fix client_mode configuration block (#252)

* fix client_mode block

* add client mode

* fix tests with client_mode values

* log client_mode configuration

* add forward flag for client_mode

* improve startup logging

* added client_mode example

* adjusted translation files

* AT commands added

* typo

* missing "PLUS"

* link to config details

* improve log msg for config problems

* improve log msg on config errors

* improve log msg for config problems

* copy CHANGELOG.md into add-on repro

---------

Co-authored-by: Michael Metz <michael.metz@siemens.com>
This commit is contained in:
Stefan Allius
2024-12-22 20:16:46 +01:00
committed by GitHub
parent 9572fbf609
commit f227faa16e
12 changed files with 144 additions and 103 deletions

View File

@@ -189,6 +189,7 @@ here. The default config reader is handled in the Config.init method'''
cls.err = f'error: {error}'
logging.error(
f"Can't read from {reader.descr()} => error\n {error}")
return cls.err
logging.info(f'Read from {reader.descr()} => {res}')
return cls.err

View File

@@ -22,4 +22,4 @@ class ConfigReadEnv(ConfigIfc):
return conf
def descr(self):
return "Read environment"
return "environment"

View File

@@ -49,7 +49,7 @@ class ModbusTcp():
and 'monitor_sn' in inv
and 'client_mode' in inv):
client = inv['client_mode']
# logging.info(f"SerialNo:{inv['monitor_sn']} host:{client['host']} port:{client['port']}") # noqa: E501
logger.info(f"'client_mode' for snr: {inv['monitor_sn']} host: {client['host']}:{client['port']}, forward: {client['forward']}") # noqa: E501
loop.create_task(self.modbus_loop(client['host'],
client['port'],
inv['monitor_sn'],

View File

@@ -142,7 +142,7 @@ def main(): # pragma: no cover
parser.add_argument('-t', '--toml_config', type=str,
help='read user config from toml-file')
parser.add_argument('-l', '--log_path', type=str,
default='log/',
default='./log/',
help='set path for the logging files')
parser.add_argument('-b', '--log_backups', type=int,
default=0,
@@ -159,11 +159,15 @@ def main(): # pragma: no cover
logging.config.fileConfig('logging.ini')
logging.info(f'Server "{serv_name} - {version}" will be started')
logging.info(f'current dir: {os.getcwd()}')
logging.info(f"config_path: {args.config_path}")
logging.info(f"json_config: {args.json_config}")
logging.info(f"toml_config: {args.toml_config}")
logging.info(f"log_path: {args.log_path}")
logging.info(f"log_backups: {args.log_backups} days")
if args.log_backups == 0:
logging.info("log_backups: unlimited")
else:
logging.info(f"log_backups: {args.log_backups} days")
log_level = get_log_level()
logging.info('******')
@@ -204,6 +208,7 @@ def main(): # pragma: no cover
# and we can't receive and handle the UNIX signals!
#
for inv_class, port in [(InverterG3, 5005), (InverterG3P, 10000)]:
logging.info(f'listen on port: {port} for inverters')
loop.create_task(asyncio.start_server(lambda r, w, i=inv_class:
handle_client(r, w, i),
'0.0.0.0', port))