Compare commits

..

23 Commits

Author SHA1 Message Date
Stefan Allius
f8ac43f183 set BUILD_ID only for dev and debug versions 2025-04-13 23:44:59 +02:00
Stefan Allius
279a6c030c bump version to 0.14.0 2025-04-13 23:44:25 +02:00
Stefan Allius
586a5d5c3d Merge branch 'main' of https://github.com/s-allius/tsun-gen3-proxy into start-version-0.14 2025-04-13 23:42:57 +02:00
renovate[bot]
5568a017ec Update python Docker tag to v3.13.3 (#359)
Co-authored-by: renovate[bot] <29139614+renovate[bot]@users.noreply.github.com>
2025-04-13 23:39:44 +02:00
renovate[bot]
4a70f366f1 Update dependency aiomqtt to v2.3.2 (#358)
* Update dependency aiomqtt to v2.3.2

---------

Co-authored-by: renovate[bot] <29139614+renovate[bot]@users.noreply.github.com>
Co-authored-by: Stefan Allius <stefan.allius@t-online.de>
2025-04-13 23:38:38 +02:00
Stefan Allius
00657c31f3 Fix rel build (#372)
* build rel without BUILD_ID

* update changelog
2025-04-13 21:22:45 +02:00
Stefan Allius
22ebad2edb Update rel 0.13.0 (#371)
* update compose help link

(cherry picked from commit 6d4ff0d508)

* fix link

(cherry picked from commit 3d422f9249)

* retrigger sonar qube test run

* fix rel build run

* bump version
2025-04-13 20:57:31 +02:00
Stefan Allius
aac89065fd Update rel 0.13.0 (#370)
* bump version
2025-04-13 20:56:10 +02:00
Stefan Allius
e3c2672ea9 Fix rel build (#369)
* disable cache for rc build

* bump python version to 3.12.10-r0
2025-04-13 20:37:34 +02:00
Stefan Allius
fe250d478a Fix rel build (#368)
* fix rel build run

* disable cache for rc build

* bump python version to 3.12.10-r0
2025-04-13 20:35:21 +02:00
Stefan Allius
86d9fc8c8f Update rel 0.13.0 (#366)
* update compose help link

(cherry picked from commit 6d4ff0d508)

* fix link

(cherry picked from commit 3d422f9249)

* fix rel build run
2025-04-13 20:02:10 +02:00
Stefan Allius
83a723c959 Update rel 0.13.0 (#367)
* fix link

(cherry picked from commit 3d422f9249)

* update compose help link

(cherry picked from commit 6d4ff0d508)

* fix link

(cherry picked from commit 3d422f9249)

* fix rel build run
2025-04-13 19:59:05 +02:00
Stefan Allius
9031b5c793 Update rel 0.13.0 (#365)
* update compose help link

(cherry picked from commit 6d4ff0d508)

* fix link

(cherry picked from commit 3d422f9249)
2025-04-13 19:20:08 +02:00
Stefan Allius
9f27c5a582 fix link
(cherry picked from commit 3d422f9249)
2025-04-13 18:55:16 +02:00
Stefan Allius
abe6bfb013 update compose help link (#361) 2025-04-10 23:58:59 +02:00
renovate[bot]
31f4f05bed Update ghcr.io/hassio-addons/base Docker tag to v17.2.4 (#355)
* Update ghcr.io/hassio-addons/base Docker tag to v17.2.3

* Update ghcr.io/hassio-addons/base Docker tag to v17.2.4

---------

Co-authored-by: renovate[bot] <29139614+renovate[bot]@users.noreply.github.com>
Co-authored-by: Stefan Allius <stefan.allius@t-online.de>
2025-04-08 20:47:11 +02:00
Stefan Allius
1445268b70 Merge pull request #357 from s-allius/main
define the value 2 for the out status (#356)
2025-04-08 00:11:18 +02:00
Stefan Allius
8ca91c2fdd define the value 2 for the out status (#356) 2025-04-07 23:47:29 +02:00
Stefan Allius
ea749dcce6 enforce numbered release candidates (#353) 2025-04-06 22:28:32 +02:00
Stefan Allius
af5604d029 add alarm bitfields (#352)
- fix bitfield of the inverter alarms
- add batterie alarms
2025-04-06 20:07:17 +02:00
renovate[bot]
015b6b8db0 Update dependency pytest-cov to v6.1.1 (#346)
Co-authored-by: renovate[bot] <29139614+renovate[bot]@users.noreply.github.com>
2025-04-06 01:28:27 +02:00
Stefan Allius
7782a3cb57 Add two states build from the measurements (#351)
* Add two states build from the measurements
- Batterie Status calculated from the batt current
- Power Supply State calc from the out Power

* improve test coverage
2025-04-06 01:21:41 +02:00
Stefan Allius
3d073acc58 Cleanup MQTT json format for DCU batterie (#349)
* Cleanup MQTT json format for DCU batterie
- add hw and sw version
- rename total generation into total charging energy
- rename cell temperature sensors
- restructure json format
- adapt unit tests

* revert changed test packages
2025-04-05 22:30:57 +02:00
18 changed files with 210 additions and 72 deletions

View File

@@ -1 +1 @@
3.13.2
3.13.3

View File

@@ -7,6 +7,8 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
## [unreleased]
## [0.13.0] - 2025-04-13
- update dependency python to 3.13
- add initial support for TSUN MS-3000
- add initial apparmor support [#293](https://github.com/s-allius/tsun-gen3-proxy/issues/293)

View File

@@ -141,7 +141,7 @@ No special configuration is required for the Docker container if it is built and
On the host, two directories (for log files and for config files) must be mapped. If necessary, the UID of the proxy process can be adjusted, which is also the owner of the log and configuration files.
A description of the configuration parameters can be found [here](https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#docker-compose-environment-variables).
A description of the configuration parameters can be found [here](https://github.com/s-allius/tsun-gen3-proxy/wiki/configuration-env#docker-compose-environment-variables)
## Proxy Configuration

View File

@@ -1 +1 @@
0.13.0
0.14.0

View File

@@ -22,7 +22,16 @@ dev debug:
export IMAGE=$(PRIVAT_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
preview rc rel:
rc:
@[ "${RC}" ] || ( echo ">> RC is not set"; exit 1 )
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
export VERSION=$(VERSION)-$@$(RC) && \
export IMAGE=$(PUBLIC_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
preview rel:
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"

View File

@@ -1,7 +1,7 @@
flake8==7.2.0
pytest==8.3.5
pytest-asyncio==0.26.0
pytest-cov==6.1.0
pytest-cov==6.1.1
python-dotenv==1.1.0
mock==5.2.0
coverage==7.8.0

View File

@@ -1,4 +1,4 @@
aiomqtt==2.3.1
aiomqtt==2.3.2
schema==0.7.7
aiocron==2.1
aiohttp==3.11.16

View File

@@ -19,6 +19,19 @@ class RegisterFunc:
result += prod
return result
@staticmethod
def cmp_values(info: Infos, params: map) -> None | int:
try:
val = info.get_db_value(params['reg'])
if val < params['cmp_val']:
return params['res'][0]
if val == params['cmp_val']:
return params['res'][1]
return params['res'][2]
except Exception:
pass
return None
class RegisterMap:
# make the class read/only by using __slots__
@@ -136,8 +149,8 @@ class RegisterMap:
0x42010034: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Voltage PV2
0x42010036: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Current PV2
0x42010038: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
0x4201003c: {'reg': Register.BATT_STATUS_1, 'fmt': '!H'}, # noqa: E501 MPTT-1 Operating Status: 0(Standby), 1(Work)
0x4201003e: {'reg': Register.BATT_STATUS_2, 'fmt': '!H'}, # noqa: E501 MPTT-2 Operating Status: 0(Standby), 1(Work)
0x4201003c: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-1 Operating Status: 0(Standby), 1(Work)
0x4201003e: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-2 Operating Status: 0(Standby), 1(Work)
0x42010040: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x42010042: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501 => Batterie Status: <0(Discharging), 0(Static), 0>(Loading)
0x42010044: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
@@ -164,7 +177,7 @@ class RegisterMap:
0x4201006e: {'reg': Register.BATT_OUT_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 Output Current
0x42010070: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!H'}, # noqa: E501 Output Working Status: 0(Standby), 1(Work)
0x42010072: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E50, Environment temp
0x42010074: {'reg': Register.BATT_74, 'fmt': '!H'}, # noqa: E501 Warning Alarmcode 1, Bit 0..15
0x42010074: {'reg': Register.BATT_ALARM, 'fmt': '!H'}, # noqa: E501 Warning Alarmcode 1, Bit 0..15
0x42010076: {'reg': Register.BATT_HW_VERS, 'fmt': '!h'}, # noqa: E501 hardware version
0x42010078: {'reg': Register.BATT_SW_VERS, 'fmt': '!h'}, # noqa: E501 software main version
'calc': {
@@ -173,8 +186,12 @@ class RegisterMap:
[Register.BATT_PV2_VOLT, Register.BATT_PV2_CUR]]},
2: {'reg': Register.BATT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
'params': [[Register.BATT_VOLT, Register.BATT_CUR]]},
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Supply Power => Power Supply State: 0(Idle), 0>(Power Supply)
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Supply Power => Power Supply State: 0(Idle), 0>(Power Supply)
'params': [[Register.BATT_OUT_VOLT, Register.BATT_OUT_CUR]]},
4: {'reg': Register.BATT_PWR_SUPL_STATE, 'func': RegisterFunc.cmp_values, # noqa: E501
'params': {'reg': Register.BATT_OUT_PWR, 'cmp_val': 0, 'res': [0, 0, 1]}}, # noqa: E501
5: {'reg': Register.BATT_STATUS, 'func': RegisterFunc.cmp_values, # noqa: E501
'params': {'reg': Register.BATT_CUR, 'cmp_val': 0.0, 'res': [0, 1, 2]}} # noqa: E501
}
}

View File

@@ -126,8 +126,8 @@ class Register(Enum):
BATT_PV2_VOLT = 1002
BATT_PV2_CUR = 1003
BATT_TOTAL_CHARG = 1005
BATT_STATUS_1 = 1006
BATT_STATUS_2 = 1007
BATT_PV1_STATUS = 1006
BATT_PV2_STATUS = 1007
BATT_VOLT = 1010
BATT_CUR = 1011
BATT_SOC = 1012
@@ -154,12 +154,14 @@ class Register(Enum):
BATT_OUT_CUR = 1033
BATT_OUT_STATUS = 1034
BATT_TEMP_4 = 1035
BATT_74 = 1036
BATT_ALARM = 1036
BATT_HW_VERS = 1037
BATT_SW_VERS = 1038
BATT_PV_PWR = 1040
BATT_PWR = 1041
BATT_OUT_PWR = 1042
BATT_PWR_SUPL_STATE = 1043
BATT_STATUS = 1044
TEST_VAL_0 = 2000
TEST_VAL_1 = 2001
@@ -324,6 +326,7 @@ class Infos:
SOLAR_POWER_VAR = 'mdi:solar-power-variant'
SOLAR_POWER = 'mdi:solar-power'
WIFI = 'mdi:wifi'
ALARM_LIGHT = 'mdi:alarm-light'
UPDATE = 'mdi:update'
DAILY_GEN = 'Daily Generation'
TOTAL_GEN = 'Total Generation'
@@ -377,7 +380,9 @@ class Infos:
__status_type_val_tpl = "{%set inv_status = ['Off-line', 'On-grid', 'Off-grid'] %}{{inv_status[value_json['Inverter_Status']|int(0)]|default(value_json['Inverter_Status'])}}" # noqa: E501
__mppt1_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv1']['MPPT-Status']|int(0)]|default(value_json['pv1']['MPPT-Status'])}}" # noqa: E501
__mppt2_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv2']['MPPT-Status']|int(0)]|default(value_json['pv2']['MPPT-Status'])}}" # noqa: E501
__out_status_type_val_tpl = "{%set out_status = ['Standby', 'On'] %}{{out_status[value_json['out']['Out_Status']|int(0)]|default(value_json['out']['Out_Status'])}}" # noqa: E501
__supply_status_type_val_tpl = "{%set supply_status = ['Idle', 'Power-Supply'] %}{{supply_status[value_json['out']['Suppl_State']|int(0)]|default(value_json['out']['Suppl_State'])}}" # noqa: E501
__batt_status_type_val_tpl = "{%set batt_status = ['Discharging', 'Static', 'Loading'] %}{{batt_status[value_json['batt']['Batt_State']|int(0)]|default(value_json['batt']['Batt_State'])}}" # noqa: E501
__out_status_type_val_tpl = "{%set out_status = ['Standby', 'On', 'Off'] %}{{out_status[value_json['out']['Out_Status']|int(0)]|default(value_json['out']['Out_Status'])}}" # noqa: E501
__rated_power_val_tpl = "{% if 'Rated_Power' in value_json and value_json['Rated_Power'] != None %}{{value_json['Rated_Power']|string() +' W'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
__designed_power_val_tpl = '''
{% if 'Max_Designed_Power' in value_json and
@@ -399,52 +404,52 @@ class Infos:
{% set result = 'noAlarm'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(1)%}
{% if val_int | bitwise_and(0x0001)%}
{% set result = result + 'HBridgeFault, '%}
{% endif %}
{% if val_int | bitwise_and(2)%}
{% if val_int | bitwise_and(0x0002)%}
{% set result = result + 'DriVoltageFault, '%}
{% endif %}
{% if val_int | bitwise_and(3)%}
{% if val_int | bitwise_and(0x0004)%}
{% set result = result + 'GFDI-Fault, '%}
{% endif %}
{% if val_int | bitwise_and(4)%}
{% if val_int | bitwise_and(0x0008)%}
{% set result = result + 'OverTemp, '%}
{% endif %}
{% if val_int | bitwise_and(5)%}
{% if val_int | bitwise_and(0x0010)%}
{% set result = result + 'CommLose, '%}
{% endif %}
{% if val_int | bitwise_and(6)%}
{% if val_int | bitwise_and(0x0020)%}
{% set result = result + 'Bit6, '%}
{% endif %}
{% if val_int | bitwise_and(7)%}
{% if val_int | bitwise_and(0x0040)%}
{% set result = result + 'Bit7, '%}
{% endif %}
{% if val_int | bitwise_and(8)%}
{% if val_int | bitwise_and(0x0080)%}
{% set result = result + 'EEPROM-Fault, '%}
{% endif %}
{% if val_int | bitwise_and(9)%}
{% if val_int | bitwise_and(0x0100)%}
{% set result = result + 'NoUtility, '%}
{% endif %}
{% if val_int | bitwise_and(10)%}
{% if val_int | bitwise_and(0x0200)%}
{% set result = result + 'VG_Offset, '%}
{% endif %}
{% if val_int | bitwise_and(11)%}
{% if val_int | bitwise_and(0x0400)%}
{% set result = result + 'Relais_Open, '%}
{% endif %}
{% if val_int | bitwise_and(12)%}
{% if val_int | bitwise_and(0x0800)%}
{% set result = result + 'Relais_Short, '%}
{% endif %}
{% if val_int | bitwise_and(13)%}
{% if val_int | bitwise_and(0x1000)%}
{% set result = result + 'GridVoltOverRating, '%}
{% endif %}
{% if val_int | bitwise_and(14)%}
{% if val_int | bitwise_and(0x2000)%}
{% set result = result + 'GridVoltUnderRating, '%}
{% endif %}
{% if val_int | bitwise_and(15)%}
{% if val_int | bitwise_and(0x4000)%}
{% set result = result + 'GridFreqOverRating, '%}
{% endif %}
{% if val_int | bitwise_and(16)%}
{% if val_int | bitwise_and(0x8000)%}
{% set result = result + 'GridFreqUnderRating, '%}
{% endif %}
{% endif %}
@@ -461,42 +466,104 @@ class Infos:
{% set result = 'noFault'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(1)%}
{% if val_int | bitwise_and(0x0001)%}
{% set result = result + 'PVOV-Fault (PV OverVolt), '%}
{% endif %}
{% if val_int | bitwise_and(2)%}
{% if val_int | bitwise_and(0x0002)%}
{% set result = result + 'PVLV-Fault (PV LowVolt), '%}
{% endif %}
{% if val_int | bitwise_and(3)%}
{% if val_int | bitwise_and(0x0004)%}
{% set result = result + 'PV OI-Fault (PV OverCurrent), '%}
{% endif %}
{% if val_int | bitwise_and(4)%}
{% if val_int | bitwise_and(0x0008)%}
{% set result = result + 'PV OFV-Fault, '%}
{% endif %}
{% if val_int | bitwise_and(5)%}
{% if val_int | bitwise_and(0x0010)%}
{% set result = result + 'DC ShortCircuitFault, '%}
{% endif %}
{% if val_int | bitwise_and(6)%}{% set result = result + 'Bit6, '%}
{% if val_int | bitwise_and(0x0020)%}{% set result = result + 'Bit6, '%}
{% endif %}
{% if val_int | bitwise_and(7)%}{% set result = result + 'Bit7, '%}
{% if val_int | bitwise_and(0x0040)%}{% set result = result + 'Bit7, '%}
{% endif %}
{% if val_int | bitwise_and(8)%}{% set result = result + 'Bit8, '%}
{% if val_int | bitwise_and(0x0080)%}{% set result = result + 'Bit8, '%}
{% endif %}
{% if val_int | bitwise_and(9)%}{% set result = result + 'Bit9, '%}
{% if val_int | bitwise_and(0x0100)%}{% set result = result + 'Bit9, '%}
{% endif %}
{% if val_int | bitwise_and(10)%}{% set result = result + 'Bit10, '%}
{% if val_int | bitwise_and(0x0200)%}{% set result = result + 'Bit10, '%}
{% endif %}
{% if val_int | bitwise_and(11)%}{% set result = result + 'Bit11, '%}
{% if val_int | bitwise_and(0x0400)%}{% set result = result + 'Bit11, '%}
{% endif %}
{% if val_int | bitwise_and(12)%}{% set result = result + 'Bit12, '%}
{% if val_int | bitwise_and(0x0800)%}{% set result = result + 'Bit12, '%}
{% endif %}
{% if val_int | bitwise_and(13)%}{% set result = result + 'Bit13, '%}
{% if val_int | bitwise_and(0x1000)%}{% set result = result + 'Bit13, '%}
{% endif %}
{% if val_int | bitwise_and(14)%}{% set result = result + 'Bit14, '%}
{% if val_int | bitwise_and(0x2000)%}{% set result = result + 'Bit14, '%}
{% endif %}
{% if val_int | bitwise_and(15)%}{% set result = result + 'Bit15, '%}
{% if val_int | bitwise_and(0x4000)%}{% set result = result + 'Bit15, '%}
{% endif %}
{% if val_int | bitwise_and(16)%}{% set result = result + 'Bit16, '%}
{% if val_int | bitwise_and(0x8000)%}{% set result = result + 'Bit16, '%}
{% endif %}
{% endif %}
{{ result }}
{% else %}
{{ this.state }}
{% endif %}
'''
__batt_alarm_val_tpl = '''
{% if 'Batterie_Alarm' in value_json and
value_json['Batterie_Alarm'] != None %}
{% set val_int = value_json['Batterie_Alarm'] | int %}
{% if val_int == 0 %}
{% set result = 'noAlarm'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(0x0001)%}
{% set result = result + 'PV1-OverVoltage, '%}
{% endif %}
{% if val_int | bitwise_and(0x0002)%}
{% set result = result + 'PV2-OverVoltage, '%}
{% endif %}
{% if val_int | bitwise_and(0x0004)%}
{% set result = result + 'EquipmentOverheating, '%}
{% endif %}
{% if val_int | bitwise_and(0x0008)%}
{% set result = result + 'EquipmentLowTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0010)%}
{% set result = result + 'BMS-CommFailed, '%}
{% endif %}
{% if val_int | bitwise_and(0x0020)%}
{% set result = result + 'UnderVoltageProt, '%}
{% endif %}
{% if val_int | bitwise_and(0x0040)%}
{% set result = result + 'ChargingHighTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0080)%}
{% set result = result + 'ChargingLowTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0100)%}
{% set result = result + 'DischargeHighTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0200)%}
{% set result = result + 'DischargeLowTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0400)%}
{% set result = result + 'BatterieOverVoltage, '%}
{% endif %}
{% if val_int | bitwise_and(0x0800)%}
{% set result = result + 'SingleCorePressureDifferenceIsTooLarge, '%}
{% endif %}
{% if val_int | bitwise_and(0x1000)%}
{% set result = result + 'Bit-12, '%}
{% endif %}
{% if val_int | bitwise_and(0x2000)%}
{% set result = result + 'Bit-13, '%}
{% endif %}
{% if val_int | bitwise_and(0x4000)%}
{% set result = result + 'Bit-14, '%}
{% endif %}
{% if val_int | bitwise_and(0x8000)%}
{% set result = result + 'Bit-15, '%}
{% endif %}
{% endif %}
{{ result }}
@@ -562,8 +629,8 @@ class Infos:
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':FMT_FLOAT,'name': 'Grid Voltage'}}, # noqa: E501
# events
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
Register.EVENT_BF1: {'name': ['events', 'Inverter_Bitfield_1'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.EVENT_BF2: {'name': ['events', 'Inverter_bitfield_2'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
# Register.EVENT_409: {'name': ['events', '409_No_Utility'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
@@ -637,10 +704,10 @@ class Infos:
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
# Batterie DC-1000: Electricity Genration
Register.BATT_STATUS_1: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV1_STATUS: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV1_VOLT: {'name': ['batterie', 'pv1', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV1_CUR: {'name': ['batterie', 'pv1', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_STATUS_2: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV2_STATUS: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV2_VOLT: {'name': ['batterie', 'pv2', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV2_CUR: {'name': ['batterie', 'pv2', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV_PWR: {'name': ['batterie', 'PV_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'pv_power_', 'fmt': FMT_INT, 'name': 'PV Power'}}, # noqa: E501
@@ -648,6 +715,7 @@ class Infos:
Register.BATT_OUT_VOLT: {'name': ['batterie', 'out', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'val_tpl': "{{ (value_json['out']['Voltage'] | float)}}", 'name': 'Output Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_OUT_CUR: {'name': ['batterie', 'out', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'val_tpl': "{{ (value_json['out']['Current'] | float)}}", 'name': 'Output Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_OUT_PWR: {'name': ['batterie', 'out', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'val_tpl': "{{ (value_json['out']['Power'] | int)}}", 'name': 'Supply Power'}}, # noqa: E501
Register.BATT_PWR_SUPL_STATE: {'name': ['batterie', 'out', 'Suppl_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_supply_', 'name': 'Supply State', 'val_tpl': __supply_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
# Batterie DC-1000: Cell Package
Register.BATT_CELL1_VOLT: {'name': ['batterie', 'cell', 'Volt1'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell1_', 'val_tpl': "{{ (value_json['cell']['Volt1'] | float)}}", 'name': 'Cell-01 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
@@ -673,12 +741,13 @@ class Infos:
Register.BATT_PWR: {'name': ['batterie', 'batt', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_', 'val_tpl': "{{ (value_json['batt']['Power'] | int)}}", 'name': 'Batterie Power'}}, # noqa: E501
Register.BATT_SOC: {'name': ['batterie', 'batt', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'val_tpl': "{{ (value_json['batt']['SOC'] | float)}}", 'name': 'State of Charge (SOC)', 'icon': 'mdi:battery-90'}}, # noqa: E501
Register.BATT_TOTAL_CHARG: {'name': ['batterie', 'batt', 'Total_Charging'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'batterie', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_charg_', 'val_tpl': "{{ (value_json['batt']['Total_Charging'] | float)}}", 'name': TOTAL_CHARG, 'icon': 'mdi:battery-charging', 'must_incr': True}}, # noqa: E501
Register.BATT_STATUS: {'name': ['batterie', 'batt', 'Batt_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_batt_', 'name': 'Batterie State', 'val_tpl': __batt_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_TEMP_1: {'name': ['batterie', 'cell', 'Temp_1'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_1_', 'val_tpl': "{{ (value_json['cell']['Temp_1'] | int)}}", 'name': 'Cell Temp-1', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_2: {'name': ['batterie', 'cell', 'Temp_2'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_2_', 'val_tpl': "{{ (value_json['cell']['Temp_2'] | int)}}", 'name': 'Cell Temp-2', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_3: {'name': ['batterie', 'cell', 'Temp_3'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_3_', 'val_tpl': "{{ (value_json['cell']['Temp_3'] | int)}}", 'name': 'Cell Temp-3', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_4: {'name': ['batterie', 'Controller_Temp'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_4_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501
Register.BATT_74: {'name': ['batterie', 'Reg_74'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_74_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_ALARM: {'name': ['batterie', 'Batterie_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'batt_alarm_', 'name': 'Batterie Alarm', 'val_tpl': __batt_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
Register.BATT_HW_VERS: {'name': ['batterie', 'Hardware_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.BATT_SW_VERS: {'name': ['batterie', 'Software_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501

View File

@@ -43,8 +43,8 @@ class Modbus():
0x000a: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 voltage
0x000b: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 current
0x000c: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
0x000e: {'reg': Register.BATT_STATUS_1, 'fmt': '!H'}, # noqa: E501
0x000f: {'reg': Register.BATT_STATUS_2, 'fmt': '!H'}, # noqa: E501
0x000e: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501
0x000f: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501
0x0010: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x0011: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x0012: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
@@ -71,7 +71,7 @@ class Modbus():
0x0027: {'reg': Register.BATT_OUT_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
0x0028: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!H'}, # noqa: E501
0x0029: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E501
0x002a: {'reg': Register.BATT_74, 'fmt': '!h'}, # noqa: E501
0x002a: {'reg': Register.BATT_ALARM, 'fmt': '!h'}, # noqa: E501
0x002b: {'reg': Register.BATT_HW_VERS, 'fmt': '!h'}, # noqa: E501
0x002c: {'reg': Register.BATT_SW_VERS, 'fmt': '!h'}, # noqa: E501

View File

@@ -221,7 +221,7 @@ def inv_data_seq2(): # Data indication from the controller
return msg
@pytest.fixture
def inv_data_seq3(): # Inverter indication from MS-2000
def inv_data_seq3(): # Inverter indication from MS-3000
msg = b'\x00\x00\x01\x2c\x00\x00\x00\x64\x53\x00\x00' # | ..^.....,...dS..
msg += b'\x00\x00\x00\xc8\x53\x44\x00\x00\x00\x01\x2c\x53\x00\x00\x00\x00' # | ....SD....,S....

View File

@@ -82,13 +82,25 @@ def batterie_data(): # 0x4210 ftype: 0x01
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
return msg
@pytest.fixture
def batterie_data1(): # 0x4210 ftype: 0x01
msg = b'\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01\x26\x30\xc7\xde'
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
msg += b'\x34\x31\x30\x31\x32\x34\x30\x37\x30\x31\x34\x39\x30\x33\x31\x34'
msg += b'\x0d\x3a\x00\x70\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
msg += b'\x01\x00\x00\x00\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x0c\x0e\x01\x00'
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
return msg
@pytest.fixture
def batterie_data2(): # 0x4210 ftype: 0x01
msg = b'\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01\x26\x30\xc7\xde'
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
msg += b'\x34\x31\x30\x31\x32\x34\x30\x37\x30\x31\x34\x39\x30\x33\x31\x34'
msg += b'\x0d\x3a\x00\x70\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
msg += b'\x14\x0e\xff\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x14\x0e\x02\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e'
return msg
@@ -157,10 +169,29 @@ def test_parse_4210_3026(batterie_data: bytes):
"inverter": {"Serial_Number": "4101240701490314"},
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": -0.02, "SOC": 10.0, "Power": -1.0268000000000002},
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": -0.02, "SOC": 10.0, "Power": -1.0268000000000002, 'Batt_State': 0},
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
"out": {"Voltage": 0.14, "Current": 0.0, "Out_Status": 0, "Power": 0.0},
"Controller_Temp": 15, "Reg_74": 0, "Hardware_Version": 517, "Software_Version": 513,
"out": {"Voltage": 0.14, "Current": 0.0, "Out_Status": 0, "Power": 0.0, "Suppl_State": 0},
"Controller_Temp": 15, "Batterie_Alarm": 0, "Hardware_Version": 517, "Software_Version": 513,
"PV_Power": 37.9232},
})
def test_parse_4210_3026_prod(batterie_data1: bytes):
i = InfosG3P(client_mode=False)
i.db.clear()
for key, update in i.parse (batterie_data1, 0x42, 1, 0x3026):
pass # side effect is calling generator i.parse()
assert json.dumps(i.db) == json.dumps({
"controller": {"Sensor_List": "3026", "Power_On_Time": 4684},
"inverter": {"Serial_Number": "4101240701490314"},
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
"batt": {"Total_Charging": 20.8, "Voltage": 2.56, "Current": 0.0, "SOC": 10.0, "Power": 0.0, 'Batt_State': 1},
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
"out": {"Voltage": 30.86, "Current": 2.56, "Out_Status": 0, "Power": 79.0016, "Suppl_State": 1},
"Controller_Temp": 15, "Batterie_Alarm": 0, "Hardware_Version": 517, "Software_Version": 513,
"PV_Power": 37.9232},
})
@@ -176,10 +207,10 @@ def test_parse_4210_3026_incomplete(batterie_data2: bytes):
"inverter": {"Serial_Number": "4101240701490314"},
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": -0.02, "SOC": 10.0, "Power": -1.0268000000000002},
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": 7.66, "SOC": 10.0, "Power": 393.2644, 'Batt_State': 2},
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
"out": {"Voltage": 0.14, "Current": None, "Out_Status": None, "Power": None},
"Controller_Temp": None, "Reg_74": None, "Hardware_Version": None, "Software_Version": None,
"out": {"Voltage": 0.14, "Current": None, "Out_Status": None, "Power": None, "Suppl_State": None},
"Controller_Temp": None, "Batterie_Alarm": None, "Hardware_Version": None, "Software_Version": None,
"PV_Power": 37.9232},
})

View File

@@ -32,7 +32,7 @@ rel : STAGE=rel
export BUILD_DATE := ${shell date -Iminutes}
BUILD_ID := ${shell date +'%y%m%d%H%M'}
debug dev : BUILD_ID := ${shell date +'%y%m%d%H%M'}
VERSION := $(shell cat $(SRC)/.version)
export MAJOR := $(shell echo $(VERSION) | cut -f1 -d.)
@@ -47,7 +47,16 @@ dev debug: local_add_on
export IMAGE=$(PRIVAT_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
rc rel: local_add_on
rc: local_add_on
@[ "${RC}" ] || ( echo ">> RC is not set"; exit 1 )
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
export VERSION=$(VERSION)-$@$(RC) && \
export IMAGE=$(PUBLIC_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
rel: local_add_on
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"

View File

@@ -90,6 +90,7 @@ target "preview" {
target "rc" {
inherits = ["_common", "_prod"]
tags = ["${IMAGE}:rc", "${IMAGE}:${VERSION}"]
no-cache = true
}
target "rel" {

View File

@@ -50,7 +50,7 @@ Example add-on configuration after installation:
```yaml
inverters:
- serial: R17E760702080400
- serial: R17E000000000000
node_id: PV-Garage
suggested_area: Garage
modbus_polling: false
@@ -89,7 +89,7 @@ Example add-on configuration for GEN3PLUS energie storages:
```yaml
batteries:
- serial: 4100000000000000
monitor_sn: 2300000000
monitor_sn: 3000000000
node_id: bat_1
suggested_area: Garage
modbus_polling: false
@@ -174,4 +174,4 @@ SOFTWARE.
[AdGuard]: https://github.com/hassio-addons/addon-adguard-home
[repository-badge]: https://img.shields.io/badge/Add%20repository%20to%20my-Home%20Assistant-41BDF5?logo=home-assistant&style=for-the-badge
[repository-url]: https://my.home-assistant.io/redirect/supervisor_add_addon_repository/?repository_url=https%3A%2F%2Fgithub.com%2Fs-allius%2Fha-addons
[configdetails]: https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml
[configdetails]: https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-addon

View File

@@ -13,12 +13,12 @@
# 1 Build Base Image #
######################
ARG BUILD_FROM="ghcr.io/hassio-addons/base:17.2.3"
ARG BUILD_FROM="ghcr.io/hassio-addons/base:17.2.4"
# hadolint ignore=DL3006
FROM $BUILD_FROM AS base
# Installiere Python, pip und virtuelle Umgebungstools
RUN apk add --no-cache python3=3.12.9-r0 py3-pip=24.3.1-r0 && \
RUN apk add --no-cache python3=3.12.10-r0 py3-pip=24.3.1-r0 && \
python -m venv /opt/venv && \
. /opt/venv/bin/activate

View File

@@ -6,6 +6,6 @@
"slug": "tsun-proxy",
"advanced": false,
"stage": "stable",
"readme_dsecr": "Integrates TSUN inverters (e.g. TSOL MS800, MS2000, MS3000) and batteries (TSOL DC1000) into Home Assistant.\n\nIt is based on the [TSUN Proxy][tsunproxy] and enables a reliable connection between TSUN devices and an MQTT broker.\n\nWith the Add-on, you can easily retrieve real-time values such as power, current and daily energy and integrate the inverter into Home Assistant.\nThis works even without an internet connection.\n\nThe optional connection to the TSUN Cloud can be disabled!",
"readme_descr": "Integrates TSUN inverters (e.g. TSOL MS800, MS2000, MS3000) and batteries (TSOL DC1000) into Home Assistant.\n\nIt is based on the [TSUN Proxy][tsunproxy] and enables a reliable connection between TSUN devices and an MQTT broker.\n\nWith the Add-on, you can easily retrieve real-time values such as power, current and daily energy and integrate the inverter into Home Assistant.\nThis works even without an internet connection.\n\nThe optional connection to the TSUN Cloud can be disabled!",
"readme_links": "\n[tsunproxy]: https://github.com/s-allius/tsun-gen3-proxy\n"
}

View File

@@ -153,9 +153,9 @@ def dcu_data_ind_msg(): # 0x4210
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
msg += get_dcu_no()
msg += b'\x0d\x3a\x00\x0a\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
msg += b'\x14\x0e\xff\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x14\x0e\x05\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e\x00\x00'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e\x02\x00'
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
msg += correct_checksum(msg)
msg += b'\x15'