* add tsun_v2 default configuration * Add port 10000 for gen 3 plus inverters * add monitor_sn for solarman support * listen on port 10000 for solarman inverters * initial version for gen 3 plus support * refactoring split gen3 and gen3plus * refactoring * refactoring classes * refactor proxy statistic counter * - fix loggin levels - user super() in close() and __del__() * add config for gen 3 plus * Add solarman config support * refacot Message.. classes * rename class MessageG3 into Talent * refactor close() handler * refactor disc() handler * move loop() into the base class AsyncStream * move async_read, _write and _forward into base class * Cleanup * move server_loop and client_loop into basic class * add msg forwarding for solarman V5 protocol * move server_loop() and client_loop to class AsyncStream * rename AsyncStreamxx ton Connectionxx * fix unit tests * make more attributes privae * load .env file * wait after last test * ignore .env * add response handler * Update README.md * update unreleased changes * home assistant add more diagnostic values * fix typo * Update README.md Definition of the inverter generations added to the compatibility table * add ha couter for 'Internal SW Exceptions' * Update README.md Fixes an incorrect marking in the display of the configuration file * Update README.md Planning documented for MS-2000 support * S allius/issue33 (#34) * - fix issue 33 The TSUN Cloud now responds to contact_info and get_time messages with an empty display message and not with a response message as before. We tried to parse data from the empty message, which led to an exception * Add test with empty conn_ind from inverter * version 0.5.5 * add tsun_v2 default configuration * Add port 10000 for gen 3 plus inverters * add monitor_sn for solarman support * listen on port 10000 for solarman inverters initial version for gen 3 plus support * refactoring split gen3 and gen3plus * refactoring * refactoring classes * refactor proxy statistic counter * - fix loggin levels - user super() in close() and __del__() * add config for gen 3 plus * Add solarman config support * refacot Message.. classes * rename class MessageG3 into Talent * refactor close() handler * refactor disc() handler * move loop() into the base class AsyncStream * move async_read, _write and _forward into base class * Cleanup * move server_loop and client_loop into basic class * add msg forwarding for solarman V5 protocol * move server_loop() and client_loop to class AsyncStream * rename AsyncStreamxx ton Connectionxx * fix unit tests * make more attributes privae load .env file * wait after last test * ignore .env * add response handler
This commit is contained in:
20
README.md
20
README.md
@@ -94,11 +94,16 @@ You find more details here: https://toml.io/en/v1.0.0
|
||||
|
||||
|
||||
```toml
|
||||
# configuration to reach tsun cloud
|
||||
# configuration for tsun cloud for 'generation 3' inverters
|
||||
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
||||
tsun.host = 'logger.talent-monitoring.com'
|
||||
tsun.port = 5005
|
||||
|
||||
# configuration for solarman cloud for 'generation 3 plus' inverters
|
||||
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
|
||||
solarman.host = 'iot.talent-monitoring.com'
|
||||
solarman.port = 10000
|
||||
|
||||
|
||||
# mqtt broker configuration
|
||||
mqtt.host = 'mqtt' # URL or IP address of the mqtt broker
|
||||
@@ -125,10 +130,23 @@ inverters.allow_all = false # True: allow inverters, even if we have no invert
|
||||
[inverters."R17xxxxxxxxxxxx1"]
|
||||
node_id = 'inv1' # Optional, MQTT replacement for inverters serial number
|
||||
suggested_area = 'roof' # Optional, suggested installation area for home-assistant
|
||||
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
|
||||
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
|
||||
|
||||
[inverters."R17xxxxxxxxxxxx2"]
|
||||
node_id = 'inv2' # Optional, MQTT replacement for inverters serial number
|
||||
suggested_area = 'balcony' # Optional, suggested installation area for home-assistant
|
||||
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
|
||||
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
|
||||
|
||||
[inverters."Y17xxxxxxxxxxxx1"]
|
||||
monitor_sn = 2000000000
|
||||
node_id = 'inv_3' # MQTT replacement for inverters serial number
|
||||
suggested_area = 'Garage' # suggested installation place for home-assistant
|
||||
pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
|
||||
pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'}
|
||||
pv3 = {type = 'RSM40-8-405M', manufacturer = 'Risen'}
|
||||
pv4 = {type = 'RSM40-8-405M', manufacturer = 'Risen'}
|
||||
|
||||
|
||||
```
|
||||
|
||||