cleanup
- chance log level from INFO to DEBUG - remove experimental value Register.VALUE_1 - format Register.POWER_ON_TIME as integer
This commit is contained in:
@@ -145,7 +145,7 @@ class Infos:
|
||||
|
||||
@classmethod
|
||||
def static_init(cls):
|
||||
logging.info('Initialize proxy statistics')
|
||||
logging.debug('Initialize proxy statistics')
|
||||
# init proxy counter in the class.stat dictionary
|
||||
cls.stat['proxy'] = {}
|
||||
for key in cls.__info_defs:
|
||||
@@ -245,7 +245,6 @@ class Infos:
|
||||
Register.GRID_FREQUENCY: {'name': ['grid', 'Frequency'], 'level': logging.DEBUG, 'unit': 'Hz', 'ha': {'dev': 'inverter', 'dev_cla': 'frequency', 'stat_cla': 'measurement', 'id': 'out_freq_', 'fmt': '| float', 'name': 'Grid Frequency', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.OUTPUT_POWER: {'name': ['grid', 'Output_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'fmt': '| float', 'name': 'Power'}}, # noqa: E501
|
||||
Register.INVERTER_TEMP: {'name': ['env', 'Inverter_Temp'], 'level': logging.DEBUG, 'unit': '°C', 'ha': {'dev': 'inverter', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_', 'fmt': '| int', 'name': 'Temperature'}}, # noqa: E501
|
||||
Register.VALUE_1: {'name': ['env', 'Value_1'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'value_1_', 'fmt': '| int', 'name': 'Value 1', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INVERTER_STATUS: {'name': ['env', 'Inverter_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_status_', 'name': 'Inverter Status', 'val_tpl': __status_type_val_tpl, 'icon': 'mdi:counter'}}, # noqa: E501
|
||||
|
||||
# input measures:
|
||||
@@ -285,7 +284,7 @@ class Infos:
|
||||
|
||||
# controller:
|
||||
Register.SIGNAL_STRENGTH: {'name': ['controller', 'Signal_Strength'], 'level': logging.DEBUG, 'unit': '%', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'signal_', 'fmt': '| int', 'name': 'Signal Strength', 'icon': 'mdi:wifi'}}, # noqa: E501
|
||||
Register.POWER_ON_TIME: {'name': ['controller', 'Power_On_Time'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': 'duration', 'stat_cla': 'measurement', 'id': 'power_on_time_', 'fmt': '| float', 'name': 'Power on Time', 'nat_prc': '3', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.POWER_ON_TIME: {'name': ['controller', 'Power_On_Time'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': 'duration', 'stat_cla': 'measurement', 'id': 'power_on_time_', 'fmt': '| int', 'name': 'Power on Time', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.COLLECT_INTERVAL: {'name': ['controller', 'Collect_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_collect_intval_', 'fmt': '| string + " s"', 'name': 'Data Collect Interval', 'icon': 'mdi:update', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.CONNECT_COUNT: {'name': ['controller', 'Connect_Count'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'connect_count_', 'fmt': '| int', 'name': 'Connect Count', 'icon': 'mdi:counter', 'comp': 'sensor', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.COMMUNICATION_TYPE: {'name': ['controller', 'Communication_Type'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'comm_type_', 'name': 'Communication Type', 'val_tpl': __comm_type_val_tpl, 'comp': 'sensor', 'icon': 'mdi:wifi'}}, # noqa: E501
|
||||
|
||||
Reference in New Issue