@@ -130,7 +130,13 @@ Flash temperature reading at idle if tip is hot
|
||||
Note:
|
||||
If the difference between the target temperature and the measured temperature is less than 5°C, **calibration is NOT required at all**.
|
||||
|
||||
This is used to calibrate the offset between ADC and Op-amp of the tip at next boot (Idealy it has to be done at boot, before internal components get warm.). But this setting is ***not permanent!*** It resetes after the calibration is completed (At next boot the checkbox will be unchecked!). If you need to repeat the calibration however, you have to set the checkbox *again*, unplug your device and let it cool down to room/ambient temperature & power it up, idealy while it sits on the desk.
|
||||
This is used to calibrate the offset between ADC and Op-amp of the tip **at next boot** (Ideally it has to be done at boot, before internal components get warm.). If the checkbox is set, the calibration will only be performed at the next boot. After a successful calibration the checkbox will be unchecked again! If you need to repeat the calibration however, you have to set the checkbox *again*, unplug your device and let it cool down to room/ambient temperature & power it up, ideally while it sits on the desk.
|
||||
|
||||
Also, the calibration will only take place if both of the following conditions are met:
|
||||
- The tip must be installed.
|
||||
- The temperature difference between tip and handle must be less than 10°C.
|
||||
|
||||
Otherwise, the calibration will be performed the next time the device is started and both conditions are met, unless the corresponding checkbox is unchecked.
|
||||
|
||||
Hence, never repeat the calibration in quick succession!
|
||||
|
||||
|
||||