b16a4ad549 enforce numbered release candidates 2025-04-06 22:23:56 +02:00
Stefan Allius
af5604d029 add alarm bitfields (#352)
- fix bitfield of the inverter alarms
- add batterie alarms
2025-04-06 20:07:17 +02:00
renovate[bot]
015b6b8db0 Update dependency pytest-cov to v6.1.1 (#346)
Co-authored-by: renovate[bot] <29139614+renovate[bot]@users.noreply.github.com>
2025-04-06 01:28:27 +02:00
Stefan Allius
7782a3cb57 Add two states build from the measurements (#351)
* Add two states build from the measurements
- Batterie Status calculated from the batt current
- Power Supply State calc from the out Power

* improve test coverage
2025-04-06 01:21:41 +02:00
Stefan Allius
3d073acc58 Cleanup MQTT json format for DCU batterie (#349)
* Cleanup MQTT json format for DCU batterie
- add hw and sw version
- rename total generation into total charging energy
- rename cell temperature sensors
- restructure json format
- adapt unit tests

* revert changed test packages
2025-04-05 22:30:57 +02:00
9 changed files with 304 additions and 171 deletions

View File

@@ -22,7 +22,16 @@ dev debug:
export IMAGE=$(PRIVAT_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
preview rc rel:
rc:
@[ "${RC}" ] || ( echo ">> RC is not set"; exit 1 )
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
export VERSION=$(VERSION)-$@$(RC) && \
export IMAGE=$(PUBLIC_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
preview rel:
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"

View File

@@ -1,7 +1,7 @@
flake8==7.2.0
pytest==8.3.5
pytest-asyncio==0.26.0
pytest-cov==6.1.0
pytest-cov==6.1.1
python-dotenv==1.1.0
mock==5.2.0
coverage==7.8.0

View File

@@ -19,6 +19,19 @@ class RegisterFunc:
result += prod
return result
@staticmethod
def cmp_values(info: Infos, params: map) -> None | int:
try:
val = info.get_db_value(params['reg'])
if val < params['cmp_val']:
return params['res'][0]
if val == params['cmp_val']:
return params['res'][1]
return params['res'][2]
except Exception:
pass
return None
class RegisterMap:
# make the class read/only by using __slots__
@@ -131,52 +144,54 @@ class RegisterMap:
0x4201000c: {'reg': Register.SENSOR_LIST, 'fmt': '<H', 'func': Fmt.hex4}, # noqa: E501
0x4201001c: {'reg': Register.POWER_ON_TIME, 'fmt': '<H', 'ratio': 1, 'dep': ProxyMode.SERVER}, # noqa: E501, or packet number
0x42010020: {'reg': Register.SERIAL_NUMBER, 'fmt': '!16s'}, # noqa: E501
0x42010030: {'reg': Register.BATT_PV1_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV1 voltage
0x42010032: {'reg': Register.BATT_PV1_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV1 current
0x42010034: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 voltage
0x42010036: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 current
0x42010038: {'reg': Register.BATT_38, 'fmt': '!h'}, # noqa: E501
0x4201003a: {'reg': Register.BATT_TOTAL_GEN, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x4201003c: {'reg': Register.BATT_STATUS_1, 'fmt': '!h'}, # noqa: E501 MPTT-1 Status?
0x4201003e: {'reg': Register.BATT_STATUS_2, 'fmt': '!h'}, # noqa: E501 MPTT-2 Status?
0x42010030: {'reg': Register.BATT_PV1_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Voltage PV1
0x42010032: {'reg': Register.BATT_PV1_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Current PV1
0x42010034: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Voltage PV2
0x42010036: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Current PV2
0x42010038: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
0x4201003c: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-1 Operating Status: 0(Standby), 1(Work)
0x4201003e: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-2 Operating Status: 0(Standby), 1(Work)
0x42010040: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x42010042: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x42010042: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501 => Batterie Status: <0(Discharging), 0(Static), 0>(Loading)
0x42010044: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
0x42010046: {'reg': Register.BATT_CELL1_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010048: {'reg': Register.BATT_CELL2_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201004a: {'reg': Register.BATT_CELL3_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201004c: {'reg': Register.BATT_CELL4_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201004e: {'reg': Register.BATT_CELL5_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010050: {'reg': Register.BATT_CELL6_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010052: {'reg': Register.BATT_CELL7_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010054: {'reg': Register.BATT_CELL8_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010056: {'reg': Register.BATT_CELL9_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010058: {'reg': Register.BATT_CELL10_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201005a: {'reg': Register.BATT_CELL11_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201005c: {'reg': Register.BATT_CELL12_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201005e: {'reg': Register.BATT_CELL13_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010060: {'reg': Register.BATT_CELL14_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010062: {'reg': Register.BATT_CELL15_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010064: {'reg': Register.BATT_CELL16_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010066: {'reg': Register.BATT_TEMP_1, 'fmt': '!h'}, # noqa: E501
0x42010068: {'reg': Register.BATT_TEMP_2, 'fmt': '!h'}, # noqa: E501
0x4201006a: {'reg': Register.BATT_TEMP_3, 'fmt': '!h'}, # noqa: E501
0x4201006c: {'reg': Register.BATT_OUT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x4201006e: {'reg': Register.BATT_OUT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x42010070: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!h'}, # noqa: E501, state of output value 0 or 1
0x42010072: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E501 controller temp
0x42010074: {'reg': Register.BATT_74, 'fmt': '!h'}, # noqa: E501, control input 0..2048
0x42010076: {'reg': Register.BATT_76, 'fmt': '!h'}, # noqa: E501
0x42010078: {'reg': Register.BATT_78, 'fmt': '!h'}, # noqa: E501
0x42010046: {'reg': Register.BATT_CELL1_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010048: {'reg': Register.BATT_CELL2_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x4201004a: {'reg': Register.BATT_CELL3_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x4201004c: {'reg': Register.BATT_CELL4_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x4201004e: {'reg': Register.BATT_CELL5_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010050: {'reg': Register.BATT_CELL6_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010052: {'reg': Register.BATT_CELL7_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010054: {'reg': Register.BATT_CELL8_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010056: {'reg': Register.BATT_CELL9_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010058: {'reg': Register.BATT_CELL10_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x4201005a: {'reg': Register.BATT_CELL11_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x4201005c: {'reg': Register.BATT_CELL12_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x4201005e: {'reg': Register.BATT_CELL13_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010060: {'reg': Register.BATT_CELL14_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010062: {'reg': Register.BATT_CELL15_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x42010064: {'reg': Register.BATT_CELL16_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501H
0x42010066: {'reg': Register.BATT_TEMP_1, 'fmt': '!h'}, # noqa: E501 Cell Temperture 1
0x42010068: {'reg': Register.BATT_TEMP_2, 'fmt': '!h'}, # noqa: E501 Cell Temperture 2
0x4201006a: {'reg': Register.BATT_TEMP_3, 'fmt': '!h'}, # noqa: E501 Cell Temperture 3
0x4201006c: {'reg': Register.BATT_OUT_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 Output Voltage
0x4201006e: {'reg': Register.BATT_OUT_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 Output Current
0x42010070: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!H'}, # noqa: E501 Output Working Status: 0(Standby), 1(Work)
0x42010072: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E50, Environment temp
0x42010074: {'reg': Register.BATT_ALARM, 'fmt': '!H'}, # noqa: E501 Warning Alarmcode 1, Bit 0..15
0x42010076: {'reg': Register.BATT_HW_VERS, 'fmt': '!h'}, # noqa: E501 hardware version
0x42010078: {'reg': Register.BATT_SW_VERS, 'fmt': '!h'}, # noqa: E501 software main version
'calc': {
1: {'reg': Register.BATT_PV_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
1: {'reg': Register.BATT_PV_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Generated Power
'params': [[Register.BATT_PV1_VOLT, Register.BATT_PV1_CUR],
[Register.BATT_PV2_VOLT, Register.BATT_PV2_CUR]]},
2: {'reg': Register.BATT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
'params': [[Register.BATT_VOLT, Register.BATT_CUR]]},
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Supply Power => Power Supply State: 0(Idle), 0>(Power Supply)
'params': [[Register.BATT_OUT_VOLT, Register.BATT_OUT_CUR]]},
4: {'reg': Register.BATT_PWR_SUPL_STATE, 'func': RegisterFunc.cmp_values, # noqa: E501
'params': {'reg': Register.BATT_OUT_PWR, 'cmp_val': 0, 'res': [0, 0, 1]}}, # noqa: E501
5: {'reg': Register.BATT_STATUS, 'func': RegisterFunc.cmp_values, # noqa: E501
'params': {'reg': Register.BATT_CUR, 'cmp_val': 0.0, 'res': [0, 1, 2]}} # noqa: E501
}
}

View File

@@ -125,10 +125,9 @@ class Register(Enum):
BATT_PV1_CUR = 1001
BATT_PV2_VOLT = 1002
BATT_PV2_CUR = 1003
BATT_38 = 1004
BATT_TOTAL_GEN = 1005
BATT_STATUS_1 = 1006
BATT_STATUS_2 = 1007
BATT_TOTAL_CHARG = 1005
BATT_PV1_STATUS = 1006
BATT_PV2_STATUS = 1007
BATT_VOLT = 1010
BATT_CUR = 1011
BATT_SOC = 1012
@@ -155,12 +154,14 @@ class Register(Enum):
BATT_OUT_CUR = 1033
BATT_OUT_STATUS = 1034
BATT_TEMP_4 = 1035
BATT_74 = 1036
BATT_76 = 1037
BATT_78 = 1038
BATT_ALARM = 1036
BATT_HW_VERS = 1037
BATT_SW_VERS = 1038
BATT_PV_PWR = 1040
BATT_PWR = 1041
BATT_OUT_PWR = 1042
BATT_PWR_SUPL_STATE = 1043
BATT_STATUS = 1044
TEST_VAL_0 = 2000
TEST_VAL_1 = 2001
@@ -325,9 +326,11 @@ class Infos:
SOLAR_POWER_VAR = 'mdi:solar-power-variant'
SOLAR_POWER = 'mdi:solar-power'
WIFI = 'mdi:wifi'
ALARM_LIGHT = 'mdi:alarm-light'
UPDATE = 'mdi:update'
DAILY_GEN = 'Daily Generation'
TOTAL_GEN = 'Total Generation'
TOTAL_CHARG = 'Total Charging Energy'
FMT_INT = '| int'
FMT_FLOAT = '| float'
FMT_STRING_SEC = '| string + " s"'
@@ -367,7 +370,7 @@ class Infos:
'input_pv5': {'via': 'inverter', 'name': 'Module PV5', 'mdl': Register.PV5_MODEL, 'mf': Register.PV5_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 5}}, # noqa: E501
'input_pv6': {'via': 'inverter', 'name': 'Module PV6', 'mdl': Register.PV6_MODEL, 'mf': Register.PV6_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 6}}, # noqa: E501
'batterie': {'via': 'controller', 'name': 'Batterie', 'mdl': Register.EQUIPMENT_MODEL, 'mf': Register.MANUFACTURER, 'sw': Register.VERSION, 'sn': Register.SERIAL_NUMBER}, # noqa: E501
'batterie': {'via': 'controller', 'name': 'Batterie', 'mdl': Register.EQUIPMENT_MODEL, 'mf': Register.MANUFACTURER, 'hw': Register.BATT_HW_VERS, 'sw': Register.BATT_SW_VERS, 'sn': Register.SERIAL_NUMBER}, # noqa: E501
'bat_inp_pv1': {'via': 'batterie', 'name': 'Module PV1', 'mdl': Register.PV1_MODEL, 'mf': Register.PV1_MANUFACTURER}, # noqa: E501
'bat_inp_pv2': {'via': 'batterie', 'name': 'Module PV2', 'mdl': Register.PV2_MODEL, 'mf': Register.PV2_MANUFACTURER}, # noqa: E501
}
@@ -375,9 +378,11 @@ class Infos:
__comm_type_val_tpl = "{%set com_types = ['n/a','Wi-Fi', 'G4', 'G5', 'GPRS'] %}{{com_types[value_json['Communication_Type']|int(0)]|default(value_json['Communication_Type'])}}" # noqa: E501
__work_mode_val_tpl = "{%set mode = ['Normal-Mode', 'Aging-Mode', 'ATE-Mode', 'Shielding GFDI', 'DTU-Mode'] %}{{mode[value_json['Work_Mode']|int(0)]|default(value_json['Work_Mode'])}}" # noqa: E501
__status_type_val_tpl = "{%set inv_status = ['Off-line', 'On-grid', 'Off-grid'] %}{{inv_status[value_json['Inverter_Status']|int(0)]|default(value_json['Inverter_Status'])}}" # noqa: E501
__mppt1_status_type_val_tpl = "{%set mppt_status = ['Locked', 'On', 'Off'] %}{{mppt_status[value_json['Status_1']|int(0)]|default(value_json['Status_1'])}}" # noqa: E501
__mppt2_status_type_val_tpl = "{%set mppt_status = ['Locked', 'On', 'Off'] %}{{mppt_status[value_json['Status_2']|int(0)]|default(value_json['Status_2'])}}" # noqa: E501
__out_status_type_val_tpl = "{%set out_status = ['Off', 'On'] %}{{out_status[value_json['out']['Out_Status']|int(0)]|default(value_json['out']['Out_Status'])}}" # noqa: E501
__mppt1_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv1']['MPPT-Status']|int(0)]|default(value_json['pv1']['MPPT-Status'])}}" # noqa: E501
__mppt2_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv2']['MPPT-Status']|int(0)]|default(value_json['pv2']['MPPT-Status'])}}" # noqa: E501
__supply_status_type_val_tpl = "{%set supply_status = ['Idle', 'Power-Supply'] %}{{supply_status[value_json['out']['Suppl_State']|int(0)]|default(value_json['out']['Suppl_State'])}}" # noqa: E501
__batt_status_type_val_tpl = "{%set batt_status = ['Discharging', 'Static', 'Loading'] %}{{batt_status[value_json['batt']['Batt_State']|int(0)]|default(value_json['batt']['Batt_State'])}}" # noqa: E501
__out_status_type_val_tpl = "{%set out_status = ['Standby', 'On'] %}{{out_status[value_json['out']['Out_Status']|int(0)]|default(value_json['out']['Out_Status'])}}" # noqa: E501
__rated_power_val_tpl = "{% if 'Rated_Power' in value_json and value_json['Rated_Power'] != None %}{{value_json['Rated_Power']|string() +' W'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
__designed_power_val_tpl = '''
{% if 'Max_Designed_Power' in value_json and
@@ -399,52 +404,52 @@ class Infos:
{% set result = 'noAlarm'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(1)%}
{% if val_int | bitwise_and(0x0001)%}
{% set result = result + 'HBridgeFault, '%}
{% endif %}
{% if val_int | bitwise_and(2)%}
{% if val_int | bitwise_and(0x0002)%}
{% set result = result + 'DriVoltageFault, '%}
{% endif %}
{% if val_int | bitwise_and(3)%}
{% if val_int | bitwise_and(0x0004)%}
{% set result = result + 'GFDI-Fault, '%}
{% endif %}
{% if val_int | bitwise_and(4)%}
{% if val_int | bitwise_and(0x0008)%}
{% set result = result + 'OverTemp, '%}
{% endif %}
{% if val_int | bitwise_and(5)%}
{% if val_int | bitwise_and(0x0010)%}
{% set result = result + 'CommLose, '%}
{% endif %}
{% if val_int | bitwise_and(6)%}
{% if val_int | bitwise_and(0x0020)%}
{% set result = result + 'Bit6, '%}
{% endif %}
{% if val_int | bitwise_and(7)%}
{% if val_int | bitwise_and(0x0040)%}
{% set result = result + 'Bit7, '%}
{% endif %}
{% if val_int | bitwise_and(8)%}
{% if val_int | bitwise_and(0x0080)%}
{% set result = result + 'EEPROM-Fault, '%}
{% endif %}
{% if val_int | bitwise_and(9)%}
{% if val_int | bitwise_and(0x0100)%}
{% set result = result + 'NoUtility, '%}
{% endif %}
{% if val_int | bitwise_and(10)%}
{% if val_int | bitwise_and(0x0200)%}
{% set result = result + 'VG_Offset, '%}
{% endif %}
{% if val_int | bitwise_and(11)%}
{% if val_int | bitwise_and(0x0400)%}
{% set result = result + 'Relais_Open, '%}
{% endif %}
{% if val_int | bitwise_and(12)%}
{% if val_int | bitwise_and(0x0800)%}
{% set result = result + 'Relais_Short, '%}
{% endif %}
{% if val_int | bitwise_and(13)%}
{% if val_int | bitwise_and(0x1000)%}
{% set result = result + 'GridVoltOverRating, '%}
{% endif %}
{% if val_int | bitwise_and(14)%}
{% if val_int | bitwise_and(0x2000)%}
{% set result = result + 'GridVoltUnderRating, '%}
{% endif %}
{% if val_int | bitwise_and(15)%}
{% if val_int | bitwise_and(0x4000)%}
{% set result = result + 'GridFreqOverRating, '%}
{% endif %}
{% if val_int | bitwise_and(16)%}
{% if val_int | bitwise_and(0x8000)%}
{% set result = result + 'GridFreqUnderRating, '%}
{% endif %}
{% endif %}
@@ -461,42 +466,104 @@ class Infos:
{% set result = 'noFault'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(1)%}
{% if val_int | bitwise_and(0x0001)%}
{% set result = result + 'PVOV-Fault (PV OverVolt), '%}
{% endif %}
{% if val_int | bitwise_and(2)%}
{% if val_int | bitwise_and(0x0002)%}
{% set result = result + 'PVLV-Fault (PV LowVolt), '%}
{% endif %}
{% if val_int | bitwise_and(3)%}
{% if val_int | bitwise_and(0x0004)%}
{% set result = result + 'PV OI-Fault (PV OverCurrent), '%}
{% endif %}
{% if val_int | bitwise_and(4)%}
{% if val_int | bitwise_and(0x0008)%}
{% set result = result + 'PV OFV-Fault, '%}
{% endif %}
{% if val_int | bitwise_and(5)%}
{% if val_int | bitwise_and(0x0010)%}
{% set result = result + 'DC ShortCircuitFault, '%}
{% endif %}
{% if val_int | bitwise_and(6)%}{% set result = result + 'Bit6, '%}
{% if val_int | bitwise_and(0x0020)%}{% set result = result + 'Bit6, '%}
{% endif %}
{% if val_int | bitwise_and(7)%}{% set result = result + 'Bit7, '%}
{% if val_int | bitwise_and(0x0040)%}{% set result = result + 'Bit7, '%}
{% endif %}
{% if val_int | bitwise_and(8)%}{% set result = result + 'Bit8, '%}
{% if val_int | bitwise_and(0x0080)%}{% set result = result + 'Bit8, '%}
{% endif %}
{% if val_int | bitwise_and(9)%}{% set result = result + 'Bit9, '%}
{% if val_int | bitwise_and(0x0100)%}{% set result = result + 'Bit9, '%}
{% endif %}
{% if val_int | bitwise_and(10)%}{% set result = result + 'Bit10, '%}
{% if val_int | bitwise_and(0x0200)%}{% set result = result + 'Bit10, '%}
{% endif %}
{% if val_int | bitwise_and(11)%}{% set result = result + 'Bit11, '%}
{% if val_int | bitwise_and(0x0400)%}{% set result = result + 'Bit11, '%}
{% endif %}
{% if val_int | bitwise_and(12)%}{% set result = result + 'Bit12, '%}
{% if val_int | bitwise_and(0x0800)%}{% set result = result + 'Bit12, '%}
{% endif %}
{% if val_int | bitwise_and(13)%}{% set result = result + 'Bit13, '%}
{% if val_int | bitwise_and(0x1000)%}{% set result = result + 'Bit13, '%}
{% endif %}
{% if val_int | bitwise_and(14)%}{% set result = result + 'Bit14, '%}
{% if val_int | bitwise_and(0x2000)%}{% set result = result + 'Bit14, '%}
{% endif %}
{% if val_int | bitwise_and(15)%}{% set result = result + 'Bit15, '%}
{% if val_int | bitwise_and(0x4000)%}{% set result = result + 'Bit15, '%}
{% endif %}
{% if val_int | bitwise_and(16)%}{% set result = result + 'Bit16, '%}
{% if val_int | bitwise_and(0x8000)%}{% set result = result + 'Bit16, '%}
{% endif %}
{% endif %}
{{ result }}
{% else %}
{{ this.state }}
{% endif %}
'''
__batt_alarm_val_tpl = '''
{% if 'Batterie_Alarm' in value_json and
value_json['Batterie_Alarm'] != None %}
{% set val_int = value_json['Batterie_Alarm'] | int %}
{% if val_int == 0 %}
{% set result = 'noAlarm'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(0x0001)%}
{% set result = result + 'PV1-OverVoltage, '%}
{% endif %}
{% if val_int | bitwise_and(0x0002)%}
{% set result = result + 'PV2-OverVoltage, '%}
{% endif %}
{% if val_int | bitwise_and(0x0004)%}
{% set result = result + 'EquipmentOverheating, '%}
{% endif %}
{% if val_int | bitwise_and(0x0008)%}
{% set result = result + 'EquipmentLowTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0010)%}
{% set result = result + 'BMS-CommFailed, '%}
{% endif %}
{% if val_int | bitwise_and(0x0020)%}
{% set result = result + 'UnderVoltageProt, '%}
{% endif %}
{% if val_int | bitwise_and(0x0040)%}
{% set result = result + 'ChargingHighTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0080)%}
{% set result = result + 'ChargingLowTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0100)%}
{% set result = result + 'DischargeHighTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0200)%}
{% set result = result + 'DischargeLowTemp, '%}
{% endif %}
{% if val_int | bitwise_and(0x0400)%}
{% set result = result + 'BatterieOverVoltage, '%}
{% endif %}
{% if val_int | bitwise_and(0x0800)%}
{% set result = result + 'SingleCorePressureDifferenceIsTooLarge, '%}
{% endif %}
{% if val_int | bitwise_and(0x1000)%}
{% set result = result + 'Bit-12, '%}
{% endif %}
{% if val_int | bitwise_and(0x2000)%}
{% set result = result + 'Bit-13, '%}
{% endif %}
{% if val_int | bitwise_and(0x4000)%}
{% set result = result + 'Bit-14, '%}
{% endif %}
{% if val_int | bitwise_and(0x8000)%}
{% set result = result + 'Bit-15, '%}
{% endif %}
{% endif %}
{{ result }}
@@ -562,8 +629,8 @@ class Infos:
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':FMT_FLOAT,'name': 'Grid Voltage'}}, # noqa: E501
# events
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
Register.EVENT_BF1: {'name': ['events', 'Inverter_Bitfield_1'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.EVENT_BF2: {'name': ['events', 'Inverter_bitfield_2'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
# Register.EVENT_409: {'name': ['events', '409_No_Utility'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
@@ -636,46 +703,53 @@ class Infos:
Register.PROD_COMPL_TYPE: {'name': ['other', 'Prod_Compliance_Type'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
# Batterie DC-1000: Electricity Genration
Register.BATT_PV1_STATUS: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV1_VOLT: {'name': ['batterie', 'pv1', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV1_CUR: {'name': ['batterie', 'pv1', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV2_STATUS: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV2_VOLT: {'name': ['batterie', 'pv2', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV2_CUR: {'name': ['batterie', 'pv2', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_38: {'name': ['batterie', 'Reg_38'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_38_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TOTAL_GEN: {'name': ['batterie', 'Total_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'batterie', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_', 'fmt': FMT_FLOAT, 'name': TOTAL_GEN, 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
Register.BATT_STATUS_1: {'name': ['batterie', 'Status_1'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_STATUS_2: {'name': ['batterie', 'Status_2'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_VOLT: {'name': ['batterie', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_bat_', 'fmt': FMT_FLOAT, 'name': 'Batterie Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CUR: {'name': ['batterie', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_bat_', 'fmt': FMT_FLOAT, 'name': 'Batterie Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_SOC: {'name': ['batterie', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'fmt': FMT_FLOAT, 'name': 'State of Charge (SOC)', 'icon': 'mdi:battery-90'}}, # noqa: E501
Register.BATT_CELL1_VOLT: {'name': ['batterie', 'Cell', 'Volt1'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell1_', 'val_tpl': "{{ (value_json['Cell']['Volt1'] | float)}}", 'name': 'Cell-01 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL3_VOLT: {'name': ['batterie', 'Cell', 'Volt3'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell3_', 'val_tpl': "{{ (value_json['Cell']['Volt2'] | float)}}", 'name': 'Cell-03 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL4_VOLT: {'name': ['batterie', 'Cell', 'Volt4'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell4_', 'val_tpl': "{{ (value_json['Cell']['Volt3'] | float)}}", 'name': 'Cell-04 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL2_VOLT: {'name': ['batterie', 'Cell', 'Volt2'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell2_', 'val_tpl': "{{ (value_json['Cell']['Volt4'] | float)}}", 'name': 'Cell-02 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL5_VOLT: {'name': ['batterie', 'Cell', 'Volt5'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell5_', 'val_tpl': "{{ (value_json['Cell']['Volt5'] | float)}}", 'name': 'Cell-05 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL6_VOLT: {'name': ['batterie', 'Cell', 'Volt6'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell6_', 'val_tpl': "{{ (value_json['Cell']['Volt6'] | float)}}", 'name': 'Cell-06 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL7_VOLT: {'name': ['batterie', 'Cell', 'Volt7'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell7_', 'val_tpl': "{{ (value_json['Cell']['Volt7'] | float)}}", 'name': 'Cell-07 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL8_VOLT: {'name': ['batterie', 'Cell', 'Volt8'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell8_', 'val_tpl': "{{ (value_json['Cell']['Volt8'] | float)}}", 'name': 'Cell-08 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL9_VOLT: {'name': ['batterie', 'Cell', 'Volt9'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell9_', 'val_tpl': "{{ (value_json['Cell']['Volt9'] | float)}}", 'name': 'Cell-09 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL10_VOLT: {'name': ['batterie', 'Cell', 'Volt10'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell10_', 'val_tpl': "{{ (value_json['Cell']['Volt10'] | float)}}", 'name': 'Cell-10 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL11_VOLT: {'name': ['batterie', 'Cell', 'Volt11'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell11_', 'val_tpl': "{{ (value_json['Cell']['Volt11'] | float)}}", 'name': 'Cell-11 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL12_VOLT: {'name': ['batterie', 'Cell', 'Volt12'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell12_', 'val_tpl': "{{ (value_json['Cell']['Volt12'] | float)}}", 'name': 'Cell-12 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL13_VOLT: {'name': ['batterie', 'Cell', 'Volt13'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell13_', 'val_tpl': "{{ (value_json['Cell']['Volt13'] | float)}}", 'name': 'Cell-13 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL14_VOLT: {'name': ['batterie', 'Cell', 'Volt14'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell14_', 'val_tpl': "{{ (value_json['Cell']['Volt14'] | float)}}", 'name': 'Cell-14 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL15_VOLT: {'name': ['batterie', 'Cell', 'Volt15'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell15_', 'val_tpl': "{{ (value_json['Cell']['Volt15'] | float)}}", 'name': 'Cell-15 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL16_VOLT: {'name': ['batterie', 'Cell', 'Volt16'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell16_', 'val_tpl': "{{ (value_json['Cell']['Volt16'] | float)}}", 'name': 'Cell-16 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_1: {'name': ['batterie', 'Temp_1'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_1_', 'fmt': FMT_INT, 'name': 'Batterie Temp-1', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_2: {'name': ['batterie', 'Temp_2'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_2_', 'fmt': FMT_INT, 'name': 'Batterie Temp-2', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_3: {'name': ['batterie', 'Temp_3'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_3_', 'fmt': FMT_INT, 'name': 'Batterie Temp-3', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV_PWR: {'name': ['batterie', 'PV_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'pv_power_', 'fmt': FMT_INT, 'name': 'PV Power'}}, # noqa: E501
Register.BATT_OUT_STATUS: {'name': ['batterie', 'out', 'Out_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'out_status_', 'name': 'Output Status', 'val_tpl': __out_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_OUT_VOLT: {'name': ['batterie', 'out', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'val_tpl': "{{ (value_json['out']['Voltage'] | float)}}", 'name': 'Output Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_OUT_CUR: {'name': ['batterie', 'out', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'val_tpl': "{{ (value_json['out']['Current'] | float)}}", 'name': 'Output Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_OUT_STATUS: {'name': ['batterie', 'out', 'Out_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'out_status_', 'name': 'Output Status', 'val_tpl': __out_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_TEMP_4: {'name': ['batterie', 'Controller_Temp'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_4_', 'fmt': FMT_INT, 'name': 'Ctrl Temperature'}}, # noqa: E501
Register.BATT_74: {'name': ['batterie', 'Reg_74'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_74_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_76: {'name': ['batterie', 'Reg_76'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_76_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_78: {'name': ['batterie', 'Reg_78'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_78_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV_PWR: {'name': ['batterie', 'PV_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'pv_power_', 'fmt': FMT_INT, 'name': 'PV Power'}}, # noqa: E501
Register.BATT_PWR: {'name': ['batterie', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_', 'fmt': FMT_INT, 'name': 'Batterie Power'}}, # noqa: E501
Register.BATT_OUT_PWR: {'name': ['batterie', 'out', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'val_tpl': "{{ (value_json['out']['Power'] | int)}}", 'name': 'Output Power'}}, # noqa: E501
Register.BATT_OUT_PWR: {'name': ['batterie', 'out', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'val_tpl': "{{ (value_json['out']['Power'] | int)}}", 'name': 'Supply Power'}}, # noqa: E501
Register.BATT_PWR_SUPL_STATE: {'name': ['batterie', 'out', 'Suppl_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_supply_', 'name': 'Supply State', 'val_tpl': __supply_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
# Batterie DC-1000: Cell Package
Register.BATT_CELL1_VOLT: {'name': ['batterie', 'cell', 'Volt1'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell1_', 'val_tpl': "{{ (value_json['cell']['Volt1'] | float)}}", 'name': 'Cell-01 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL3_VOLT: {'name': ['batterie', 'cell', 'Volt3'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell3_', 'val_tpl': "{{ (value_json['cell']['Volt2'] | float)}}", 'name': 'Cell-03 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL4_VOLT: {'name': ['batterie', 'cell', 'Volt4'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell4_', 'val_tpl': "{{ (value_json['cell']['Volt3'] | float)}}", 'name': 'Cell-04 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL2_VOLT: {'name': ['batterie', 'cell', 'Volt2'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell2_', 'val_tpl': "{{ (value_json['cell']['Volt4'] | float)}}", 'name': 'Cell-02 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL5_VOLT: {'name': ['batterie', 'cell', 'Volt5'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell5_', 'val_tpl': "{{ (value_json['cell']['Volt5'] | float)}}", 'name': 'Cell-05 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL6_VOLT: {'name': ['batterie', 'cell', 'Volt6'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell6_', 'val_tpl': "{{ (value_json['cell']['Volt6'] | float)}}", 'name': 'Cell-06 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL7_VOLT: {'name': ['batterie', 'cell', 'Volt7'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell7_', 'val_tpl': "{{ (value_json['cell']['Volt7'] | float)}}", 'name': 'Cell-07 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL8_VOLT: {'name': ['batterie', 'cell', 'Volt8'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell8_', 'val_tpl': "{{ (value_json['cell']['Volt8'] | float)}}", 'name': 'Cell-08 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL9_VOLT: {'name': ['batterie', 'cell', 'Volt9'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell9_', 'val_tpl': "{{ (value_json['cell']['Volt9'] | float)}}", 'name': 'Cell-09 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL10_VOLT: {'name': ['batterie', 'cell', 'Volt10'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell10_', 'val_tpl': "{{ (value_json['cell']['Volt10'] | float)}}", 'name': 'Cell-10 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL11_VOLT: {'name': ['batterie', 'cell', 'Volt11'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell11_', 'val_tpl': "{{ (value_json['cell']['Volt11'] | float)}}", 'name': 'Cell-11 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL12_VOLT: {'name': ['batterie', 'cell', 'Volt12'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell12_', 'val_tpl': "{{ (value_json['cell']['Volt12'] | float)}}", 'name': 'Cell-12 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL13_VOLT: {'name': ['batterie', 'cell', 'Volt13'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell13_', 'val_tpl': "{{ (value_json['cell']['Volt13'] | float)}}", 'name': 'Cell-13 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL14_VOLT: {'name': ['batterie', 'cell', 'Volt14'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell14_', 'val_tpl': "{{ (value_json['cell']['Volt14'] | float)}}", 'name': 'Cell-14 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL15_VOLT: {'name': ['batterie', 'cell', 'Volt15'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell15_', 'val_tpl': "{{ (value_json['cell']['Volt15'] | float)}}", 'name': 'Cell-15 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CELL16_VOLT: {'name': ['batterie', 'cell', 'Volt16'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell16_', 'val_tpl': "{{ (value_json['cell']['Volt16'] | float)}}", 'name': 'Cell-16 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
# Batterie DC-1000: Batterie Pack
Register.BATT_VOLT: {'name': ['batterie', 'batt', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_bat_', 'val_tpl': "{{ (value_json['batt']['Voltage'] | float)}}", 'name': 'Batterie Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_CUR: {'name': ['batterie', 'batt', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_bat_', 'val_tpl': "{{ (value_json['batt']['Current'] | float)}}", 'name': 'Batterie Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PWR: {'name': ['batterie', 'batt', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_', 'val_tpl': "{{ (value_json['batt']['Power'] | int)}}", 'name': 'Batterie Power'}}, # noqa: E501
Register.BATT_SOC: {'name': ['batterie', 'batt', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'val_tpl': "{{ (value_json['batt']['SOC'] | float)}}", 'name': 'State of Charge (SOC)', 'icon': 'mdi:battery-90'}}, # noqa: E501
Register.BATT_TOTAL_CHARG: {'name': ['batterie', 'batt', 'Total_Charging'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'batterie', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_charg_', 'val_tpl': "{{ (value_json['batt']['Total_Charging'] | float)}}", 'name': TOTAL_CHARG, 'icon': 'mdi:battery-charging', 'must_incr': True}}, # noqa: E501
Register.BATT_STATUS: {'name': ['batterie', 'batt', 'Batt_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_batt_', 'name': 'Batterie State', 'val_tpl': __batt_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_TEMP_1: {'name': ['batterie', 'cell', 'Temp_1'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_1_', 'val_tpl': "{{ (value_json['cell']['Temp_1'] | int)}}", 'name': 'Cell Temp-1', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_2: {'name': ['batterie', 'cell', 'Temp_2'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_2_', 'val_tpl': "{{ (value_json['cell']['Temp_2'] | int)}}", 'name': 'Cell Temp-2', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_3: {'name': ['batterie', 'cell', 'Temp_3'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_3_', 'val_tpl': "{{ (value_json['cell']['Temp_3'] | int)}}", 'name': 'Cell Temp-3', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_4: {'name': ['batterie', 'Controller_Temp'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_4_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501
Register.BATT_ALARM: {'name': ['batterie', 'Batterie_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'batt_alarm_', 'name': 'Batterie Alarm', 'val_tpl': __batt_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
Register.BATT_HW_VERS: {'name': ['batterie', 'Hardware_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.BATT_SW_VERS: {'name': ['batterie', 'Software_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.TEST_VAL_0: {'name': ['input', 'Val_0'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_0_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.TEST_VAL_1: {'name': ['input', 'Val_1'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_1_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501

View File

@@ -42,39 +42,38 @@ class Modbus():
0x0009: {'reg': Register.BATT_PV1_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV1 current
0x000a: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 voltage
0x000b: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 current
0x000c: {'reg': Register.BATT_38, 'fmt': '!h'}, # noqa: E501
0x000d: {'reg': Register.BATT_TOTAL_GEN, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x000e: {'reg': Register.BATT_STATUS_1, 'fmt': '!h'}, # noqa: E501
0x000f: {'reg': Register.BATT_STATUS_2, 'fmt': '!h'}, # noqa: E501
0x000c: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
0x000e: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501
0x000f: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501
0x0010: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x0011: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x0012: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
0x0013: {'reg': Register.BATT_CELL1_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0014: {'reg': Register.BATT_CELL2_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0015: {'reg': Register.BATT_CELL3_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0016: {'reg': Register.BATT_CELL4_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0017: {'reg': Register.BATT_CELL5_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0018: {'reg': Register.BATT_CELL6_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0019: {'reg': Register.BATT_CELL7_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x001a: {'reg': Register.BATT_CELL8_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x001b: {'reg': Register.BATT_CELL9_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x001c: {'reg': Register.BATT_CELL10_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x001d: {'reg': Register.BATT_CELL11_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x001e: {'reg': Register.BATT_CELL12_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x001f: {'reg': Register.BATT_CELL13_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0020: {'reg': Register.BATT_CELL14_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0021: {'reg': Register.BATT_CELL15_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0022: {'reg': Register.BATT_CELL16_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x0013: {'reg': Register.BATT_CELL1_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0014: {'reg': Register.BATT_CELL2_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0015: {'reg': Register.BATT_CELL3_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0016: {'reg': Register.BATT_CELL4_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0017: {'reg': Register.BATT_CELL5_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0018: {'reg': Register.BATT_CELL6_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0019: {'reg': Register.BATT_CELL7_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x001a: {'reg': Register.BATT_CELL8_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x001b: {'reg': Register.BATT_CELL9_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x001c: {'reg': Register.BATT_CELL10_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x001d: {'reg': Register.BATT_CELL11_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x001e: {'reg': Register.BATT_CELL12_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x001f: {'reg': Register.BATT_CELL13_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0020: {'reg': Register.BATT_CELL14_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0021: {'reg': Register.BATT_CELL15_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0022: {'reg': Register.BATT_CELL16_VOLT, 'fmt': '!H', 'ratio': 0.001}, # noqa: E501
0x0023: {'reg': Register.BATT_TEMP_1, 'fmt': '!h'}, # noqa: E501
0x0024: {'reg': Register.BATT_TEMP_2, 'fmt': '!h'}, # noqa: E501
0x0025: {'reg': Register.BATT_TEMP_3, 'fmt': '!h'}, # noqa: E501
0x0026: {'reg': Register.BATT_OUT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x0027: {'reg': Register.BATT_OUT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x0028: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!h'}, # noqa: E501
0x0026: {'reg': Register.BATT_OUT_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
0x0027: {'reg': Register.BATT_OUT_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
0x0028: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!H'}, # noqa: E501
0x0029: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E501
0x002a: {'reg': Register.BATT_74, 'fmt': '!h'}, # noqa: E501
0x002b: {'reg': Register.BATT_76, 'fmt': '!h'}, # noqa: E501
0x002c: {'reg': Register.BATT_78, 'fmt': '!h'}, # noqa: E501
0x002a: {'reg': Register.BATT_ALARM, 'fmt': '!h'}, # noqa: E501
0x002b: {'reg': Register.BATT_HW_VERS, 'fmt': '!h'}, # noqa: E501
0x002c: {'reg': Register.BATT_SW_VERS, 'fmt': '!h'}, # noqa: E501
0x2000: {'reg': Register.BOOT_STATUS, 'fmt': '!H'}, # noqa: E501
0x2001: {'reg': Register.DSP_STATUS, 'fmt': '!H'}, # noqa: E501

View File

@@ -221,7 +221,7 @@ def inv_data_seq2(): # Data indication from the controller
return msg
@pytest.fixture
def inv_data_seq3(): # Inverter indication from MS-2000
def inv_data_seq3(): # Inverter indication from MS-3000
msg = b'\x00\x00\x01\x2c\x00\x00\x00\x64\x53\x00\x00' # | ..^.....,...dS..
msg += b'\x00\x00\x00\xc8\x53\x44\x00\x00\x00\x01\x2c\x53\x00\x00\x00\x00' # | ....SD....,S....

View File

@@ -82,13 +82,25 @@ def batterie_data(): # 0x4210 ftype: 0x01
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
return msg
@pytest.fixture
def batterie_data1(): # 0x4210 ftype: 0x01
msg = b'\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01\x26\x30\xc7\xde'
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
msg += b'\x34\x31\x30\x31\x32\x34\x30\x37\x30\x31\x34\x39\x30\x33\x31\x34'
msg += b'\x0d\x3a\x00\x70\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
msg += b'\x01\x00\x00\x00\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x0c\x0e\x01\x00'
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
return msg
@pytest.fixture
def batterie_data2(): # 0x4210 ftype: 0x01
msg = b'\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01\x26\x30\xc7\xde'
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
msg += b'\x34\x31\x30\x31\x32\x34\x30\x37\x30\x31\x34\x39\x30\x33\x31\x34'
msg += b'\x0d\x3a\x00\x70\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
msg += b'\x14\x0e\xff\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x14\x0e\x02\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e'
return msg
@@ -155,15 +167,32 @@ def test_parse_4210_3026(batterie_data: bytes):
assert json.dumps(i.db) == json.dumps({
"controller": {"Sensor_List": "3026", "Power_On_Time": 4684},
"inverter": {"Serial_Number": "4101240701490314"},
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12},
"pv2": {"Voltage": 33.72, "Current": 0.0},
"Reg_38": 0, "Total_Generation": 20.8, "Status_1": 0, "Status_2": 0,
"Voltage": 51.34, "Current": -0.02, "SOC": 10.0,
"Cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21},
"Temp_1": 15, "Temp_2": 15, "Temp_3": 15,
"out": {"Voltage": 0.14, "Current": 0.0, "Out_Status": 0, "Power": 0.0},
"Controller_Temp": 15, "Reg_74": 0, "Reg_76": 517, "Reg_78": 513,
"PV_Power": 37.9232, "Power": -1.0268000000000002},
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": -0.02, "SOC": 10.0, "Power": -1.0268000000000002, 'Batt_State': 0},
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
"out": {"Voltage": 0.14, "Current": 0.0, "Out_Status": 0, "Power": 0.0, "Suppl_State": 0},
"Controller_Temp": 15, "Batterie_Alarm": 0, "Hardware_Version": 517, "Software_Version": 513,
"PV_Power": 37.9232},
})
def test_parse_4210_3026_prod(batterie_data1: bytes):
i = InfosG3P(client_mode=False)
i.db.clear()
for key, update in i.parse (batterie_data1, 0x42, 1, 0x3026):
pass # side effect is calling generator i.parse()
assert json.dumps(i.db) == json.dumps({
"controller": {"Sensor_List": "3026", "Power_On_Time": 4684},
"inverter": {"Serial_Number": "4101240701490314"},
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
"batt": {"Total_Charging": 20.8, "Voltage": 2.56, "Current": 0.0, "SOC": 10.0, "Power": 0.0, 'Batt_State': 1},
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
"out": {"Voltage": 30.86, "Current": 2.56, "Out_Status": 0, "Power": 79.0016, "Suppl_State": 1},
"Controller_Temp": 15, "Batterie_Alarm": 0, "Hardware_Version": 517, "Software_Version": 513,
"PV_Power": 37.9232},
})
def test_parse_4210_3026_incomplete(batterie_data2: bytes):
@@ -176,16 +205,14 @@ def test_parse_4210_3026_incomplete(batterie_data2: bytes):
assert json.dumps(i.db) == json.dumps({
"controller": {"Sensor_List": "3026", "Power_On_Time": 4684},
"inverter": {"Serial_Number": "4101240701490314"},
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12},
"pv2": {"Voltage": 33.72, "Current": 0.0},
"Reg_38": 0, "Total_Generation": 20.8, "Status_1": 0, "Status_2": 0,
"Voltage": 51.34, "Current": -0.02, "SOC": 10.0,
"Cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21},
"Temp_1": 15, "Temp_2": 15, "Temp_3": 15,
"out": {"Voltage": 0.14, "Current": None, "Out_Status": None, "Power": None},
"Controller_Temp": None, "Reg_74": None, "Reg_76": None, "Reg_78": None,
"PV_Power": 37.9232, "Power": -1.0268000000000002},
})
"batterie": {"pv1": {"Voltage": 33.86, "Current": 1.12, "MPPT-Status": 0},
"pv2": {"Voltage": 33.72, "Current": 0.0, "MPPT-Status": 0},
"batt": {"Total_Charging": 20.8, "Voltage": 51.34, "Current": 7.66, "SOC": 10.0, "Power": 393.2644, 'Batt_State': 2},
"cell": {"Volt1": 3.21, "Volt2": 3.21, "Volt3": 3.21, "Volt4": 3.21, "Volt5": 3.21, "Volt6": 3.21, "Volt7": 3.21, "Volt8": 3.21, "Volt9": 3.21, "Volt10": 3.21, "Volt11": 3.21, "Volt12": 3.21, "Volt13": 3.21, "Volt14": 3.21, "Volt15": 3.21, "Volt16": 3.21, "Temp_1": 15, "Temp_2": 15, "Temp_3": 15},
"out": {"Voltage": 0.14, "Current": None, "Out_Status": None, "Power": None, "Suppl_State": None},
"Controller_Temp": None, "Batterie_Alarm": None, "Hardware_Version": None, "Software_Version": None,
"PV_Power": 37.9232},
})
def test_build_4210(inverter_data: bytes):
i = InfosG3P(client_mode=False)
@@ -359,7 +386,7 @@ def test_build_ha_conf5():
if id == 'out_power_123':
assert comp == 'sensor'
assert d_json == json.dumps({"name": "Output Power", "stat_t": "tsun/garagendach/batterie", "dev_cla": "power", "stat_cla": "measurement", "uniq_id": "out_power_123", "val_tpl": "{{ (value_json['out']['Power'] | int)}}", "unit_of_meas": "W", "dev": {"name": "Batterie", "sa": "Batterie", "via_device": "controller_123", "mdl": "TSOL-MSxx00", "mf": "TSUN", "ids": ["batterie_123"]}, "o": {"name": "proxy", "sw": "unknown"}})
assert d_json == json.dumps({"name": "Supply Power", "stat_t": "tsun/garagendach/batterie", "dev_cla": "power", "stat_cla": "measurement", "uniq_id": "out_power_123", "val_tpl": "{{ (value_json['out']['Power'] | int)}}", "unit_of_meas": "W", "dev": {"name": "Batterie", "sa": "Batterie", "via_device": "controller_123", "mdl": "TSOL-MSxx00", "mf": "TSUN", "ids": ["batterie_123"]}, "o": {"name": "proxy", "sw": "unknown"}})
tests +=1
elif id == 'daily_gen_123':
assert False

View File

@@ -47,7 +47,16 @@ dev debug: local_add_on
export IMAGE=$(PRIVAT_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
rc rel: local_add_on
rc: local_add_on
@[ "${RC}" ] || ( echo ">> RC is not set"; exit 1 )
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"
export VERSION=$(VERSION)-$@$(RC) && \
export IMAGE=$(PUBLIC_CONTAINER_REGISTRY)$(IMAGE) && \
docker buildx bake -f docker-bake.hcl $@
rel: local_add_on
@echo version: $(VERSION) build-date: $(BUILD_DATE) image: $(PUBLIC_CONTAINER_REGISTRY)$(IMAGE)
@echo login at $(PUBLIC_URL) as $(PUBLIC_USER)
@DO_LOGIN="$(shell echo $(PUBLIC_CR_KEY) | docker login $(PUBLIC_URL) -u $(PUBLIC_USER) --password-stdin)"

View File

@@ -6,7 +6,7 @@ from dotenv import load_dotenv
load_dotenv()
SOLARMAN_INV_SNR = os.getenv('SOLARMAN_INV_SNR', '00000080')
SOLARMAN_DCU_SNR = os.getenv('SOLARMAN_INV_SNR', '00000080')
SOLARMAN_DCU_SNR = os.getenv('SOLARMAN_DCU_SNR', '00000080')
def get_sn() -> bytes:
return bytes.fromhex(SOLARMAN_INV_SNR)
@@ -153,9 +153,9 @@ def dcu_data_ind_msg(): # 0x4210
msg += b'\x2d\x32\x28\x00\x00\x00\x84\x17\x79\x35\x01\x00\x4c\x12\x00\x00'
msg += get_dcu_no()
msg += b'\x0d\x3a\x00\x0a\x0d\x2c\x00\x00\x00\x00\x08\x20\x00\x00\x00\x00'
msg += b'\x14\x0e\xff\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x14\x0e\x05\xfe\x03\xe8\x0c\x89\x0c\x89\x0c\x89\x0c\x8a\x0c\x89'
msg += b'\x0c\x89\x0c\x8a\x0c\x89\x0c\x89\x0c\x8a\x0c\x8a\x0c\x89\x0c\x89'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e\x00\x00'
msg += b'\x0c\x89\x0c\x89\x0c\x88\x00\x0f\x00\x0f\x00\x0f\x00\x0e\x02\x00'
msg += b'\x00\x00\x00\x0f\x00\x00\x02\x05\x02\x01'
msg += correct_checksum(msg)
msg += b'\x15'