experimental modbus scan
This commit is contained in:
@@ -55,9 +55,9 @@ class SolarmanV5(Message):
|
||||
MB_RTU_CMD = 2
|
||||
MB_START_TIMEOUT = 40
|
||||
'''start delay for Modbus polling in server mode'''
|
||||
MB_REGULAR_TIMEOUT = 60
|
||||
MB_REGULAR_TIMEOUT = 20
|
||||
'''regular Modbus polling time in server mode'''
|
||||
MB_CLIENT_DATA_UP = 30
|
||||
MB_CLIENT_DATA_UP = 10
|
||||
'''Data up time in client mode'''
|
||||
HDR_FMT = '<BLLL'
|
||||
'''format string for packing of the header'''
|
||||
@@ -142,6 +142,8 @@ class SolarmanV5(Message):
|
||||
'''timer value for next Modbus polling request'''
|
||||
self.modbus_polling = False
|
||||
self.sensor_list = 0x0000
|
||||
self.mb_start_reg = 0x5981
|
||||
self.mb_inv_no = 1
|
||||
|
||||
'''
|
||||
Our puplic methods
|
||||
@@ -180,7 +182,21 @@ class SolarmanV5(Message):
|
||||
self.new_data['controller'] = True
|
||||
|
||||
self.state = State.up
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.DEBUG)
|
||||
# self.__build_header(0x1710)
|
||||
# self.ifc.write += struct.pack('<B', 0)
|
||||
# self.__finish_send_msg()
|
||||
# hex_dump_memory(logging.INFO, f'Send StartCmd:{self.addr}:',
|
||||
# self.ifc.write, len(self.ifc.write))
|
||||
# self.writer.write(self.ifc.write)
|
||||
# self.ifc.write = bytearray(0) # self.ifc.write[sent:]
|
||||
|
||||
if self.sensor_list != 0x02b0:
|
||||
self._send_modbus_cmd(self.mb_inv_no, Modbus.READ_REGS,
|
||||
self.mb_start_reg, 4, logging.INFO)
|
||||
else:
|
||||
self._send_modbus_cmd(Modbus.INV_ADDR, Modbus.READ_REGS, 0x3000,
|
||||
48, logging.DEBUG)
|
||||
|
||||
self.mb_timer.start(self.mb_timeout)
|
||||
|
||||
def new_state_up(self):
|
||||
@@ -423,24 +439,38 @@ class SolarmanV5(Message):
|
||||
self.ifc.write.logging(log_lvl, f'Send Modbus {state}:{self.addr}:')
|
||||
self.ifc.write()
|
||||
|
||||
def _send_modbus_cmd(self, func, addr, val, log_lvl) -> None:
|
||||
def _send_modbus_cmd(self, mb_no, func, addr, val, log_lvl) -> None:
|
||||
if self.state != State.up:
|
||||
logger.log(log_lvl, f'[{self.node_id}] ignore MODBUS cmd,'
|
||||
' as the state is not UP')
|
||||
return
|
||||
self.mb.build_msg(Modbus.INV_ADDR, func, addr, val, log_lvl)
|
||||
self.mb.build_msg(mb_no, func, addr, val, log_lvl)
|
||||
|
||||
async def send_modbus_cmd(self, func, addr, val, log_lvl) -> None:
|
||||
self._send_modbus_cmd(func, addr, val, log_lvl)
|
||||
self._send_modbus_cmd(Modbus.INV_ADDR, func, addr, val, log_lvl)
|
||||
|
||||
def mb_timout_cb(self, exp_cnt):
|
||||
self.mb_timer.start(self.mb_timeout)
|
||||
if self.sensor_list != 0x2b0:
|
||||
self.mb_start_reg += 4
|
||||
if self.mb_start_reg > 0xffff:
|
||||
self.mb_start_reg = self.mb_start_reg & 0xffff
|
||||
self.mb_inv_no += 1
|
||||
logging.info(f"Next Round: inv:{self.mb_inv_no}"
|
||||
f" reg:{self.mb_start_reg:04x}")
|
||||
if (self.mb_start_reg & 0xfffc) % 0x80 == 0:
|
||||
logging.info(f"Scan info: inv:{self.mb_inv_no}"
|
||||
f" reg:{self.mb_start_reg:04x}")
|
||||
self._send_modbus_cmd(self.mb_inv_no, Modbus.READ_REGS,
|
||||
self.mb_start_reg, 4, logging.INFO)
|
||||
else:
|
||||
self._send_modbus_cmd(Modbus.INV_ADDR, Modbus.READ_REGS, 0x3000,
|
||||
48, logging.DEBUG)
|
||||
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.DEBUG)
|
||||
|
||||
if 1 == (exp_cnt % 30):
|
||||
# logging.info("Regular Modbus Status request")
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.DEBUG)
|
||||
if 1 == (exp_cnt % 30):
|
||||
# logging.info("Regular Modbus Status request")
|
||||
self._send_modbus_cmd(Modbus.INV_ADDR, Modbus.READ_REGS,
|
||||
0x2000, 96, logging.DEBUG)
|
||||
|
||||
def at_cmd_forbidden(self, cmd: str, connection: str) -> bool:
|
||||
return not cmd.startswith(tuple(self.at_acl[connection]['allow'])) or \
|
||||
@@ -641,6 +671,13 @@ class SolarmanV5(Message):
|
||||
# logger.info(f'first byte modbus:{data[14]}')
|
||||
inv_update = False
|
||||
self.modbus_elms = 0
|
||||
if (self.sensor_list != 0x2b0 and data[15] != 0):
|
||||
logging.info('Valid MODBUS data '
|
||||
f'(reg: 0x{self.mb.last_reg:04x}):')
|
||||
hex_dump_memory(logging.INFO, 'Valid MODBUS data '
|
||||
f'(reg: 0x{self.mb.last_reg:04x}):',
|
||||
data[14:], modbus_msg_len)
|
||||
|
||||
for key, update, _ in self.mb.recv_resp(self.db, data[14:],
|
||||
self.node_id):
|
||||
self.modbus_elms += 1
|
||||
|
||||
@@ -87,8 +87,8 @@ class Modbus():
|
||||
'''Response handler to forward the response'''
|
||||
self.timeout = timeout
|
||||
'''MODBUS response timeout in seconds'''
|
||||
self.max_retries = 1
|
||||
'''Max retransmit for MODBUS requests'''
|
||||
self.max_retries = 0
|
||||
'''Max retransmit for MODBU requests'''
|
||||
self.retry_cnt = 0
|
||||
self.last_req = b''
|
||||
self.counter = {}
|
||||
|
||||
Reference in New Issue