increase test coverage
This commit is contained in:
@@ -1,3 +1,16 @@
|
||||
'''MODBUS module for TSUN inverter support
|
||||
|
||||
TSUN uses the MODBUS in the RTU transmission mode over serial line.
|
||||
see: https://modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf
|
||||
see: https://modbus.org/docs/Modbus_over_serial_line_V1_02.pdf
|
||||
|
||||
A Modbus PDU consists of: 'Function-Code' + 'Data'
|
||||
A Modbus RTU message consists of: 'Addr' + 'Modbus-PDU' + 'CRC-16'
|
||||
The inverter is a MODBUS server and the proxy the MODBUS client.
|
||||
|
||||
The 16-bit CRC is known as CRC-16-ANSI(reverse)
|
||||
see: https://en.wikipedia.org/wiki/Computation_of_cyclic_redundancy_checks
|
||||
'''
|
||||
import struct
|
||||
import logging
|
||||
import asyncio
|
||||
@@ -8,30 +21,21 @@ if __name__ == "app.src.modbus":
|
||||
else: # pragma: no cover
|
||||
from infos import Register
|
||||
|
||||
#######
|
||||
# TSUN uses the Modbus in the RTU transmission mode.
|
||||
# see: https://modbus.org/docs/Modbus_over_serial_line_V1_02.pdf
|
||||
#
|
||||
# A Modbus PDU consists of: 'Function-Code' + 'Data'
|
||||
# A Modbus RTU message consists of: 'Addr' + 'Modbus-PDU' + 'CRC-16'
|
||||
#
|
||||
# The 16-bit CRC is known as CRC-16-ANSI(reverse)
|
||||
# see: https://en.wikipedia.org/wiki/Computation_of_cyclic_redundancy_checks
|
||||
#######
|
||||
|
||||
CRC_POLY = 0xA001 # (LSBF/reverse)
|
||||
CRC_INIT = 0xFFFF
|
||||
|
||||
|
||||
class Modbus():
|
||||
'''Simple MODBUS implementation with TX queue and retransmit timer'''
|
||||
INV_ADDR = 1
|
||||
'''MODBUS slave address of the TSUN inverter'''
|
||||
'''MODBUS server address of the TSUN inverter'''
|
||||
READ_REGS = 3
|
||||
'''MODBUS function code: Read Holding Register'''
|
||||
READ_INPUTS = 4
|
||||
'''MODBUS function code: Read Input Register'''
|
||||
WRITE_SINGLE_REG = 6
|
||||
'''Modbus function code: Write Single Register'''
|
||||
'''Modbus function code: Write Single Register'''
|
||||
|
||||
__crc_tab = []
|
||||
map = {
|
||||
@@ -69,12 +73,12 @@ class Modbus():
|
||||
0x3029: {'reg': Register.PV4_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
|
||||
}
|
||||
|
||||
def __init__(self, snd_handler: Callable[[bool], None], timeout: int = 1):
|
||||
def __init__(self, snd_handler: Callable[[str], None], timeout: int = 1):
|
||||
if not len(self.__crc_tab):
|
||||
self.__build_crc_tab(CRC_POLY)
|
||||
self.que = asyncio.Queue(100)
|
||||
self.snd_handler = snd_handler
|
||||
'''Send handler to transmit a MODBUS request'''
|
||||
'''Send handler to transmit a MODBUS RTU request'''
|
||||
self.rsp_handler = None
|
||||
'''Response handler to forward the response'''
|
||||
self.timeout = timeout
|
||||
@@ -99,14 +103,13 @@ class Modbus():
|
||||
self.tim = None
|
||||
|
||||
def __del__(self):
|
||||
if type(self.counter) is not None:
|
||||
logging.info(f'Modbus __del__:\n {self.counter}')
|
||||
logging.info(f'Modbus __del__:\n {self.counter}')
|
||||
|
||||
def build_msg(self, addr: int, func: int, reg: int, val: int) -> None:
|
||||
"""Build MODBUS RTU message frame and add it to the tx queue
|
||||
"""Build MODBUS RTU request frame and add it to the tx queue
|
||||
|
||||
Keyword arguments:
|
||||
addr: RTU slave address
|
||||
addr: RTU server address (inverter)
|
||||
func: MODBUS function code
|
||||
reg: 16-bit register number
|
||||
val: 16 bit value
|
||||
@@ -120,7 +123,7 @@ class Modbus():
|
||||
|
||||
def recv_req(self, buf: bytearray,
|
||||
rsp_handler: Callable[[None], None] = None) -> bool:
|
||||
"""Add the received Modbus request to the tx queue
|
||||
"""Add the received Modbus RTU request to the tx queue
|
||||
|
||||
Keyword arguments:
|
||||
buf: Modbus RTU pdu incl ADDR byte and trailing CRC
|
||||
@@ -241,7 +244,7 @@ class Modbus():
|
||||
logging.debug(f'Modbus retrans {self}')
|
||||
self.retry_cnt += 1
|
||||
self.__start_timer()
|
||||
self.snd_handler(self.last_req, retrans=True)
|
||||
self.snd_handler(self.last_req, state='Retrans')
|
||||
else:
|
||||
logging.info(f'Modbus timeout {self}')
|
||||
self.counter['timeouts'] += 1
|
||||
@@ -264,7 +267,7 @@ class Modbus():
|
||||
self.last_len = res[1]
|
||||
self.retry_cnt = 0
|
||||
self.__start_timer()
|
||||
self.snd_handler(self.last_req, retrans=False)
|
||||
self.snd_handler(self.last_req, state='Command')
|
||||
except asyncio.QueueEmpty:
|
||||
pass
|
||||
|
||||
|
||||
Reference in New Issue