S allius/issue120 (#126)
* add config option to disable the modbus polling * read more modbus regs in polling mode * extend connection timeouts if polling mode is disabled * update changelog
This commit is contained in:
@@ -38,7 +38,7 @@ class AsyncStream():
|
||||
if self.state == State.init:
|
||||
to = self.MAX_START_TIME
|
||||
else:
|
||||
if self.server_side:
|
||||
if self.server_side and self.modbus_polling:
|
||||
to = self.MAX_INV_IDLE_TIME
|
||||
else:
|
||||
to = self.MAX_CLOUD_IDLE_TIME
|
||||
|
||||
@@ -58,6 +58,7 @@ class Config():
|
||||
Optional('port', default=8899):
|
||||
And(Use(int), lambda n: 1024 <= n <= 65535)
|
||||
},
|
||||
Optional('modbus_polling', default=True): Use(bool),
|
||||
Optional('suggested_area', default=""): Use(str),
|
||||
Optional('pv1'): {
|
||||
Optional('type'): Use(str),
|
||||
|
||||
@@ -71,6 +71,7 @@ class Talent(Message):
|
||||
self.modbus_elms = 0 # for unit tests
|
||||
self.node_id = 'G3' # will be overwritten in __set_serial_no
|
||||
self.mb_timer = Timer(self.mb_timout_cb, self.node_id)
|
||||
self.modbus_polling = False
|
||||
|
||||
'''
|
||||
Our puplic methods
|
||||
@@ -98,6 +99,7 @@ class Talent(Message):
|
||||
inv = inverters[serial_no]
|
||||
self.node_id = inv['node_id']
|
||||
self.sug_area = inv['suggested_area']
|
||||
self.modbus_polling = inv['modbus_polling']
|
||||
logger.debug(f'SerialNo {serial_no} allowed! area:{self.sug_area}') # noqa: E501
|
||||
self.db.set_pv_module_details(inv)
|
||||
else:
|
||||
@@ -181,9 +183,9 @@ class Talent(Message):
|
||||
|
||||
if 0 == (exp_cnt % 30):
|
||||
# logging.info("Regular Modbus Status request")
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2007, 2, logging.DEBUG)
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.DEBUG)
|
||||
else:
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x3008, 21, logging.DEBUG)
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.DEBUG)
|
||||
|
||||
def _init_new_client_conn(self) -> bool:
|
||||
contact_name = self.contact_name
|
||||
@@ -349,7 +351,8 @@ class Talent(Message):
|
||||
if self.ctrl.is_ind():
|
||||
if self.data_len == 0:
|
||||
self.state = State.pend # block MODBUS cmds
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
if (self.modbus_polling):
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
ts = self._timestamp()
|
||||
logger.debug(f'time: {ts:08x}')
|
||||
self.__build_header(0x91)
|
||||
|
||||
@@ -130,6 +130,7 @@ class SolarmanV5(Message):
|
||||
|
||||
self.node_id = 'G3P' # will be overwritten in __set_serial_no
|
||||
self.mb_timer = Timer(self.mb_timout_cb, self.node_id)
|
||||
self.modbus_polling = False
|
||||
|
||||
'''
|
||||
Our puplic methods
|
||||
@@ -155,9 +156,15 @@ class SolarmanV5(Message):
|
||||
self._send_buffer = bytearray(0)
|
||||
|
||||
self.state = State.up
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 64, logging.INFO)
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.INFO)
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
|
||||
def new_state_up(self):
|
||||
if self.state is not State.up:
|
||||
self.state = State.up
|
||||
if (self.modbus_polling):
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
|
||||
def __set_serial_no(self, snr: int):
|
||||
serial_no = str(snr)
|
||||
if self.unique_id == serial_no:
|
||||
@@ -174,6 +181,7 @@ class SolarmanV5(Message):
|
||||
found = True
|
||||
self.node_id = inv['node_id']
|
||||
self.sug_area = inv['suggested_area']
|
||||
self.modbus_polling = inv['modbus_polling']
|
||||
logger.debug(f'SerialNo {serial_no} allowed! area:{self.sug_area}') # noqa: E501
|
||||
self.db.set_pv_module_details(inv)
|
||||
|
||||
@@ -401,7 +409,7 @@ class SolarmanV5(Message):
|
||||
|
||||
if 0 == (exp_cnt % 30):
|
||||
# logging.info("Regular Modbus Status request")
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 64, logging.DEBUG)
|
||||
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.DEBUG)
|
||||
|
||||
def at_cmd_forbidden(self, cmd: str, connection: str) -> bool:
|
||||
return not cmd.startswith(tuple(self.at_acl[connection]['allow'])) or \
|
||||
@@ -508,9 +516,7 @@ class SolarmanV5(Message):
|
||||
self.__process_data(ftype)
|
||||
self.__forward_msg()
|
||||
self.__send_ack_rsp(0x1210, ftype)
|
||||
if self.state is not State.up:
|
||||
self.state = State.up
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
self.new_state_up()
|
||||
|
||||
def msg_sync_start(self):
|
||||
data = self._recv_buffer[self.header_len:]
|
||||
@@ -607,9 +613,7 @@ class SolarmanV5(Message):
|
||||
|
||||
self.__forward_msg()
|
||||
self.__send_ack_rsp(0x1710, ftype)
|
||||
if self.state is not State.up:
|
||||
self.state = State.up
|
||||
self.mb_timer.start(self.MB_START_TIMEOUT)
|
||||
self.new_state_up()
|
||||
|
||||
def msg_sync_end(self):
|
||||
data = self._recv_buffer[self.header_len:]
|
||||
|
||||
Reference in New Issue
Block a user