Dev 0.9 (#115)
* make timestamp handling stateless * adapt tests for stateless timestamp handling * initial version * add more type annotations * add more type annotations * fix Generator annotation for ha_proxy_confs * fix names of issue branches * add more type annotations * don't use depricated varn anymore * don't mark all test as async * fix imports * fix solarman unit tests - fake Mqtt class * print image build time during proxy start * update changelog * fix pytest collect warning * cleanup msg_get_time handler * addapt unit test * label debug images with debug * dump droped packages * fix warnings * add systemtest with invalid start byte * update changelog * update changelog * add exposed ports and healthcheck * add wget for healthcheck * add aiohttp * use config validation for healthcheck * add http server for healthcheck * calculate msg prossesing time * add healthy check methods * fix typo * log ConfigErr with DEBUG level * Update async_stream.py - check if processing time is < 5 sec * add a close handler to release internal resources * call modbus close hanlder on a close call * add exception handling for forward handler * update changelog * isolate Modbus fix * cleanup * update changelog * add heaithy handler * log unrelease references * add healtcheck * complete exposed port list * add wget for healtcheck * add aiohttp * use Enum class for State * calc processing time for healthcheck * add HTTP server for healthcheck * cleanup * Update CHANGELOG.md * updat changelog * add docstrings to state enum * set new state State.received * add healthy method * log healthcheck infos with DEBUG level * update changelog * S allius/issue100 (#101) * detect dead connections - disconnect connection on Msg receive timeout - improve connection trace (add connection id) * update changelog * fix merge conflict * fix unittests * S allius/issue108 (#109) * add more data types * adapt unittests * improve test coverage * fix linter warning * update changelog * S allius/issue102 (#110) * hotfix: don't send two MODBUS commands together * fix unit tests * remove read loop * optional sleep between msg read and sending rsp * wait after read 0.5s before sending a response * add pending state * fix state definitions * determine the connection timeout by the conn state * avoid sending MODBUS cmds in the inverter's reporting phase * update changelog * S allius/issue111 (#112) Synchronize regular MODBUS commands with the status of the inverter to prevent the inverter from crashing due to unexpected packets. * inital checkin * remove crontab entry for regular MODBUS cmds * add timer for regular MODBUS polling * fix Stop method call for already stopped timer * optimize MB_START_TIMEOUT value * cleanup * update changelog * fix buildx warnings * fix timer cleanup * fix Config.class_init() - return error string or None - release Schema structure after building thr config * add quit flag to docker push * fix timout calculation * rename python to debugpy * add asyncio log * cleanup shutdown - stop webserver on shutdown - enable asyncio debug mode for debug versions * update changelog * update changelog * fix exception in MODBUS timeout callback * update changelog
This commit is contained in:
@@ -6,15 +6,17 @@ import asyncio
|
||||
from datetime import datetime
|
||||
|
||||
if __name__ == "app.src.gen3plus.solarman_v5":
|
||||
from app.src.messages import hex_dump_memory, Message
|
||||
from app.src.messages import hex_dump_memory, Message, State
|
||||
from app.src.modbus import Modbus
|
||||
from app.src.my_timer import Timer
|
||||
from app.src.config import Config
|
||||
from app.src.gen3plus.infos_g3p import InfosG3P
|
||||
from app.src.infos import Register
|
||||
else: # pragma: no cover
|
||||
from messages import hex_dump_memory, Message
|
||||
from messages import hex_dump_memory, Message, State
|
||||
from config import Config
|
||||
from modbus import Modbus
|
||||
from my_timer import Timer
|
||||
from gen3plus.infos_g3p import InfosG3P
|
||||
from infos import Register
|
||||
# import traceback
|
||||
@@ -51,6 +53,8 @@ class Sequence():
|
||||
class SolarmanV5(Message):
|
||||
AT_CMD = 1
|
||||
MB_RTU_CMD = 2
|
||||
MB_START_TIMEOUT = 40
|
||||
MB_REGULAR_TIMEOUT = 60
|
||||
|
||||
def __init__(self, server_side: bool):
|
||||
super().__init__(server_side, self.send_modbus_cb, mb_timeout=5)
|
||||
@@ -123,19 +127,20 @@ class SolarmanV5(Message):
|
||||
self.at_acl = g3p_cnf['at_acl']
|
||||
|
||||
self.node_id = 'G3P' # will be overwritten in __set_serial_no
|
||||
# self.forwarding = Config.get('solarman')['enabled']
|
||||
self.mb_timer = Timer(self.mb_timout_cb, self.node_id)
|
||||
|
||||
'''
|
||||
Our puplic methods
|
||||
'''
|
||||
def close(self) -> None:
|
||||
logging.debug('Solarman.close()')
|
||||
# we have refernces to methods of this class in self.switch
|
||||
# we have references to methods of this class in self.switch
|
||||
# so we have to erase self.switch, otherwise this instance can't be
|
||||
# deallocated by the garbage collector ==> we get a memory leak
|
||||
self.switch.clear()
|
||||
self.log_lvl.clear()
|
||||
self.state = self.STATE_CLOSED
|
||||
self.state = State.closed
|
||||
self.mb_timer.close()
|
||||
super().close()
|
||||
|
||||
def __set_serial_no(self, snr: int):
|
||||
@@ -169,7 +174,7 @@ class SolarmanV5(Message):
|
||||
|
||||
self.unique_id = serial_no
|
||||
|
||||
def read(self) -> None:
|
||||
def read(self) -> float:
|
||||
self._read()
|
||||
|
||||
if not self.header_valid:
|
||||
@@ -184,10 +189,13 @@ class SolarmanV5(Message):
|
||||
self._recv_buffer, self.header_len+self.data_len+2)
|
||||
if self.__trailer_is_ok(self._recv_buffer, self.header_len
|
||||
+ self.data_len + 2):
|
||||
if self.state == State.init:
|
||||
self.state = State.received
|
||||
|
||||
self.__set_serial_no(self.snr)
|
||||
self.__dispatch_msg()
|
||||
self.__flush_recv_msg()
|
||||
return
|
||||
return 0 # wait 0s before sending a response
|
||||
|
||||
def forward(self, buffer, buflen) -> None:
|
||||
tsun = Config.get('solarman')
|
||||
@@ -253,6 +261,10 @@ class SolarmanV5(Message):
|
||||
self.snr = result[4]
|
||||
|
||||
if start != 0xA5:
|
||||
hex_dump_memory(logging.ERROR,
|
||||
'Drop packet w invalid start byte from'
|
||||
f' {self.addr}:', buf, buf_len)
|
||||
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
# erase broken recv buffer
|
||||
self._recv_buffer = bytearray()
|
||||
@@ -264,6 +276,9 @@ class SolarmanV5(Message):
|
||||
crc = buf[self.data_len+11]
|
||||
stop = buf[self.data_len+12]
|
||||
if stop != 0x15:
|
||||
hex_dump_memory(logging.ERROR,
|
||||
'Drop packet w invalid stop byte from '
|
||||
f'{self.addr}:', buf, buf_len)
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
if len(self._recv_buffer) > (self.data_len+13):
|
||||
next_start = buf[self.data_len+13]
|
||||
@@ -338,9 +353,9 @@ class SolarmanV5(Message):
|
||||
self.__finish_send_msg()
|
||||
|
||||
def send_modbus_cb(self, pdu: bytearray, log_lvl: int, state: str):
|
||||
if self.state != self.STATE_UP:
|
||||
logger.warn(f'[{self.node_id}] ignore MODBUS cmd,'
|
||||
' cause the state is not UP anymore')
|
||||
if self.state != State.up:
|
||||
logger.warning(f'[{self.node_id}] ignore MODBUS cmd,'
|
||||
' cause the state is not UP anymore')
|
||||
return
|
||||
self.__build_header(0x4510)
|
||||
self._send_buffer += struct.pack('<BHLLL', self.MB_RTU_CMD,
|
||||
@@ -352,21 +367,33 @@ class SolarmanV5(Message):
|
||||
self.writer.write(self._send_buffer)
|
||||
self._send_buffer = bytearray(0) # self._send_buffer[sent:]
|
||||
|
||||
async def send_modbus_cmd(self, func, addr, val, log_lvl) -> None:
|
||||
if self.state != self.STATE_UP:
|
||||
def _send_modbus_cmd(self, func, addr, val, log_lvl) -> None:
|
||||
if self.state != State.up:
|
||||
logger.log(log_lvl, f'[{self.node_id}] ignore MODBUS cmd,'
|
||||
' as the state is not UP')
|
||||
return
|
||||
self.mb.build_msg(Modbus.INV_ADDR, func, addr, val, log_lvl)
|
||||
|
||||
async def send_modbus_cmd(self, func, addr, val, log_lvl) -> None:
|
||||
self._send_modbus_cmd(func, addr, val, log_lvl)
|
||||
|
||||
def mb_timout_cb(self, exp_cnt):
|
||||
self.mb_timer.start(self.MB_REGULAR_TIMEOUT)
|
||||
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x3008, 21, logging.DEBUG)
|
||||
|
||||
if 0 == (exp_cnt % 30):
|
||||
# logging.info("Regular Modbus Status request")
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2007, 2, logging.DEBUG)
|
||||
|
||||
def at_cmd_forbidden(self, cmd: str, connection: str) -> bool:
|
||||
return not cmd.startswith(tuple(self.at_acl[connection]['allow'])) or \
|
||||
cmd.startswith(tuple(self.at_acl[connection]['block']))
|
||||
|
||||
async def send_at_cmd(self, AT_cmd: str) -> None:
|
||||
if self.state != self.STATE_UP:
|
||||
logger.warn(f'[{self.node_id}] ignore AT+ cmd,'
|
||||
' as the state is not UP')
|
||||
if self.state != State.up:
|
||||
logger.warning(f'[{self.node_id}] ignore AT+ cmd,'
|
||||
' as the state is not UP')
|
||||
return
|
||||
AT_cmd = AT_cmd.strip()
|
||||
|
||||
@@ -375,8 +402,7 @@ class SolarmanV5(Message):
|
||||
node_id = self.node_id
|
||||
key = 'at_resp'
|
||||
logger.info(f'{key}: {data_json}')
|
||||
asyncio.ensure_future(
|
||||
self.publish_mqtt(f'{self.entity_prfx}{node_id}{key}', data_json)) # noqa: E501
|
||||
await self.mqtt.publish(f'{self.entity_prfx}{node_id}{key}', data_json) # noqa: E501
|
||||
return
|
||||
|
||||
self.forward_at_cmd_resp = False
|
||||
@@ -465,7 +491,9 @@ class SolarmanV5(Message):
|
||||
self.__process_data(ftype)
|
||||
self.__forward_msg()
|
||||
self.__send_ack_rsp(0x1210, ftype)
|
||||
self.state = self.STATE_UP
|
||||
if self.state is not State.up:
|
||||
self.state = State.up
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
|
||||
def msg_sync_start(self):
|
||||
data = self._recv_buffer[self.header_len:]
|
||||
@@ -499,13 +527,15 @@ class SolarmanV5(Message):
|
||||
__forward_msg):
|
||||
self.inc_counter('Modbus_Command')
|
||||
else:
|
||||
logger.error('Invalid Modbus Msg')
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
return
|
||||
|
||||
self.__forward_msg()
|
||||
|
||||
async def publish_mqtt(self, key, data):
|
||||
await self.mqtt.publish(key, data) # pragma: no cover
|
||||
def publish_mqtt(self, key, data):
|
||||
asyncio.ensure_future(
|
||||
self.mqtt.publish(key, data))
|
||||
|
||||
def get_cmd_rsp_log_lvl(self) -> int:
|
||||
ftype = self._recv_buffer[self.header_len]
|
||||
@@ -529,8 +559,7 @@ class SolarmanV5(Message):
|
||||
node_id = self.node_id
|
||||
key = 'at_resp'
|
||||
logger.info(f'{key}: {data_json}')
|
||||
asyncio.ensure_future(
|
||||
self.publish_mqtt(f'{self.entity_prfx}{node_id}{key}', data_json)) # noqa: E501
|
||||
self.publish_mqtt(f'{self.entity_prfx}{node_id}{key}', data_json) # noqa: E501
|
||||
return
|
||||
elif ftype == self.MB_RTU_CMD:
|
||||
valid = data[1]
|
||||
@@ -561,7 +590,9 @@ class SolarmanV5(Message):
|
||||
|
||||
self.__forward_msg()
|
||||
self.__send_ack_rsp(0x1710, ftype)
|
||||
self.state = self.STATE_UP
|
||||
if self.state is not State.up:
|
||||
self.state = State.up
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
|
||||
def msg_sync_end(self):
|
||||
data = self._recv_buffer[self.header_len:]
|
||||
|
||||
Reference in New Issue