## Features
|
||||
|
||||
- supports TSUN GEN3 PLUS inverters: TSOL-MS2000, MS1800 and MS1600
|
||||
- supports TSUN GEN3 inverters: TSOL-MS800, MS700, MS600, MS400, MS350 and MS300
|
||||
- Supports TSUN GEN3 PLUS inverters: TSOL-MS2000, MS1800 and MS1600
|
||||
- Supports TSUN GEN3 inverters: TSOL-MS800, MS700, MS600, MS400, MS350 and MS300
|
||||
- `MQTT` support
|
||||
- `Home-Assistant` auto-discovery support
|
||||
- `MODBUS` support via MQTT topics
|
||||
- `AT-Command` support via MQTT topics (GEN3PLUS only)
|
||||
- Faster DataUp interval sends measurement data to the MQTT broker every minute
|
||||
- Self-sufficient island operation without internet
|
||||
- runs in a non-root Docker Container
|
||||
- Security-Features:
|
||||
- control access via `AT-commands`
|
||||
- Runs in a non-root Docker Container
|
||||
|
||||
## Home Assistant Screenshots
|
||||
|
||||
@@ -156,7 +161,7 @@ suggested_area = 'balcony' # Optional, suggested installation area for home-a
|
||||
pv1 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
pv2 = {type = 'RSM40-8-405M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
[inverters."Y17xxxxxxxxxxxx1"]
|
||||
[inverters."Y17xxxxxxxxxxxx1"] # This block is also for inverters with a Y47 serial no
|
||||
monitor_sn = 2000000000 # The "Monitoring SN:" can be found on a sticker enclosed with the inverter
|
||||
node_id = 'inv_3' # MQTT replacement for inverters serial number
|
||||
suggested_area = 'garage' # suggested installation place for home-assistant
|
||||
@@ -165,6 +170,12 @@ pv2 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module de
|
||||
pv3 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
pv4 = {type = 'RSM40-8-410M', manufacturer = 'Risen'} # Optional, PV module descr
|
||||
|
||||
[gen3plus.at_acl]
|
||||
tsun.allow = ['AT+Z', 'AT+UPURL', 'AT+SUPDATE'] # allow this for TSUN access
|
||||
tsun.block = []
|
||||
mqtt.allow = ['AT+'] # allow all via mqtt
|
||||
mqtt.block = []
|
||||
|
||||
```
|
||||
|
||||
## Inverter Configuration
|
||||
@@ -230,7 +241,7 @@ Legend
|
||||
🚧: Proxy support in preparation
|
||||
```
|
||||
|
||||
❗The new inverters of the GEN3 Plus generation (e.g. MS-2000) use a completely different protocol for data transmission to the TSUN server. These inverters are supported from proxy version 0.6. The serial numbers of these inverters start with `Y17E` instead of `R17E`
|
||||
❗The new inverters of the GEN3 Plus generation (e.g. MS-2000) use a completely different protocol for data transmission to the TSUN server. These inverters are supported from proxy version 0.6. The serial numbers of these inverters start with `Y17E` or `Y47E` instead of `R17E`
|
||||
|
||||
If you have one of these combinations with a red question mark, it would be very nice if you could send me a proxy trace so that I can carry out the detailed checks and adjust the device and system tests. [Ask here how to send a trace](https://github.com/s-allius/tsun-gen3-proxy/discussions/categories/traces-for-compatibility-check)
|
||||
|
||||
|
||||