S allius/issue206 (#213)
* update changelog * add addon-dev target * initial version * use prebuild docker image * initial version for multi arch images * fix missing label latest * create log and config folder first. * clean up and translate to english * set labels with docker bake * add addon-debug and addon-dev targets * pass version number to proxy at runtime * add two more callbacks * get addon version from app * deploy rc addon container to ghcr * move ha_addon test into subdir * fix crash on container restart - mkdir -p returns no error even if the director exists * prepation for unit testing - move script into a method * added further config to schema * typo fixed * added monitor_sn + PV-strings 3-6 to create toml * added options.json for testing * prepare pytest and coverage for addons * fix missing values in resulting config.toml - define mqtt default values - convert filter configuration * first running unittest for addons * add ha_addons * increase test coverage * test empty options.json file for HA AddOn * fix pytest call in terminal * improve test coverage * remove uneeded options.json * move config.py into subdir cnf --------- Co-authored-by: Michael Metz <michael.metz@siemens.com>
This commit is contained in:
85
ha_addons/ha_addon/translations/en.yaml
Executable file
85
ha_addons/ha_addon/translations/en.yaml
Executable file
@@ -0,0 +1,85 @@
|
||||
---
|
||||
configuration:
|
||||
inverters:
|
||||
name: Inverters
|
||||
description: >+
|
||||
For each GEN3 inverter, the serial number of the inverter must be mapped to an MQTT
|
||||
definition. To do this, the corresponding configuration block is started with
|
||||
<16-digit serial number> so that all subsequent parameters are assigned
|
||||
to this inverter. Further inverter-specific parameters (e.g. polling mode) can be set
|
||||
in the configuration block
|
||||
|
||||
The serial numbers of all GEN3 inverters start with `R17`!
|
||||
|
||||
monitor_sn # The GEN3PLUS "Monitoring SN:"
|
||||
node_id # MQTT replacement for inverters serial number
|
||||
suggested_area # suggested installation area for home-assistant
|
||||
modbus_polling # Disable optional MODBUS polling
|
||||
pv1 # Optional, PV module descr
|
||||
pv2 # Optional, PV module descr
|
||||
|
||||
tsun.enabled:
|
||||
name: Connection to TSUN Cloud - for GEN3 inverter only
|
||||
description: >-
|
||||
switch on/off connection to the TSUN cloud
|
||||
This connection is only required if you want send data to the TSUN cloud
|
||||
eg. to use the TSUN APPs or receive firmware updates.
|
||||
|
||||
on - normal proxy operation
|
||||
off - The Inverter become isolated from Internet
|
||||
solarman.enabled:
|
||||
name: Connection to Solarman Cloud - for GEN3PLUS inverter only
|
||||
description: >-
|
||||
switch on/off connection to the Solarman cloud
|
||||
This connection is only required if you want send data to the Solarman cloud
|
||||
eg. to use the Solarman APPs or receive firmware updates.
|
||||
|
||||
on - normal proxy operation
|
||||
off - The Inverter become isolated from Internet
|
||||
inverters.allow_all:
|
||||
name: Allow all connections from all inverters
|
||||
description: >-
|
||||
The proxy only usually accepts connections from known inverters.
|
||||
Switch on for test purposes and unknown serial numbers.
|
||||
mqtt.host:
|
||||
name: MQTT Broker Host
|
||||
description: >-
|
||||
Hostname or IP address of the MQTT broker. if not set, the addon will try to connect to the Home Assistant MQTT broker
|
||||
mqtt.port:
|
||||
name: MQTT Broker Port
|
||||
description: >-
|
||||
Port of the MQTT broker. if not set, the addon will try to connect to the Home Assistant MQTT broker
|
||||
mqtt.user:
|
||||
name: MQTT Broker User
|
||||
description: >-
|
||||
User for the MQTT broker. if not set, the addon will try to connect to the Home Assistant MQTT broker
|
||||
mqtt.passwd:
|
||||
name: MQTT Broker Password
|
||||
description: >-
|
||||
Password for the MQTT broker. if not set, the addon will try to connect to the Home Assistant MQTT broker
|
||||
ha.auto_conf_prefix:
|
||||
name: MQTT prefix for subscribing for homeassistant status updates
|
||||
ha.discovery_prefix:
|
||||
name: MQTT prefix for discovery topic
|
||||
ha.entity_prefix:
|
||||
name: MQTT topic prefix for publishing inverter values
|
||||
ha.proxy_node_id:
|
||||
name: MQTT node id, for the proxy_node_id
|
||||
ha.proxy_unique_id:
|
||||
name: MQTT unique id, to identify a proxy instance
|
||||
tsun.host:
|
||||
name: TSUN Cloud Host
|
||||
description: >-
|
||||
Hostname or IP address of the TSUN cloud. if not set, the addon will try to connect to the cloud default
|
||||
on logger.talent-monitoring.com
|
||||
solarman.host:
|
||||
name: Solarman Cloud Host
|
||||
description: >-
|
||||
Hostname or IP address of the Solarman cloud. if not set, the addon will try to connect to the cloud default
|
||||
on iot.talent-monitoring.com
|
||||
|
||||
|
||||
network:
|
||||
8127/tcp: x...
|
||||
5005/tcp: listening Port for TSUN GEN3 Devices
|
||||
10000/tcp: listening Port for TSUN GEN3PLUS Devices
|
||||
Reference in New Issue
Block a user