import logging
|
|
import json
|
|
import struct
|
|
import os
|
|
from enum import Enum
|
|
from typing import Generator
|
|
|
|
|
|
class ProxyMode(Enum):
|
|
SERVER = 1
|
|
CLIENT = 2
|
|
|
|
|
|
class Register(Enum):
|
|
COLLECTOR_FW_VERSION = 1
|
|
CHIP_TYPE = 2
|
|
CHIP_MODEL = 3
|
|
TRACE_URL = 4
|
|
LOGGER_URL = 5
|
|
MAC_ADDR = 6
|
|
COLLECTOR_SNR = 7
|
|
PRODUCT_NAME = 20
|
|
MANUFACTURER = 21
|
|
VERSION = 22
|
|
SERIAL_NUMBER = 23
|
|
EQUIPMENT_MODEL = 24
|
|
NO_INPUTS = 25
|
|
MAX_DESIGNED_POWER = 26
|
|
RATED_LEVEL = 27
|
|
INPUT_COEFFICIENT = 28
|
|
GRID_VOLT_CAL_COEF = 29
|
|
OUTPUT_COEFFICIENT = 30
|
|
PROD_COMPL_TYPE = 31
|
|
INVERTER_CNT = 50
|
|
UNKNOWN_SNR = 51
|
|
UNKNOWN_MSG = 52
|
|
INVALID_DATA_TYPE = 53
|
|
INTERNAL_ERROR = 54
|
|
UNKNOWN_CTRL = 55
|
|
OTA_START_MSG = 56
|
|
SW_EXCEPTION = 57
|
|
INVALID_MSG_FMT = 58
|
|
AT_COMMAND = 59
|
|
MODBUS_COMMAND = 60
|
|
AT_COMMAND_BLOCKED = 61
|
|
CLOUD_CONN_CNT = 62
|
|
OUTPUT_POWER = 83
|
|
RATED_POWER = 84
|
|
INVERTER_TEMP = 85
|
|
INVERTER_STATUS = 86
|
|
DETECT_STATUS_1 = 87
|
|
DETECT_STATUS_2 = 88
|
|
PV1_VOLTAGE = 100
|
|
PV1_CURRENT = 101
|
|
PV1_POWER = 102
|
|
PV1_MANUFACTURER = 103
|
|
PV1_MODEL = 104
|
|
PV2_VOLTAGE = 110
|
|
PV2_CURRENT = 111
|
|
PV2_POWER = 112
|
|
PV2_MANUFACTURER = 113
|
|
PV2_MODEL = 114
|
|
PV3_VOLTAGE = 120
|
|
PV3_CURRENT = 121
|
|
PV3_POWER = 122
|
|
PV3_MANUFACTURER = 123
|
|
PV3_MODEL = 124
|
|
PV4_VOLTAGE = 130
|
|
PV4_CURRENT = 131
|
|
PV4_POWER = 132
|
|
PV4_MANUFACTURER = 133
|
|
PV4_MODEL = 134
|
|
PV5_VOLTAGE = 140
|
|
PV5_CURRENT = 141
|
|
PV5_POWER = 142
|
|
PV5_MANUFACTURER = 143
|
|
PV5_MODEL = 144
|
|
PV6_VOLTAGE = 150
|
|
PV6_CURRENT = 151
|
|
PV6_POWER = 152
|
|
PV6_MANUFACTURER = 153
|
|
PV6_MODEL = 154
|
|
PV1_DAILY_GENERATION = 200
|
|
PV1_TOTAL_GENERATION = 201
|
|
PV2_DAILY_GENERATION = 210
|
|
PV2_TOTAL_GENERATION = 211
|
|
PV3_DAILY_GENERATION = 220
|
|
PV3_TOTAL_GENERATION = 221
|
|
PV4_DAILY_GENERATION = 230
|
|
PV4_TOTAL_GENERATION = 231
|
|
PV5_DAILY_GENERATION = 240
|
|
PV5_TOTAL_GENERATION = 241
|
|
PV6_DAILY_GENERATION = 250
|
|
PV6_TOTAL_GENERATION = 251
|
|
INV_UNKNOWN_1 = 252
|
|
BOOT_STATUS = 253
|
|
DSP_STATUS = 254
|
|
WORK_MODE = 255
|
|
OUTPUT_SHUTDOWN = 256
|
|
|
|
GRID_VOLTAGE = 300
|
|
GRID_CURRENT = 301
|
|
GRID_FREQUENCY = 302
|
|
DAILY_GENERATION = 303
|
|
TOTAL_GENERATION = 304
|
|
COMMUNICATION_TYPE = 400
|
|
SIGNAL_STRENGTH = 401
|
|
POWER_ON_TIME = 402
|
|
COLLECT_INTERVAL = 403
|
|
DATA_UP_INTERVAL = 404
|
|
CONNECT_COUNT = 405
|
|
HEARTBEAT_INTERVAL = 406
|
|
IP_ADDRESS = 407
|
|
POLLING_INTERVAL = 408
|
|
SENSOR_LIST = 409
|
|
SSID = 410
|
|
EVENT_ALARM = 500
|
|
EVENT_FAULT = 501
|
|
EVENT_BF1 = 502
|
|
EVENT_BF2 = 503
|
|
TS_INPUT = 600
|
|
TS_GRID = 601
|
|
TS_TOTAL = 602
|
|
BATT_PV1_VOLT = 1000
|
|
BATT_PV1_CUR = 1001
|
|
BATT_PV2_VOLT = 1002
|
|
BATT_PV2_CUR = 1003
|
|
BATT_TOTAL_CHARG = 1005
|
|
BATT_STATUS_1 = 1006
|
|
BATT_STATUS_2 = 1007
|
|
BATT_VOLT = 1010
|
|
BATT_CUR = 1011
|
|
BATT_SOC = 1012
|
|
BATT_CELL1_VOLT = 1013
|
|
BATT_CELL2_VOLT = 1014
|
|
BATT_CELL3_VOLT = 1015
|
|
BATT_CELL4_VOLT = 1016
|
|
BATT_CELL5_VOLT = 1017
|
|
BATT_CELL6_VOLT = 1018
|
|
BATT_CELL7_VOLT = 1019
|
|
BATT_CELL8_VOLT = 1020
|
|
BATT_CELL9_VOLT = 1021
|
|
BATT_CELL10_VOLT = 1022
|
|
BATT_CELL11_VOLT = 1023
|
|
BATT_CELL12_VOLT = 1024
|
|
BATT_CELL13_VOLT = 1025
|
|
BATT_CELL14_VOLT = 1026
|
|
BATT_CELL15_VOLT = 1027
|
|
BATT_CELL16_VOLT = 1028
|
|
BATT_TEMP_1 = 1029
|
|
BATT_TEMP_2 = 1030
|
|
BATT_TEMP_3 = 1031
|
|
BATT_OUT_VOLT = 1032
|
|
BATT_OUT_CUR = 1033
|
|
BATT_OUT_STATUS = 1034
|
|
BATT_TEMP_4 = 1035
|
|
BATT_74 = 1036
|
|
BATT_HW_VERS = 1037
|
|
BATT_SW_VERS = 1038
|
|
BATT_PV_PWR = 1040
|
|
BATT_PWR = 1041
|
|
BATT_OUT_PWR = 1042
|
|
|
|
TEST_VAL_0 = 2000
|
|
TEST_VAL_1 = 2001
|
|
TEST_VAL_2 = 2002
|
|
TEST_VAL_3 = 2003
|
|
TEST_VAL_4 = 2004
|
|
TEST_VAL_5 = 2005
|
|
TEST_VAL_6 = 2006
|
|
TEST_VAL_7 = 2007
|
|
TEST_VAL_8 = 2008
|
|
TEST_VAL_9 = 2009
|
|
TEST_VAL_10 = 2010
|
|
TEST_VAL_11 = 2011
|
|
TEST_VAL_12 = 2012
|
|
TEST_VAL_13 = 2013
|
|
TEST_VAL_14 = 2014
|
|
TEST_VAL_15 = 2015
|
|
TEST_VAL_16 = 2016
|
|
TEST_VAL_17 = 2017
|
|
TEST_VAL_18 = 2018
|
|
TEST_VAL_19 = 2019
|
|
TEST_VAL_20 = 2020
|
|
TEST_VAL_21 = 2021
|
|
TEST_VAL_22 = 2022
|
|
TEST_VAL_23 = 2023
|
|
TEST_VAL_24 = 2024
|
|
TEST_VAL_25 = 2025
|
|
TEST_VAL_26 = 2026
|
|
TEST_VAL_27 = 2027
|
|
TEST_VAL_28 = 2028
|
|
TEST_VAL_29 = 2029
|
|
TEST_VAL_30 = 2030
|
|
TEST_VAL_31 = 2031
|
|
TEST_VAL_32 = 2032
|
|
|
|
TEST_IVAL_1 = 2041
|
|
TEST_IVAL_2 = 2042
|
|
TEST_IVAL_3 = 2043
|
|
TEST_IVAL_4 = 2044
|
|
TEST_IVAL_5 = 2045
|
|
TEST_IVAL_6 = 2046
|
|
TEST_IVAL_7 = 2047
|
|
TEST_IVAL_8 = 2048
|
|
TEST_IVAL_9 = 2049
|
|
TEST_IVAL_10 = 2050
|
|
TEST_IVAL_11 = 2051
|
|
TEST_IVAL_12 = 2052
|
|
|
|
VALUE_1 = 9000
|
|
TEST_REG1 = 10000
|
|
TEST_REG2 = 10001
|
|
|
|
|
|
class Fmt:
|
|
@staticmethod
|
|
def get_value(buf: bytes, idx: int, row: dict):
|
|
'''Get a value from buf and interpret as in row defined'''
|
|
fmt = row['fmt']
|
|
try:
|
|
res = struct.unpack_from(fmt, buf, idx)
|
|
except Exception:
|
|
return None
|
|
result = res[0]
|
|
if isinstance(result, (bytearray, bytes)):
|
|
result = result.decode().split('\x00')[0]
|
|
if 'func' in row:
|
|
result = row['func'](res)
|
|
if 'ratio' in row:
|
|
result = round(result * row['ratio'], 2)
|
|
if 'quotient' in row:
|
|
result = round(result/row['quotient'])
|
|
if 'offset' in row:
|
|
result = result + row['offset']
|
|
return result
|
|
|
|
@staticmethod
|
|
def hex4(val: tuple | str, reverse=False) -> str | int:
|
|
if not reverse:
|
|
return f'{val[0]:04x}'
|
|
else:
|
|
return int(val, 16)
|
|
|
|
@staticmethod
|
|
def mac(val: tuple | str, reverse=False) -> str | tuple:
|
|
if not reverse:
|
|
return "%02x:%02x:%02x:%02x:%02x:%02x" % val
|
|
else:
|
|
return (
|
|
int(val[0:2], 16), int(val[3:5], 16),
|
|
int(val[6:8], 16), int(val[9:11], 16),
|
|
int(val[12:14], 16), int(val[15:], 16))
|
|
|
|
@staticmethod
|
|
def version(val: tuple | str, reverse=False) -> str | int:
|
|
if not reverse:
|
|
x = val[0]
|
|
return f'V{(x >> 12)}.{(x >> 8) & 0xf}' \
|
|
f'.{(x >> 4) & 0xf}{x & 0xf:1X}'
|
|
else:
|
|
arr = val[1:].split('.')
|
|
return int(arr[0], 10) << 12 | \
|
|
int(arr[1], 10) << 8 | \
|
|
int(arr[2][:-1], 10) << 4 | \
|
|
int(arr[2][-1:], 16)
|
|
|
|
@staticmethod
|
|
def set_value(buf: bytearray, idx: int, row: dict, val):
|
|
'''Get a value from buf and interpret as in row defined'''
|
|
fmt = row['fmt']
|
|
if 'offset' in row:
|
|
val = val - row['offset']
|
|
if 'quotient' in row:
|
|
val = round(val * row['quotient'])
|
|
if 'ratio' in row:
|
|
val = round(val / row['ratio'])
|
|
if 'func' in row:
|
|
val = row['func'](val, reverse=True)
|
|
if isinstance(val, str):
|
|
val = bytes(val, 'UTF8')
|
|
|
|
if isinstance(val, tuple):
|
|
struct.pack_into(fmt, buf, idx, *val)
|
|
else:
|
|
struct.pack_into(fmt, buf, idx, val)
|
|
|
|
|
|
class ClrAtMidnight:
|
|
__clr_at_midnight = [Register.PV1_DAILY_GENERATION, Register.PV2_DAILY_GENERATION, Register.PV3_DAILY_GENERATION, Register.PV4_DAILY_GENERATION, Register.PV5_DAILY_GENERATION, Register.PV6_DAILY_GENERATION, Register.DAILY_GENERATION] # noqa: E501
|
|
db = {}
|
|
|
|
@classmethod
|
|
def add(cls, keys: list, prfx: str, reg: Register) -> None:
|
|
if reg not in cls.__clr_at_midnight:
|
|
return
|
|
|
|
prfx += f'{keys[0]}'
|
|
db_dict = cls.db
|
|
if prfx not in db_dict:
|
|
db_dict[prfx] = {}
|
|
db_dict = db_dict[prfx]
|
|
|
|
for key in keys[1:-1]:
|
|
if key not in db_dict:
|
|
db_dict[key] = {}
|
|
db_dict = db_dict[key]
|
|
db_dict[keys[-1]] = 0
|
|
|
|
@classmethod
|
|
def elm(cls) -> Generator[tuple[str, dict], None, None]:
|
|
for reg, name in cls.db.items():
|
|
yield reg, name
|
|
cls.db = {}
|
|
|
|
|
|
class Infos:
|
|
__slots__ = ('db', 'tracer', )
|
|
|
|
LIGHTNING = 'mdi:lightning-bolt'
|
|
COUNTER = 'mdi:counter'
|
|
GAUGE = 'mdi:gauge'
|
|
POWER = 'mdi:power'
|
|
SOLAR_POWER_VAR = 'mdi:solar-power-variant'
|
|
SOLAR_POWER = 'mdi:solar-power'
|
|
WIFI = 'mdi:wifi'
|
|
UPDATE = 'mdi:update'
|
|
DAILY_GEN = 'Daily Generation'
|
|
TOTAL_GEN = 'Total Generation'
|
|
TOTAL_CHARG = 'Total Charging Energy'
|
|
FMT_INT = '| int'
|
|
FMT_FLOAT = '| float'
|
|
FMT_STRING_SEC = '| string + " s"'
|
|
stat = {}
|
|
app_name = os.getenv('SERVICE_NAME', 'proxy')
|
|
version = os.getenv('VERSION', 'unknown')
|
|
new_stat_data = {}
|
|
|
|
@classmethod
|
|
def static_init(cls):
|
|
logging.debug('Initialize proxy statistics')
|
|
# init proxy counter in the class.stat dictionary
|
|
cls.stat['proxy'] = {}
|
|
for key in cls.__info_defs:
|
|
name = cls.__info_defs[key]['name']
|
|
if name[0] == 'proxy':
|
|
cls.stat['proxy'][name[1]] = 0
|
|
|
|
# add values from the environment to the device definition table
|
|
prxy = cls.__info_devs['proxy']
|
|
prxy['sw'] = cls.version
|
|
prxy['mdl'] = cls.app_name
|
|
|
|
def __init__(self):
|
|
self.db = {}
|
|
self.tracer = logging.getLogger('data')
|
|
|
|
__info_devs = {
|
|
'proxy': {'singleton': True, 'name': 'Proxy', 'mf': 'Stefan Allius'}, # noqa: E501
|
|
'controller': {'via': 'proxy', 'name': 'Controller', 'mdl': Register.CHIP_MODEL, 'mf': Register.CHIP_TYPE, 'sw': Register.COLLECTOR_FW_VERSION, 'mac': Register.MAC_ADDR, 'sn': Register.COLLECTOR_SNR}, # noqa: E501
|
|
|
|
'inverter': {'via': 'controller', 'name': 'Micro Inverter', 'mdl': Register.EQUIPMENT_MODEL, 'mf': Register.MANUFACTURER, 'sw': Register.VERSION, 'sn': Register.SERIAL_NUMBER}, # noqa: E501
|
|
'input_pv1': {'via': 'inverter', 'name': 'Module PV1', 'mdl': Register.PV1_MODEL, 'mf': Register.PV1_MANUFACTURER}, # noqa: E501
|
|
'input_pv2': {'via': 'inverter', 'name': 'Module PV2', 'mdl': Register.PV2_MODEL, 'mf': Register.PV2_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 2}}, # noqa: E501
|
|
'input_pv3': {'via': 'inverter', 'name': 'Module PV3', 'mdl': Register.PV3_MODEL, 'mf': Register.PV3_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 3}}, # noqa: E501
|
|
'input_pv4': {'via': 'inverter', 'name': 'Module PV4', 'mdl': Register.PV4_MODEL, 'mf': Register.PV4_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 4}}, # noqa: E501
|
|
'input_pv5': {'via': 'inverter', 'name': 'Module PV5', 'mdl': Register.PV5_MODEL, 'mf': Register.PV5_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 5}}, # noqa: E501
|
|
'input_pv6': {'via': 'inverter', 'name': 'Module PV6', 'mdl': Register.PV6_MODEL, 'mf': Register.PV6_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 6}}, # noqa: E501
|
|
|
|
'batterie': {'via': 'controller', 'name': 'Batterie', 'mdl': Register.EQUIPMENT_MODEL, 'mf': Register.MANUFACTURER, 'hw': Register.BATT_HW_VERS, 'sw': Register.BATT_SW_VERS, 'sn': Register.SERIAL_NUMBER}, # noqa: E501
|
|
'bat_inp_pv1': {'via': 'batterie', 'name': 'Module PV1', 'mdl': Register.PV1_MODEL, 'mf': Register.PV1_MANUFACTURER}, # noqa: E501
|
|
'bat_inp_pv2': {'via': 'batterie', 'name': 'Module PV2', 'mdl': Register.PV2_MODEL, 'mf': Register.PV2_MANUFACTURER}, # noqa: E501
|
|
}
|
|
|
|
__comm_type_val_tpl = "{%set com_types = ['n/a','Wi-Fi', 'G4', 'G5', 'GPRS'] %}{{com_types[value_json['Communication_Type']|int(0)]|default(value_json['Communication_Type'])}}" # noqa: E501
|
|
__work_mode_val_tpl = "{%set mode = ['Normal-Mode', 'Aging-Mode', 'ATE-Mode', 'Shielding GFDI', 'DTU-Mode'] %}{{mode[value_json['Work_Mode']|int(0)]|default(value_json['Work_Mode'])}}" # noqa: E501
|
|
__status_type_val_tpl = "{%set inv_status = ['Off-line', 'On-grid', 'Off-grid'] %}{{inv_status[value_json['Inverter_Status']|int(0)]|default(value_json['Inverter_Status'])}}" # noqa: E501
|
|
__mppt1_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv1']['MPPT-Status']|int(0)]|default(value_json['pv1']['MPPT-Status'])}}" # noqa: E501
|
|
__mppt2_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv2']['MPPT-Status']|int(0)]|default(value_json['pv2']['MPPT-Status'])}}" # noqa: E501
|
|
__out_status_type_val_tpl = "{%set out_status = ['Standby', 'On'] %}{{out_status[value_json['out']['Out_Status']|int(0)]|default(value_json['out']['Out_Status'])}}" # noqa: E501
|
|
__rated_power_val_tpl = "{% if 'Rated_Power' in value_json and value_json['Rated_Power'] != None %}{{value_json['Rated_Power']|string() +' W'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
|
|
__designed_power_val_tpl = '''
|
|
{% if 'Max_Designed_Power' in value_json and
|
|
value_json['Max_Designed_Power'] != None %}
|
|
{% if value_json['Max_Designed_Power'] | int(0xffff) < 0x8000 %}
|
|
{{value_json['Max_Designed_Power']|string() +' W'}}
|
|
{% else %}
|
|
n/a
|
|
{% endif %}
|
|
{% else %}
|
|
{{ this.state }}
|
|
{% endif %}
|
|
'''
|
|
__inv_alarm_val_tpl = '''
|
|
{% if 'Inverter_Alarm' in value_json and
|
|
value_json['Inverter_Alarm'] != None %}
|
|
{% set val_int = value_json['Inverter_Alarm'] | int %}
|
|
{% if val_int == 0 %}
|
|
{% set result = 'noAlarm'%}
|
|
{%else%}
|
|
{% set result = '' %}
|
|
{% if val_int | bitwise_and(1)%}
|
|
{% set result = result + 'HBridgeFault, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(2)%}
|
|
{% set result = result + 'DriVoltageFault, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(3)%}
|
|
{% set result = result + 'GFDI-Fault, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(4)%}
|
|
{% set result = result + 'OverTemp, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(5)%}
|
|
{% set result = result + 'CommLose, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(6)%}
|
|
{% set result = result + 'Bit6, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(7)%}
|
|
{% set result = result + 'Bit7, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(8)%}
|
|
{% set result = result + 'EEPROM-Fault, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(9)%}
|
|
{% set result = result + 'NoUtility, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(10)%}
|
|
{% set result = result + 'VG_Offset, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(11)%}
|
|
{% set result = result + 'Relais_Open, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(12)%}
|
|
{% set result = result + 'Relais_Short, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(13)%}
|
|
{% set result = result + 'GridVoltOverRating, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(14)%}
|
|
{% set result = result + 'GridVoltUnderRating, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(15)%}
|
|
{% set result = result + 'GridFreqOverRating, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(16)%}
|
|
{% set result = result + 'GridFreqUnderRating, '%}
|
|
{% endif %}
|
|
{% endif %}
|
|
{{ result }}
|
|
{% else %}
|
|
{{ this.state }}
|
|
{% endif %}
|
|
'''
|
|
__inv_fault_val_tpl = '''
|
|
{% if 'Inverter_Fault' in value_json and
|
|
value_json['Inverter_Fault'] != None %}
|
|
{% set val_int = value_json['Inverter_Fault'] | int %}
|
|
{% if val_int == 0 %}
|
|
{% set result = 'noFault'%}
|
|
{%else%}
|
|
{% set result = '' %}
|
|
{% if val_int | bitwise_and(1)%}
|
|
{% set result = result + 'PVOV-Fault (PV OverVolt), '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(2)%}
|
|
{% set result = result + 'PVLV-Fault (PV LowVolt), '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(3)%}
|
|
{% set result = result + 'PV OI-Fault (PV OverCurrent), '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(4)%}
|
|
{% set result = result + 'PV OFV-Fault, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(5)%}
|
|
{% set result = result + 'DC ShortCircuitFault, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(6)%}{% set result = result + 'Bit6, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(7)%}{% set result = result + 'Bit7, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(8)%}{% set result = result + 'Bit8, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(9)%}{% set result = result + 'Bit9, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(10)%}{% set result = result + 'Bit10, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(11)%}{% set result = result + 'Bit11, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(12)%}{% set result = result + 'Bit12, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(13)%}{% set result = result + 'Bit13, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(14)%}{% set result = result + 'Bit14, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(15)%}{% set result = result + 'Bit15, '%}
|
|
{% endif %}
|
|
{% if val_int | bitwise_and(16)%}{% set result = result + 'Bit16, '%}
|
|
{% endif %}
|
|
{% endif %}
|
|
{{ result }}
|
|
{% else %}
|
|
{{ this.state }}
|
|
{% endif %}
|
|
'''
|
|
|
|
__input_coef_val_tpl = "{% if 'Output_Coefficient' in value_json and value_json['Input_Coefficient'] != None %}{{value_json['Input_Coefficient']|string() +' %'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
|
|
__output_coef_val_tpl = "{% if 'Output_Coefficient' in value_json and value_json['Output_Coefficient'] != None %}{{value_json['Output_Coefficient']|string() +' %'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
|
|
|
|
__info_defs = {
|
|
# collector values used for device registration:
|
|
Register.COLLECTOR_FW_VERSION: {'name': ['collector', 'Collector_Fw_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.CHIP_TYPE: {'name': ['collector', 'Chip_Type'], 'singleton': False, 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.CHIP_MODEL: {'name': ['collector', 'Chip_Model'], 'singleton': False, 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.TRACE_URL: {'name': ['collector', 'Trace_URL'], 'singleton': False, 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.LOGGER_URL: {'name': ['collector', 'Logger_URL'], 'singleton': False, 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.MAC_ADDR: {'name': ['collector', 'MAC-Addr'], 'singleton': False, 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.COLLECTOR_SNR: {'name': ['collector', 'Serial_Number'], 'singleton': False, 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
|
|
|
|
# inverter values used for device registration:
|
|
Register.PRODUCT_NAME: {'name': ['inverter', 'Product_Name'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.MANUFACTURER: {'name': ['inverter', 'Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.VERSION: {'name': ['inverter', 'Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.SERIAL_NUMBER: {'name': ['inverter', 'Serial_Number'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.EQUIPMENT_MODEL: {'name': ['inverter', 'Equipment_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.NO_INPUTS: {'name': ['inverter', 'No_Inputs'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.MAX_DESIGNED_POWER: {'name': ['inverter', 'Max_Designed_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'designed_power_', 'val_tpl': __designed_power_val_tpl, 'name': 'Max Designed Power', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.RATED_POWER: {'name': ['inverter', 'Rated_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'rated_power_', 'val_tpl': __rated_power_val_tpl, 'name': 'Rated Power', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.WORK_MODE: {'name': ['inverter', 'Work_Mode'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'work_mode_', 'name': 'Work Mode', 'val_tpl': __work_mode_val_tpl, 'icon': POWER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INPUT_COEFFICIENT: {'name': ['inverter', 'Input_Coefficient'], 'level': logging.DEBUG, 'unit': '%', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'input_coef_', 'val_tpl': __input_coef_val_tpl, 'name': 'Input Coefficient', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.OUTPUT_COEFFICIENT: {'name': ['inverter', 'Output_Coefficient'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'output_coef_', 'val_tpl': __output_coef_val_tpl, 'name': 'Output Coefficient', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV1_MANUFACTURER: {'name': ['inverter', 'PV1_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV1_MODEL: {'name': ['inverter', 'PV1_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV2_MANUFACTURER: {'name': ['inverter', 'PV2_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV2_MODEL: {'name': ['inverter', 'PV2_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV3_MANUFACTURER: {'name': ['inverter', 'PV3_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV3_MODEL: {'name': ['inverter', 'PV3_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV4_MANUFACTURER: {'name': ['inverter', 'PV4_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV4_MODEL: {'name': ['inverter', 'PV4_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV5_MANUFACTURER: {'name': ['inverter', 'PV5_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV5_MODEL: {'name': ['inverter', 'PV5_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV6_MANUFACTURER: {'name': ['inverter', 'PV6_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PV6_MODEL: {'name': ['inverter', 'PV6_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.BOOT_STATUS: {'name': ['inverter', 'BOOT_STATUS'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.DSP_STATUS: {'name': ['inverter', 'DSP_STATUS'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
# proxy:
|
|
Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': FMT_INT, 'name': 'Active Inverter Connections', 'icon': COUNTER}}, # noqa: E501
|
|
Register.CLOUD_CONN_CNT: {'name': ['proxy', 'Cloud_Conn_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'cloud_conn_count_', 'fmt': FMT_INT, 'name': 'Active Cloud Connections', 'icon': COUNTER}}, # noqa: E501
|
|
Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': FMT_INT, 'name': 'Unknown Serial No', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.UNKNOWN_MSG: {'name': ['proxy', 'Unknown_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_msg_', 'fmt': FMT_INT, 'name': 'Unknown Msg Type', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INVALID_DATA_TYPE: {'name': ['proxy', 'Invalid_Data_Type'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_data_type_', 'fmt': FMT_INT, 'name': 'Invalid Data Type', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INTERNAL_ERROR: {'name': ['proxy', 'Internal_Error'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'intern_err_', 'fmt': FMT_INT, 'name': 'Internal Error', 'icon': COUNTER, 'ent_cat': 'diagnostic', 'en': False}}, # noqa: E501
|
|
Register.UNKNOWN_CTRL: {'name': ['proxy', 'Unknown_Ctrl'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_ctrl_', 'fmt': FMT_INT, 'name': 'Unknown Control Type', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.OTA_START_MSG: {'name': ['proxy', 'OTA_Start_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'ota_start_cmd_', 'fmt': FMT_INT, 'name': 'OTA Start Cmd', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.SW_EXCEPTION: {'name': ['proxy', 'SW_Exception'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'sw_exception_', 'fmt': FMT_INT, 'name': 'Internal SW Exception', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.INVALID_MSG_FMT: {'name': ['proxy', 'Invalid_Msg_Format'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_msg_fmt_', 'fmt': FMT_INT, 'name': 'Invalid Message Format', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.AT_COMMAND: {'name': ['proxy', 'AT_Command'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'at_cmd_', 'fmt': FMT_INT, 'name': 'AT Command', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.AT_COMMAND_BLOCKED: {'name': ['proxy', 'AT_Command_Blocked'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'at_cmd_blocked_', 'fmt': FMT_INT, 'name': 'AT Command Blocked', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.MODBUS_COMMAND: {'name': ['proxy', 'Modbus_Command'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'modbus_cmd_', 'fmt': FMT_INT, 'name': 'Modbus Command', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':FMT_FLOAT,'name': 'Grid Voltage'}}, # noqa: E501
|
|
|
|
# events
|
|
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
|
|
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
|
|
Register.EVENT_BF1: {'name': ['events', 'Inverter_Bitfield_1'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.EVENT_BF2: {'name': ['events', 'Inverter_bitfield_2'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
# Register.EVENT_409: {'name': ['events', '409_No_Utility'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
# Register.EVENT_415: {'name': ['events', '415_GridFreqOverRating'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
# grid measures:
|
|
Register.TS_GRID: {'name': ['grid', 'Timestamp'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.GRID_VOLTAGE: {'name': ['grid', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'inverter', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'fmt': FMT_FLOAT, 'name': 'Grid Voltage', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.GRID_CURRENT: {'name': ['grid', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'inverter', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'fmt': FMT_FLOAT, 'name': 'Grid Current', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.GRID_FREQUENCY: {'name': ['grid', 'Frequency'], 'level': logging.DEBUG, 'unit': 'Hz', 'ha': {'dev': 'inverter', 'dev_cla': 'frequency', 'stat_cla': 'measurement', 'id': 'out_freq_', 'fmt': FMT_FLOAT, 'name': 'Grid Frequency', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.OUTPUT_POWER: {'name': ['grid', 'Output_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'fmt': FMT_FLOAT, 'name': 'Power'}}, # noqa: E501
|
|
Register.INVERTER_TEMP: {'name': ['env', 'Inverter_Temp'], 'level': logging.DEBUG, 'unit': '°C', 'ha': {'dev': 'inverter', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501
|
|
Register.INVERTER_STATUS: {'name': ['env', 'Inverter_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_status_', 'name': 'Inverter Status', 'val_tpl': __status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
|
Register.DETECT_STATUS_1: {'name': ['env', 'Detect_Status_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.DETECT_STATUS_2: {'name': ['env', 'Detect_Status_2'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
# input measures:
|
|
Register.TS_INPUT: {'name': ['input', 'Timestamp'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.PV1_VOLTAGE: {'name': ['input', 'pv1', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV1_CURRENT: {'name': ['input', 'pv1', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV1_POWER: {'name': ['input', 'pv1', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'input_pv1', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv1_', 'val_tpl': "{{ (value_json['pv1']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV2_VOLTAGE: {'name': ['input', 'pv2', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV2_CURRENT: {'name': ['input', 'pv2', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV2_POWER: {'name': ['input', 'pv2', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'input_pv2', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv2_', 'val_tpl': "{{ (value_json['pv2']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV3_VOLTAGE: {'name': ['input', 'pv3', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv3', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv3_', 'val_tpl': "{{ (value_json['pv3']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV3_CURRENT: {'name': ['input', 'pv3', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv3', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv3_', 'val_tpl': "{{ (value_json['pv3']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV3_POWER: {'name': ['input', 'pv3', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'input_pv3', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv3_', 'val_tpl': "{{ (value_json['pv3']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV4_VOLTAGE: {'name': ['input', 'pv4', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv4', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv4_', 'val_tpl': "{{ (value_json['pv4']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV4_CURRENT: {'name': ['input', 'pv4', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv4', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv4_', 'val_tpl': "{{ (value_json['pv4']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV4_POWER: {'name': ['input', 'pv4', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'input_pv4', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv4_', 'val_tpl': "{{ (value_json['pv4']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV5_VOLTAGE: {'name': ['input', 'pv5', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv5', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv5_', 'val_tpl': "{{ (value_json['pv5']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV5_CURRENT: {'name': ['input', 'pv5', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv5', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv5_', 'val_tpl': "{{ (value_json['pv5']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV5_POWER: {'name': ['input', 'pv5', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'input_pv5', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv5_', 'val_tpl': "{{ (value_json['pv5']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV6_VOLTAGE: {'name': ['input', 'pv6', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha': {'dev': 'input_pv6', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv6_', 'val_tpl': "{{ (value_json['pv6']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV6_CURRENT: {'name': ['input', 'pv6', 'Current'], 'level': logging.DEBUG, 'unit': 'A', 'ha': {'dev': 'input_pv6', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv6_', 'val_tpl': "{{ (value_json['pv6']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.PV6_POWER: {'name': ['input', 'pv6', 'Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'input_pv6', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_pv6_', 'val_tpl': "{{ (value_json['pv6']['Power'] | float)}}"}}, # noqa: E501
|
|
Register.PV1_DAILY_GENERATION: {'name': ['input', 'pv1', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv1', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv1_', 'name': DAILY_GEN, 'val_tpl': "{{ (value_json['pv1']['Daily_Generation'] | float)}}", 'icon': SOLAR_POWER_VAR, 'must_incr': True}}, # noqa: E501
|
|
Register.PV1_TOTAL_GENERATION: {'name': ['input', 'pv1', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv1', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv1_', 'name': TOTAL_GEN, 'val_tpl': "{{ (value_json['pv1']['Total_Generation'] | float)}}", 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
|
Register.PV2_DAILY_GENERATION: {'name': ['input', 'pv2', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv2', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv2_', 'name': DAILY_GEN, 'val_tpl': "{{ (value_json['pv2']['Daily_Generation'] | float)}}", 'icon': SOLAR_POWER_VAR, 'must_incr': True}}, # noqa: E501
|
|
Register.PV2_TOTAL_GENERATION: {'name': ['input', 'pv2', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv2', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv2_', 'name': TOTAL_GEN, 'val_tpl': "{{ (value_json['pv2']['Total_Generation'] | float)}}", 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
|
Register.PV3_DAILY_GENERATION: {'name': ['input', 'pv3', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv3', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv3_', 'name': DAILY_GEN, 'val_tpl': "{{ (value_json['pv3']['Daily_Generation'] | float)}}", 'icon': SOLAR_POWER_VAR, 'must_incr': True}}, # noqa: E501
|
|
Register.PV3_TOTAL_GENERATION: {'name': ['input', 'pv3', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv3', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv3_', 'name': TOTAL_GEN, 'val_tpl': "{{ (value_json['pv3']['Total_Generation'] | float)}}", 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
|
Register.PV4_DAILY_GENERATION: {'name': ['input', 'pv4', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv4', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv4_', 'name': DAILY_GEN, 'val_tpl': "{{ (value_json['pv4']['Daily_Generation'] | float)}}", 'icon': SOLAR_POWER_VAR, 'must_incr': True}}, # noqa: E501
|
|
Register.PV4_TOTAL_GENERATION: {'name': ['input', 'pv4', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv4', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv4_', 'name': TOTAL_GEN, 'val_tpl': "{{ (value_json['pv4']['Total_Generation'] | float)}}", 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
|
Register.PV5_DAILY_GENERATION: {'name': ['input', 'pv5', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv5', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv5_', 'name': DAILY_GEN, 'val_tpl': "{{ (value_json['pv5']['Daily_Generation'] | float)}}", 'icon': SOLAR_POWER_VAR, 'must_incr': True}}, # noqa: E501
|
|
Register.PV5_TOTAL_GENERATION: {'name': ['input', 'pv5', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv5', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv5_', 'name': TOTAL_GEN, 'val_tpl': "{{ (value_json['pv5']['Total_Generation'] | float)}}", 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
|
Register.PV6_DAILY_GENERATION: {'name': ['input', 'pv6', 'Daily_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv6', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_pv6_', 'name': DAILY_GEN, 'val_tpl': "{{ (value_json['pv6']['Daily_Generation'] | float)}}", 'icon': SOLAR_POWER_VAR, 'must_incr': True}}, # noqa: E501
|
|
Register.PV6_TOTAL_GENERATION: {'name': ['input', 'pv6', 'Total_Generation'], 'level': logging.DEBUG, 'unit': 'kWh', 'ha': {'dev': 'input_pv6', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_pv6_', 'name': TOTAL_GEN, 'val_tpl': "{{ (value_json['pv6']['Total_Generation'] | float)}}", 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
|
# total:
|
|
Register.TS_TOTAL: {'name': ['total', 'Timestamp'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.DAILY_GENERATION: {'name': ['total', 'Daily_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'inverter', 'dev_cla': 'energy', 'stat_cla': 'total_increasing', 'id': 'daily_gen_', 'fmt': FMT_FLOAT, 'name': DAILY_GEN, 'icon': SOLAR_POWER_VAR, 'must_incr': True}}, # noqa: E501
|
|
Register.TOTAL_GENERATION: {'name': ['total', 'Total_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'inverter', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_', 'fmt': FMT_FLOAT, 'name': TOTAL_GEN, 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
|
|
|
# controller:
|
|
Register.SIGNAL_STRENGTH: {'name': ['controller', 'Signal_Strength'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'signal_', 'fmt': FMT_INT, 'name': 'Signal Strength', 'icon': WIFI}}, # noqa: E501
|
|
Register.POWER_ON_TIME: {'name': ['controller', 'Power_On_Time'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': 'duration', 'stat_cla': 'measurement', 'id': 'power_on_time_', 'fmt': FMT_INT, 'name': 'Power on Time', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.COLLECT_INTERVAL: {'name': ['controller', 'Collect_Interval'], 'level': logging.INFO, 'unit': 'min', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_collect_intval_', 'fmt': '| string + " min"', 'name': 'Data Collect Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.CONNECT_COUNT: {'name': ['controller', 'Connect_Count'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'connect_count_', 'fmt': FMT_INT, 'name': 'Connect Count', 'icon': COUNTER, 'comp': 'sensor', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.COMMUNICATION_TYPE: {'name': ['controller', 'Communication_Type'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'comm_type_', 'name': 'Communication Type', 'val_tpl': __comm_type_val_tpl, 'comp': 'sensor', 'icon': WIFI}}, # noqa: E501
|
|
Register.DATA_UP_INTERVAL: {'name': ['controller', 'Data_Up_Interval'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_up_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Data Up Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.HEARTBEAT_INTERVAL: {'name': ['controller', 'Heartbeat_Interval'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'heartbeat_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Heartbeat Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.IP_ADDRESS: {'name': ['controller', 'IP_Address'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'ip_address_', 'fmt': '| string', 'name': 'IP Address', 'icon': WIFI, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.POLLING_INTERVAL: {'name': ['controller', 'Polling_Interval'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'polling_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Polling Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.SENSOR_LIST: {'name': ['controller', 'Sensor_List'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.SSID: {'name': ['controller', 'WiFi_SSID'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
Register.OUTPUT_SHUTDOWN: {'name': ['other', 'Output_Shutdown'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.RATED_LEVEL: {'name': ['other', 'Rated_Level'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.GRID_VOLT_CAL_COEF: {'name': ['other', 'Grid_Volt_Cal_Coef'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
Register.PROD_COMPL_TYPE: {'name': ['other', 'Prod_Compliance_Type'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
# Batterie DC-1000: Electricity Genration
|
|
Register.BATT_STATUS_1: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
|
Register.BATT_PV1_VOLT: {'name': ['batterie', 'pv1', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_PV1_CUR: {'name': ['batterie', 'pv1', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_STATUS_2: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
|
Register.BATT_PV2_VOLT: {'name': ['batterie', 'pv2', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_PV2_CUR: {'name': ['batterie', 'pv2', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_PV_PWR: {'name': ['batterie', 'PV_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'pv_power_', 'fmt': FMT_INT, 'name': 'PV Power'}}, # noqa: E501
|
|
Register.BATT_OUT_STATUS: {'name': ['batterie', 'out', 'Out_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'out_status_', 'name': 'Output Status', 'val_tpl': __out_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
|
|
Register.BATT_OUT_VOLT: {'name': ['batterie', 'out', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'val_tpl': "{{ (value_json['out']['Voltage'] | float)}}", 'name': 'Output Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_OUT_CUR: {'name': ['batterie', 'out', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'val_tpl': "{{ (value_json['out']['Current'] | float)}}", 'name': 'Output Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_OUT_PWR: {'name': ['batterie', 'out', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'val_tpl': "{{ (value_json['out']['Power'] | int)}}", 'name': 'Supply Power'}}, # noqa: E501
|
|
|
|
# Batterie DC-1000: Cell Package
|
|
Register.BATT_CELL1_VOLT: {'name': ['batterie', 'cell', 'Volt1'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell1_', 'val_tpl': "{{ (value_json['cell']['Volt1'] | float)}}", 'name': 'Cell-01 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL3_VOLT: {'name': ['batterie', 'cell', 'Volt3'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell3_', 'val_tpl': "{{ (value_json['cell']['Volt2'] | float)}}", 'name': 'Cell-03 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL4_VOLT: {'name': ['batterie', 'cell', 'Volt4'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell4_', 'val_tpl': "{{ (value_json['cell']['Volt3'] | float)}}", 'name': 'Cell-04 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL2_VOLT: {'name': ['batterie', 'cell', 'Volt2'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell2_', 'val_tpl': "{{ (value_json['cell']['Volt4'] | float)}}", 'name': 'Cell-02 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL5_VOLT: {'name': ['batterie', 'cell', 'Volt5'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell5_', 'val_tpl': "{{ (value_json['cell']['Volt5'] | float)}}", 'name': 'Cell-05 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL6_VOLT: {'name': ['batterie', 'cell', 'Volt6'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell6_', 'val_tpl': "{{ (value_json['cell']['Volt6'] | float)}}", 'name': 'Cell-06 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL7_VOLT: {'name': ['batterie', 'cell', 'Volt7'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell7_', 'val_tpl': "{{ (value_json['cell']['Volt7'] | float)}}", 'name': 'Cell-07 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL8_VOLT: {'name': ['batterie', 'cell', 'Volt8'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell8_', 'val_tpl': "{{ (value_json['cell']['Volt8'] | float)}}", 'name': 'Cell-08 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL9_VOLT: {'name': ['batterie', 'cell', 'Volt9'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell9_', 'val_tpl': "{{ (value_json['cell']['Volt9'] | float)}}", 'name': 'Cell-09 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL10_VOLT: {'name': ['batterie', 'cell', 'Volt10'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell10_', 'val_tpl': "{{ (value_json['cell']['Volt10'] | float)}}", 'name': 'Cell-10 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL11_VOLT: {'name': ['batterie', 'cell', 'Volt11'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell11_', 'val_tpl': "{{ (value_json['cell']['Volt11'] | float)}}", 'name': 'Cell-11 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL12_VOLT: {'name': ['batterie', 'cell', 'Volt12'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell12_', 'val_tpl': "{{ (value_json['cell']['Volt12'] | float)}}", 'name': 'Cell-12 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL13_VOLT: {'name': ['batterie', 'cell', 'Volt13'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell13_', 'val_tpl': "{{ (value_json['cell']['Volt13'] | float)}}", 'name': 'Cell-13 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL14_VOLT: {'name': ['batterie', 'cell', 'Volt14'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell14_', 'val_tpl': "{{ (value_json['cell']['Volt14'] | float)}}", 'name': 'Cell-14 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL15_VOLT: {'name': ['batterie', 'cell', 'Volt15'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell15_', 'val_tpl': "{{ (value_json['cell']['Volt15'] | float)}}", 'name': 'Cell-15 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CELL16_VOLT: {'name': ['batterie', 'cell', 'Volt16'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell16_', 'val_tpl': "{{ (value_json['cell']['Volt16'] | float)}}", 'name': 'Cell-16 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
|
|
# Batterie DC-1000: Batterie Pack
|
|
Register.BATT_VOLT: {'name': ['batterie', 'batt', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_bat_', 'val_tpl': "{{ (value_json['batt']['Voltage'] | float)}}", 'name': 'Batterie Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_CUR: {'name': ['batterie', 'batt', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_bat_', 'val_tpl': "{{ (value_json['batt']['Current'] | float)}}", 'name': 'Batterie Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_PWR: {'name': ['batterie', 'batt', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_', 'val_tpl': "{{ (value_json['batt']['Power'] | int)}}", 'name': 'Batterie Power'}}, # noqa: E501
|
|
Register.BATT_SOC: {'name': ['batterie', 'batt', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'val_tpl': "{{ (value_json['batt']['SOC'] | float)}}", 'name': 'State of Charge (SOC)', 'icon': 'mdi:battery-90'}}, # noqa: E501
|
|
Register.BATT_TOTAL_CHARG: {'name': ['batterie', 'batt', 'Total_Charging'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'batterie', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_charg_', 'val_tpl': "{{ (value_json['batt']['Total_Charging'] | float)}}", 'name': TOTAL_CHARG, 'icon': 'mdi:battery-charging', 'must_incr': True}}, # noqa: E501
|
|
|
|
Register.BATT_TEMP_1: {'name': ['batterie', 'cell', 'Temp_1'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_1_', 'val_tpl': "{{ (value_json['cell']['Temp_1'] | int)}}", 'name': 'Cell Temp-1', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_TEMP_2: {'name': ['batterie', 'cell', 'Temp_2'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_2_', 'val_tpl': "{{ (value_json['cell']['Temp_2'] | int)}}", 'name': 'Cell Temp-2', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_TEMP_3: {'name': ['batterie', 'cell', 'Temp_3'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_3_', 'val_tpl': "{{ (value_json['cell']['Temp_3'] | int)}}", 'name': 'Cell Temp-3', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_TEMP_4: {'name': ['batterie', 'Controller_Temp'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_4_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501
|
|
Register.BATT_74: {'name': ['batterie', 'Reg_74'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_74_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.BATT_HW_VERS: {'name': ['batterie', 'Hardware_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
Register.BATT_SW_VERS: {'name': ['batterie', 'Software_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
|
|
Register.TEST_VAL_0: {'name': ['input', 'Val_0'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_0_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_1: {'name': ['input', 'Val_1'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_1_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_2: {'name': ['input', 'Val_2'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_2_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_3: {'name': ['input', 'Val_3'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_3_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_4: {'name': ['input', 'Val_4'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_4_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_5: {'name': ['input', 'Val_5'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_5_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_6: {'name': ['input', 'Val_6'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_6_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_7: {'name': ['input', 'Val_7'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_7_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_8: {'name': ['input', 'Val_8'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_8_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_9: {'name': ['input', 'Val_9'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_9_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_10: {'name': ['input', 'Val_10'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_10_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_11: {'name': ['input', 'Val_11'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_11_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_12: {'name': ['input', 'Val_12'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_12_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_13: {'name': ['input', 'Val_13'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_13_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_14: {'name': ['input', 'Val_14'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_14_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_15: {'name': ['input', 'Val_15'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_15_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_16: {'name': ['input', 'Val_16'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_16_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_17: {'name': ['input', 'Val_17'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_17_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_18: {'name': ['input', 'Val_18'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_18_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_19: {'name': ['input', 'Val_19'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_19_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_20: {'name': ['input', 'Val_20'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_20_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_21: {'name': ['input', 'Val_21'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_21_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_22: {'name': ['input', 'Val_22'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_22_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_23: {'name': ['input', 'Val_23'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_23_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_24: {'name': ['input', 'Val_24'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_24_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_25: {'name': ['input', 'Val_25'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_25_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_26: {'name': ['input', 'Val_26'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_26_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_27: {'name': ['input', 'Val_27'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_27_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_28: {'name': ['input', 'Val_28'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_28_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_29: {'name': ['input', 'Val_29'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_29_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_30: {'name': ['input', 'Val_30'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_30_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_31: {'name': ['input', 'Val_31'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_31_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_VAL_32: {'name': ['input', 'Val_32'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'val_32_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
|
|
Register.TEST_IVAL_1: {'name': ['input', 'iVal_1'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_1_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_2: {'name': ['input', 'iVal_2'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_2_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_3: {'name': ['input', 'iVal_3'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_3_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_4: {'name': ['input', 'iVal_4'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_4_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_5: {'name': ['input', 'iVal_5'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_5_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_6: {'name': ['input', 'iVal_6'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_6_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_7: {'name': ['input', 'iVal_7'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_7_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_8: {'name': ['input', 'iVal_8'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_8_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_9: {'name': ['input', 'iVal_9'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_9_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_10: {'name': ['input', 'iVal_10'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_10_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_11: {'name': ['input', 'iVal_11'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_11_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
Register.TEST_IVAL_12: {'name': ['input', 'iVal_12'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'ival_12_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
}
|
|
|
|
@property
|
|
def info_devs(self) -> dict:
|
|
return self.__info_devs
|
|
|
|
@property
|
|
def info_defs(self) -> dict:
|
|
return self.__info_defs
|
|
|
|
def dev_value(self, idx: str | int) -> str | int | float | dict | None:
|
|
'''returns the stored device value from our database
|
|
|
|
idx:int ==> lookup the value in the database and return it as str,
|
|
int or float. If the value is not available return 'None'
|
|
idx:str ==> returns the string as a fixed value without a
|
|
database lookup
|
|
'''
|
|
if type(idx) is str:
|
|
return idx # return idx as a fixed value
|
|
elif idx in self.info_defs:
|
|
row = self.info_defs[idx]
|
|
if 'singleton' in row and row['singleton']:
|
|
db_dict = self.stat
|
|
else:
|
|
db_dict = self.db
|
|
|
|
keys = row['name']
|
|
|
|
for key in keys:
|
|
if key not in db_dict:
|
|
return None # value not found in the database
|
|
db_dict = db_dict[key]
|
|
return db_dict # value of the reqeusted entry
|
|
|
|
return None # unknwon idx, not in info_defs
|
|
|
|
@classmethod
|
|
def inc_counter(cls, counter: str) -> None:
|
|
'''inc proxy statistic counter'''
|
|
db_dict = cls.stat['proxy']
|
|
db_dict[counter] += 1
|
|
cls.new_stat_data['proxy'] = True
|
|
|
|
@classmethod
|
|
def dec_counter(cls, counter: str) -> None:
|
|
'''dec proxy statistic counter'''
|
|
db_dict = cls.stat['proxy']
|
|
db_dict[counter] -= 1
|
|
cls.new_stat_data['proxy'] = True
|
|
|
|
def ha_proxy_confs(self, ha_prfx: str, node_id: str, snr: str) \
|
|
-> Generator[tuple[str, str, str, str], None, None]:
|
|
'''Generator function yields json register struct for home-assistant
|
|
auto configuration and the unique entity string, for all proxy
|
|
registers
|
|
|
|
arguments:
|
|
ha_prfx:str ==> MQTT prefix for the home assistant 'stat_t string
|
|
node_id:str ==> node id of the inverter, used to build unique entity
|
|
snr:str ==> serial number of the inverter, used to build unique
|
|
entity strings
|
|
'''
|
|
# iterate over RegisterMap.map and get the register values for entries
|
|
# with Singleton=True, which means that this is a proxy register
|
|
for reg in self.info_defs.keys():
|
|
res = self.ha_conf(reg, ha_prfx, node_id, snr, True) # noqa: E501
|
|
if res:
|
|
yield res
|
|
|
|
def ha_conf(self, key, ha_prfx, node_id, snr, singleton: bool,
|
|
sug_area: str = '') -> tuple[str, str, str, str] | None:
|
|
'''Method to build json register struct for home-assistant
|
|
auto configuration and the unique entity string, for all proxy
|
|
registers
|
|
|
|
arguments:
|
|
key ==> index of info_defs dict which reference the topic
|
|
ha_prfx:str ==> MQTT prefix for the home assistant 'stat_t string
|
|
node_id:str ==> node id of the inverter, used to build unique entity
|
|
snr:str ==> serial number of the inverter, used to build unique
|
|
entity strings
|
|
singleton ==> bool to allow/disaalow proxy topics which are common
|
|
for all invters
|
|
sug_area ==> area name for home assistant
|
|
'''
|
|
if key not in self.info_defs:
|
|
return None
|
|
row = self.info_defs[key]
|
|
|
|
if 'singleton' in row:
|
|
if singleton != row['singleton']:
|
|
return None
|
|
elif singleton:
|
|
return None
|
|
|
|
# check if we have details for home assistant
|
|
if 'ha' in row:
|
|
return self.__ha_conf(row, key, ha_prfx, node_id, snr, sug_area)
|
|
return None
|
|
|
|
def __ha_conf(self, row, key, ha_prfx, node_id, snr,
|
|
sug_area: str) -> tuple[str, str, str, str] | None:
|
|
ha = row['ha']
|
|
if 'comp' in ha:
|
|
component = ha['comp']
|
|
else:
|
|
component = 'sensor'
|
|
attr = self.__build_attr(row, key, ha_prfx, node_id, snr)
|
|
if 'dev' in ha:
|
|
device = self.info_devs[ha['dev']]
|
|
if 'dep' in device and self.ignore_this_device(device['dep']): # noqa: E501
|
|
return None
|
|
attr['dev'] = self.__build_dev(device, key, ha, snr,
|
|
sug_area)
|
|
attr['o'] = self.__build_origin()
|
|
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.info_defs: the row for {key} "
|
|
"missing 'dev' value for ha register")
|
|
return json.dumps(attr), component, node_id, attr['uniq_id']
|
|
|
|
def __build_attr(self, row, key, ha_prfx, node_id, snr):
|
|
attr = {}
|
|
ha = row['ha']
|
|
if 'name' in ha:
|
|
attr['name'] = ha['name']
|
|
else:
|
|
attr['name'] = row['name'][-1]
|
|
prfx = ha_prfx + node_id
|
|
attr['stat_t'] = prfx + row['name'][0]
|
|
attr['dev_cla'] = ha['dev_cla']
|
|
attr['stat_cla'] = ha['stat_cla']
|
|
attr['uniq_id'] = ha['id']+snr
|
|
if 'val_tpl' in ha:
|
|
attr['val_tpl'] = ha['val_tpl']
|
|
elif 'fmt' in ha:
|
|
attr['val_tpl'] = '{{value_json' + f"['{row['name'][-1]}'] {ha['fmt']}" + '}}' # eg. 'val_tpl': "{{ value_json['Output_Power']|float }} # noqa: E501
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.info_defs: the row for {key} do"
|
|
" not have a 'val_tpl' nor a 'fmt' value")
|
|
# add unit_of_meas only, if status_class isn't none. If
|
|
# status_cla is None we want a number format and not line
|
|
# graph in home assistant. A unit will change the number
|
|
# format to a line graph
|
|
if 'unit' in row and attr['stat_cla'] is not None:
|
|
attr['unit_of_meas'] = row['unit'] # 'unit_of_meas'
|
|
if 'icon' in ha:
|
|
attr['ic'] = ha['icon'] # icon for the entity
|
|
if 'nat_prc' in ha: # pragma: no cover
|
|
attr['sug_dsp_prc'] = ha['nat_prc'] # precison of floats
|
|
if 'ent_cat' in ha:
|
|
attr['ent_cat'] = ha['ent_cat'] # diagnostic, config
|
|
# enabled_by_default is deactivated, since it avoid the via
|
|
# setup of the devices. It seems, that there is a bug in home
|
|
# assistant. tested with 'Home Assistant 2023.10.4'
|
|
# if 'en' in ha: # enabled_by_default
|
|
# attr['en'] = ha['en']
|
|
return attr
|
|
|
|
def __build_dev(self, device, key, ha, snr, sug_area):
|
|
dev = {}
|
|
singleton = 'singleton' in device and device['singleton']
|
|
# the same name for 'name' and 'suggested area', so we get
|
|
# dedicated devices in home assistant with short value
|
|
# name and headline
|
|
if (sug_area == '' or singleton):
|
|
dev['name'] = device['name']
|
|
dev['sa'] = device['name']
|
|
else:
|
|
dev['name'] = device['name']+' - '+sug_area
|
|
dev['sa'] = device['name']+' - '+sug_area
|
|
self.__add_via_dev(dev, device, key, snr)
|
|
for key in ('mdl', 'mf', 'sw', 'hw', 'sn'): # add optional
|
|
# values fpr 'modell', 'manufacturer', 'sw version' and
|
|
# 'hw version'
|
|
if key in device:
|
|
data = self.dev_value(device[key])
|
|
if data is not None:
|
|
dev[key] = data
|
|
if singleton:
|
|
dev['ids'] = [f"{ha['dev']}"]
|
|
else:
|
|
dev['ids'] = [f"{ha['dev']}_{snr}"]
|
|
self.__add_connection(dev, device)
|
|
return dev
|
|
|
|
def __add_connection(self, dev, device):
|
|
if 'mac' in device:
|
|
mac_str = self.dev_value(device['mac'])
|
|
if mac_str is not None:
|
|
if 12 == len(mac_str):
|
|
mac_str = ':'.join(mac_str[i:i+2] for i in range(0, 12, 2))
|
|
dev['cns'] = [["mac", f"{mac_str}"]]
|
|
|
|
def __add_via_dev(self, dev, device, key, snr):
|
|
if 'via' in device: # add the link to the parent device
|
|
via = device['via']
|
|
if via in self.info_devs:
|
|
via_dev = self.info_devs[via]
|
|
if 'singleton' in via_dev and via_dev['singleton']:
|
|
dev['via_device'] = via
|
|
else:
|
|
dev['via_device'] = f"{via}_{snr}"
|
|
else:
|
|
self.inc_counter('Internal_Error')
|
|
logging.error(f"Infos.info_defs: the row for "
|
|
f"{key} has an invalid via value: "
|
|
f"{via}")
|
|
|
|
def __build_origin(self):
|
|
origin = {}
|
|
origin['name'] = self.app_name
|
|
origin['sw'] = self.version
|
|
return origin
|
|
|
|
def ha_remove(self, key, node_id, snr) -> tuple[str, str, str, str] | None:
|
|
'''Method to build json unregister struct for home-assistant
|
|
to remove topics per auto configuration. Only for inverer topics.
|
|
|
|
arguments:
|
|
key ==> index of info_defs dict which reference the topic
|
|
node_id:str ==> node id of the inverter, used to build unique entity
|
|
snr:str ==> serial number of the inverter, used to build unique
|
|
entity strings
|
|
|
|
hint:
|
|
the returned tuple must have the same format as self.ha_conf()
|
|
'''
|
|
if key not in self.info_defs:
|
|
return None
|
|
row = self.info_defs[key]
|
|
|
|
if 'singleton' in row and row['singleton']:
|
|
return None
|
|
|
|
# check if we have details for home assistant
|
|
if 'ha' in row:
|
|
ha = row['ha']
|
|
if 'comp' in ha:
|
|
component = ha['comp']
|
|
else:
|
|
component = 'sensor'
|
|
attr = {}
|
|
uniq_id = ha['id']+snr
|
|
|
|
return json.dumps(attr), component, node_id, uniq_id
|
|
return None
|
|
|
|
def _key_obj(self, id: Register) -> tuple:
|
|
d = self.info_defs.get(id, {'name': None, 'level': logging.DEBUG,
|
|
'unit': ''})
|
|
if 'ha' in d and 'must_incr' in d['ha']:
|
|
must_incr = d['ha']['must_incr']
|
|
else:
|
|
must_incr = False
|
|
|
|
return d['name'], d['level'], d['unit'], must_incr
|
|
|
|
def update_db(self, keys: list, must_incr: bool, result):
|
|
name = ''
|
|
db_dict = self.db
|
|
for key in keys[:-1]:
|
|
if key not in db_dict:
|
|
db_dict[key] = {}
|
|
db_dict = db_dict[key]
|
|
name += key + '.'
|
|
if keys[-1] not in db_dict:
|
|
update = (not must_incr or result > 0)
|
|
else:
|
|
if must_incr:
|
|
update = db_dict[keys[-1]] < result
|
|
else:
|
|
update = db_dict[keys[-1]] != result
|
|
if update:
|
|
db_dict[keys[-1]] = result
|
|
name += keys[-1]
|
|
return name, update
|
|
|
|
def set_db_def_value(self, id: Register, value) -> None:
|
|
'''set default value'''
|
|
row = self.info_defs[id]
|
|
if isinstance(row, dict):
|
|
keys = row['name']
|
|
self.update_db(keys, False, value)
|
|
|
|
def reg_clr_at_midnight(self, prfx: str,
|
|
check_dependencies: bool = True) -> None:
|
|
'''register all registers for the 'ClrAtMidnight' class and
|
|
check if device of every register is available otherwise ignore
|
|
the register.
|
|
|
|
prfx:str ==> prefix for the home assistant 'stat_t string''
|
|
'''
|
|
for id, row in self.info_defs.items():
|
|
if check_dependencies and 'ha' in row:
|
|
ha = row['ha']
|
|
if 'dev' in ha:
|
|
device = self.info_devs[ha['dev']]
|
|
if 'dep' in device and self.ignore_this_device(device['dep']): # noqa: E501
|
|
continue
|
|
|
|
keys = row['name']
|
|
ClrAtMidnight.add(keys, prfx, id)
|
|
|
|
def get_db_value(self, id: Register, not_found_result: any = None):
|
|
'''get database value'''
|
|
if id not in self.info_defs:
|
|
return not_found_result
|
|
row = self.info_defs[id]
|
|
if isinstance(row, dict):
|
|
keys = row['name']
|
|
elm = self.db
|
|
for key in keys:
|
|
if key not in elm:
|
|
return not_found_result
|
|
elm = elm[key]
|
|
return elm
|
|
return not_found_result
|
|
|
|
def ignore_this_device(self, dep: dict) -> bool:
|
|
'''Checks the equation in the dep(endency) dict
|
|
|
|
returns 'False' only if the equation is valid;
|
|
'True' in any other case'''
|
|
if 'reg' in dep:
|
|
value = self.dev_value(dep['reg'])
|
|
if not value:
|
|
return True
|
|
|
|
if 'gte' in dep:
|
|
return value < dep['gte']
|
|
elif 'less_eq' in dep:
|
|
return value > dep['less_eq']
|
|
return True
|
|
|
|
def set_pv_module_details(self, inv: dict) -> None:
|
|
pvs = {'pv1': {'manufacturer': Register.PV1_MANUFACTURER, 'model': Register.PV1_MODEL}, # noqa: E501
|
|
'pv2': {'manufacturer': Register.PV2_MANUFACTURER, 'model': Register.PV2_MODEL}, # noqa: E501
|
|
'pv3': {'manufacturer': Register.PV3_MANUFACTURER, 'model': Register.PV3_MODEL}, # noqa: E501
|
|
'pv4': {'manufacturer': Register.PV4_MANUFACTURER, 'model': Register.PV4_MODEL}, # noqa: E501
|
|
'pv5': {'manufacturer': Register.PV5_MANUFACTURER, 'model': Register.PV5_MODEL}, # noqa: E501
|
|
'pv6': {'manufacturer': Register.PV6_MANUFACTURER, 'model': Register.PV6_MODEL} # noqa: E501
|
|
}
|
|
|
|
for key, reg in pvs.items():
|
|
if key in inv:
|
|
if 'manufacturer' in inv[key]:
|
|
self.set_db_def_value(reg['manufacturer'],
|
|
inv[key]['manufacturer'])
|
|
if 'type' in inv[key]:
|
|
self.set_db_def_value(reg['model'], inv[key]['type'])
|