* add shutdown flag * add more register definitions * add start commando for client side connections * add first support for port 8899 * fix shutdown * add client_mode configuration * read client_mode config to setup inverter connections * add client_mode connections over port 8899 * add preview build
58 lines
2.9 KiB
TOML
58 lines
2.9 KiB
TOML
# configuration to reach tsun cloud
|
|
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
|
tsun.host = 'logger.talent-monitoring.com'
|
|
tsun.port = 5005
|
|
|
|
# configuration to reach the new tsun cloud for G3 Plus inverters
|
|
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
|
solarman.host = 'iot.talent-monitoring.com'
|
|
solarman.port = 10000
|
|
|
|
# mqtt broker configuration
|
|
mqtt.host = 'mqtt' # URL or IP address of the mqtt broker
|
|
mqtt.port = 1883
|
|
mqtt.user = ''
|
|
mqtt.passwd = ''
|
|
|
|
|
|
# home-assistant
|
|
ha.auto_conf_prefix = 'homeassistant' # MQTT prefix for subscribing for homeassistant status updates
|
|
ha.discovery_prefix = 'homeassistant' # MQTT prefix for discovery topic
|
|
ha.entity_prefix = 'tsun' # MQTT topic prefix for publishing inverter values
|
|
ha.proxy_node_id = 'proxy' # MQTT node id, for the proxy_node_id
|
|
ha.proxy_unique_id = 'P170000000000001' # MQTT unique id, to identify a proxy instance
|
|
|
|
# microinverters
|
|
inverters.allow_all = true # allow inverters, even if we have no inverter mapping
|
|
|
|
# inverter mapping, maps a `serial_no* to a `mqtt_id` and defines an optional `suggested_place` for `home-assistant`
|
|
#
|
|
# for each inverter add a block starting with [inverters."<16-digit serial numbeer>"]
|
|
[inverters."R170000000000001"]
|
|
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
|
#suggested_area = '' # Optional, suggested installation area for home-assistant
|
|
#pv1 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
#pv2 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
|
|
#[inverters."R17xxxxxxxxxxxx2"]
|
|
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
|
#suggested_area = '' # Optional, suggested installation area for home-assistant
|
|
#pv1 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
#pv2 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
|
|
[inverters."Y170000000000001"]
|
|
monitor_sn = 2000000000 # The "Monitoring SN:" can be found on a sticker enclosed with the inverter
|
|
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
|
#suggested_area = '' # Optional, suggested installation place for home-assistant
|
|
#client_mode = {host = '192.168.0.1', port = 8899}
|
|
#pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
#pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
#pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
#pv4 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
|
|
|
[gen3plus.at_acl]
|
|
tsun.allow = ['AT+Z', 'AT+UPURL', 'AT+SUPDATE']
|
|
tsun.block = []
|
|
mqtt.allow = ['AT+']
|
|
mqtt.block = []
|