* make timestamp handling stateless

* adapt tests for stateless timestamp handling

* initial version

* add more type annotations

* add more type annotations

* fix Generator annotation for ha_proxy_confs

* fix names of issue branches

* add more type annotations

* don't use depricated varn anymore

* don't mark all test as async

* fix imports

* fix solarman unit tests

- fake Mqtt class

* print image build time during proxy start

* update changelog

* fix pytest collect warning

* cleanup msg_get_time handler

* addapt unit test

* label debug images with debug

* dump droped packages

* fix warnings

* add systemtest with invalid start byte

* update changelog

* update changelog

* add exposed ports and healthcheck

* add wget for healthcheck

* add aiohttp

* use config validation for healthcheck

* add http server for healthcheck

* calculate msg prossesing time

* add healthy check methods

* fix typo

* log ConfigErr with DEBUG level

* Update async_stream.py

- check if processing time is < 5 sec

* add a close handler to release internal resources

* call modbus close hanlder on a close call

* add exception handling for forward handler

* update changelog

* isolate Modbus fix

* cleanup

* update changelog

* add heaithy handler

* log unrelease references

* add healtcheck

* complete exposed port list

* add wget for healtcheck

* add aiohttp

* use Enum class for State

* calc processing time for healthcheck

* add HTTP server for healthcheck

* cleanup

* Update CHANGELOG.md

* updat changelog

* add docstrings to state enum

* set new state State.received

* add healthy method

* log healthcheck infos with DEBUG level

* update changelog

* S allius/issue100 (#101)

* detect dead connections

- disconnect connection on Msg receive timeout
- improve connection trace (add connection id)

* update changelog

* fix merge conflict

* fix unittests

* S allius/issue108 (#109)

* add more data types

* adapt unittests

* improve test coverage

* fix linter warning

* update changelog

* S allius/issue102 (#110)

* hotfix: don't send two MODBUS commands together

* fix unit tests

* remove read loop

* optional sleep between msg read and sending rsp

* wait after read 0.5s before sending a response

* add pending state

* fix state definitions

* determine the connection timeout by the conn state

* avoid sending MODBUS cmds in the inverter's reporting phase

* update changelog

* S allius/issue111 (#112)

Synchronize regular MODBUS commands with the status of the inverter to prevent the inverter from crashing due to unexpected packets.

* inital checkin

* remove crontab entry for regular MODBUS cmds

* add timer for regular MODBUS polling

* fix Stop method call for already stopped timer

* optimize MB_START_TIMEOUT value

* cleanup

* update changelog

* fix buildx warnings

* fix timer cleanup

* fix Config.class_init()

- return error string or None
- release Schema structure after building thr config

* add quit flag to docker push

* fix timout calculation

* rename python to debugpy

* add asyncio log

* cleanup shutdown
- stop webserver on shutdown
- enable asyncio debug mode for debug versions

* update changelog

* update changelog

* fix exception in MODBUS timeout callback

* update changelog
This commit is contained in:
Stefan Allius
2024-07-01 23:41:56 +02:00
committed by GitHub
parent f3e69ff217
commit a42ba8a8c6
31 changed files with 1047 additions and 253 deletions

View File

@@ -2,6 +2,8 @@ import logging
import asyncio
import signal
import os
from asyncio import StreamReader, StreamWriter
from aiohttp import web
from logging import config # noqa F401
from messages import Message
from inverter import Inverter
@@ -10,25 +12,83 @@ from gen3plus.inverter_g3p import InverterG3P
from scheduler import Schedule
from config import Config
routes = web.RouteTableDef()
proxy_is_up = False
async def handle_client(reader, writer):
@routes.get('/')
async def hello(request):
return web.Response(text="Hello, world")
@routes.get('/-/ready')
async def ready(request):
if proxy_is_up:
status = 200
text = 'Is ready'
else:
status = 503
text = 'Not ready'
return web.Response(status=status, text=text)
@routes.get('/-/healthy')
async def healthy(request):
if proxy_is_up:
# logging.info('web reqeust healthy()')
for stream in Message:
try:
res = stream.healthy()
if not res:
return web.Response(status=503, text="I have a problem")
except Exception as err:
logging.info(f'Exception:{err}')
return web.Response(status=200, text="I'm fine")
async def webserver(addr, port):
'''coro running our webserver'''
app = web.Application()
app.add_routes(routes)
runner = web.AppRunner(app)
await runner.setup()
site = web.TCPSite(runner, addr, port)
await site.start()
logging.info(f'HTTP server listen on port: {port}')
try:
# Normal interaction with aiohttp
while True:
await asyncio.sleep(3600) # sleep forever
except asyncio.CancelledError:
logging.info('HTTP server cancelled')
await runner.cleanup()
logging.debug('HTTP cleanup done')
async def handle_client(reader: StreamReader, writer: StreamWriter):
'''Handles a new incoming connection and starts an async loop'''
addr = writer.get_extra_info('peername')
await InverterG3(reader, writer, addr).server_loop(addr)
async def handle_client_v2(reader, writer):
async def handle_client_v2(reader: StreamReader, writer: StreamWriter):
'''Handles a new incoming connection and starts an async loop'''
addr = writer.get_extra_info('peername')
await InverterG3P(reader, writer, addr).server_loop(addr)
async def handle_shutdown(loop):
async def handle_shutdown(web_task):
'''Close all TCP connections and stop the event loop'''
logging.info('Shutdown due to SIGTERM')
global proxy_is_up
proxy_is_up = False
#
# first, disc all open TCP connections gracefully
@@ -38,7 +98,7 @@ async def handle_shutdown(loop):
await asyncio.wait_for(stream.disc(), 2)
except Exception:
pass
logging.info('Disconnecting done')
logging.info('Proxy disconnecting done')
#
# second, close all open TCP connections
@@ -46,12 +106,20 @@ async def handle_shutdown(loop):
for stream in Message:
stream.close()
#
# at last, we stop the loop
#
loop.stop()
await asyncio.sleep(0.1) # give time for closing
logging.info('Proxy closing done')
logging.info('Shutdown complete')
#
# third, cancel the web server
#
web_task.cancel()
await web_task
#
# at last, start a coro for stopping the loop
#
logging.debug("Stop event loop")
loop.stop()
def get_log_level() -> int:
@@ -84,17 +152,28 @@ if __name__ == "__main__":
logging.getLogger('conn').setLevel(log_level)
logging.getLogger('data').setLevel(log_level)
logging.getLogger('tracer').setLevel(log_level)
logging.getLogger('asyncio').setLevel(log_level)
# logging.getLogger('mqtt').setLevel(log_level)
# read config file
Config.class_init()
loop = asyncio.new_event_loop()
asyncio.set_event_loop(loop)
# read config file
ConfigErr = Config.class_init()
if ConfigErr is not None:
logging.info(f'ConfigErr: {ConfigErr}')
Inverter.class_init()
Schedule.start()
#
# Create tasks for our listening servers. These must be tasks! If we call
# start_server directly out of our main task, the eventloop will be blocked
# and we can't receive and handle the UNIX signals!
#
loop.create_task(asyncio.start_server(handle_client, '0.0.0.0', 5005))
loop.create_task(asyncio.start_server(handle_client_v2, '0.0.0.0', 10000))
web_task = loop.create_task(webserver('0.0.0.0', 8127))
#
# Register some UNIX Signal handler for a gracefully server shutdown
# on Docker restart and stop
@@ -102,22 +181,18 @@ if __name__ == "__main__":
for signame in ('SIGINT', 'SIGTERM'):
loop.add_signal_handler(getattr(signal, signame),
lambda loop=loop: asyncio.create_task(
handle_shutdown(loop)))
#
# Create taska for our listening servera. These must be tasks! If we call
# start_server directly out of our main task, the eventloop will be blocked
# and we can't receive and handle the UNIX signals!
#
loop.create_task(asyncio.start_server(handle_client, '0.0.0.0', 5005))
loop.create_task(asyncio.start_server(handle_client_v2, '0.0.0.0', 10000))
handle_shutdown(web_task)))
loop.set_debug(log_level == logging.DEBUG)
try:
if ConfigErr is None:
proxy_is_up = True
loop.run_forever()
except KeyboardInterrupt:
pass
finally:
logging.info("Event loop is stopped")
Inverter.class_close(loop)
logging.info('Close event loop')
logging.debug('Close event loop')
loop.close()
logging.info(f'Finally, exit Server "{serv_name}"')