Read pv module details for HA from config file
This commit is contained in:
@@ -193,6 +193,19 @@ class Infos:
|
||||
Register.MAX_DESIGNED_POWER: {'name': ['inverter', 'Max_Designed_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'designed_power_', 'fmt': '| string + " W"', 'name': 'Max Designed Power', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.RATED_POWER: {'name': ['inverter', 'Rated_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'rated_power_', 'fmt': '| string + " W"', 'name': 'Rated Power', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
|
||||
Register.PV1_MANUFACTURER: {'name': ['inverter', 'PV1_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV1_MODEL: {'name': ['inverter', 'PV1_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV2_MANUFACTURER: {'name': ['inverter', 'PV2_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV2_MODEL: {'name': ['inverter', 'PV2_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV3_MANUFACTURER: {'name': ['inverter', 'PV3_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV3_MODEL: {'name': ['inverter', 'PV3_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV4_MANUFACTURER: {'name': ['inverter', 'PV4_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV4_MODEL: {'name': ['inverter', 'PV4_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV5_MANUFACTURER: {'name': ['inverter', 'PV5_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV5_MODEL: {'name': ['inverter', 'PV5_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV6_MANUFACTURER: {'name': ['inverter', 'PV6_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV6_MODEL: {'name': ['inverter', 'PV6_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
|
||||
# proxy:
|
||||
Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': '| int', 'name': 'Active Inverter Connections', 'icon': 'mdi:counter'}}, # noqa: E501
|
||||
Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': '| int', 'name': 'Unknown Serial No', 'icon': 'mdi:counter', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
@@ -530,3 +543,20 @@ class Infos:
|
||||
elif 'less_eq' in dep:
|
||||
return not value <= dep['less_eq']
|
||||
return True
|
||||
|
||||
def set_pv_module_details(self, inv: dict) -> None:
|
||||
map = {'pv1': {'manufacturer': Register.PV1_MANUFACTURER, 'model': Register.PV1_MODEL}, # noqa: E501
|
||||
'pv2': {'manufacturer': Register.PV2_MANUFACTURER, 'model': Register.PV2_MODEL}, # noqa: E501
|
||||
'pv3': {'manufacturer': Register.PV3_MANUFACTURER, 'model': Register.PV3_MODEL}, # noqa: E501
|
||||
'pv4': {'manufacturer': Register.PV4_MANUFACTURER, 'model': Register.PV4_MODEL}, # noqa: E501
|
||||
'pv5': {'manufacturer': Register.PV5_MANUFACTURER, 'model': Register.PV5_MODEL}, # noqa: E501
|
||||
'pv6': {'manufacturer': Register.PV6_MANUFACTURER, 'model': Register.PV6_MODEL} # noqa: E501
|
||||
}
|
||||
|
||||
for key, reg in map.items():
|
||||
if key in inv:
|
||||
if 'manufacturer' in inv[key]:
|
||||
self.set_db_def_value(reg['manufacturer'],
|
||||
inv[key]['manufacturer'])
|
||||
if 'type' in inv[key]:
|
||||
self.set_db_def_value(reg['model'], inv[key]['type'])
|
||||
|
||||
Reference in New Issue
Block a user