# configuration to reach tsun cloud
|
||||
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
||||
tsun.host = 'logger.talent-monitoring.com'
|
||||
tsun.port = 5005
|
||||
##########################################################################################
|
||||
###
|
||||
### T S U N - G E N 3 - P R O X Y
|
||||
###
|
||||
### from Stefan Allius
|
||||
###
|
||||
##########################################################################################
|
||||
###
|
||||
### The readme will give you an overview of the project:
|
||||
### https://s-allius.github.io/tsun-gen3-proxy/
|
||||
###
|
||||
### The proxy supports different operation modes. Select the proper mode
|
||||
### which depends on your inverter type and you inverter firmware.
|
||||
### Please read:
|
||||
### https://github.com/s-allius/tsun-gen3-proxy/wiki/Operation-Modes-Overview
|
||||
###
|
||||
### Here you will find a description of all configuration options:
|
||||
### https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-details
|
||||
###
|
||||
### The configration uses the TOML format, which aims to be easy to read due to
|
||||
### obvious semantics. You find more details here: https://toml.io/en/v1.0.0
|
||||
###
|
||||
##########################################################################################
|
||||
|
||||
# configuration to reach the new tsun cloud for G3 Plus inverters
|
||||
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
||||
solarman.host = 'iot.talent-monitoring.com'
|
||||
solarman.port = 10000
|
||||
|
||||
# mqtt broker configuration
|
||||
##########################################################################################
|
||||
##
|
||||
## MQTT broker configuration
|
||||
##
|
||||
## In this block, you must configure the connection to your MQTT broker and specify the
|
||||
## required credentials. As the proxy does not currently support an encrypted connection
|
||||
## to the MQTT broker, it is strongly recommended that you do not use a public broker.
|
||||
##
|
||||
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-details#mqtt-broker-account
|
||||
##
|
||||
|
||||
mqtt.host = 'mqtt' # URL or IP address of the mqtt broker
|
||||
mqtt.port = 1883
|
||||
mqtt.user = ''
|
||||
mqtt.passwd = ''
|
||||
|
||||
|
||||
# home-assistant
|
||||
##########################################################################################
|
||||
##
|
||||
## HOME ASSISTANT
|
||||
##
|
||||
## The proxy supports the MQTT autoconfiguration of Home Assistant (HA). The default
|
||||
## values match the HA default configuration. If you need to change these or want to use
|
||||
## a different MQTT client, you can adjust the prefixes of the MQTT topics below.
|
||||
##
|
||||
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-details#home-assistant
|
||||
##
|
||||
|
||||
ha.auto_conf_prefix = 'homeassistant' # MQTT prefix for subscribing for homeassistant status updates
|
||||
ha.discovery_prefix = 'homeassistant' # MQTT prefix for discovery topic
|
||||
ha.entity_prefix = 'tsun' # MQTT topic prefix for publishing inverter values
|
||||
ha.proxy_node_id = 'proxy' # MQTT node id, for the proxy_node_id
|
||||
ha.proxy_unique_id = 'P170000000000001' # MQTT unique id, to identify a proxy instance
|
||||
|
||||
# microinverters
|
||||
inverters.allow_all = true # allow inverters, even if we have no inverter mapping
|
||||
|
||||
# inverter mapping, maps a `serial_no* to a `mqtt_id` and defines an optional `suggested_place` for `home-assistant`
|
||||
#
|
||||
# for each inverter add a block starting with [inverters."<16-digit serial numbeer>"]
|
||||
##########################################################################################
|
||||
##
|
||||
## GEN3 Proxy Mode Configuration
|
||||
##
|
||||
## In this block, you can configure an optional connection to the TSUN cloud for GEN3
|
||||
## inverters. This connection is only required if you want send data to the TSUN cloud
|
||||
## to use the TSUN APPs or receive firmware updates.
|
||||
##
|
||||
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-details#tsun-cloud-for-gen3-inverter-only
|
||||
##
|
||||
|
||||
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
||||
tsun.host = 'logger.talent-monitoring.com'
|
||||
tsun.port = 5005
|
||||
|
||||
|
||||
##########################################################################################
|
||||
##
|
||||
## GEN3PLUS Proxy Mode Configuration
|
||||
##
|
||||
## In this block, you can configure an optional connection to the TSUN cloud for GEN3PLUS
|
||||
## inverters. This connection is only required if you want send data to the TSUN cloud
|
||||
## to use the TSUN APPs or receive firmware updates.
|
||||
##
|
||||
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-details#solarman-cloud-for-gen3plus-inverter-only
|
||||
##
|
||||
|
||||
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
||||
solarman.host = 'iot.talent-monitoring.com'
|
||||
solarman.port = 10000
|
||||
|
||||
|
||||
##########################################################################################
|
||||
###
|
||||
### Inverter Definitions
|
||||
###
|
||||
### The proxy supports the simultaneous operation of several inverters, even of different
|
||||
### types. A configuration block must be defined for each inverter, in which all necessary
|
||||
### parameters must be specified. These depend on the operation mode used and also differ
|
||||
### slightly depending on the inverter type.
|
||||
###
|
||||
### In addition, the PV modules can be defined at the individual inputs for documentation
|
||||
### purposes, whereby these are displayed in Home Assistant.
|
||||
###
|
||||
### The proxy only accepts connections from known inverters. This can be switched off for
|
||||
### test purposes and unknown serial numbers are also accepted.
|
||||
###
|
||||
|
||||
inverters.allow_all = false # only allow known inverters
|
||||
|
||||
|
||||
##########################################################################################
|
||||
##
|
||||
## For each GEN3 inverter, the serial number of the inverter must be mapped to an MQTT
|
||||
## definition. To do this, the corresponding configuration block is started with
|
||||
## `[Inverter.“<16-digit serial number>”]` so that all subsequent parameters are assigned
|
||||
## to this inverter. Further inverter-specific parameters (e.g. polling mode) can be set
|
||||
## in the configuration block
|
||||
##
|
||||
## The serial numbers of all GEN3 inverters start with `R17`!
|
||||
##
|
||||
|
||||
[inverters."R170000000000001"]
|
||||
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
||||
#suggested_area = '' # Optional, suggested installation area for home-assistant
|
||||
modbus_polling = false # Disable optional MODBUS polling
|
||||
#pv1 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv2 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
# end of block [inverters."R170000000000001"]
|
||||
node_id = '' # MQTT replacement for inverters serial number
|
||||
suggested_area = '' # suggested installation area for home-assistant
|
||||
modbus_polling = false # Disable optional MODBUS polling
|
||||
pv1 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
pv2 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
|
||||
#[inverters."R17xxxxxxxxxxxx2"]
|
||||
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
||||
#suggested_area = '' # Optional, suggested installation area for home-assistant
|
||||
#modbus_polling = false # Disable optional MODBUS polling
|
||||
#pv1 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv2 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
# end of block [inverters."R170000000000002"]
|
||||
|
||||
##########################################################################################
|
||||
##
|
||||
## For each GEN3PLUS inverter, the serial number of the inverter must be mapped to an MQTT
|
||||
## definition. To do this, the corresponding configuration block is started with
|
||||
## `[Inverter.“<16-digit serial number>”]` so that all subsequent parameters are assigned
|
||||
## to this inverter. Further inverter-specific parameters (e.g. polling mode, client mode)
|
||||
## can be set in the configuration block
|
||||
##
|
||||
## The serial numbers of all GEN3PLUS inverters start with `Y17` or Y47! Each GEN3PLUS
|
||||
## inverter is supplied with a “Monitoring SN:”. This can be found on a sticker enclosed
|
||||
## with the inverter.
|
||||
##
|
||||
|
||||
[inverters."Y170000000000001"]
|
||||
monitor_sn = 2000000000 # The "Monitoring SN:" can be found on a sticker enclosed with the inverter
|
||||
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
||||
#suggested_area = '' # Optional, suggested installation place for home-assistant
|
||||
modbus_polling = true # Enable optional MODBUS polling
|
||||
monitor_sn = 2000000000 # The GEN3PLUS "Monitoring SN:"
|
||||
node_id = '' # MQTT replacement for inverters serial number
|
||||
suggested_area = '' # suggested installation place for home-assistant
|
||||
modbus_polling = true # Enable optional MODBUS polling
|
||||
|
||||
# if your inverter supports SSL connections you must use the client_mode. Pls, uncomment
|
||||
# the next line and configure the fixed IP of your inverter
|
||||
#client_mode = {host = '192.168.0.1', port = 8899}
|
||||
|
||||
#pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv4 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
# end of block [inverters."Y170000000000001"]
|
||||
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
pv4 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
|
||||
##########################################################################################
|
||||
###
|
||||
### If the proxy mode is configured, commands from TSUN can be sent to the inverter via
|
||||
### this connection or parameters (e.g. network credentials) can be queried. Filters can
|
||||
### then be configured for the AT+ commands from the TSUN Cloud so that only certain
|
||||
### accesses are permitted.
|
||||
###
|
||||
### An overview of all known AT+ commands can be found here:
|
||||
### https://github.com/s-allius/tsun-gen3-proxy/wiki/AT--commands
|
||||
###
|
||||
|
||||
[gen3plus.at_acl]
|
||||
# filter for received commands from the internet
|
||||
tsun.allow = ['AT+Z', 'AT+UPURL', 'AT+SUPDATE']
|
||||
tsun.block = []
|
||||
# filter for received commands from the MQTT broker
|
||||
mqtt.allow = ['AT+']
|
||||
mqtt.block = []
|
||||
# end of block [gen3plus.at_acl]
|
||||
|
||||