S allius/issue128 (#130)
* set Register.NO_INPUTS fix to 4 for GEN3PLUS * don't set Register.NO_INPUTS per MODBUS * fix unit tests * register OUTPUT_COEFFICIENT at HA * update changelog * - Home Assistant: improve inverter status value texts * - GEN3: add inverter status * on closing send outstanding MQTT data to the broker * force MQTT publish on every conn open and close * reset inverter state on close - workaround which reset the inverter status to offline when the inverter has a very low output power on connection close * improve client modified - reduce the polling cadence to 30s - set controller statistics for HA * client mode set controller IP for HA
This commit is contained in:
@@ -54,7 +54,11 @@ class SolarmanV5(Message):
|
||||
AT_CMD = 1
|
||||
MB_RTU_CMD = 2
|
||||
MB_START_TIMEOUT = 40
|
||||
'''start delay for Modbus polling in server mode'''
|
||||
MB_REGULAR_TIMEOUT = 60
|
||||
'''regular Modbus polling time in server mode'''
|
||||
MB_CLIENT_DATA_UP = 30
|
||||
'''Data up time in client mode'''
|
||||
|
||||
def __init__(self, server_side: bool):
|
||||
super().__init__(server_side, self.send_modbus_cb, mb_timeout=5)
|
||||
@@ -130,6 +134,8 @@ class SolarmanV5(Message):
|
||||
|
||||
self.node_id = 'G3P' # will be overwritten in __set_serial_no
|
||||
self.mb_timer = Timer(self.mb_timout_cb, self.node_id)
|
||||
self.mb_timeout = self.MB_REGULAR_TIMEOUT
|
||||
'''timer value for next Modbus polling request'''
|
||||
self.modbus_polling = False
|
||||
|
||||
'''
|
||||
@@ -146,18 +152,25 @@ class SolarmanV5(Message):
|
||||
self.mb_timer.close()
|
||||
super().close()
|
||||
|
||||
async def send_start_cmd(self, snr: int):
|
||||
async def send_start_cmd(self, snr: int, host: str):
|
||||
self.no_forwarding = True
|
||||
self.snr = snr
|
||||
self.__set_serial_no(snr)
|
||||
self.mb_timeout = self.MB_CLIENT_DATA_UP
|
||||
self.db.set_db_def_value(Register.IP_ADDRESS, host)
|
||||
self.db.set_db_def_value(Register.DATA_UP_INTERVAL,
|
||||
self.mb_timeout)
|
||||
self.db.set_db_def_value(Register.HEARTBEAT_INTERVAL,
|
||||
120) # fixme
|
||||
self.new_data['controller'] = True
|
||||
|
||||
self.__send_ack_rsp(0x1710, ftype=0)
|
||||
await self.async_write('Send Start Command:')
|
||||
self._send_buffer = bytearray(0)
|
||||
|
||||
self.state = State.up
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.INFO)
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.DEBUG)
|
||||
self.mb_timer.start(self.mb_timeout)
|
||||
|
||||
def new_state_up(self):
|
||||
if self.state is not State.up:
|
||||
@@ -403,11 +416,11 @@ class SolarmanV5(Message):
|
||||
self._send_modbus_cmd(func, addr, val, log_lvl)
|
||||
|
||||
def mb_timout_cb(self, exp_cnt):
|
||||
self.mb_timer.start(self.MB_REGULAR_TIMEOUT)
|
||||
self.mb_timer.start(self.mb_timeout)
|
||||
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.DEBUG)
|
||||
|
||||
if 0 == (exp_cnt % 30):
|
||||
if 1 == (exp_cnt % 30):
|
||||
# logging.info("Regular Modbus Status request")
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.DEBUG)
|
||||
|
||||
|
||||
Reference in New Issue