@@ -154,7 +154,7 @@ class Register(Enum):
|
|
|
|
|
BATT_OUT_CUR = 1033
|
|
|
|
|
BATT_OUT_STATUS = 1034
|
|
|
|
|
BATT_TEMP_4 = 1035
|
|
|
|
|
BATT_74 = 1036
|
|
|
|
|
BATT_ALARM = 1036
|
|
|
|
|
BATT_HW_VERS = 1037
|
|
|
|
|
BATT_SW_VERS = 1038
|
|
|
|
|
BATT_PV_PWR = 1040
|
|
|
|
|
@@ -326,6 +326,7 @@ class Infos:
|
|
|
|
|
SOLAR_POWER_VAR = 'mdi:solar-power-variant'
|
|
|
|
|
SOLAR_POWER = 'mdi:solar-power'
|
|
|
|
|
WIFI = 'mdi:wifi'
|
|
|
|
|
ALARM_LIGHT = 'mdi:alarm-light'
|
|
|
|
|
UPDATE = 'mdi:update'
|
|
|
|
|
DAILY_GEN = 'Daily Generation'
|
|
|
|
|
TOTAL_GEN = 'Total Generation'
|
|
|
|
|
@@ -403,52 +404,52 @@ class Infos:
|
|
|
|
|
{% set result = 'noAlarm'%}
|
|
|
|
|
{%else%}
|
|
|
|
|
{% set result = '' %}
|
|
|
|
|
{% if val_int | bitwise_and(1)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0001)%}
|
|
|
|
|
{% set result = result + 'HBridgeFault, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(2)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0002)%}
|
|
|
|
|
{% set result = result + 'DriVoltageFault, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(3)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0004)%}
|
|
|
|
|
{% set result = result + 'GFDI-Fault, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(4)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0008)%}
|
|
|
|
|
{% set result = result + 'OverTemp, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(5)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0010)%}
|
|
|
|
|
{% set result = result + 'CommLose, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(6)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0020)%}
|
|
|
|
|
{% set result = result + 'Bit6, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(7)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0040)%}
|
|
|
|
|
{% set result = result + 'Bit7, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(8)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0080)%}
|
|
|
|
|
{% set result = result + 'EEPROM-Fault, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(9)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0100)%}
|
|
|
|
|
{% set result = result + 'NoUtility, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(10)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0200)%}
|
|
|
|
|
{% set result = result + 'VG_Offset, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(11)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0400)%}
|
|
|
|
|
{% set result = result + 'Relais_Open, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(12)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0800)%}
|
|
|
|
|
{% set result = result + 'Relais_Short, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(13)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x1000)%}
|
|
|
|
|
{% set result = result + 'GridVoltOverRating, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(14)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x2000)%}
|
|
|
|
|
{% set result = result + 'GridVoltUnderRating, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(15)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x4000)%}
|
|
|
|
|
{% set result = result + 'GridFreqOverRating, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(16)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x8000)%}
|
|
|
|
|
{% set result = result + 'GridFreqUnderRating, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% endif %}
|
|
|
|
|
@@ -465,42 +466,104 @@ class Infos:
|
|
|
|
|
{% set result = 'noFault'%}
|
|
|
|
|
{%else%}
|
|
|
|
|
{% set result = '' %}
|
|
|
|
|
{% if val_int | bitwise_and(1)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0001)%}
|
|
|
|
|
{% set result = result + 'PVOV-Fault (PV OverVolt), '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(2)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0002)%}
|
|
|
|
|
{% set result = result + 'PVLV-Fault (PV LowVolt), '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(3)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0004)%}
|
|
|
|
|
{% set result = result + 'PV OI-Fault (PV OverCurrent), '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(4)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0008)%}
|
|
|
|
|
{% set result = result + 'PV OFV-Fault, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(5)%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0010)%}
|
|
|
|
|
{% set result = result + 'DC ShortCircuitFault, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(6)%}{% set result = result + 'Bit6, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0020)%}{% set result = result + 'Bit6, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(7)%}{% set result = result + 'Bit7, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0040)%}{% set result = result + 'Bit7, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(8)%}{% set result = result + 'Bit8, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0080)%}{% set result = result + 'Bit8, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(9)%}{% set result = result + 'Bit9, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0100)%}{% set result = result + 'Bit9, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(10)%}{% set result = result + 'Bit10, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0200)%}{% set result = result + 'Bit10, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(11)%}{% set result = result + 'Bit11, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0400)%}{% set result = result + 'Bit11, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(12)%}{% set result = result + 'Bit12, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x0800)%}{% set result = result + 'Bit12, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(13)%}{% set result = result + 'Bit13, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x1000)%}{% set result = result + 'Bit13, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(14)%}{% set result = result + 'Bit14, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x2000)%}{% set result = result + 'Bit14, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(15)%}{% set result = result + 'Bit15, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x4000)%}{% set result = result + 'Bit15, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(16)%}{% set result = result + 'Bit16, '%}
|
|
|
|
|
{% if val_int | bitwise_and(0x8000)%}{% set result = result + 'Bit16, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{{ result }}
|
|
|
|
|
{% else %}
|
|
|
|
|
{{ this.state }}
|
|
|
|
|
{% endif %}
|
|
|
|
|
'''
|
|
|
|
|
__batt_alarm_val_tpl = '''
|
|
|
|
|
{% if 'Batterie_Alarm' in value_json and
|
|
|
|
|
value_json['Batterie_Alarm'] != None %}
|
|
|
|
|
{% set val_int = value_json['Batterie_Alarm'] | int %}
|
|
|
|
|
{% if val_int == 0 %}
|
|
|
|
|
{% set result = 'noAlarm'%}
|
|
|
|
|
{%else%}
|
|
|
|
|
{% set result = '' %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0001)%}
|
|
|
|
|
{% set result = result + 'PV1-OverVoltage, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0002)%}
|
|
|
|
|
{% set result = result + 'PV2-OverVoltage, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0004)%}
|
|
|
|
|
{% set result = result + 'EquipmentOverheating, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0008)%}
|
|
|
|
|
{% set result = result + 'EquipmentLowTemp, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0010)%}
|
|
|
|
|
{% set result = result + 'BMS-CommFailed, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0020)%}
|
|
|
|
|
{% set result = result + 'UnderVoltageProt, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0040)%}
|
|
|
|
|
{% set result = result + 'ChargingHighTemp, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0080)%}
|
|
|
|
|
{% set result = result + 'ChargingLowTemp, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0100)%}
|
|
|
|
|
{% set result = result + 'DischargeHighTemp, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0200)%}
|
|
|
|
|
{% set result = result + 'DischargeLowTemp, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0400)%}
|
|
|
|
|
{% set result = result + 'BatterieOverVoltage, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x0800)%}
|
|
|
|
|
{% set result = result + 'SingleCorePressureDifferenceIsTooLarge, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x1000)%}
|
|
|
|
|
{% set result = result + 'Bit-12, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x2000)%}
|
|
|
|
|
{% set result = result + 'Bit-13, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x4000)%}
|
|
|
|
|
{% set result = result + 'Bit-14, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if val_int | bitwise_and(0x8000)%}
|
|
|
|
|
{% set result = result + 'Bit-15, '%}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{{ result }}
|
|
|
|
|
@@ -566,8 +629,8 @@ class Infos:
|
|
|
|
|
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':FMT_FLOAT,'name': 'Grid Voltage'}}, # noqa: E501
|
|
|
|
|
|
|
|
|
|
# events
|
|
|
|
|
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
|
|
|
|
|
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
|
|
|
|
|
Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
|
|
|
|
|
Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
|
|
|
|
|
Register.EVENT_BF1: {'name': ['events', 'Inverter_Bitfield_1'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
|
|
|
Register.EVENT_BF2: {'name': ['events', 'Inverter_bitfield_2'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
|
|
|
# Register.EVENT_409: {'name': ['events', '409_No_Utility'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
|
|
|
|
@@ -684,7 +747,7 @@ class Infos:
|
|
|
|
|
Register.BATT_TEMP_2: {'name': ['batterie', 'cell', 'Temp_2'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_2_', 'val_tpl': "{{ (value_json['cell']['Temp_2'] | int)}}", 'name': 'Cell Temp-2', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
|
|
|
Register.BATT_TEMP_3: {'name': ['batterie', 'cell', 'Temp_3'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_3_', 'val_tpl': "{{ (value_json['cell']['Temp_3'] | int)}}", 'name': 'Cell Temp-3', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
|
|
|
Register.BATT_TEMP_4: {'name': ['batterie', 'Controller_Temp'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_4_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501
|
|
|
|
|
Register.BATT_74: {'name': ['batterie', 'Reg_74'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_74_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
|
|
|
|
Register.BATT_ALARM: {'name': ['batterie', 'Batterie_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'batt_alarm_', 'name': 'Batterie Alarm', 'val_tpl': __batt_alarm_val_tpl, 'icon': ALARM_LIGHT}}, # noqa: E501
|
|
|
|
|
Register.BATT_HW_VERS: {'name': ['batterie', 'Hardware_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
|
|
|
Register.BATT_SW_VERS: {'name': ['batterie', 'Software_Version'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
|
|
|
|
|
|
|
|
|
|