Fix in Power.md

This commit is contained in:
Kryštof Černý
2022-04-19 13:01:40 +02:00
committed by GitHub
parent d808345b5b
commit c68cedf8cf

View File

@@ -13,7 +13,7 @@ Combining these two gives the common equation, power is `Volts (V) squared / Res
The resistance of the tip is fixed, ~7.5 ohms for the TS100/Pinecil and ~4.5 ohms for the TS80(P).
This means that for both irons, the power delivered to the soldering tip is proportional to the voltage used, squared.
This is why the TS100 performs poorly when run off 12 V power supplies.
Therefore the TS100 performs poorly when run off 12 V power supplies.
## Output Control & Regulation