import struct, json, logging, os
|
|
|
|
|
|
|
|
class Infos:
|
|
stat = {}
|
|
app_name = os.getenv('SERVICE_NAME', 'proxy')
|
|
version = os.getenv('VERSION', 'unknown')
|
|
|
|
@classmethod
|
|
def static_init(cls):
|
|
logging.info('Initialize proxy statistics')
|
|
# init proxy counter in the class.stat dictionary
|
|
cls.stat['proxy'] = {}
|
|
for key in cls.__info_defs:
|
|
name = cls.__info_defs[key]['name']
|
|
if name[0]=='proxy':
|
|
cls.stat['proxy'][name[1]] = 0
|
|
|
|
# add values from the environment to the device definition table
|
|
prxy = cls.__info_devs['proxy']
|
|
prxy['sw'] = cls.version
|
|
prxy['mdl'] = cls.app_name
|
|
|
|
|
|
def __init__(self):
|
|
self.db = {}
|
|
self.tracer = logging.getLogger('data')
|
|
|
|
__info_devs={
|
|
'proxy': {'singleton': True, 'name':'Proxy', 'mf':'Stefan Allius'},
|
|
'controller':{'via':'proxy', 'name':'Controller', 'mdl':0x00092f90, 'mf':0x000927c0, 'sw':0x00092ba8},
|
|
'inverter': {'via':'controller', 'name':'Micro Inverter', 'mdl':0x00000032, 'mf':0x00000014, 'sw':0x0000001e},
|
|
'input_pv1': {'via':'inverter', 'name':'Module PV1'},
|
|
'input_pv2': {'via':'inverter', 'name':'Module PV2', 'dep':{'reg':0x00095b50, 'gte': 2}},
|
|
'input_pv3': {'via':'inverter', 'name':'Module PV3', 'dep':{'reg':0x00095b50, 'gte': 3}},
|
|
'input_pv4': {'via':'inverter', 'name':'Module PV4', 'dep':{'reg':0x00095b50, 'gte': 4}},
|
|
}
|
|
|
|
__info_defs={
|
|
# collector values used for device registration:
|
|
0x00092ba8: {'name':['collector', 'Collector_Fw_Version'], 'level': logging.INFO, 'unit': ''},
|
|
0x000927c0: {'name':['collector', 'Chip_Type'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00092f90: {'name':['collector', 'Chip_Model'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00095a88: {'name':['collector', 'Trace_URL'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00095aec: {'name':['collector', 'Logger_URL'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00095b50: {'name':['collector', 'No_Inputs'], 'level': logging.DEBUG, 'unit': ''},
|
|
|
|
# inverter values used for device registration:
|
|
0x0000000a: {'name':['inverter', 'Product_Name'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000014: {'name':['inverter', 'Manufacturer'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x0000001e: {'name':['inverter', 'Version'], 'level': logging.INFO, 'unit': ''},
|
|
0x00000028: {'name':['inverter', 'Serial_Number'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000032: {'name':['inverter', 'Equipment_Model'], 'level': logging.DEBUG, 'unit': ''},
|
|
|
|
# proxy:
|
|
0xffffff00: {'name':['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha':{'dev':'proxy', 'comp' : 'sensor', 'dev_cla': None, 'stat_cla': None, 'id':'inv_count_', 'fmt':'| int', 'name': 'Active Inverter Connections', 'icon':'mdi:counter'}},
|
|
0xffffff01: {'name':['proxy', 'Unknown_SNR'], 'singleton': True, 'ha':{'dev':'proxy', 'comp' : 'sensor', 'dev_cla': None, 'stat_cla': None, 'id':'unknown_snr_', 'fmt':'| int', 'name': 'Unknown Serial No', 'icon':'mdi:counter', 'ent_cat':'diagnostic'}},
|
|
0xffffff02: {'name':['proxy', 'Unknown_Msg'], 'singleton': True, 'ha':{'dev':'proxy', 'comp' : 'sensor', 'dev_cla': None, 'stat_cla': None, 'id':'unknown_msg_', 'fmt':'| int', 'name': 'Unknown Msg Type', 'icon':'mdi:counter', 'ent_cat':'diagnostic'}},
|
|
0xffffff03: {'name':['proxy', 'Invalid_Data_Type'], 'singleton': True, 'ha':{'dev':'proxy', 'comp' : 'sensor', 'dev_cla': None, 'stat_cla': None, 'id':'inv_data_type_', 'fmt':'| int', 'name': 'Invalid Data Type','icon':'mdi:counter', 'ent_cat':'diagnostic'}},
|
|
0xffffff04: {'name':['proxy', 'Internal_Error'], 'singleton': True, 'ha':{'dev':'proxy', 'comp' : 'sensor', 'dev_cla': None, 'stat_cla': None, 'id':'intern_err_', 'fmt':'| int', 'name': 'Internal Error', 'icon':'mdi:counter', 'ent_cat':'diagnostic', 'en':False}},
|
|
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':'| float','name': 'Grid Voltage'}},
|
|
|
|
# events
|
|
0x00000191: {'name':['events', '401_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000192: {'name':['events', '402_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000193: {'name':['events', '403_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000194: {'name':['events', '404_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000195: {'name':['events', '405_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000196: {'name':['events', '406_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000197: {'name':['events', '407_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000198: {'name':['events', '408_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x00000199: {'name':['events', '409_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x0000019a: {'name':['events', '410_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x0000019b: {'name':['events', '411_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x0000019c: {'name':['events', '412_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x0000019d: {'name':['events', '413_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x0000019e: {'name':['events', '414_'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x0000019f: {'name':['events', '415_GridFreqOverRating'], 'level': logging.DEBUG, 'unit': ''},
|
|
0x000001a0: {'name':['events', '416_'], 'level': logging.DEBUG, 'unit': ''},
|
|
|
|
# grid measures:
|
|
0x000003e8: {'name':['grid', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'inverter', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'out_volt_', 'fmt':'| float','name': 'Grid Voltage','ent_cat':'diagnostic'}},
|
|
0x0000044c: {'name':['grid', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha':{'dev':'inverter', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id':'out_cur_', 'fmt':'| float','name': 'Grid Current','ent_cat':'diagnostic'}},
|
|
0x000004b0: {'name':['grid', 'Frequency'], 'level': logging.DEBUG, 'unit': 'Hz', 'ha':{'dev':'inverter', 'dev_cla': 'frequency', 'stat_cla': 'measurement', 'id':'out_freq_', 'fmt':'| float','name': 'Grid Frequency','ent_cat':'diagnostic'}},
|
|
0x00000640: {'name':['grid', 'Output_Power'], 'level': logging.INFO, 'unit': 'W', 'ha':{'dev':'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id':'out_power_', 'fmt':'| float','name': 'Power'}},
|
|
0x000005dc: {'name':['env', 'Rated_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha':{'dev':'inverter', 'dev_cla': None, 'stat_cla': None, 'id':'rated_power_', 'fmt':'| int', 'name': 'Rated Power','ent_cat':'diagnostic'}},
|
|
0x00000514: {'name':['env', 'Inverter_Temp'], 'level': logging.DEBUG, 'unit': '°C', 'ha':{'dev':'inverter', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id':'temp_', 'fmt':'| int','name': 'Temperature'}},
|
|
|
|
# input measures:
|
|
0x000006a4: {'name':['input', 'pv1', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'input_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'volt_pv1_', 'val_tpl' :"{{ (value_json['pv1']['Voltage'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x00000708: {'name':['input', 'pv1', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha':{'dev':'input_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id':'cur_pv1_', 'val_tpl' :"{{ (value_json['pv1']['Current'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x0000076c: {'name':['input', 'pv1', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha':{'dev':'input_pv1', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id':'power_pv1_','val_tpl' :"{{ (value_json['pv1']['Power'] | float)}}"}},
|
|
0x000007d0: {'name':['input', 'pv2', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'input_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'volt_pv2_', 'val_tpl' :"{{ (value_json['pv2']['Voltage'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x00000834: {'name':['input', 'pv2', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha':{'dev':'input_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id':'cur_pv2_', 'val_tpl' :"{{ (value_json['pv2']['Current'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x00000898: {'name':['input', 'pv2', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha':{'dev':'input_pv2', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id':'power_pv2_','val_tpl' :"{{ (value_json['pv2']['Power'] | float)}}"}},
|
|
0x000008fc: {'name':['input', 'pv3', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'input_pv3', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'volt_pv3_', 'val_tpl' :"{{ (value_json['pv3']['Voltage'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x00000960: {'name':['input', 'pv3', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha':{'dev':'input_pv3', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id':'cur_pv3_', 'val_tpl' :"{{ (value_json['pv3']['Current'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x000009c4: {'name':['input', 'pv3', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha':{'dev':'input_pv3', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id':'power_pv3_','val_tpl' :"{{ (value_json['pv3']['Power'] | float)}}"}},
|
|
0x00000a28: {'name':['input', 'pv4', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'input_pv4', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'volt_pv4_', 'val_tpl' :"{{ (value_json['pv4']['Voltage'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x00000a8c: {'name':['input', 'pv4', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha':{'dev':'input_pv4', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id':'cur_pv4_', 'val_tpl' :"{{ (value_json['pv4']['Current'] | float)}}", 'icon':'mdi:gauge','ent_cat':'diagnostic'}},
|
|
0x00000af0: {'name':['input', 'pv4', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha':{'dev':'input_pv4', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id':'power_pv4_','val_tpl' :"{{ (value_json['pv4']['Power'] | float)}}"}},
|
|
0x00000c1c: {'name':['input', 'pv1', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv1', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id':'daily_gen_pv1_','name': 'Daily Generation', 'val_tpl' :"{{ (value_json['pv1']['Daily_Generation'] | float)}}", 'icon':'mdi:solar-power-variant', 'must_incr':True}},
|
|
0x00000c80: {'name':['input', 'pv1', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv1', 'dev_cla': 'energy', 'stat_cla': 'total', 'id':'total_gen_pv1_','name': 'Total Generation', 'val_tpl' :"{{ (value_json['pv1']['Total_Generation'] | float)}}", 'icon':'mdi:solar-power', 'must_incr':True}},
|
|
0x00000ce4: {'name':['input', 'pv2', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv2', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id':'daily_gen_pv2_','name': 'Daily Generation', 'val_tpl' :"{{ (value_json['pv2']['Daily_Generation'] | float)}}", 'icon':'mdi:solar-power-variant', 'must_incr':True}},
|
|
0x00000d48: {'name':['input', 'pv2', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv2', 'dev_cla': 'energy', 'stat_cla': 'total', 'id':'total_gen_pv2_','name': 'Total Generation', 'val_tpl' :"{{ (value_json['pv2']['Total_Generation'] | float)}}", 'icon':'mdi:solar-power', 'must_incr':True}},
|
|
0x00000dac: {'name':['input', 'pv3', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv3', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id':'daily_gen_pv3_','name': 'Daily Generation', 'val_tpl' :"{{ (value_json['pv3']['Daily_Generation'] | float)}}", 'icon':'mdi:solar-power-variant', 'must_incr':True}},
|
|
0x00000e10: {'name':['input', 'pv3', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv3', 'dev_cla': 'energy', 'stat_cla': 'total', 'id':'total_gen_pv3_','name': 'Total Generation', 'val_tpl' :"{{ (value_json['pv3']['Total_Generation'] | float)}}", 'icon':'mdi:solar-power', 'must_incr':True}},
|
|
0x00000e74: {'name':['input', 'pv4', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv4', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id':'daily_gen_pv4_','name': 'Daily Generation', 'val_tpl' :"{{ (value_json['pv4']['Daily_Generation'] | float)}}", 'icon':'mdi:solar-power-variant', 'must_incr':True}},
|
|
0x00000ed8: {'name':['input', 'pv4', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha':{'dev':'input_pv4', 'dev_cla': 'energy', 'stat_cla': 'total', 'id':'total_gen_pv4_','name': 'Total Generation', 'val_tpl' :"{{ (value_json['pv4']['Total_Generation'] | float)}}", 'icon':'mdi:solar-power', 'must_incr':True}},
|
|
# total:
|
|
0x00000b54: {'name':['total', 'Daily_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha':{'dev':'inverter', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id':'daily_gen_', 'fmt':'| float','name': 'Daily Generation', 'icon':'mdi:solar-power-variant', 'must_incr':True}},
|
|
0x00000bb8: {'name':['total', 'Total_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha':{'dev':'inverter', 'dev_cla': 'energy', 'stat_cla': 'total', 'id':'total_gen_', 'fmt':'| float','name': 'Total Generation', 'icon':'mdi:solar-power', 'must_incr':True}},
|
|
|
|
# controller:
|
|
0x000c3500: {'name':['controller', 'Signal_Strength'], 'level': logging.DEBUG, 'unit': '%' , 'ha':{'dev':'controller', 'dev_cla': None, 'stat_cla': 'measurement', 'id':'signal_', 'fmt':'| int', 'name': 'Signal Strength', 'icon':'mdi:wifi'}},
|
|
0x000c96a8: {'name':['controller', 'Power_On_Time'], 'level': logging.DEBUG, 'unit': 's', 'ha':{'dev':'controller', 'dev_cla': 'duration', 'stat_cla': 'measurement', 'id':'power_on_time_', 'name': 'Power on Time', 'val_tpl':"{{ (value_json['Power_On_Time'] | float)}}", 'nat_prc':'3','ent_cat':'diagnostic'}},
|
|
0x000cf850: {'name':['controller', 'Data_Up_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha':{'dev':'controller', 'dev_cla': None, 'stat_cla': 'measurement', 'id':'data_up_intval_', 'fmt':'| int', 'name': 'Data Up Interval', 'icon':'mdi:update','ent_cat':'diagnostic'}},
|
|
|
|
}
|
|
|
|
def dev_value(self, idx:str|int) -> str|int|float|None:
|
|
'''returns the stored device value from our database
|
|
|
|
idx:int ==> lookup the value in the database and return it as str, int or flout. If the value is not available return 'None'
|
|
idx:str ==> returns the string as a fixed value without a database loopup
|
|
'''
|
|
if type (idx) is str:
|
|
return idx # return idx as a fixed value
|
|
elif idx in self.__info_defs:
|
|
row = self.__info_defs[idx]
|
|
if 'singleton' in row and row['singleton']:
|
|
dict = self.stat
|
|
else:
|
|
dict = self.db
|
|
|
|
keys = row['name']
|
|
|
|
for key in keys:
|
|
if key not in dict:
|
|
return None # value not found in the database
|
|
dict = dict[key]
|
|
return dict # value of the reqeusted entry
|
|
|
|
return None # unknwon idx, not in __info_defs
|
|
|
|
def ignore_this_device(self, dep:dict) -> bool:
|
|
'''Checks the equation in the dep dict
|
|
|
|
returns 'False' only if the equation is valid; 'True' in any other case'''
|
|
if 'reg' in dep:
|
|
value = self.dev_value(dep['reg'])
|
|
if not value: return True
|
|
|
|
if 'gte' in dep:
|
|
return not value >= dep['gte']
|
|
elif 'less_eq' in dep:
|
|
return not value <= dep['less_eq']
|
|
return True
|
|
|
|
def ha_confs(self, ha_prfx, inv_node_id, inv_snr, proxy_node_id, proxy_unique_id, sug_area =''):
|
|
'''Generator function yields a json register struct for home-assistant auto configuration and a unique entity string
|
|
|
|
arguments:
|
|
prfx:str ==> MQTT prefix for the home assistant 'stat_t string
|
|
snr:str ==> serial number of the inverter, used to build unique entity strings
|
|
sug_area:str ==> suggested area string from the config file'''
|
|
tab = self.__info_defs
|
|
for key in tab:
|
|
row = tab[key]
|
|
if 'singleton' in row and row['singleton']:
|
|
node_id = proxy_node_id
|
|
snr = proxy_unique_id
|
|
else:
|
|
node_id = inv_node_id
|
|
snr = inv_snr
|
|
prfx = ha_prfx + node_id
|
|
|
|
#check if we have details for home assistant
|
|
if 'ha' in row:
|
|
ha = row['ha']
|
|
if 'comp' in ha:
|
|
component = ha['comp']
|
|
else:
|
|
component = 'sensor'
|
|
attr = {} # dict to collect all the sensor entity details
|
|
if 'name' in ha:
|
|
attr['name'] = ha['name'] # take the entity name from the ha dict
|
|
else:
|
|
attr['name'] = row['name'][-1] # otherwise take a name from the name array
|
|
|
|
attr['stat_t'] = prfx +row['name'][0] # eg. 'stat_t': "tsun/garagendach/grid"
|
|
attr['dev_cla'] = ha['dev_cla'] # eg. 'dev_cla': 'power'
|
|
attr['stat_cla'] = ha['stat_cla'] # eg. 'stat_cla': "measurement"
|
|
attr['uniq_id'] = ha['id']+snr # build the 'uniq_id' from the id str + the serial no of the inverter
|
|
if 'val_tpl' in ha:
|
|
attr['val_tpl'] = ha['val_tpl'] # get value template for complexe data structures
|
|
elif 'fmt' in ha:
|
|
attr['val_tpl'] = '{{value_json' + f"['{row['name'][-1]}'] {ha['fmt']}" + '}}' # eg. 'val_tpl': "{{ value_json['Output_Power']|float }}"
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.__info_defs: the row for {key} do not have a 'val_tpl' nor a 'fmt' value")
|
|
|
|
# add unit_of_meas only, if status_class isn't none. If status_cla is None we want a number format and not line graph in home assistant.
|
|
# A unit will change the number format to a line graph
|
|
if 'unit' in row and attr['stat_cla'] != None:
|
|
attr['unit_of_meas'] = row['unit'] # optional add a 'unit_of_meas' e.g. 'W'
|
|
if 'icon' in ha:
|
|
attr['ic'] = ha['icon'] # optional add an icon for the entity
|
|
if 'nat_prc' in ha:
|
|
attr['sug_dsp_prc'] = ha['nat_prc'] # optional add the precison of floats
|
|
if 'ent_cat' in ha:
|
|
attr['ent_cat'] = ha['ent_cat'] # diagnostic, config
|
|
|
|
# enabled_by_default is deactivated, since it avoid the via setup of the devices
|
|
# it seems, that there is a bug in home assistant. tested with 'Home Assistant 2023.10.4'
|
|
#if 'en' in ha: # enabled_by_default
|
|
# attr['en'] = ha['en']
|
|
|
|
# eg. 'dev':{'name':'Microinverter','mdl':'MS-600','ids':["inverter_123"],'mf':'TSUN','sa': 'auf Garagendach'}
|
|
# attr['dev'] = {'name':'Microinverter','mdl':'MS-600','ids':[f'inverter_{snr}'],'mf':'TSUN','sa': 'auf Garagendach'}
|
|
if 'dev' in ha:
|
|
device = self.__info_devs[ha['dev']]
|
|
|
|
if 'dep' in device and self.ignore_this_device(device['dep']):
|
|
continue
|
|
|
|
dev = {}
|
|
|
|
# the same name for 'name' and 'suggested area', so we get dedicated devices in home assistant with short value name and headline
|
|
if sug_area == '' or ('singleton' in device and device['singleton']):
|
|
dev['name'] = device['name']
|
|
dev['sa'] = device['name']
|
|
else:
|
|
dev['name'] = device['name']+' - '+sug_area
|
|
dev['sa'] = device['name']+' - '+sug_area
|
|
|
|
if 'via' in device: # add the link to the parent device
|
|
via = device['via']
|
|
if via in self.__info_devs:
|
|
via_dev = self.__info_devs[via]
|
|
if 'singleton' in via_dev and via_dev['singleton']:
|
|
dev['via_device'] = via
|
|
else:
|
|
dev['via_device'] = f"{via}_{snr}"
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.__info_defs: the row for {key} has an invalid via value: {via}")
|
|
|
|
|
|
|
|
for key in ('mdl','mf', 'sw', 'hw'): # add optional values fpr 'modell', 'manufaturer', 'sw version' and 'hw version'
|
|
if key in device:
|
|
data = self.dev_value(device[key])
|
|
if data is not None: dev[key] = data
|
|
|
|
if 'singleton' in device and device['singleton']:
|
|
dev['ids'] = [f"{ha['dev']}"]
|
|
else:
|
|
dev['ids'] = [f"{ha['dev']}_{snr}"]
|
|
|
|
attr['dev'] = dev
|
|
|
|
origin = {}
|
|
origin['name'] = self.app_name
|
|
origin['sw'] = self.version
|
|
attr['o'] = origin
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.__info_defs: the row for {key} missing 'dev' value for ha register")
|
|
|
|
|
|
yield json.dumps (attr), component, node_id, attr['uniq_id']
|
|
|
|
def inc_counter (self, counter:str) -> None:
|
|
'''inc proxy statistic counter'''
|
|
dict = self.stat['proxy']
|
|
dict[counter] += 1
|
|
|
|
def dec_counter (self, counter:str) -> None:
|
|
'''dec proxy statistic counter'''
|
|
dict = self.stat['proxy']
|
|
dict[counter] -= 1
|
|
|
|
|
|
def __key_obj(self, id) -> list:
|
|
d = self.__info_defs.get(id, {'name': None, 'level': logging.DEBUG, 'unit': ''})
|
|
if 'ha' in d and 'must_incr' in d['ha']:
|
|
must_incr = d['ha']['must_incr']
|
|
else:
|
|
must_incr = False
|
|
|
|
return d['name'], d['level'], d['unit'], must_incr
|
|
|
|
|
|
def parse(self, buf) -> None:
|
|
'''parse a data sequence received from the inverter and stores the values in Infos.db
|
|
|
|
buf: buffer of the sequence to parse'''
|
|
result = struct.unpack_from('!l', buf, 0)
|
|
elms = result[0]
|
|
i = 0
|
|
ind = 4
|
|
while i < elms:
|
|
result = struct.unpack_from('!lB', buf, ind)
|
|
info_id = result[0]
|
|
data_type = result[1]
|
|
ind += 5
|
|
keys, level, unit, must_incr = self.__key_obj(info_id)
|
|
|
|
if data_type==0x54: # 'T' -> Pascal-String
|
|
str_len = buf[ind]
|
|
result = struct.unpack_from(f'!{str_len+1}p', buf, ind)[0].decode(encoding='ascii', errors='replace')
|
|
ind += str_len+1
|
|
|
|
elif data_type==0x49: # 'I' -> int32
|
|
result = struct.unpack_from(f'!l', buf, ind)[0]
|
|
ind += 4
|
|
|
|
elif data_type==0x53: # 'S' -> short
|
|
result = struct.unpack_from(f'!h', buf, ind)[0]
|
|
ind += 2
|
|
|
|
elif data_type==0x46: # 'F' -> float32
|
|
result = round(struct.unpack_from(f'!f', buf, ind)[0],2)
|
|
ind += 4
|
|
else:
|
|
self.inc_counter('Invalid_Data_Type')
|
|
logging.error(f"Infos.parse: data_type: {data_type} not supported")
|
|
return
|
|
|
|
|
|
|
|
if keys:
|
|
dict = self.db
|
|
name = ''
|
|
|
|
for key in keys[:-1]:
|
|
if key not in dict:
|
|
dict[key] = {}
|
|
dict = dict[key]
|
|
name += key + '.'
|
|
|
|
update = keys[-1] not in dict or (not must_incr and dict[keys[-1]] != result) or (must_incr and dict[keys[-1]] < result)
|
|
if update: dict[keys[-1]] = result
|
|
name += keys[-1]
|
|
yield keys[0], update
|
|
else:
|
|
update = False
|
|
name = str(f'info-id.0x{info_id:x}')
|
|
|
|
self.tracer.log(level, f'{name} : {result}{unit}')
|
|
|
|
i +=1
|
|
|
|
|