mirror of
https://github.com/Ralim/IronOS.git
synced 2025-02-26 07:53:55 +00:00
Use the ADC_MAX_READING value
This commit is contained in:
@@ -249,7 +249,7 @@ void detectThermalRunaway(const TemperatureType_t currentTipTempInC, const uint3
|
||||
static bool haveSeenDelta = false;
|
||||
|
||||
// Check for readings being pegged at the top of the ADC while the heater is off
|
||||
if (!thisCycleIsHeating && (getTipRawTemp(0) > (0x7FFF - 16))) {
|
||||
if (!thisCycleIsHeating && (getTipRawTemp(0) > (ADC_MAX_READING - 8))) {
|
||||
heaterThermalRunaway = true;
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue