add alarm bitfields (#352)
- fix bitfield of the inverter alarms - add batterie alarms
This commit is contained in:
@@ -43,8 +43,8 @@ class Modbus():
|
||||
0x000a: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 voltage
|
||||
0x000b: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, PV2 current
|
||||
0x000c: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
|
||||
0x000e: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x000f: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x000e: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x000f: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x0010: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x0011: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x0012: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
|
||||
@@ -71,7 +71,7 @@ class Modbus():
|
||||
0x0027: {'reg': Register.BATT_OUT_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
|
||||
0x0028: {'reg': Register.BATT_OUT_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x0029: {'reg': Register.BATT_TEMP_4, 'fmt': '!h'}, # noqa: E501
|
||||
0x002a: {'reg': Register.BATT_74, 'fmt': '!h'}, # noqa: E501
|
||||
0x002a: {'reg': Register.BATT_ALARM, 'fmt': '!h'}, # noqa: E501
|
||||
0x002b: {'reg': Register.BATT_HW_VERS, 'fmt': '!h'}, # noqa: E501
|
||||
0x002c: {'reg': Register.BATT_SW_VERS, 'fmt': '!h'}, # noqa: E501
|
||||
|
||||
|
||||
Reference in New Issue