Dev 0.11 (#200)
* Code Cleanup (#158) * print coverage report * create sonar-project property file * install all py dependencies in one step * code cleanup * reduce cognitive complexity * do not build on *.yml changes * optimise versionstring handling (#159) - Reading the version string from the image updates it even if the image is re-pulled without re-deployment * fix linter warning * exclude *.pyi filese * ignore some rules for tests * cleanup (#160) * Sonar qube 3 (#163) fix SonarQube warnings in modbus.py * Sonar qube 3 (#164) * fix SonarQube warnings * Sonar qube 3 (#165) * cleanup * Add support for TSUN Titan inverter Fixes #161 * fix SonarQube warnings * fix error * rename field "config" * SonarQube reads flake8 output * don't stop on flake8 errors * flake8 scan only app/src for SonarQube * update flake8 run * ignore flake8 C901 * cleanup * fix linter warnings * ignore changed *.yml files * read sensor list solarman data packets * catch 'No route to' error and log only in debug mode * fix unit tests * add sensor_list configuration * adapt unit tests * fix SonarQube warnings * Sonar qube 3 (#166) * add unittests for mqtt.py * add mock * move test requirements into a file * fix unit tests * fix formating * initial version * fix SonarQube warning * Sonar qube 4 (#169) * add unit test for inverter.py * fix SonarQube warning * Sonar qube 5 (#170) * fix SonarLints warnings * use random IP adresses for unit tests * Docker: The description ist missing (#171) Fixes #167 * S allius/issue167 (#172) * cleanup * Sonar qube 6 (#174) * test class ModbusConn * Sonar qube 3 (#178) * add more unit tests * GEN3: don't crash on overwritten msg in the receive buffer * improve test coverage und reduce test delays * reduce cognitive complexity * fix merge * fix merge conflikt * fix merge conflict * S allius/issue182 (#183) * GEN3: After inverter firmware update the 'Unknown Msg Type' increases continuously Fixes #182 * add support for Controller serial no and MAC * test hardening * GEN3: add support for new messages of version 3 firmwares * bump libraries to latest versions - bump aiomqtt to version 2.3.0 - bump aiohttp to version 3.10.5 * improve test coverage * reduce cognective complexity * fix target preview * remove dubbled fixtures * increase test coverage * Update README.md (#185) update badges * S allius/issue186 (#187) * Parse more values in Server Mode Fixes #186 * read OUTPUT_COEFFICIENT and MAC_ADDR in SrvMode * fix unit test * increase test coverage * S allius/issue186 (#188) * increase test coverage * update changelog * add dokumentation * change default config * Update README.md (#189) Config file is now foldable * GEN3: Invalid Contact Info Msg (#192) Fixes #191 * Refactoring async stream (#194) * GEN3: Invalid Contact Info Msg Fixes #191 * introduce ifc with FIFOs * add object factory * use AsyncIfc class with FIFO * declare more methods as classmethods * - refactoring - remove _forward_buffer - make async_write private * remove _forward_buffer * refactoring * avoid mqtt handling for invalid serial numbers * add two more callbacks * FIX update_header_cb handling * split AsyncStream in two classes * split ConnectionG3(P) in server and client class * update class diagramm * refactor server creation * remove duplicated imports * reduce code duplication * move StremPtr instances into Inverter class * resolution of connection classes - remove ConnectionG3Client - remove ConnectionG3Server - remove ConnectionG3PClient - remove ConnectionG3PServer * fix server connections * fix client loop closing * don't overwrite self.remote in constructor * update class diagramm * fixes - fixes null pointer accesses - initalize AsyncStreamClient with proper StreamPtr instance * add close callback * refactor close handling * remove connection classes * move more code into InverterBase class * remove test_inverter_base.py * add abstract inverter interface class * initial commit * fix sonar qube warnings * rename class Inverter into Proxy * fix typo * move class InverterIfc into a separate file * add more testcases * use ProtocolIfc class * add unit tests for AsyncStream class * icrease test coverage * reduce cognitive complexity * increase test coverage * increase tes coverage * simplify heartbeat handler * remove obsolete tx_get method * add more unittests * update changelog * remove __del__ method for proper gc runs * check releasing of ModbusConn instances * call garbage collector to release unreachable objs * decrease ref counter after the with block * S allius/issue196 (#198) * fix healthcheck - on infrastructure with IPv6 support localhost might be resolved to an IPv6 adress. Since the proxy only support IPv4 for now, we replace localhost by 127.0.0.1, to fix this * merge from main
This commit is contained in:
@@ -5,9 +5,11 @@ import asyncio
|
||||
if __name__ == "app.src.modbus_tcp":
|
||||
from app.src.config import Config
|
||||
from app.src.gen3plus.inverter_g3p import InverterG3P
|
||||
from app.src.infos import Infos
|
||||
else: # pragma: no cover
|
||||
from config import Config
|
||||
from gen3plus.inverter_g3p import InverterG3P
|
||||
from infos import Infos
|
||||
|
||||
logger = logging.getLogger('conn')
|
||||
|
||||
@@ -17,23 +19,26 @@ class ModbusConn():
|
||||
self.host = host
|
||||
self.port = port
|
||||
self.addr = (host, port)
|
||||
self.stream = None
|
||||
self.inverter = None
|
||||
|
||||
async def __aenter__(self) -> 'InverterG3P':
|
||||
'''Establish a client connection to the TSUN cloud'''
|
||||
connection = asyncio.open_connection(self.host, self.port)
|
||||
reader, writer = await connection
|
||||
self.stream = InverterG3P(reader, writer, self.addr,
|
||||
client_mode=True)
|
||||
logging.info(f'[{self.stream.node_id}:{self.stream.conn_no}] '
|
||||
self.inverter = InverterG3P(reader, writer,
|
||||
client_mode=True)
|
||||
self.inverter.__enter__()
|
||||
stream = self.inverter.local.stream
|
||||
logging.info(f'[{stream.node_id}:{stream.conn_no}] '
|
||||
f'Connected to {self.addr}')
|
||||
self.stream.inc_counter('Inverter_Cnt')
|
||||
await self.stream.publish_outstanding_mqtt()
|
||||
return self.stream
|
||||
Infos.inc_counter('Inverter_Cnt')
|
||||
await self.inverter.local.ifc.publish_outstanding_mqtt()
|
||||
return self.inverter
|
||||
|
||||
async def __aexit__(self, exc_type, exc, tb):
|
||||
self.stream.dec_counter('Inverter_Cnt')
|
||||
await self.stream.publish_outstanding_mqtt()
|
||||
Infos.dec_counter('Inverter_Cnt')
|
||||
await self.inverter.local.ifc.publish_outstanding_mqtt()
|
||||
self.inverter.__exit__(exc_type, exc, tb)
|
||||
|
||||
|
||||
class ModbusTcp():
|
||||
@@ -58,20 +63,22 @@ class ModbusTcp():
|
||||
'''Loop for receiving messages from the TSUN cloud (client-side)'''
|
||||
while True:
|
||||
try:
|
||||
async with ModbusConn(host, port) as stream:
|
||||
async with ModbusConn(host, port) as inverter:
|
||||
stream = inverter.local.stream
|
||||
await stream.send_start_cmd(snr, host)
|
||||
await stream.loop()
|
||||
await stream.ifc.loop()
|
||||
logger.info(f'[{stream.node_id}:{stream.conn_no}] '
|
||||
f'Connection closed - Shutdown: '
|
||||
f'{stream.shutdown_started}')
|
||||
if stream.shutdown_started:
|
||||
return
|
||||
del inverter # decrease ref counter after the with block
|
||||
|
||||
except (ConnectionRefusedError, TimeoutError) as error:
|
||||
logging.debug(f'Inv-conn:{error}')
|
||||
|
||||
except OSError as error:
|
||||
if error.errno == 113:
|
||||
if error.errno == 113: # pragma: no cover
|
||||
logging.debug(f'os-error:{error}')
|
||||
else:
|
||||
logging.info(f'os-error: {error}')
|
||||
|
||||
Reference in New Issue
Block a user