calculate power values for DCU (#303)
* calculate power values for DCU * refactor code
This commit is contained in:
@@ -5,6 +5,21 @@ from itertools import chain
|
||||
from infos import Infos, Register, ProxyMode, Fmt
|
||||
|
||||
|
||||
class RegisterFunc:
|
||||
@staticmethod
|
||||
def prod_sum(info: Infos, arr: dict) -> None | int:
|
||||
result = 0
|
||||
for sum in arr:
|
||||
prod = 1
|
||||
for factor in sum:
|
||||
val = info.get_db_value(factor)
|
||||
if val is None:
|
||||
return None
|
||||
prod = prod * val
|
||||
result += prod
|
||||
return result
|
||||
|
||||
|
||||
class RegisterMap:
|
||||
# make the class read/only by using __slots__
|
||||
__slots__ = ()
|
||||
@@ -121,11 +136,11 @@ class RegisterMap:
|
||||
0x42010034: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 voltage
|
||||
0x42010036: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 current
|
||||
0x42010038: {'reg': Register.BATT_38, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201003a: {'reg': Register.BATT_3a, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201003c: {'reg': Register.BATT_3c, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201003e: {'reg': Register.BATT_3e, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010040: {'reg': Register.BATT_40, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x42010042: {'reg': Register.BATT_42, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x4201003a: {'reg': Register.BATT_3a, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x4201003c: {'reg': Register.BATT_STATUS_1, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201003e: {'reg': Register.BATT_STATUS_2, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010040: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x42010042: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x42010044: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
|
||||
0x42010046: {'reg': Register.BATT_46, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010048: {'reg': Register.BATT_48, 'fmt': '!h'}, # noqa: E501
|
||||
@@ -136,13 +151,22 @@ class RegisterMap:
|
||||
0x42010066: {'reg': Register.BATT_66, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010068: {'reg': Register.BATT_68, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201006a: {'reg': Register.BATT_6a, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201006c: {'reg': Register.BATT_6c, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201006e: {'reg': Register.BATT_6e, 'fmt': '!h'}, # noqa: E501
|
||||
0x4201006c: {'reg': Register.BATT_OUT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x4201006e: {'reg': Register.BATT_OUT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x42010070: {'reg': Register.BATT_70, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010072: {'reg': Register.BATT_72, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010074: {'reg': Register.BATT_74, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010076: {'reg': Register.BATT_76, 'fmt': '!h'}, # noqa: E501
|
||||
0x42010078: {'reg': Register.BATT_78, 'fmt': '!h'}, # noqa: E501
|
||||
'calc': {
|
||||
1: {'reg': Register.BATT_PV_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
|
||||
'params': [[Register.BATT_PV1_VOLT, Register.BATT_PV1_CUR],
|
||||
[Register.BATT_PV2_VOLT, Register.BATT_PV2_CUR]]},
|
||||
2: {'reg': Register.BATT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
|
||||
'params': [[Register.BATT_VOLT, Register.BATT_CUR]]},
|
||||
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
|
||||
'params': [[Register.BATT_OUT_VOLT, Register.BATT_OUT_CUR]]},
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
@@ -191,13 +215,20 @@ class InfosG3P(Infos):
|
||||
# iterate over RegisterMap.map and get the register values
|
||||
sensor = self.get_db_value(Register.SENSOR_LIST)
|
||||
if "3026" == sensor:
|
||||
items = RegisterMap.map_3026.items()
|
||||
reg_map = RegisterMap.map_3026
|
||||
elif "02b0" == sensor:
|
||||
items = RegisterMap.map_02b0.items()
|
||||
reg_map = RegisterMap.map_02b0
|
||||
else:
|
||||
items = {}
|
||||
reg_map = {}
|
||||
items = reg_map.items()
|
||||
if 'calc' in reg_map:
|
||||
virt = reg_map['calc'].items()
|
||||
else:
|
||||
virt = {}
|
||||
|
||||
for _, row in chain(RegisterMap.map.items(), items):
|
||||
for idx, row in chain(RegisterMap.map.items(), items, virt):
|
||||
if 'calc' == idx:
|
||||
continue
|
||||
info_id = row['reg']
|
||||
if self.__hide_topic(row):
|
||||
res = self.ha_remove(info_id, node_id, snr) # noqa: E501
|
||||
@@ -213,7 +244,10 @@ class InfosG3P(Infos):
|
||||
stores the values in Infos.db
|
||||
|
||||
buf: buffer of the sequence to parse'''
|
||||
for idx, row in RegisterSel.get(sensor).items():
|
||||
reg_map = RegisterSel.get(sensor)
|
||||
for idx, row in reg_map.items():
|
||||
if 'calc' == idx:
|
||||
continue
|
||||
addr = idx & 0xffff
|
||||
ftype = (idx >> 16) & 0xff
|
||||
mtype = (idx >> 24) & 0xff
|
||||
@@ -223,16 +257,19 @@ class InfosG3P(Infos):
|
||||
continue
|
||||
info_id = row['reg']
|
||||
result = Fmt.get_value(buf, addr, row)
|
||||
yield from self.__update_val(node_id, info_id, result)
|
||||
|
||||
keys, level, unit, must_incr = self._key_obj(info_id)
|
||||
|
||||
if keys:
|
||||
name, update = self.update_db(keys, must_incr, result)
|
||||
yield keys[0], update
|
||||
else:
|
||||
name = str(f'info-id.0x{addr:x}')
|
||||
update = False
|
||||
if 'calc' in reg_map:
|
||||
for row in reg_map['calc'].values():
|
||||
info_id = row['reg']
|
||||
result = row['func'](self, row['params'])
|
||||
yield from self.__update_val(node_id, info_id, result)
|
||||
|
||||
def __update_val(self, node_id, info_id, result):
|
||||
keys, level, unit, must_incr = self._key_obj(info_id)
|
||||
if keys:
|
||||
name, update = self.update_db(keys, must_incr, result)
|
||||
yield keys[0], update
|
||||
if update:
|
||||
self.tracer.log(level, f'[{node_id}] GEN3PLUS: {name}'
|
||||
f' : {result}{unit}')
|
||||
|
||||
@@ -127,10 +127,10 @@ class Register(Enum):
|
||||
BATT_PV2_CUR = 1003
|
||||
BATT_38 = 1004
|
||||
BATT_3a = 1005
|
||||
BATT_3c = 1006
|
||||
BATT_3e = 1007
|
||||
BATT_40 = 1010
|
||||
BATT_42 = 1011
|
||||
BATT_STATUS_1 = 1006
|
||||
BATT_STATUS_2 = 1007
|
||||
BATT_VOLT = 1010
|
||||
BATT_CUR = 1011
|
||||
BATT_SOC = 1012
|
||||
BATT_46 = 1013
|
||||
BATT_48 = 1014
|
||||
@@ -140,13 +140,17 @@ class Register(Enum):
|
||||
BATT_66 = 1018
|
||||
BATT_68 = 1019
|
||||
BATT_6a = 1020
|
||||
BATT_6c = 1021
|
||||
BATT_6e = 1022
|
||||
BATT_OUT_VOLT = 1021
|
||||
BATT_OUT_CUR = 1022
|
||||
BATT_70 = 1023
|
||||
BATT_72 = 1024
|
||||
BATT_74 = 1025
|
||||
BATT_76 = 1026
|
||||
BATT_78 = 1027
|
||||
BATT_PV_PWR = 1040
|
||||
BATT_PWR = 1041
|
||||
BATT_OUT_PWR = 1042
|
||||
|
||||
VALUE_1 = 9000
|
||||
TEST_REG1 = 10000
|
||||
TEST_REG2 = 10001
|
||||
@@ -157,7 +161,10 @@ class Fmt:
|
||||
def get_value(buf: bytes, idx: int, row: dict):
|
||||
'''Get a value from buf and interpret as in row defined'''
|
||||
fmt = row['fmt']
|
||||
res = struct.unpack_from(fmt, buf, idx)
|
||||
try:
|
||||
res = struct.unpack_from(fmt, buf, idx)
|
||||
except Exception:
|
||||
return None
|
||||
result = res[0]
|
||||
if isinstance(result, (bytearray, bytes)):
|
||||
result = result.decode().split('\x00')[0]
|
||||
@@ -572,12 +579,12 @@ class Infos:
|
||||
Register.BATT_PV2_VOLT: {'name': ['batterie', 'pv2', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV2_CUR: {'name': ['batterie', 'pv2', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_38: {'name': ['batterie', 'Reg_38'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_38_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_3a: {'name': ['batterie', 'Reg_3a'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_3a_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_3c: {'name': ['batterie', 'Reg_3c'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_3c_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_3e: {'name': ['batterie', 'Reg_3e'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_3e_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_40: {'name': ['batterie', 'Reg_40'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_40_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_42: {'name': ['batterie', 'Reg_42'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_42_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_SOC: {'name': ['batterie', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'fmt': FMT_FLOAT, 'name': 'State of Charge', 'icon': 'mdi:battery-90'}}, # noqa: E501
|
||||
Register.BATT_3a: {'name': ['batterie', 'Reg_3a'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_3a_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_STATUS_1: {'name': ['batterie', 'Status_1'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_STATUS_2: {'name': ['batterie', 'Status_2'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_VOLT: {'name': ['batterie', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_bat_', 'fmt': FMT_FLOAT, 'name': 'Bat Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_CUR: {'name': ['batterie', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_bat_', 'fmt': FMT_FLOAT, 'name': 'Bat Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_SOC: {'name': ['batterie', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'fmt': FMT_FLOAT, 'name': 'State of Charge (SOC)', 'icon': 'mdi:battery-90'}}, # noqa: E501
|
||||
# Register.BATT_46: {'name': ['batterie', 'Reg_46'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_46_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
# Register.BATT_48: {'name': ['batterie', 'Reg_48'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_48_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
# Register.BATT_4a: {'name': ['batterie', 'Reg_4a'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_4a_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
@@ -587,13 +594,16 @@ class Infos:
|
||||
Register.BATT_66: {'name': ['batterie', 'Reg_66'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_66_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_68: {'name': ['batterie', 'Reg_68'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_68_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_6a: {'name': ['batterie', 'Reg_6a'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_6a_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_6c: {'name': ['batterie', 'Reg_6c'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_6c_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_6e: {'name': ['batterie', 'Reg_6e'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_6e_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_OUT_VOLT: {'name': ['batterie', 'out', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'val_tpl': "{{ (value_json['out']['Voltage'] | float)}}", 'name': 'Out Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_OUT_CUR: {'name': ['batterie', 'out', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'val_tpl': "{{ (value_json['out']['Current'] | float)}}", 'name': 'Out Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_70: {'name': ['batterie', 'Reg_70'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_70_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_72: {'name': ['batterie', 'Reg_72'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_72_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_74: {'name': ['batterie', 'Reg_74'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_74_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_76: {'name': ['batterie', 'Reg_76'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_76_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_78: {'name': ['batterie', 'Reg_78'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_78_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV_PWR: {'name': ['batterie', 'PV_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'pv_power_', 'fmt': FMT_INT, 'name': 'PV Power'}}, # noqa: E501
|
||||
Register.BATT_PWR: {'name': ['batterie', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_', 'fmt': FMT_INT, 'name': 'Batterie Power'}}, # noqa: E501
|
||||
Register.BATT_OUT_PWR: {'name': ['batterie', 'out', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'val_tpl': "{{ (value_json['out']['Power'] | int)}}", 'name': 'Out Power'}}, # noqa: E501
|
||||
}
|
||||
|
||||
@property
|
||||
|
||||
Reference in New Issue
Block a user