Dev 0.10 (#151)
* S allius/issue117 (#118) * add shutdown flag * add more register definitions * add start commando for client side connections * add first support for port 8899 * fix shutdown * add client_mode configuration * read client_mode config to setup inverter connections * add client_mode connections over port 8899 * add preview build * Update README.md describe the new client-mode over port 8899 for GEN3PLUS * MODBUS: the last digit of the inverter version is a hexadecimal number (#121) * S allius/issue117 (#122) * add shutdown flag * add more register definitions * add start commando for client side connections * add first support for port 8899 * fix shutdown * add client_mode configuration * read client_mode config to setup inverter connections * add client_mode connections over port 8899 * add preview build * add documentation for client_mode * catch os error and log thme with DEBUG level * update changelog * make the maximum output coefficient configurable (#124) * S allius/issue120 (#126) * add config option to disable the modbus polling * read more modbus regs in polling mode * extend connection timeouts if polling mode is disabled * update changelog * S allius/issue125 (#127) * fix linter warning * move sequence diagramm to wiki * catch asyncio.CancelledError * S allius/issue128 (#130) * set Register.NO_INPUTS fix to 4 for GEN3PLUS * don't set Register.NO_INPUTS per MODBUS * fix unit tests * register OUTPUT_COEFFICIENT at HA * update changelog * - Home Assistant: improve inverter status value texts * - GEN3: add inverter status * on closing send outstanding MQTT data to the broker * force MQTT publish on every conn open and close * reset inverter state on close - workaround which reset the inverter status to offline when the inverter has a very low output power on connection close * improve client modified - reduce the polling cadence to 30s - set controller statistics for HA * client mode set controller IP for HA * S allius/issue131 (#132) * Make __publish_outstanding_mqtt public * update proxy counter - on client mode connection establishment or disconnecting update tje counection counter * Update README.md (#133) * reset inverter state on close - workaround which reset the inverter status to offline when the inverter has a very low output power on connection close * S allius/issue134 (#135) * add polling invertval and method ha_remove() * add client_mode arg to constructors - add PollingInvervall * hide some topics in client mode - we hide topics in HA by sending an empty register MQTT topic during HA auto configuration * add client_mode value * update class diagram * fix modbus close handler - fix empty call and cleanup que - add unit test * don't sent an initial 1710 msg in client mode * change HA icon for inverter status * increase test coverage * accelerate timer tests * bump aiomqtt and schema to latest release (#137) * MQTT timestamps and protocol improvements (#140) * add TS_INPUT, TS_GRID and TS_TOTAL * prepare MQTT timestamps - add _set_mqtt_timestamp method - fix hexdump printing * push dev and debug images to docker.io * add unix epoche timestamp for MQTT pakets * set timezone for unit tests * set name für setting timezone step * trigger new action * GEN3 and GEN3PLUS: handle multiple message - read: iterate over the receive buffer - forward: append messages to the forward buffer - _update_header: iterate over the forward buffer * GEN3: optimize timeout handling - longer timeout in state init and reveived - got to state pending only from state up * update changelog * cleanup * print coloured logs * Create sonarcloud.yml (#143) * Update sonarcloud.yml * Update sonarcloud.yml * Update sonarcloud.yml * Update sonarcloud.yml * Update sonarcloud.yml * build multi arch images with sboms (#146) * don't send MODBUS request when state is not up (#147) * adapt timings * don't send MODBUS request when state is note up * adapt unit test * make test code more clean (#148) * Make test code more clean (#149) * cleanup * Code coverage for SonarCloud (#150) * cleanup code and unit tests * add test coverage for SonarCloud * configure SonarCloud * update changelog * Do no build on *.yml changes * prepare release 0.10.0 * disable MODBUS_POLLING for GEN§PLUS in example config * bump aiohttp to version 3.10.2 * code cleanup * Fetch all history for all tags and branches
This commit is contained in:
@@ -31,12 +31,14 @@ inverters.allow_all = true # allow inverters, even if we have no inverter mapp
|
||||
[inverters."R170000000000001"]
|
||||
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
||||
#suggested_area = '' # Optional, suggested installation area for home-assistant
|
||||
modbus_polling = false # Disable optional MODBUS polling
|
||||
#pv1 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv2 = {type = 'RSM40-8-395M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
#[inverters."R17xxxxxxxxxxxx2"]
|
||||
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
||||
#suggested_area = '' # Optional, suggested installation area for home-assistant
|
||||
#modbus_polling = false # Disable optional MODBUS polling
|
||||
#pv1 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv2 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
@@ -44,6 +46,12 @@ inverters.allow_all = true # allow inverters, even if we have no inverter mapp
|
||||
monitor_sn = 2000000000 # The "Monitoring SN:" can be found on a sticker enclosed with the inverter
|
||||
#node_id = '' # Optional, MQTT replacement for inverters serial number
|
||||
#suggested_area = '' # Optional, suggested installation place for home-assistant
|
||||
modbus_polling = true # Enable optional MODBUS polling
|
||||
|
||||
# if your inverter supports SSL connections you must use the client_mode. Pls, uncomment
|
||||
# the next line and configure the fixed IP of your inverter
|
||||
#client_mode = {host = '192.168.0.1', port = 8899}
|
||||
|
||||
#pv1 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
#pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
Reference in New Issue
Block a user