Files
tsun-gen3-proxy/app/src/cnf/default_config.toml
Stefan Allius 632498c384 S allius/issue327 (#328)
* fix typo

* add DCU-1000 storage systems/batteries

* fix compatiblity table

* concern ms3000 support
2025-03-26 23:24:56 +01:00

205 lines
9.2 KiB
TOML

##########################################################################################
###
### T S U N - G E N 3 - P R O X Y
###
### from Stefan Allius
###
##########################################################################################
###
### The readme will give you an overview of the project:
### https://s-allius.github.io/tsun-gen3-proxy/
###
### The proxy supports different operation modes. Select the proper mode
### which depends on your inverter type and you inverter firmware.
### Please read:
### https://github.com/s-allius/tsun-gen3-proxy/wiki/Operation-Modes-Overview
###
### Here you will find a description of all configuration options:
### https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml
###
### The configration uses the TOML format, which aims to be easy to read due to
### obvious semantics. You find more details here: https://toml.io/en/v1.0.0
###
##########################################################################################
##########################################################################################
##
## MQTT broker configuration
##
## In this block, you must configure the connection to your MQTT broker and specify the
## required credentials. As the proxy does not currently support an encrypted connection
## to the MQTT broker, it is strongly recommended that you do not use a public broker.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#mqtt-broker-account
##
mqtt.host = 'mqtt' # URL or IP address of the mqtt broker
mqtt.port = 1883
mqtt.user = ''
mqtt.passwd = ''
##########################################################################################
##
## HOME ASSISTANT
##
## The proxy supports the MQTT autoconfiguration of Home Assistant (HA). The default
## values match the HA default configuration. If you need to change these or want to use
## a different MQTT client, you can adjust the prefixes of the MQTT topics below.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#home-assistant
##
ha.auto_conf_prefix = 'homeassistant' # MQTT prefix for subscribing for homeassistant status updates
ha.discovery_prefix = 'homeassistant' # MQTT prefix for discovery topic
ha.entity_prefix = 'tsun' # MQTT topic prefix for publishing inverter values
ha.proxy_node_id = 'proxy' # MQTT node id, for the proxy_node_id
ha.proxy_unique_id = 'P170000000000001' # MQTT unique id, to identify a proxy instance
##########################################################################################
##
## GEN3 Proxy Mode Configuration
##
## In this block, you can configure an optional connection to the TSUN cloud for GEN3
## inverters. This connection is only required if you want send data to the TSUN cloud
## to use the TSUN APPs or receive firmware updates.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#tsun-cloud-for-gen3-inverter-only
##
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
tsun.host = 'logger.talent-monitoring.com'
tsun.port = 5005
##########################################################################################
##
## GEN3PLUS Proxy Mode Configuration
##
## In this block, you can configure an optional connection to the TSUN cloud for GEN3PLUS
## inverters. This connection is only required if you want send data to the TSUN cloud
## to use the TSUN APPs or receive firmware updates.
##
## https://github.com/s-allius/tsun-gen3-proxy/wiki/Configuration-toml#solarman-cloud-for-gen3plus-inverter-only
##
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
solarman.host = 'iot.talent-monitoring.com'
solarman.port = 10000
##########################################################################################
###
### Inverter Definitions
###
### The proxy supports the simultaneous operation of several inverters, even of different
### types. A configuration block must be defined for each inverter, in which all necessary
### parameters must be specified. These depend on the operation mode used and also differ
### slightly depending on the inverter type.
###
### In addition, the PV modules can be defined at the individual inputs for documentation
### purposes, whereby these are displayed in Home Assistant.
###
### The proxy only accepts connections from known inverters. This can be switched off for
### test purposes and unknown serial numbers are also accepted.
###
inverters.allow_all = false # only allow known inverters
##########################################################################################
##
## For each GEN3 inverter, the serial number of the inverter must be mapped to an MQTT
## definition. To do this, the corresponding configuration block is started with
## `[inverters.“<16-digit serial number>”]` so that all subsequent parameters are assigned
## to this inverter. Further inverter-specific parameters (e.g. polling mode) can be set
## in the configuration block
##
## The serial numbers of all GEN3 inverters start with `R17`!
##
[inverters."R170000000000001"]
node_id = '' # MQTT replacement for inverters serial number
suggested_area = '' # suggested installation area for home-assistant
modbus_polling = false # Disable optional MODBUS polling
pv1 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
pv2 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
##########################################################################################
##
## For each GEN3PLUS inverter, the serial number of the inverter must be mapped to an MQTT
## definition. To do this, the corresponding configuration block is started with
## `[inverters.“<16-digit serial number>”]` so that all subsequent parameters are assigned
## to this inverter. Further inverter-specific parameters (e.g. polling mode, client mode)
## can be set in the configuration block
##
## The serial numbers of all GEN3PLUS inverters start with `Y17` or Y47! Each GEN3PLUS
## inverter is supplied with a “Monitoring SN:”. This can be found on a sticker enclosed
## with the inverter.
##
[inverters."Y170000000000001"]
monitor_sn = 2000000000 # The GEN3PLUS "Monitoring SN:"
node_id = '' # MQTT replacement for inverters serial number
suggested_area = '' # suggested installation place for home-assistant
modbus_polling = true # Enable optional MODBUS polling
# if your inverter supports SSL connections you must use the client_mode. Pls, uncomment
# the next line and configure the fixed IP of your inverter
#client_mode = {host = '192.168.0.1', port = 8899, forward = true}
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv4 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
##########################################################################################
##
## For each GEN3PLUS energy storage system, the serial number must be mapped to an MQTT
## definition. To do this, the corresponding configuration block is started with
## `[batteries.“<16-digit serial number>”]` so that all subsequent parameters are assigned
## to this energy storage system. Further device-specific parameters (e.g. polling mode,
## client mode) can be set in the configuration block
##
## The serial numbers of all GEN3PLUS energy storage systems/batteries start with `410`!
## Each GEN3PLUS device is supplied with a “Monitoring SN:”. This can be found on a
## sticker enclosed with the inverter.
##
[batteries."4100000000000001"]
monitor_sn = 3000000000 # The GEN3PLUS "Monitoring SN:"
node_id = '' # MQTT replacement for devices serial number
suggested_area = '' # suggested installation place for home-assistant
modbus_polling = true # Enable optional MODBUS polling
# if your inverter supports SSL connections you must use the client_mode. Pls, uncomment
# the next line and configure the fixed IP of your inverter
#client_mode = {host = '192.168.0.1', port = 8899, forward = true}
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
##########################################################################################
###
### If the proxy mode is configured, commands from TSUN can be sent to the inverter via
### this connection or parameters (e.g. network credentials) can be queried. Filters can
### then be configured for the AT+ commands from the TSUN Cloud so that only certain
### accesses are permitted.
###
### An overview of all known AT+ commands can be found here:
### https://github.com/s-allius/tsun-gen3-proxy/wiki/AT--commands
###
[gen3plus.at_acl]
# filter for received commands from the internet
tsun.allow = ['AT+Z', 'AT+UPURL', 'AT+SUPDATE']
tsun.block = []
# filter for received commands from the MQTT broker
mqtt.allow = ['AT+']
mqtt.block = []