* set equipment model dor DCU1000 devices

* DCU1000: add temp sensor and mppt states

* DCU1000: add total generation

* add more DCU1000 registers for MODBUS polling

* improve names of batterie measurements

* add more diagnostic registers

* adapt unit tests

* move uml files into subfolder

* add sensors for batterie cell voltages

* swap On and Off for MPPT status
This commit is contained in:
Stefan Allius
2025-03-25 20:10:10 +01:00
committed by GitHub
parent 3eb6a24dcb
commit dff8934b82
11 changed files with 116 additions and 67 deletions

View File

@@ -136,25 +136,36 @@ class RegisterMap:
0x42010034: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 voltage
0x42010036: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 current
0x42010038: {'reg': Register.BATT_38, 'fmt': '!h'}, # noqa: E501
0x4201003a: {'reg': Register.BATT_3a, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x4201003a: {'reg': Register.BATT_TOTAL_GEN, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x4201003c: {'reg': Register.BATT_STATUS_1, 'fmt': '!h'}, # noqa: E501 MPTT-1 Status?
0x4201003e: {'reg': Register.BATT_STATUS_2, 'fmt': '!h'}, # noqa: E501 MPTT-2 Status?
0x42010040: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x42010042: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x42010044: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
0x42010046: {'reg': Register.BATT_46, 'fmt': '!h'}, # noqa: E501
0x42010048: {'reg': Register.BATT_48, 'fmt': '!h'}, # noqa: E501
0x4201004a: {'reg': Register.BATT_4a, 'fmt': '!h'}, # noqa: E501
0x4201004c: {'reg': Register.BATT_4c, 'fmt': '!h'}, # noqa: E501
0x4201004e: {'reg': Register.BATT_4e, 'fmt': '!h'}, # noqa: E501
0x42010046: {'reg': Register.BATT_CELL1_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010048: {'reg': Register.BATT_CELL2_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201004a: {'reg': Register.BATT_CELL3_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201004c: {'reg': Register.BATT_CELL4_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201004e: {'reg': Register.BATT_CELL5_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010050: {'reg': Register.BATT_CELL6_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010052: {'reg': Register.BATT_CELL7_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010054: {'reg': Register.BATT_CELL8_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010056: {'reg': Register.BATT_CELL9_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010058: {'reg': Register.BATT_CELL10_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201005a: {'reg': Register.BATT_CELL11_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201005c: {'reg': Register.BATT_CELL12_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x4201005e: {'reg': Register.BATT_CELL13_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010060: {'reg': Register.BATT_CELL14_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010062: {'reg': Register.BATT_CELL15_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010064: {'reg': Register.BATT_CELL16_VOLT, 'fmt': '!h', 'ratio': 0.001}, # noqa: E501
0x42010066: {'reg': Register.BATT_66, 'fmt': '!h'}, # noqa: E501
0x42010068: {'reg': Register.BATT_TEMP_1, 'fmt': '!h'}, # noqa: E501 batterie temp 1
0x4201006a: {'reg': Register.BATT_TEMP_2, 'fmt': '!h'}, # noqa: E501 batterie temp 2
0x42010066: {'reg': Register.BATT_TEMP_1, 'fmt': '!h'}, # noqa: E501
0x42010068: {'reg': Register.BATT_TEMP_2, 'fmt': '!h'}, # noqa: E501
0x4201006a: {'reg': Register.BATT_TEMP_3, 'fmt': '!h'}, # noqa: E501
0x4201006c: {'reg': Register.BATT_OUT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x4201006e: {'reg': Register.BATT_OUT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
0x42010070: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!h'}, # noqa: E501, state of output value 0 or 1
0x42010072: {'reg': Register.BATT_TEMP_3, 'fmt': '!h'}, # noqa: E501 controller temp
0x42010072: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E501 controller temp
0x42010074: {'reg': Register.BATT_74, 'fmt': '!h'}, # noqa: E501, control input 0..2048
0x42010076: {'reg': Register.BATT_76, 'fmt': '!h'}, # noqa: E501
0x42010078: {'reg': Register.BATT_78, 'fmt': '!h'}, # noqa: E501

View File

@@ -392,10 +392,13 @@ class SolarmanV5(SolarmanBase):
def _set_config_parms(self, inv: dict, serial_no: str = ""):
'''init connection with params from the configuration'''
super()._set_config_parms(inv)
snr = serial_no[:3]
if '410' == snr:
self.db.set_db_def_value(Register.EQUIPMENT_MODEL,
'TSOL-DC1000')
self.sensor_list = inv['sensor_list']
if 0 == self.sensor_list:
snr = serial_no[:3]
if '410' == snr:
self.sensor_list = 0x3026
self.mb_regs = [{'addr': 0x0000, 'len': 45}]