Commit Graph

36 Commits

Author SHA1 Message Date
Stefan Allius
66657888dd add log_level support for modbus commands 2024-05-28 19:32:20 +02:00
Stefan Allius
de1c48fa62 add keyword for timeout to argument list 2024-05-21 18:58:10 +02:00
Stefan Allius
3ac48dad1f cleanup 2024-05-20 18:33:01 +02:00
Stefan Allius
eff3e7558b increase test coverage 2024-05-20 16:53:26 +02:00
Stefan Allius
9ac1f6f46d add Modbus retrasmissions 2024-05-19 21:17:16 +02:00
Stefan Allius
f30aa07431 don't frwd received modbus req directly
- use always the fifoto sent valid req to the inverter
- code cleanup
2024-05-19 13:42:29 +02:00
Stefan Allius
282a459ef0 add Modbus response forwarding 2024-05-19 12:23:58 +02:00
Stefan Allius
f4da16987f add fifo and timeout handler for modbus 2024-05-18 20:18:15 +02:00
Stefan Allius
036af8e127 move the Modbus instance to the parent class 2024-05-13 19:49:00 +02:00
Stefan Allius
1658036a26 store modbus params always on the server side 2024-05-12 23:09:51 +02:00
Stefan Allius
e43a02c508 improve modbus parsing
- parse Modbus messages well if another msg
   follows in the receive buffer
2024-05-11 23:40:46 +02:00
Stefan Allius
dd438bf201 add comment 2024-05-09 23:38:34 +02:00
Stefan Allius
93e82a2284 move state variable to the parent class 2024-05-09 18:22:08 +02:00
Stefan Allius
5a0456650f avoid sending modbus cmds in critical states 2024-05-09 14:20:57 +02:00
Stefan Allius
a869ead89a add MAX_DESIGNED_POWER (only readable by Modbus) 2024-05-09 14:16:15 +02:00
Stefan Allius
2ec0a59cd3 add modbus long int support 2024-05-08 23:48:41 +02:00
Stefan Allius
3fd528bdbe improve logging 2024-05-07 21:20:12 +02:00
Stefan Allius
e15387b1ff fix modbus trace 2024-05-07 19:41:07 +02:00
Stefan Allius
02d9f01947 don't send AT or Modbus cmds on closed connections 2024-05-07 18:32:56 +02:00
Stefan Allius
d5010fe053 parse modbus corect if we have received more than one message 2024-05-07 17:56:54 +02:00
Stefan Allius
f804b755a4 improve modbus trace 2024-05-06 23:18:47 +02:00
Stefan Allius
fa2626ec7a add modbus resp handler 2024-05-05 20:14:51 +02:00
Stefan Allius
a2f67e7d3e use async_write() instead of flush_send_msg() 2024-05-03 18:23:08 +02:00
Stefan Allius
f78d4ac310 remove flush_send_msg() 2024-05-03 18:22:31 +02:00
Stefan Allius
5fdad484f4 add flush_send_msg() implementation 2024-05-03 00:03:02 +02:00
Stefan Allius
dba3b458ba add Modbus support 2024-05-02 23:59:55 +02:00
Stefan Allius
05b576b198 make code more clear 2024-04-14 12:29:27 +02:00
Stefan Allius
93b89062f5 Read pv module details for HA from config file 2024-04-07 19:41:05 +02:00
Stefan Allius
8fc8a29be2 clear daily energy production at midnight 2024-04-06 00:04:25 +02:00
Stefan Allius
80f4dd722a remove useless parameter from _key_obj() 2024-04-01 02:08:28 +02:00
Stefan Allius
f38fea3807 move ignore_this_device() into base class Infos 2024-04-01 00:48:33 +02:00
Stefan Allius
e3fdeecf82 parse gen3plus inverter data 2024-03-30 01:15:07 +01:00
Stefan Allius
738dd708ac refactor ha_confs() interface 2024-03-29 19:21:59 +01:00
Stefan Allius
37cb7cc1a1 implent register mapping 2024-03-29 10:48:09 +01:00
Stefan Allius
21e46ae456 refactor info class 2024-03-28 20:56:13 +01:00
Stefan Allius
ef1fd4f913 Gen 3 plus support (#38)
* add tsun_v2 default configuration

* Add port 10000 for gen 3 plus inverters

* add monitor_sn for solarman support

* listen on port 10000 for solarman inverters

* initial version for gen 3 plus support

* refactoring split gen3 and gen3plus

* refactoring

* refactoring classes

* refactor proxy statistic counter

* - fix loggin levels
- user super() in close() and __del__()

* add config for gen 3 plus

* Add solarman config support

* refacot Message.. classes

* rename class MessageG3 into Talent

* refactor close() handler

* refactor disc() handler

* move loop() into the base class AsyncStream

* move async_read, _write and _forward into base class

* Cleanup

* move server_loop and client_loop into basic class

* add msg forwarding for solarman V5 protocol

* move server_loop() and client_loop to class AsyncStream

* rename AsyncStreamxx ton Connectionxx

* fix unit tests

* make more attributes privae

* load .env file

* wait after last test

* ignore .env

* add response handler

* Update README.md

* update unreleased changes

* home assistant add more diagnostic values

* fix typo

* Update README.md

Definition of the inverter generations added to the compatibility table

* add ha couter for 'Internal SW Exceptions'

* Update README.md

Fixes an incorrect marking in the display of the configuration file

* Update README.md

Planning documented for MS-2000 support

* S allius/issue33 (#34)

* - fix issue 33

  The TSUN Cloud now responds to contact_info and get_time messages with
  an empty display message and not with a response message as before.
  We tried to parse data from the empty message, which led to an
  exception

* Add test with empty conn_ind from inverter

* version 0.5.5

* add tsun_v2 default configuration

* Add port 10000 for gen 3 plus inverters

* add monitor_sn for solarman support

* listen on port 10000 for solarman inverters

initial version for gen 3 plus support

* refactoring split gen3 and gen3plus

* refactoring

* refactoring classes

* refactor proxy statistic counter

* - fix loggin levels
- user super() in close() and __del__()

* add config for gen 3 plus

* Add solarman config support

* refacot Message.. classes

* rename class MessageG3 into Talent

* refactor close() handler

* refactor disc() handler

* move loop() into the base class AsyncStream

* move async_read, _write and _forward into base class

* Cleanup

* move server_loop and client_loop into basic class

* add msg forwarding for solarman V5 protocol

* move server_loop() and client_loop to class AsyncStream

* rename AsyncStreamxx ton Connectionxx

* fix unit tests

* make more attributes privae

load .env file

* wait after last test

* ignore .env

* add response handler
2024-03-27 01:40:29 +01:00