Update README.md
Planning documented for MS-2000 support
This commit is contained in:
24
README.md
24
README.md
@@ -40,7 +40,8 @@ If you use a Pi-hole, you can also store the host entry in the Pi-hole.
|
|||||||
|
|
||||||
## Features
|
## Features
|
||||||
|
|
||||||
- supports TSOL MS300, MS350, MS400, MS600, MS700 and MS800 inverters from TSUN
|
- supports TSUN G3 inverters: TSOL MS-300, MS-350, MS-400, MS-600, MS-700 and MS-800
|
||||||
|
- support for TSUN G3 Plus inverters is in preperation (e.g. MS-2000)
|
||||||
- `MQTT` support
|
- `MQTT` support
|
||||||
- `Home-Assistant` auto-discovery support
|
- `Home-Assistant` auto-discovery support
|
||||||
- Self-sufficient island operation without internet
|
- Self-sufficient island operation without internet
|
||||||
@@ -158,12 +159,21 @@ It must be ensured that this address is not mapped to the proxy!
|
|||||||
In the following table you will find an overview of which inverter model has been tested for compatibility with which firmware version.
|
In the following table you will find an overview of which inverter model has been tested for compatibility with which firmware version.
|
||||||
A combination with a red question mark should work, but I have not checked it in detail.
|
A combination with a red question mark should work, but I have not checked it in detail.
|
||||||
|
|
||||||
Micro Inverter Model | Fw. 1.00.06 | Fw. 1.00.17 | Fw. 1.00.20
|
Micro Inverter Model | Fw. 1.00.06 | Fw. 1.00.17 | Fw. 1.00.20| Fw. 1.1.00.0B
|
||||||
:---|:---:|:---:|:---:
|
:---|:---:|:---:|:---:|:---:|
|
||||||
G3 micro inverters (single MPPT):<br>MS-300, MS-350, MS-400| ❓ | ❓ | ❓
|
G3 micro inverters (single MPPT):<br>MS-300, MS-350, MS-400| ❓ | ❓ | ❓ |➖
|
||||||
G3 micro inverters (dual MPPT):<br>MS-600, MS-700, MS-800| ✔️ | ✔️ | ✔️
|
G3 micro inverters (dual MPPT):<br>MS-600, MS-700, MS-800| ✔️ | ✔️ | ✔️ |➖
|
||||||
G3 PLUS micro inverters:<br>MS-1600, MS-1800, MS-2000| ❓ | ❓ | ❓
|
G3 PLUS micro inverters:<br>MS-1600, MS-1800, MS-2000| ➖ |➖ | ➖ | 🚧
|
||||||
balcony micro inverters:<br>MS-400-D, MS-800-D, MS-2000-D| ❓ | ❓ | ❓
|
balcony micro inverters:<br>MS-400-D, MS-800-D, MS-2000-D| ❓ | ❓ | ❓| ❓
|
||||||
|
|
||||||
|
```
|
||||||
|
Legend
|
||||||
|
➖: Firmware not available for this devices
|
||||||
|
✔️: proxy support testet
|
||||||
|
❓: proxy support possible but not testet
|
||||||
|
🚧: Proxy support in preparation
|
||||||
|
```
|
||||||
|
❗The new inverters of the G3Plus generation (e.g. MS-2000) use a completely different protocol for data transmission to the TSUN server. I already have such an inverter in operation and am working on the integration for the proxy version 0.6. The serial numbers of these inverters start with `Y17E` instead of `R17E`
|
||||||
|
|
||||||
If you have one of these combinations with a red question mark, it would be very nice if you could send me a proxy trace so that I can carry out the detailed checks and adjust the device and system tests. [Ask here how to send a trace](https://github.com/s-allius/tsun-gen3-proxy/discussions/categories/traces-for-compatibility-check)
|
If you have one of these combinations with a red question mark, it would be very nice if you could send me a proxy trace so that I can carry out the detailed checks and adjust the device and system tests. [Ask here how to send a trace](https://github.com/s-allius/tsun-gen3-proxy/discussions/categories/traces-for-compatibility-check)
|
||||||
|
|
||||||
|
|||||||