import logging
|
|
import json
|
|
import os
|
|
from enum import Enum
|
|
from typing import Generator
|
|
|
|
|
|
class Register(Enum):
|
|
COLLECTOR_FW_VERSION = 1
|
|
CHIP_TYPE = 2
|
|
CHIP_MODEL = 3
|
|
TRACE_URL = 4
|
|
LOGGER_URL = 5
|
|
PRODUCT_NAME = 20
|
|
MANUFACTURER = 21
|
|
VERSION = 22
|
|
SERIAL_NUMBER = 23
|
|
EQUIPMENT_MODEL = 24
|
|
NO_INPUTS = 25
|
|
MAX_DESIGNED_POWER = 26
|
|
INVERTER_CNT = 50
|
|
UNKNOWN_SNR = 51
|
|
UNKNOWN_MSG = 52
|
|
INVALID_DATA_TYPE = 53
|
|
INTERNAL_ERROR = 54
|
|
UNKNOWN_CTRL = 55
|
|
OTA_START_MSG = 56
|
|
SW_EXCEPTION = 57
|
|
INVALID_MSG_FMT = 58
|
|
AT_COMMAND = 59
|
|
OUTPUT_POWER = 83
|
|
RATED_POWER = 84
|
|
INVERTER_TEMP = 85
|
|
INVERTER_STATUS = 86
|
|
PV1_VOLTAGE = 100
|
|
PV1_CURRENT = 101
|
|
PV1_POWER = 102
|
|
PV1_MANUFACTURER = 103
|
|
PV1_MODEL = 104
|
|
PV2_VOLTAGE = 110
|
|
PV2_CURRENT = 111
|
|
PV2_POWER = 112
|
|
PV2_MANUFACTURER = 113
|
|
PV2_MODEL = 114
|
|
PV3_VOLTAGE = 120
|
|
PV3_CURRENT = 121
|
|
PV3_POWER = 122
|
|
PV3_MANUFACTURER = 123
|
|
PV3_MODEL = 124
|
|
PV4_VOLTAGE = 130
|
|
PV4_CURRENT = 131
|
|
PV4_POWER = 132
|
|
PV4_MANUFACTURER = 133
|
|
PV4_MODEL = 134
|
|
PV5_VOLTAGE = 140
|
|
PV5_CURRENT = 141
|
|
PV5_POWER = 142
|
|
PV5_MANUFACTURER = 143
|
|
PV5_MODEL = 144
|
|
PV6_VOLTAGE = 150
|
|
PV6_CURRENT = 151
|
|
PV6_POWER = 152
|
|
PV6_MANUFACTURER = 153
|
|
PV6_MODEL = 154
|
|
PV1_DAILY_GENERATION = 200
|
|
PV1_TOTAL_GENERATION = 201
|
|
PV2_DAILY_GENERATION = 210
|
|
PV2_TOTAL_GENERATION = 211
|
|
PV3_DAILY_GENERATION = 220
|
|
PV3_TOTAL_GENERATION = 221
|
|
PV4_DAILY_GENERATION = 230
|
|
PV4_TOTAL_GENERATION = 231
|
|
PV5_DAILY_GENERATION = 240
|
|
PV5_TOTAL_GENERATION = 241
|
|
PV6_DAILY_GENERATION = 250
|
|
PV6_TOTAL_GENERATION = 251
|
|
GRID_VOLTAGE = 300
|
|
GRID_CURRENT = 301
|
|
GRID_FREQUENCY = 302
|
|
DAILY_GENERATION = 303
|
|
TOTAL_GENERATION = 304
|
|
COMMUNICATION_TYPE = 400
|
|
SIGNAL_STRENGTH = 401
|
|
POWER_ON_TIME = 402
|
|
COLLECT_INTERVAL = 403
|
|
DATA_UP_INTERVAL = 404
|
|
CONNECT_COUNT = 405
|
|
HEARTBEAT_INTERVAL = 406
|
|
IP_ADRESS = 407
|
|
EVENT_401 = 500
|
|
EVENT_402 = 501
|
|
EVENT_403 = 502
|
|
EVENT_404 = 503
|
|
EVENT_405 = 504
|
|
EVENT_406 = 505
|
|
EVENT_407 = 506
|
|
EVENT_408 = 507
|
|
EVENT_409 = 508
|
|
EVENT_410 = 509
|
|
EVENT_411 = 510
|
|
EVENT_412 = 511
|
|
EVENT_413 = 512
|
|
EVENT_414 = 513
|
|
EVENT_415 = 514
|
|
EVENT_416 = 515
|
|
VALUE_1 = 9000
|
|
TEST_REG1 = 10000
|
|
TEST_REG2 = 10001
|
|
|
|
|
|
class ClrAtMidnight:
|
|
__clr_at_midnight = [Register.PV1_DAILY_GENERATION, Register.PV2_DAILY_GENERATION, Register.PV3_DAILY_GENERATION, Register.PV4_DAILY_GENERATION, Register.PV5_DAILY_GENERATION, Register.PV6_DAILY_GENERATION, Register.DAILY_GENERATION] # noqa: E501
|
|
db = {}
|
|
|
|
@classmethod
|
|
def add(cls, keys: list, prfx: str, reg: Register) -> None:
|
|
if reg not in cls.__clr_at_midnight:
|
|
return
|
|
|
|
prfx += f'{keys[0]}'
|
|
dict = cls.db
|
|
if prfx not in dict:
|
|
dict[prfx] = {}
|
|
dict = dict[prfx]
|
|
|
|
for key in keys[1:-1]:
|
|
if key not in dict:
|
|
dict[key] = {}
|
|
dict = dict[key]
|
|
dict[keys[-1]] = 0
|
|
|
|
@classmethod
|
|
def elm(cls) -> Generator[tuple[str, dict], None, None]:
|
|
for reg, name in cls.db.items():
|
|
yield reg, name
|
|
cls.db = {}
|
|
|
|
|
|
class Infos:
|
|
stat = {}
|
|
app_name = os.getenv('SERVICE_NAME', 'proxy')
|
|
version = os.getenv('VERSION', 'unknown')
|
|
|
|
new_stat_data = {}
|
|
|
|
@classmethod
|
|
def static_init(cls):
|
|
logging.info('Initialize proxy statistics')
|
|
# init proxy counter in the class.stat dictionary
|
|
cls.stat['proxy'] = {}
|
|
for key in cls.__info_defs:
|
|
name = cls.__info_defs[key]['name']
|
|
if name[0] == 'proxy':
|
|
cls.stat['proxy'][name[1]] = 0
|
|
|
|
# add values from the environment to the device definition table
|
|
prxy = cls.__info_devs['proxy']
|
|
prxy['sw'] = cls.version
|
|
prxy['mdl'] = cls.app_name
|
|
|
|
def __init__(self):
|
|
self.db = {}
|
|
self.tracer = logging.getLogger('data')
|
|
|
|
__info_devs = {
|
|
'proxy': {'singleton': True, 'name': 'Proxy', 'mf': 'Stefan Allius'}, # noqa: E501
|
|
'controller': {'via': 'proxy', 'name': 'Controller', 'mdl': Register.CHIP_MODEL, 'mf': Register.CHIP_TYPE, 'sw': Register.COLLECTOR_FW_VERSION}, # noqa: E501
|
|
'inverter': {'via': 'controller', 'name': 'Micro Inverter', 'mdl': Register.EQUIPMENT_MODEL, 'mf': Register.MANUFACTURER, 'sw': Register.VERSION}, # noqa: E501
|
|
'input_pv1': {'via': 'inverter', 'name': 'Module PV1', 'mdl': Register.PV1_MODEL, 'mf': Register.PV1_MANUFACTURER}, # noqa: E501
|
|
'input_pv2': {'via': 'inverter', 'name': 'Module PV2', 'mdl': Register.PV2_MODEL, 'mf': Register.PV2_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 2}}, # noqa: E501
|
|
'input_pv3': {'via': 'inverter', 'name': 'Module PV3', 'mdl': Register.PV3_MODEL, 'mf': Register.PV3_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 3}}, # noqa: E501
|
|
'input_pv4': {'via': 'inverter', 'name': 'Module PV4', 'mdl': Register.PV4_MODEL, 'mf': Register.PV4_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 4}}, # noqa: E501
|
|
'input_pv5': {'via': 'inverter', 'name': 'Module PV5', 'mdl': Register.PV5_MODEL, 'mf': Register.PV5_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 5}}, # noqa: E501
|
|
'input_pv6': {'via': 'inverter', 'name': 'Module PV6', 'mdl': Register.PV6_MODEL, 'mf': Register.PV6_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 6}}, # noqa: E501
|
|
}
|
|
|
|
__comm_type_val_tpl = "{%set com_types = ['n/a','Wi-Fi', 'G4', 'G5', 'GPRS'] %}{{com_types[value_json['Communication_Type']|int(0)]|default(value_json['Communication_Type'])}}" # noqa: E501
|
|
__status_type_val_tpl = "{%set inv_status = ['n/a', 'Online', 'Offline'] %}{{inv_status[value_json['Inverter_Status']|int(0)]|default(value_json['Inverter_Status'])}}" # noqa: E501
|
|
|
|
__info_defs = {
|
|
# collector values used for device registration:
|
|
Register.COLLECTOR_FW_VERSION: {'name': ['collector', 'Collector_Fw_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.CHIP_TYPE: {'name': ['collector', 'Chip_Type'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.CHIP_MODEL: {'name': ['collector', 'Chip_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.TRACE_URL: {'name': ['collector', 'Trace_URL'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.LOGGER_URL: {'name': ['collector', 'Logger_URL'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
# inverter values used for device registration:
|
|
Register.PRODUCT_NAME: {'name': ['inverter', 'Product_Name'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.MANUFACTURER: {'name': ['inverter', 'Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.VERSION: {'name': ['inverter', 'Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.SERIAL_NUMBER: {'name': ['inverter', 'Serial_Number'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EQUIPMENT_MODEL: {'name': ['inverter', 'Equipment_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.NO_INPUTS: {'name': ['inverter', 'No_Inputs'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.MAX_DESIGNED_POWER: {'name': ['inverter', 'Max_Designed_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'designed_power_', 'fmt': '| string + " W"', 'name': 'Max Designed Power', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.RATED_POWER: {'name': ['inverter', 'Rated_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'rated_power_', 'fmt': '| string + " W"', 'name': 'Rated Power', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
|
|
Register.PV1_MANUFACTURER: {'name': ['inverter', 'PV1_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV1_MODEL: {'name': ['inverter', 'PV1_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV2_MANUFACTURER: {'name': ['inverter', 'PV2_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV2_MODEL: {'name': ['inverter', 'PV2_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV3_MANUFACTURER: {'name': ['inverter', 'PV3_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV3_MODEL: {'name': ['inverter', 'PV3_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV4_MANUFACTURER: {'name': ['inverter', 'PV4_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV4_MODEL: {'name': ['inverter', 'PV4_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV5_MANUFACTURER: {'name': ['inverter', 'PV5_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV5_MODEL: {'name': ['inverter', 'PV5_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV6_MANUFACTURER: {'name': ['inverter', 'PV6_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV6_MODEL: {'name': ['inverter', 'PV6_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
# proxy:
|
|
Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': '| int', 'name': 'Active Inverter Connections', 'icon': 'mdi:counter'}}, # noqa: E501
|
|
Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': '| int', 'name': 'Unknown Serial No', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.UNKNOWN_MSG: {'name': ['proxy', 'Unknown_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_msg_', 'fmt': '| int', 'name': 'Unknown Msg Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INVALID_DATA_TYPE: {'name': ['proxy', 'Invalid_Data_Type'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_data_type_', 'fmt': '| int', 'name': 'Invalid Data Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INTERNAL_ERROR: {'name': ['proxy', 'Internal_Error'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'intern_err_', 'fmt': '| int', 'name': 'Internal Error', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic', 'en': False}}, # noqa: E501
|
|
Register.UNKNOWN_CTRL: {'name': ['proxy', 'Unknown_Ctrl'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_ctrl_', 'fmt': '| int', 'name': 'Unknown Control Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.OTA_START_MSG: {'name': ['proxy', 'OTA_Start_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'ota_start_cmd_', 'fmt': '| int', 'name': 'OTA Start Cmd', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.SW_EXCEPTION: {'name': ['proxy', 'SW_Exception'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'sw_exception_', 'fmt': '| int', 'name': 'Internal SW Exception', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INVALID_MSG_FMT: {'name': ['proxy', 'Invalid_Msg_Format'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_msg_fmt_', 'fmt': '| int', 'name': 'Invalid Message Format', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.AT_COMMAND: {'name': ['proxy', 'AT_Command'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'at_cmd_', 'fmt': '| int', 'name': 'AT Command', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':'| float','name': 'Grid Voltage'}}, # noqa: E501
|
|
|
|
# events
|
|
Register.EVENT_401: {'name': ['events', '401_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_402: {'name': ['events', '402_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_403: {'name': ['events', '403_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_404: {'name': ['events', '404_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_405: {'name': ['events', '405_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_406: {'name': ['events', '406_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_407: {'name': ['events', '407_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_408: {'name': ['events', '408_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_409: {'name': ['events', '409_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_410: {'name': ['events', '410_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_411: {'name': ['events', '411_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_412: {'name': ['events', '412_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_413: {'name': ['events', '413_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_414: {'name': ['events', '414_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_415: {'name': ['events', '415_GridFreqOverRating'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_416: {'name': ['events', '416_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
# grid measures:
|
|
Register.GRID_VOLTAGE: {'name': ['grid', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'inverter', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'fmt': '| float', 'name': 'Grid Voltage', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.GRID_CURRENT: {'name': ['grid', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'inverter', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'fmt': '| float', 'name': 'Grid Current', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.GRID_FREQUENCY: {'name': ['grid', 'Frequency'], 'level': logging.DEBUG, 'unit': 'Hz', 'ha': {'dev': 'inverter', 'dev_cla': 'frequency', 'stat_cla': 'measurement', 'id': 'out_freq_', 'fmt': '| float', 'name': 'Grid Frequency', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.OUTPUT_POWER: {'name': ['grid', 'Output_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'fmt': '| float', 'name': 'Power'}}, # noqa: E501
|
|
Register.INVERTER_TEMP: {'name': ['env', 'Inverter_Temp'], 'level': logging.DEBUG, 'unit': '°C', 'ha': {'dev': 'inverter', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_', 'fmt': '| int', 'name': 'Temperature'}}, # noqa: E501
|
|
Register.VALUE_1: {'name': ['env', 'Value_1'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'value_1_', 'fmt': '| int', 'name': 'Value 1', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INVERTER_STATUS: {'name': ['env', 'Inverter_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_status_', 'name': 'Inverter Status', 'val_tpl': __status_type_val_tpl, 'icon': 'mdi:counter'}}, # noqa: E501
|
|
|
|
# input measures:
|
|
Register.PV1_VOLTAGE: {'name': ['input', 'pv1', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV1_CURRENT: {'name': ['input', 'pv1', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV1_POWER: {'name': ['input', 'pv1', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'input_pv1', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv1_', 'val_tpl': "{{ (value_json['pv1']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV2_VOLTAGE: {'name': ['input', 'pv2', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV2_CURRENT: {'name': ['input', 'pv2', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV2_POWER: {'name': ['input', 'pv2', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'input_pv2', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv2_', 'val_tpl': "{{ (value_json['pv2']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV3_VOLTAGE: {'name': ['input', 'pv3', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv3', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv3_', 'val_tpl': "{{ (value_json['pv3']['Voltage'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV3_CURRENT: {'name': ['input', 'pv3', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv3', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv3_', 'val_tpl': "{{ (value_json['pv3']['Current'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV3_POWER: {'name': ['input', 'pv3', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'input_pv3', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv3_', 'val_tpl': "{{ (value_json['pv3']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV4_VOLTAGE: {'name': ['input', 'pv4', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv4', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv4_', 'val_tpl': "{{ (value_json['pv4']['Voltage'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV4_CURRENT: {'name': ['input', 'pv4', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv4', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv4_', 'val_tpl': "{{ (value_json['pv4']['Current'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV4_POWER: {'name': ['input', 'pv4', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'input_pv4', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv4_', 'val_tpl': "{{ (value_json['pv4']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV5_VOLTAGE: {'name': ['input', 'pv5', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv5', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv5_', 'val_tpl': "{{ (value_json['pv5']['Voltage'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV5_CURRENT: {'name': ['input', 'pv5', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv5', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv5_', 'val_tpl': "{{ (value_json['pv5']['Current'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV5_POWER: {'name': ['input', 'pv5', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'input_pv5', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv5_', 'val_tpl': "{{ (value_json['pv5']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV6_VOLTAGE: {'name': ['input', 'pv6', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv6', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv6_', 'val_tpl': "{{ (value_json['pv6']['Voltage'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV6_CURRENT: {'name': ['input', 'pv6', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv6', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv6_', 'val_tpl': "{{ (value_json['pv6']['Current'] | float)}}", 'icon': 'mdi:gauge', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV6_POWER: {'name': ['input', 'pv6', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'input_pv6', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv6_', 'val_tpl': "{{ (value_json['pv6']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV1_DAILY_GENERATION: {'name': ['input', 'pv1', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv1', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv1_', 'name': 'Daily Generation', 'val_tpl': "{{ (value_json['pv1']['Daily_Generation'] | float)}}", 'icon': 'mdi:solar-power-variant', 'must_incr': True}}, # noqa: E501
|
|
Register.PV1_TOTAL_GENERATION: {'name': ['input', 'pv1', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv1', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv1_', 'name': 'Total Generation', 'val_tpl': "{{ (value_json['pv1']['Total_Generation'] | float)}}", 'icon': 'mdi:solar-power', 'must_incr': True}}, # noqa: E501
|
|
Register.PV2_DAILY_GENERATION: {'name': ['input', 'pv2', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv2', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv2_', 'name': 'Daily Generation', 'val_tpl': "{{ (value_json['pv2']['Daily_Generation'] | float)}}", 'icon': 'mdi:solar-power-variant', 'must_incr': True}}, # noqa: E501
|
|
Register.PV2_TOTAL_GENERATION: {'name': ['input', 'pv2', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv2', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv2_', 'name': 'Total Generation', 'val_tpl': "{{ (value_json['pv2']['Total_Generation'] | float)}}", 'icon': 'mdi:solar-power', 'must_incr': True}}, # noqa: E501
|
|
Register.PV3_DAILY_GENERATION: {'name': ['input', 'pv3', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv3', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv3_', 'name': 'Daily Generation', 'val_tpl': "{{ (value_json['pv3']['Daily_Generation'] | float)}}", 'icon': 'mdi:solar-power-variant', 'must_incr': True}}, # noqa: E501
|
|
Register.PV3_TOTAL_GENERATION: {'name': ['input', 'pv3', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv3', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv3_', 'name': 'Total Generation', 'val_tpl': "{{ (value_json['pv3']['Total_Generation'] | float)}}", 'icon': 'mdi:solar-power', 'must_incr': True}}, # noqa: E501
|
|
Register.PV4_DAILY_GENERATION: {'name': ['input', 'pv4', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv4', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv4_', 'name': 'Daily Generation', 'val_tpl': "{{ (value_json['pv4']['Daily_Generation'] | float)}}", 'icon': 'mdi:solar-power-variant', 'must_incr': True}}, # noqa: E501
|
|
Register.PV4_TOTAL_GENERATION: {'name': ['input', 'pv4', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv4', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv4_', 'name': 'Total Generation', 'val_tpl': "{{ (value_json['pv4']['Total_Generation'] | float)}}", 'icon': 'mdi:solar-power', 'must_incr': True}}, # noqa: E501
|
|
Register.PV5_DAILY_GENERATION: {'name': ['input', 'pv5', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv5', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv5_', 'name': 'Daily Generation', 'val_tpl': "{{ (value_json['pv5']['Daily_Generation'] | float)}}", 'icon': 'mdi:solar-power-variant', 'must_incr': True}}, # noqa: E501
|
|
Register.PV5_TOTAL_GENERATION: {'name': ['input', 'pv5', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv5', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv5_', 'name': 'Total Generation', 'val_tpl': "{{ (value_json['pv5']['Total_Generation'] | float)}}", 'icon': 'mdi:solar-power', 'must_incr': True}}, # noqa: E501
|
|
Register.PV6_DAILY_GENERATION: {'name': ['input', 'pv6', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv6', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv6_', 'name': 'Daily Generation', 'val_tpl': "{{ (value_json['pv6']['Daily_Generation'] | float)}}", 'icon': 'mdi:solar-power-variant', 'must_incr': True}}, # noqa: E501
|
|
Register.PV6_TOTAL_GENERATION: {'name': ['input', 'pv6', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv6', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv6_', 'name': 'Total Generation', 'val_tpl': "{{ (value_json['pv6']['Total_Generation'] | float)}}", 'icon': 'mdi:solar-power', 'must_incr': True}}, # noqa: E501
|
|
# total:
|
|
Register.DAILY_GENERATION: {'name': ['total', 'Daily_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'inverter', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_', 'fmt': '| float', 'name': 'Daily Generation', 'icon': 'mdi:solar-power-variant', 'must_incr': True}}, # noqa: E501
|
|
Register.TOTAL_GENERATION: {'name': ['total', 'Total_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'inverter', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_', 'fmt': '| float', 'name': 'Total Generation', 'icon': 'mdi:solar-power', 'must_incr': True}}, # noqa: E501
|
|
|
|
# controller:
|
|
Register.SIGNAL_STRENGTH: {'name': ['controller', 'Signal_Strength'], 'level': logging.DEBUG, 'unit': '%', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'signal_', 'fmt': '| int', 'name': 'Signal Strength', 'icon': 'mdi:wifi'}}, # noqa: E501
|
|
Register.POWER_ON_TIME: {'name': ['controller', 'Power_On_Time'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': 'duration', 'stat_cla': 'measurement', 'id': 'power_on_time_', 'fmt': '| float', 'name': 'Power on Time', 'nat_prc': '3', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.COLLECT_INTERVAL: {'name': ['controller', 'Collect_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_collect_intval_', 'fmt': '| string + " s"', 'name': 'Data Collect Interval', 'icon': 'mdi:update', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.CONNECT_COUNT: {'name': ['controller', 'Connect_Count'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'connect_count_', 'fmt': '| int', 'name': 'Connect Count', 'icon': 'mdi:counter', 'comp': 'sensor', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.COMMUNICATION_TYPE: {'name': ['controller', 'Communication_Type'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'comm_type_', 'name': 'Communication Type', 'val_tpl': __comm_type_val_tpl, 'comp': 'sensor', 'icon': 'mdi:wifi'}}, # noqa: E501
|
|
Register.DATA_UP_INTERVAL: {'name': ['controller', 'Data_Up_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_up_intval_', 'fmt': '| string + " s"', 'name': 'Data Up Interval', 'icon': 'mdi:update', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.HEARTBEAT_INTERVAL: {'name': ['controller', 'Heartbeat_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'heartbeat_intval_', 'fmt': '| string + " s"', 'name': 'Heartbeat Interval', 'icon': 'mdi:update', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.IP_ADRESS: {'name': ['controller', 'IP_Adress'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'ip_adress_', 'fmt': '| string', 'name': 'IP Adress', 'icon': 'mdi:wifi', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
}
|
|
|
|
@property
|
|
def info_devs(self) -> dict:
|
|
return self.__info_devs
|
|
|
|
@property
|
|
def info_defs(self) -> dict:
|
|
return self.__info_defs
|
|
|
|
def dev_value(self, idx: str | int) -> str | int | float | None:
|
|
'''returns the stored device value from our database
|
|
|
|
idx:int ==> lookup the value in the database and return it as str,
|
|
int or float. If the value is not available return 'None'
|
|
idx:str ==> returns the string as a fixed value without a
|
|
database lookup
|
|
'''
|
|
if type(idx) is str:
|
|
return idx # return idx as a fixed value
|
|
elif idx in self.info_defs:
|
|
row = self.info_defs[idx]
|
|
if 'singleton' in row and row['singleton']:
|
|
dict = self.stat
|
|
else:
|
|
dict = self.db
|
|
|
|
keys = row['name']
|
|
|
|
for key in keys:
|
|
if key not in dict:
|
|
return None # value not found in the database
|
|
dict = dict[key]
|
|
return dict # value of the reqeusted entry
|
|
|
|
return None # unknwon idx, not in info_defs
|
|
|
|
def inc_counter(self, counter: str) -> None:
|
|
'''inc proxy statistic counter'''
|
|
dict = self.stat['proxy']
|
|
dict[counter] += 1
|
|
|
|
def dec_counter(self, counter: str) -> None:
|
|
'''dec proxy statistic counter'''
|
|
dict = self.stat['proxy']
|
|
dict[counter] -= 1
|
|
|
|
def ha_proxy_confs(self, ha_prfx: str, node_id: str, snr: str) \
|
|
-> Generator[tuple[dict, str], None, None]:
|
|
'''Generator function yields json register struct for home-assistant
|
|
auto configuration and the unique entity string, for all proxy
|
|
registers
|
|
|
|
arguments:
|
|
ha_prfx:str ==> MQTT prefix for the home assistant 'stat_t string
|
|
node_id:str ==> node id of the inverter, used to build unique entity
|
|
snr:str ==> serial number of the inverter, used to build unique
|
|
entity strings
|
|
'''
|
|
# iterate over RegisterMap.map and get the register values for entries
|
|
# with Singleton=True, which means that this is a proxy register
|
|
for reg in self.info_defs.keys():
|
|
res = self.ha_conf(reg, ha_prfx, node_id, snr, True) # noqa: E501
|
|
if res:
|
|
yield res
|
|
|
|
def ha_conf(self, key, ha_prfx, node_id, snr, singleton: bool,
|
|
sug_area: str = '') -> tuple[str, str, str, str] | None:
|
|
if key not in self.info_defs:
|
|
return None
|
|
row = self.info_defs[key]
|
|
|
|
if 'singleton' in row:
|
|
if singleton != row['singleton']:
|
|
return None
|
|
elif singleton:
|
|
return None
|
|
prfx = ha_prfx + node_id
|
|
|
|
# check if we have details for home assistant
|
|
if 'ha' in row:
|
|
ha = row['ha']
|
|
if 'comp' in ha:
|
|
component = ha['comp']
|
|
else:
|
|
component = 'sensor'
|
|
attr = {}
|
|
if 'name' in ha:
|
|
attr['name'] = ha['name']
|
|
else:
|
|
attr['name'] = row['name'][-1]
|
|
attr['stat_t'] = prfx + row['name'][0]
|
|
attr['dev_cla'] = ha['dev_cla']
|
|
attr['stat_cla'] = ha['stat_cla']
|
|
attr['uniq_id'] = ha['id']+snr
|
|
if 'val_tpl' in ha:
|
|
attr['val_tpl'] = ha['val_tpl']
|
|
elif 'fmt' in ha:
|
|
attr['val_tpl'] = '{{value_json' + f"['{row['name'][-1]}'] {ha['fmt']}" + '}}' # eg. 'val_tpl': "{{ value_json['Output_Power']|float }} # noqa: E501
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.info_defs: the row for {key} do"
|
|
" not have a 'val_tpl' nor a 'fmt' value")
|
|
# add unit_of_meas only, if status_class isn't none. If
|
|
# status_cla is None we want a number format and not line
|
|
# graph in home assistant. A unit will change the number
|
|
# format to a line graph
|
|
if 'unit' in row and attr['stat_cla'] is not None:
|
|
attr['unit_of_meas'] = row['unit'] # 'unit_of_meas'
|
|
if 'icon' in ha:
|
|
attr['ic'] = ha['icon'] # icon for the entity
|
|
if 'nat_prc' in ha:
|
|
attr['sug_dsp_prc'] = ha['nat_prc'] # precison of floats
|
|
if 'ent_cat' in ha:
|
|
attr['ent_cat'] = ha['ent_cat'] # diagnostic, config
|
|
# enabled_by_default is deactivated, since it avoid the via
|
|
# setup of the devices. It seems, that there is a bug in home
|
|
# assistant. tested with 'Home Assistant 2023.10.4'
|
|
# if 'en' in ha: # enabled_by_default
|
|
# attr['en'] = ha['en']
|
|
if 'dev' in ha:
|
|
device = self.info_devs[ha['dev']]
|
|
if 'dep' in device and self.ignore_this_device(device['dep']): # noqa: E501
|
|
return None
|
|
dev = {}
|
|
# the same name for 'name' and 'suggested area', so we get
|
|
# dedicated devices in home assistant with short value
|
|
# name and headline
|
|
if (sug_area == '' or
|
|
('singleton' in device and device['singleton'])):
|
|
dev['name'] = device['name']
|
|
dev['sa'] = device['name']
|
|
else:
|
|
dev['name'] = device['name']+' - '+sug_area
|
|
dev['sa'] = device['name']+' - '+sug_area
|
|
if 'via' in device: # add the link to the parent device
|
|
via = device['via']
|
|
if via in self.info_devs:
|
|
via_dev = self.info_devs[via]
|
|
if 'singleton' in via_dev and via_dev['singleton']:
|
|
dev['via_device'] = via
|
|
else:
|
|
dev['via_device'] = f"{via}_{snr}"
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.info_defs: the row for "
|
|
f"{key} has an invalid via value: "
|
|
f"{via}")
|
|
for key in ('mdl', 'mf', 'sw', 'hw'): # add optional
|
|
# values fpr 'modell', 'manufacturer', 'sw version' and
|
|
# 'hw version'
|
|
if key in device:
|
|
data = self.dev_value(device[key])
|
|
if data is not None:
|
|
dev[key] = data
|
|
if 'singleton' in device and device['singleton']:
|
|
dev['ids'] = [f"{ha['dev']}"]
|
|
else:
|
|
dev['ids'] = [f"{ha['dev']}_{snr}"]
|
|
attr['dev'] = dev
|
|
origin = {}
|
|
origin['name'] = self.app_name
|
|
origin['sw'] = self.version
|
|
attr['o'] = origin
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.info_defs: the row for {key} "
|
|
"missing 'dev' value for ha register")
|
|
return json.dumps(attr), component, node_id, attr['uniq_id']
|
|
return None
|
|
|
|
def _key_obj(self, id: Register) -> list:
|
|
d = self.info_defs.get(id, {'name': None, 'level': logging.DEBUG,
|
|
'unit': ''})
|
|
if 'ha' in d and 'must_incr' in d['ha']:
|
|
must_incr = d['ha']['must_incr']
|
|
else:
|
|
must_incr = False
|
|
|
|
return d['name'], d['level'], d['unit'], must_incr
|
|
|
|
def update_db(self, keys: list, must_incr: bool, result):
|
|
name = ''
|
|
dict = self.db
|
|
for key in keys[:-1]:
|
|
if key not in dict:
|
|
dict[key] = {}
|
|
dict = dict[key]
|
|
name += key + '.'
|
|
if keys[-1] not in dict:
|
|
update = (not must_incr or result > 0)
|
|
else:
|
|
if must_incr:
|
|
update = dict[keys[-1]] < result
|
|
else:
|
|
update = dict[keys[-1]] != result
|
|
if update:
|
|
dict[keys[-1]] = result
|
|
name += keys[-1]
|
|
return name, update
|
|
|
|
def set_db_def_value(self, id: Register, value) -> None:
|
|
'''set default value'''
|
|
row = self.info_defs[id]
|
|
if isinstance(row, dict):
|
|
keys = row['name']
|
|
self.update_db(keys, False, value)
|
|
|
|
def reg_clr_at_midnight(self, prfx: str,
|
|
check_dependencies: bool = True) -> None:
|
|
'''register all registers for the 'ClrAtMidnight' class and
|
|
check if device of every register is available otherwise ignore
|
|
the register.
|
|
|
|
prfx:str ==> prefix for the home assistant 'stat_t string''
|
|
'''
|
|
for id, row in self.info_defs.items():
|
|
if check_dependencies and 'ha' in row:
|
|
ha = row['ha']
|
|
if 'dev' in ha:
|
|
device = self.info_devs[ha['dev']]
|
|
if 'dep' in device and self.ignore_this_device(device['dep']): # noqa: E501
|
|
continue
|
|
|
|
keys = row['name']
|
|
ClrAtMidnight.add(keys, prfx, id)
|
|
|
|
def get_db_value(self, id: Register, not_found_result: any = None):
|
|
'''get database value'''
|
|
row = self.info_defs[id]
|
|
if isinstance(row, dict):
|
|
keys = row['name']
|
|
elm = self.db
|
|
for key in keys:
|
|
if key not in elm:
|
|
return not_found_result
|
|
elm = elm[key]
|
|
return elm
|
|
return not_found_result
|
|
|
|
def ignore_this_device(self, dep: dict) -> bool:
|
|
'''Checks the equation in the dep(endency) dict
|
|
|
|
returns 'False' only if the equation is valid;
|
|
'True' in any other case'''
|
|
if 'reg' in dep:
|
|
value = self.dev_value(dep['reg'])
|
|
if not value:
|
|
return True
|
|
|
|
if 'gte' in dep:
|
|
return not value >= dep['gte']
|
|
elif 'less_eq' in dep:
|
|
return not value <= dep['less_eq']
|
|
return True
|
|
|
|
def set_pv_module_details(self, inv: dict) -> None:
|
|
map = {'pv1': {'manufacturer': Register.PV1_MANUFACTURER, 'model': Register.PV1_MODEL}, # noqa: E501
|
|
'pv2': {'manufacturer': Register.PV2_MANUFACTURER, 'model': Register.PV2_MODEL}, # noqa: E501
|
|
'pv3': {'manufacturer': Register.PV3_MANUFACTURER, 'model': Register.PV3_MODEL}, # noqa: E501
|
|
'pv4': {'manufacturer': Register.PV4_MANUFACTURER, 'model': Register.PV4_MODEL}, # noqa: E501
|
|
'pv5': {'manufacturer': Register.PV5_MANUFACTURER, 'model': Register.PV5_MODEL}, # noqa: E501
|
|
'pv6': {'manufacturer': Register.PV6_MANUFACTURER, 'model': Register.PV6_MODEL} # noqa: E501
|
|
}
|
|
|
|
for key, reg in map.items():
|
|
if key in inv:
|
|
if 'manufacturer' in inv[key]:
|
|
self.set_db_def_value(reg['manufacturer'],
|
|
inv[key]['manufacturer'])
|
|
if 'type' in inv[key]:
|
|
self.set_db_def_value(reg['model'], inv[key]['type'])
|