Use the ADC_MAX_READING value

This commit is contained in:
Ben V. Brown
2025-01-11 12:56:00 +11:00
parent be1536b82f
commit 53982efa14

View File

@@ -249,7 +249,7 @@ void detectThermalRunaway(const TemperatureType_t currentTipTempInC, const uint3
static bool haveSeenDelta = false;
// Check for readings being pegged at the top of the ADC while the heater is off
if (!thisCycleIsHeating && (getTipRawTemp(0) > (0x7FFF - 16))) {
if (!thisCycleIsHeating && (getTipRawTemp(0) > (ADC_MAX_READING - 8))) {
heaterThermalRunaway = true;
}