Merge branch 'dev-0.8.0' into s-allius/issue77
This commit is contained in:
@@ -3,7 +3,7 @@
|
||||
import shutil
|
||||
import tomllib
|
||||
import logging
|
||||
from schema import Schema, And, Use, Optional
|
||||
from schema import Schema, And, Or, Use, Optional
|
||||
|
||||
|
||||
class Config():
|
||||
@@ -38,6 +38,14 @@ class Config():
|
||||
'proxy_node_id': Use(str),
|
||||
'proxy_unique_id': Use(str)
|
||||
},
|
||||
'gen3plus': {
|
||||
'at_acl': {
|
||||
Or('mqtt', 'tsun'): {
|
||||
'allow': [str],
|
||||
Optional('block', default=[]): [str]
|
||||
}
|
||||
}
|
||||
},
|
||||
'inverters': {
|
||||
'allow_all': Use(bool), And(Use(str), lambda s: len(s) == 16): {
|
||||
Optional('monitor_sn', default=0): Use(int),
|
||||
@@ -125,7 +133,8 @@ class Config():
|
||||
|
||||
# merge the default and the user config
|
||||
config = def_config.copy()
|
||||
for key in ['tsun', 'solarman', 'mqtt', 'ha', 'inverters']:
|
||||
for key in ['tsun', 'solarman', 'mqtt', 'ha', 'inverters',
|
||||
'gen3plus']:
|
||||
if key in usr_config:
|
||||
config[key] |= usr_config[key]
|
||||
|
||||
|
||||
@@ -91,6 +91,7 @@ class SolarmanV5(Message):
|
||||
# MODbus or AT cmd
|
||||
0x4510: self.msg_command_req, # from server
|
||||
0x1510: self.msg_command_rsp, # from inverter
|
||||
# 0x0510: self.msg_command_rsp, # from inverter
|
||||
}
|
||||
|
||||
self.log_lvl = {
|
||||
@@ -116,6 +117,10 @@ class SolarmanV5(Message):
|
||||
0x1510: self.get_cmd_rsp_log_lvl,
|
||||
}
|
||||
self.modbus_elms = 0 # for unit tests
|
||||
g3p_cnf = Config.get('gen3plus')
|
||||
|
||||
if 'at_acl' in g3p_cnf: # pragma: no cover
|
||||
self.at_acl = g3p_cnf['at_acl']
|
||||
|
||||
'''
|
||||
Our puplic methods
|
||||
@@ -347,9 +352,24 @@ class SolarmanV5(Message):
|
||||
return
|
||||
self.mb.build_msg(Modbus.INV_ADDR, func, addr, val, log_lvl)
|
||||
|
||||
def at_cmd_forbidden(self, cmd: str, connection: str) -> bool:
|
||||
return not cmd.startswith(tuple(self.at_acl[connection]['allow'])) or \
|
||||
cmd.startswith(tuple(self.at_acl[connection]['block']))
|
||||
|
||||
async def send_at_cmd(self, AT_cmd: str) -> None:
|
||||
if self.state != self.STATE_UP:
|
||||
return
|
||||
AT_cmd = AT_cmd.strip()
|
||||
|
||||
if self.at_cmd_forbidden(cmd=AT_cmd, connection='mqtt'):
|
||||
data_json = f'\'{AT_cmd}\' is forbidden'
|
||||
node_id = self.node_id
|
||||
key = 'at_resp'
|
||||
logger.info(f'{key}: {data_json}')
|
||||
asyncio.ensure_future(
|
||||
self.publish_mqtt(f'{self.entity_prfx}{node_id}{key}', data_json)) # noqa: E501
|
||||
return
|
||||
|
||||
self.forward_at_cmd_resp = False
|
||||
self.__build_header(0x4510)
|
||||
self._send_buffer += struct.pack(f'<BHLLL{len(AT_cmd)}sc', self.AT_CMD,
|
||||
@@ -457,8 +477,13 @@ class SolarmanV5(Message):
|
||||
result = struct.unpack_from('<B', data, 0)
|
||||
ftype = result[0]
|
||||
if ftype == self.AT_CMD:
|
||||
AT_cmd = data[15:].decode()
|
||||
if self.at_cmd_forbidden(cmd=AT_cmd, connection='tsun'):
|
||||
self.inc_counter('AT_Command_Blocked')
|
||||
return
|
||||
self.inc_counter('AT_Command')
|
||||
self.forward_at_cmd_resp = True
|
||||
|
||||
elif ftype == self.MB_RTU_CMD:
|
||||
if self.remoteStream.mb.recv_req(data[15:],
|
||||
self.__forward_msg()):
|
||||
|
||||
@@ -29,6 +29,7 @@ class Register(Enum):
|
||||
INVALID_MSG_FMT = 58
|
||||
AT_COMMAND = 59
|
||||
MODBUS_COMMAND = 60
|
||||
AT_COMMAND_BLOCKED = 61
|
||||
OUTPUT_POWER = 83
|
||||
RATED_POWER = 84
|
||||
INVERTER_TEMP = 85
|
||||
@@ -210,17 +211,18 @@ class Infos:
|
||||
Register.PV6_MODEL: {'name': ['inverter', 'PV6_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
|
||||
# proxy:
|
||||
Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': '| int', 'name': 'Active Inverter Connections', 'icon': 'mdi:counter'}}, # noqa: E501
|
||||
Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': '| int', 'name': 'Unknown Serial No', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.UNKNOWN_MSG: {'name': ['proxy', 'Unknown_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_msg_', 'fmt': '| int', 'name': 'Unknown Msg Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INVALID_DATA_TYPE: {'name': ['proxy', 'Invalid_Data_Type'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_data_type_', 'fmt': '| int', 'name': 'Invalid Data Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INTERNAL_ERROR: {'name': ['proxy', 'Internal_Error'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'intern_err_', 'fmt': '| int', 'name': 'Internal Error', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic', 'en': False}}, # noqa: E501
|
||||
Register.UNKNOWN_CTRL: {'name': ['proxy', 'Unknown_Ctrl'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_ctrl_', 'fmt': '| int', 'name': 'Unknown Control Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.OTA_START_MSG: {'name': ['proxy', 'OTA_Start_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'ota_start_cmd_', 'fmt': '| int', 'name': 'OTA Start Cmd', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.SW_EXCEPTION: {'name': ['proxy', 'SW_Exception'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'sw_exception_', 'fmt': '| int', 'name': 'Internal SW Exception', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INVALID_MSG_FMT: {'name': ['proxy', 'Invalid_Msg_Format'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_msg_fmt_', 'fmt': '| int', 'name': 'Invalid Message Format', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.AT_COMMAND: {'name': ['proxy', 'AT_Command'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'at_cmd_', 'fmt': '| int', 'name': 'AT Command', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.MODBUS_COMMAND: {'name': ['proxy', 'Modbus_Command'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'modbus_cmd_', 'fmt': '| int', 'name': 'Modbus Command', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': '| int', 'name': 'Active Inverter Connections', 'icon': 'mdi:counter'}}, # noqa: E501
|
||||
Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': '| int', 'name': 'Unknown Serial No', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.UNKNOWN_MSG: {'name': ['proxy', 'Unknown_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_msg_', 'fmt': '| int', 'name': 'Unknown Msg Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INVALID_DATA_TYPE: {'name': ['proxy', 'Invalid_Data_Type'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_data_type_', 'fmt': '| int', 'name': 'Invalid Data Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INTERNAL_ERROR: {'name': ['proxy', 'Internal_Error'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'intern_err_', 'fmt': '| int', 'name': 'Internal Error', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic', 'en': False}}, # noqa: E501
|
||||
Register.UNKNOWN_CTRL: {'name': ['proxy', 'Unknown_Ctrl'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_ctrl_', 'fmt': '| int', 'name': 'Unknown Control Type', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.OTA_START_MSG: {'name': ['proxy', 'OTA_Start_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'ota_start_cmd_', 'fmt': '| int', 'name': 'OTA Start Cmd', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.SW_EXCEPTION: {'name': ['proxy', 'SW_Exception'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'sw_exception_', 'fmt': '| int', 'name': 'Internal SW Exception', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INVALID_MSG_FMT: {'name': ['proxy', 'Invalid_Msg_Format'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_msg_fmt_', 'fmt': '| int', 'name': 'Invalid Message Format', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.AT_COMMAND: {'name': ['proxy', 'AT_Command'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'at_cmd_', 'fmt': '| int', 'name': 'AT Command', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.AT_COMMAND_BLOCKED: {'name': ['proxy', 'AT_Command_Blocked'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'at_cmd_blocked_', 'fmt': '| int', 'name': 'AT Command Blocked', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.MODBUS_COMMAND: {'name': ['proxy', 'Modbus_Command'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'modbus_cmd_', 'fmt': '| int', 'name': 'Modbus Command', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':'| float','name': 'Grid Voltage'}}, # noqa: E501
|
||||
|
||||
# events
|
||||
@@ -404,7 +406,7 @@ class Infos:
|
||||
attr['unit_of_meas'] = row['unit'] # 'unit_of_meas'
|
||||
if 'icon' in ha:
|
||||
attr['ic'] = ha['icon'] # icon for the entity
|
||||
if 'nat_prc' in ha:
|
||||
if 'nat_prc' in ha: # pragma: no cover
|
||||
attr['sug_dsp_prc'] = ha['nat_prc'] # precison of floats
|
||||
if 'ent_cat' in ha:
|
||||
attr['ent_cat'] = ha['ent_cat'] # diagnostic, config
|
||||
|
||||
Reference in New Issue