@@ -247,6 +247,7 @@ class SolarmanBase(Message):
|
||||
class SolarmanV5(SolarmanBase):
|
||||
AT_CMD = 1
|
||||
MB_RTU_CMD = 2
|
||||
DCU_CMD = 5
|
||||
AT_CMD_RSP = 8
|
||||
MB_CLIENT_DATA_UP = 30
|
||||
'''Data up time in client mode'''
|
||||
@@ -532,6 +533,24 @@ class SolarmanV5(SolarmanBase):
|
||||
except Exception:
|
||||
self.ifc.tx_clear()
|
||||
|
||||
def send_dcu_cmd(self, pdu: bytearray):
|
||||
if self.sensor_list != 0x3026:
|
||||
logger.debug(f'[{self.node_id}] DCU CMD not allowed,'
|
||||
f' for sensor: {self.sensor_list:#04x}')
|
||||
return
|
||||
|
||||
if self.state != State.up:
|
||||
logger.warning(f'[{self.node_id}] ignore DCU CMD,'
|
||||
' cause the state is not UP anymore')
|
||||
return
|
||||
self._build_header(0x4510)
|
||||
self.ifc.tx_add(struct.pack('<BHLLL', self.DCU_CMD,
|
||||
self.sensor_list, 0, 0, 0))
|
||||
self.ifc.tx_add(pdu)
|
||||
self._finish_send_msg()
|
||||
self.ifc.tx_log(logging.INFO, f'Send DCU CMD :{self.addr}:')
|
||||
self.ifc.tx_flush()
|
||||
|
||||
def __forward_msg(self):
|
||||
self.forward(self.ifc.rx_peek(), self.header_len+self.data_len+2)
|
||||
|
||||
|
||||
@@ -2,6 +2,7 @@ import asyncio
|
||||
import logging
|
||||
import aiomqtt
|
||||
import traceback
|
||||
import struct
|
||||
|
||||
from modbus import Modbus
|
||||
from messages import Message
|
||||
@@ -32,6 +33,7 @@ class Mqtt(metaclass=Singleton):
|
||||
self.ha_status_topic = f"{ha['auto_conf_prefix']}/status"
|
||||
self.mb_rated_topic = f"{ha['entity_prefix']}/+/rated_load"
|
||||
self.mb_out_coeff_topic = f"{ha['entity_prefix']}/+/out_coeff"
|
||||
self.dcu_power_topic = f"{ha['entity_prefix']}/+/dcu_power"
|
||||
self.mb_reads_topic = f"{ha['entity_prefix']}/+/modbus_read_regs"
|
||||
self.mb_inputs_topic = f"{ha['entity_prefix']}/+/modbus_read_inputs"
|
||||
self.mb_at_cmd_topic = f"{ha['entity_prefix']}/+/at_cmd"
|
||||
@@ -85,6 +87,7 @@ class Mqtt(metaclass=Singleton):
|
||||
await self.__client.subscribe(self.ha_status_topic)
|
||||
await self.__client.subscribe(self.mb_rated_topic)
|
||||
await self.__client.subscribe(self.mb_out_coeff_topic)
|
||||
await self.__client.subscribe(self.dcu_power_topic)
|
||||
await self.__client.subscribe(self.mb_reads_topic)
|
||||
await self.__client.subscribe(self.mb_inputs_topic)
|
||||
await self.__client.subscribe(self.mb_at_cmd_topic)
|
||||
@@ -148,6 +151,21 @@ class Mqtt(metaclass=Singleton):
|
||||
except Exception:
|
||||
pass
|
||||
|
||||
if message.topic.matches(self.dcu_power_topic):
|
||||
payload = message.payload.decode("UTF-8")
|
||||
try:
|
||||
val = round(float(payload) * 10)
|
||||
if val < 1000 or val > 8000:
|
||||
logger_mqtt.error('dcu_power: value must be in'
|
||||
'the range 100..800,'
|
||||
f' got: {payload}')
|
||||
else:
|
||||
pdu = struct.pack('>BBBBBBH', 1, 1, 6, 1, 0, 1, val)
|
||||
for fnc in self.each_inverter(message, "send_dcu_cmd"):
|
||||
fnc(pdu)
|
||||
except Exception:
|
||||
pass
|
||||
|
||||
if message.topic.matches(self.mb_reads_topic):
|
||||
await self.modbus_cmd(message,
|
||||
Modbus.READ_REGS, 2)
|
||||
|
||||
Reference in New Issue