set result = result + 'Bit11, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(12)%}{% set result = result + 'Bit12, '%}
|
||||
{% if val_int | bitwise_and(0x0800)%}{% set result = result + 'Bit12, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(13)%}{% set result = result + 'Bit13, '%}
|
||||
{% if val_int | bitwise_and(0x1000)%}{% set result = result + 'Bit13, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(14)%}{% set result = result + 'Bit14, '%}
|
||||
{% if val_int | bitwise_and(0x2000)%}{% set result = result + 'Bit14, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(15)%}{% set result = result + 'Bit15, '%}
|
||||
{% if val_int | bitwise_and(0x4000)%}{% set result = result + 'Bit15, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(16)%}{% set result = result + 'Bit16, '%}
|
||||
{% if val_int | bitwise_and(0x8000)%}{% set result = result + 'Bit16, '%}
|
||||
{% endif %}
|
||||
{% endif %}
|
||||
{{ result }}
|
||||
{% else %}
|
||||
{{ this.state }}
|
||||
{% endif %}
|
||||
'''
|
||||
__batt_alarm_val_tpl = '''
|
||||
{% if 'Batterie_Alarm' in value_json and
|
||||
value_json['Batterie_Alarm'] != None %}
|
||||
{% set val_int = value_json['Batterie_Alarm'] | int %}
|
||||
{% if val_int == 0 %}
|
||||
{% set result = 'noAlarm'%}
|
||||
{%else%}
|
||||
{% set result = '' %}
|
||||
{% if val_int | bitwise_and(0x0001)%}
|
||||
{% set result = result + 'PV1-OverVoltage, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0002)%}
|
||||
{% set result = result + 'PV2-OverVoltage, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0004)%}
|
||||
{% set result = result + 'EquipmentOverheating, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0008)%}
|
||||
{% set result = result + 'EquipmentLowTemp, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0010)%}
|
||||
{% set result = result + 'BMS-CommFailed, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0020)%}
|
||||
{% set result = result + 'UnderVoltageProt, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0040)%}
|
||||
{% set result = result + 'ChargingHighTemp, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0080)%}
|
||||
{% set result = result + 'ChargingLowTemp, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0100)%}
|
||||
{% set result = result + 'DischargeHighTemp, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0200)%}
|
||||
{% set result = result + 'DischargeLowTemp, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0400)%}
|
||||
{% set result = result + 'BatterieOverVoltage, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x0800)%}
|
||||
{% set result = result + 'SingleCorePressureDifferenceIsTooLarge, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x1000)%}
|
||||
{% set result = result + 'Bit-12, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x2000)%}
|
||||
{% set result = result + 'Bit-13, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x4000)%}
|
||||
{% set result = result + 'Bit-14, '%}
|
||||
{% endif %}
|
||||
{% if val_int | bitwise_and(0x8000)%}
|
||||
{% set result = result + 'Bit-15, '%}
|
||||
{% endif %}
|
||||
{% endif %}
|
||||
{{ result }}
|
||||
@@ -562,8 +629,8 @@ class Infos:
|
||||
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':FMT_FLOAT,'name': 'Grid Voltage'}}, # noqa: E501
|
||||
|
||||
# events
|
||||
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
|
||||
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
|
||||
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
|
||||
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
|
||||
Register.EVENT_BF1: {'name': ['events', 'Inverter_Bitfield_1'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
||||
Register.EVENT_BF2: {'name': ['events', 'Inverter_bitfield_2'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
||||
# Register.EVENT_409: {'name': ['events', '409_No_Utility'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
@@ -637,10 +704,10 @@ class Infos:
|
||||
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
|
||||
# Batterie DC-1000: Electricity Genration
|
||||
Register.BATT_STATUS_1: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
||||
Register.BATT_PV1_STATUS: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
||||
Register.BATT_PV1_VOLT: {'name': ['batterie', 'pv1', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV1_CUR: {'name': ['batterie', 'pv1', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_STATUS_2: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
||||
Register.BATT_PV2_STATUS: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
||||
Register.BATT_PV2_VOLT: {'name': ['batterie', 'pv2', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV2_CUR: {'name': ['batterie', 'pv2', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV_PWR: {'name': ['batterie', 'PV_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'pv_power_', 'fmt': FMT_INT, 'name': 'PV Power'}}, # noqa: E501
|
||||
@@ -648,6 +715,7 @@ class Infos:
|
||||
Register.BATT_OUT_VOLT: {'name': ['batterie', 'out', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'val_tpl': "{{ (value_json['out']['Voltage'] | float)}}", 'name': 'Output Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_OUT_CUR: {'name': ['batterie', 'out', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'val_tpl': "{{ (value_json['out']['Current'] | float)}}", 'name': 'Output Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_OUT_PWR: {'name': ['batterie', 'out', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'val_tpl': "{{ (value_json['out']['Power'] | int)}}", 'name': 'Supply Power'}}, # noqa: E501
|
||||
Register.BATT_PWR_SUPL_STATE: {'name': ['batterie', 'out', 'Suppl_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_supply_', 'name': 'Supply State', 'val_tpl': __supply_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
||||
|
||||
# Batterie DC-1000: Cell Package
|
||||
Register.BATT_CELL1_VOLT: {'name': ['batterie', 'cell', 'Volt1'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell1_', 'val_tpl': "{{ (value_json['cell']['Volt1'] | float)}}", 'name': 'Cell-01 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
@@ -673,12 +741,13 @@ class Infos:
|
||||
Register.BATT_PWR: {'name': ['batterie', 'batt', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_', 'val_tpl': "{{ (value_json['batt']['Power'] | int)}}", 'name': 'Batterie Power'}}, # noqa: E501
|
||||
Register.BATT_SOC: {'name': ['batterie', 'batt', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'val_tpl': "{{ (value_json['batt']['SOC'] | float)}}", 'name': 'State of Charge (SOC)', 'icon': 'mdi:battery-90'}}, # noqa: E501
|
||||
Register.BATT_TOTAL_CHARG: {'name': ['batterie', 'batt', 'Total_Charging'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'batterie', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_charg_', 'val_tpl': "{{ (value_json['batt']['Total_Charging'] | float)}}", 'name': TOTAL_CHARG, 'icon': 'mdi:battery-charging', 'must_incr': True}}, # noqa: E501
|
||||
Register.BATT_STATUS: {'name': ['batterie', 'batt', 'Batt_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_batt_', 'name': 'Batterie State', 'val_tpl': __batt_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
||||
|
||||
Register.BATT_TEMP_1: {'name': ['batterie', 'cell', 'Temp_1'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_1_', 'val_tpl': "{{ (value_json['cell']['Temp_1'] | int)}}", 'name': 'Cell Temp-1', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_TEMP_2: {'name': ['batterie', 'cell', 'Temp_2'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_2_', 'val_tpl': "{{ (value_json['cell']['Temp_2'] | int)}}", 'name': 'Cell Temp-2', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_TEMP_3: {'name': ['batterie', 'cell', 'Temp_3'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_3_', 'val_tpl': "{{ (value_json['cell']['Temp_3'] | int)}}", 'name': 'Cell Temp-3', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_TEMP_4: {'name': ['batterie', 'Controller_Temp'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_4_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501
|
||||
Register.BATT_74: {'name': ['batterie', 'Reg_74'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_74_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_ALARM: {'name': ['batterie', 'Batterie_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'batt_alarm_', 'name': 'Batterie Alarm', 'val_tpl': __batt_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
|
||||
Register.BATT_HW_VERS: {'name': ['batterie', 'Hardware_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
||||
Register.BATT_SW_VERS: {'name': ['batterie', 'Software_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
||||
|
||||
|
||||
@@ -43,8 +43,8 @@ class Modbus():
|
||||
0x000a: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 voltage
|
||||
0x000b: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 current
|
||||
0x000c: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
|
||||
0x000e: {'reg': Register.BATT_STATUS_1, 'fmt': '!H'}, # noqa: E501
|
||||
0x000f: {'reg': Register.BATT_STATUS_2, 'fmt': '!H'}, # noqa: E501
|
||||
0x000e: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x000f: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x0010: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x0011: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x0012: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
|
||||
@@ -71,7 +71,7 @@ class Modbus():
|
||||
0x0027: {'reg': Register.BATT_OUT_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
|
||||
0x0028: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x0029: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E501
|
||||
0x002a: {'reg': Register.BATT_74, 'fmt': '!h'}, # noqa: E501
|
||||
0x002a: {'reg': Register.BATT_ALARM, 'fmt': '!h'}, # noqa: E501
|
||||
0x002b: {'reg': Register.BATT_HW_VERS, 'fmt': '!h'}, # noqa: E501
|
||||
0x002c: {'reg': Register.BATT_SW_VERS, 'fmt': '!h'}, # noqa: E501
|
||||
|
||||
|
||||
@@ -221,7 +221,7 @@ def inv_data_seq2(): # Data indication from the controller
|
||||
return msg
|
||||
|
||||
@pytest.fixture
|
||||
def inv_data_seq3(): # Inverter indication from MS-2000
|
||||
def inv_data_seq3(): # Inverter indication from MS-3000
|
||||
|
||||
msg = b'\x00\x00\x01\x2c\x00\x00\x00\x64\x53\x00\x00' # | ..^.....,...dS..
|
||||
msg += b'\x00\x00\x00\xc8\x53\x44\x00\x00\x00\x01\x2c\x53\x00\x00\x00\x00' # | ....SD....,S....
|
||||
|
||||
@@ -82,13 +82,25 @@ def batterie_data(): # 0x4210 ftype: 0x01
|
||||
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
|
||||
return msg
|
||||
|
||||
@pytest.fixture
|
||||
def batterie_data1(): # 0x4210 ftype: 0x01
|
||||
msg = b'\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01\x26\x30\xc7\xde'
|
||||
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
|
||||
msg += b'\x34\x31\x30\x31\x32\x34\x30\x37\x30\x31\x34\x39\x30\x33\x31\x34'
|
||||
msg += b'\x0d\x3a\x00\x70\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
|
||||
msg += b'\x01\x00\x00\x00\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
|
||||
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
|
||||
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x0c\x0e\x01\x00'
|
||||
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
|
||||
return msg
|
||||
|
||||
@pytest.fixture
|
||||
def batterie_data2(): # 0x4210 ftype: 0x01
|
||||
msg = b'\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01\x26\x30\xc7\xde'
|
||||
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
|
||||
msg += b'\x34\x31\x30\x31\x32\x34\x30\x37\x30\x31\x34\x39\x30\x33\x31\x34'
|
||||
msg += b'\x0d\x3a\x00\x70\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
|
||||
msg += b'\x14\x0e\xff\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
|
||||
msg += b'\x14\x0e\x02\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
|
||||
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
|
||||
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e'
|
||||
return msg
|
||||
@@ -157,10 +169,29 @@ def test_parse_4210_3026(batterie_data: bytes):
|
||||
"inverter": {"Serial_Number": "4101240701490314"},
|
||||
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
|
||||
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
|
||||
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": -0.02, "SOC": 10.0, "Power": -1.0268000000000002},
|
||||
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": -0.02, "SOC": 10.0, "Power": -1.0268000000000002, 'Batt_State': 0},
|
||||
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
|
||||
"out": {"Voltage": 0.14, "Current": 0.0, "Out_Status": 0, "Power": 0.0},
|
||||
"Controller_Temp": 15, "Reg_74": 0, "Hardware_Version": 517, "Software_Version": 513,
|
||||
"out": {"Voltage": 0.14, "Current": 0.0, "Out_Status": 0, "Power": 0.0, "Suppl_State": 0},
|
||||
"Controller_Temp": 15, "Batterie_Alarm": 0, "Hardware_Version": 517, "Software_Version": 513,
|
||||
"PV_Power": 37.9232},
|
||||
})
|
||||
|
||||
def test_parse_4210_3026_prod(batterie_data1: bytes):
|
||||
i = InfosG3P(client_mode=False)
|
||||
i.db.clear()
|
||||
|
||||
for key, update in i.parse (batterie_data1, 0x42, 1, 0x3026):
|
||||
pass # side effect is calling generator i.parse()
|
||||
|
||||
assert json.dumps(i.db) == json.dumps({
|
||||
"controller": {"Sensor_List": "3026", "Power_On_Time": 4684},
|
||||
"inverter": {"Serial_Number": "4101240701490314"},
|
||||
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
|
||||
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
|
||||
"batt": {"Total_Charging": 20.8, "Voltage": 2.56, "Current": 0.0, "SOC": 10.0, "Power": 0.0, 'Batt_State': 1},
|
||||
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
|
||||
"out": {"Voltage": 30.86, "Current": 2.56, "Out_Status": 0, "Power": 79.0016, "Suppl_State": 1},
|
||||
"Controller_Temp": 15, "Batterie_Alarm": 0, "Hardware_Version": 517, "Software_Version": 513,
|
||||
"PV_Power": 37.9232},
|
||||
})
|
||||
|
||||
@@ -176,10 +207,10 @@ def test_parse_4210_3026_incomplete(batterie_data2: bytes):
|
||||
"inverter": {"Serial_Number": "4101240701490314"},
|
||||
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
|
||||
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
|
||||
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": -0.02, "SOC": 10.0, "Power": -1.0268000000000002},
|
||||
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": 7.66, "SOC": 10.0, "Power": 393.2644, 'Batt_State': 2},
|
||||
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
|
||||
"out": {"Voltage": 0.14, "Current": None, "Out_Status": None, "Power": None},
|
||||
"Controller_Temp": None, "Reg_74": None, "Hardware_Version": None, "Software_Version": None,
|
||||
"out": {"Voltage": 0.14, "Current": None, "Out_Status": None, "Power": None, "Suppl_State": None},
|
||||
"Controller_Temp": None, "Batterie_Alarm": None, "Hardware_Version": None, "Software_Version": None,
|
||||
"PV_Power": 37.9232},
|
||||
})
|
||||
|
||||
|
||||
@@ -47,7 +47,16 @@ dev debug: local_add_on
|
||||
export IMAGE=$(PRIVAT_CONTAINER_REGISTRY)$(IMAGE) && \
|
||||
docker buildx bake -f docker-bake.hcl $@
|
||||
|
||||
rc rel: local_add_on
|
||||
rc: local_add_on
|
||||
@[ "${RC}" ] || ( echo ">> RC is not set"; exit 1 )
|
||||
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
|
||||
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
|
||||
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
|
||||
export VERSION=$(VERSION)-$@$(RC) && \
|
||||
export IMAGE=$(PUBLIC_CONTAINER_REGISTRY)$(IMAGE) && \
|
||||
docker buildx bake -f docker-bake.hcl $@
|
||||
|
||||
rel: local_add_on
|
||||
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
|
||||
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
|
||||
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
|
||||
|
||||
@@ -153,9 +153,9 @@ def dcu_data_ind_msg(): # 0x4210
|
||||
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
|
||||
msg += get_dcu_no()
|
||||
msg += b'\x0d\x3a\x00\x0a\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
|
||||
msg += b'\x14\x0e\xff\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
|
||||
msg += b'\x14\x0e\x05\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
|
||||
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
|
||||
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e\x00\x00'
|
||||
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e\x02\x00'
|
||||
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
|
||||
msg += correct_checksum(msg)
|
||||
msg += b'\x15'
|
||||
|
||||
Reference in New Issue