Gen 3 plus support (#38)

* add tsun_v2 default configuration

* Add port 10000 for gen 3 plus inverters

* add monitor_sn for solarman support

* listen on port 10000 for solarman inverters

* initial version for gen 3 plus support

* refactoring split gen3 and gen3plus

* refactoring

* refactoring classes

* refactor proxy statistic counter

* - fix loggin levels
- user super() in close() and __del__()

* add config for gen 3 plus

* Add solarman config support

* refacot Message.. classes

* rename class MessageG3 into Talent

* refactor close() handler

* refactor disc() handler

* move loop() into the base class AsyncStream

* move async_read, _write and _forward into base class

* Cleanup

* move server_loop and client_loop into basic class

* add msg forwarding for solarman V5 protocol

* move server_loop() and client_loop to class AsyncStream

* rename AsyncStreamxx ton Connectionxx

* fix unit tests

* make more attributes privae

* load .env file

* wait after last test

* ignore .env

* add response handler

* Update README.md

* update unreleased changes

* home assistant add more diagnostic values

* fix typo

* Update README.md

Definition of the inverter generations added to the compatibility table

* add ha couter for 'Internal SW Exceptions'

* Update README.md

Fixes an incorrect marking in the display of the configuration file

* Update README.md

Planning documented for MS-2000 support

* S allius/issue33 (#34)

* - fix issue 33

  The TSUN Cloud now responds to contact_info and get_time messages with
  an empty display message and not with a response message as before.
  We tried to parse data from the empty message, which led to an
  exception

* Add test with empty conn_ind from inverter

* version 0.5.5

* add tsun_v2 default configuration

* Add port 10000 for gen 3 plus inverters

* add monitor_sn for solarman support

* listen on port 10000 for solarman inverters

initial version for gen 3 plus support

* refactoring split gen3 and gen3plus

* refactoring

* refactoring classes

* refactor proxy statistic counter

* - fix loggin levels
- user super() in close() and __del__()

* add config for gen 3 plus

* Add solarman config support

* refacot Message.. classes

* rename class MessageG3 into Talent

* refactor close() handler

* refactor disc() handler

* move loop() into the base class AsyncStream

* move async_read, _write and _forward into base class

* Cleanup

* move server_loop and client_loop into basic class

* add msg forwarding for solarman V5 protocol

* move server_loop() and client_loop to class AsyncStream

* rename AsyncStreamxx ton Connectionxx

* fix unit tests

* make more attributes privae

load .env file

* wait after last test

* ignore .env

* add response handler
This commit is contained in:
Stefan Allius
2024-03-27 01:40:29 +01:00
committed by GitHub
parent 542f422e1e
commit ef1fd4f913
23 changed files with 1595 additions and 554 deletions

View File

@@ -94,11 +94,16 @@ You find more details here: https://toml.io/en/v1.0.0
```toml
# configuration to reach tsun cloud
# configuration for tsun cloud for 'generation 3' inverters
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
tsun.host = 'logger.talent-monitoring.com'
tsun.port = 5005
# configuration for solarman cloud for 'generation 3 plus' inverters
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
solarman.host = 'iot.talent-monitoring.com'
solarman.port = 10000
# mqtt broker configuration
mqtt.host = 'mqtt' # URL or IP address of the mqtt broker
@@ -125,10 +130,23 @@ inverters.allow_all = false # True: allow inverters, even if we have no invert
[inverters."R17xxxxxxxxxxxx1"]
node_id = 'inv1' # Optional, MQTT replacement for inverters serial number
suggested_area = 'roof' # Optional, suggested installation area for home-assistant
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
[inverters."R17xxxxxxxxxxxx2"]
node_id = 'inv2' # Optional, MQTT replacement for inverters serial number
suggested_area = 'balcony' # Optional, suggested installation area for home-assistant
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
[inverters."Y17xxxxxxxxxxxx1"]
monitor_sn = 2000000000
node_id = 'inv_3' # MQTT replacement for inverters serial number
suggested_area = 'Garage' # suggested installation place for home-assistant
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
pv3 = {type = 'RSM40-8-405M', manufacturer = 'Risen'}
pv4 = {type = 'RSM40-8-405M', manufacturer = 'Risen'}
```