add Modbus polling mode for DCU1000 (#305)

* add Modbus scanning mode

* fix modbus polling for DCU 1000

* add modbus register for DCU 1000

* calculate meta values from modbus regs

* update changelog

* reduce code duplication

* refactor modbus_scan

* add additional unit tests
This commit is contained in:
Stefan Allius
2025-03-11 19:47:37 +01:00
committed by GitHub
parent be60f9ea1e
commit 88cb01f613
9 changed files with 386 additions and 32 deletions

View File

@@ -98,13 +98,9 @@ class Talent(Message):
if serial_no in inverters:
inv = inverters[serial_no]
self.node_id = inv['node_id']
self.sug_area = inv['suggested_area']
self.modbus_polling = inv['modbus_polling']
logger.debug(f'SerialNo {serial_no} allowed! area:{self.sug_area}') # noqa: E501
self._set_config_parms(inv)
self.db.set_pv_module_details(inv)
if self.mb:
self.mb.set_node_id(self.node_id)
logger.debug(f'SerialNo {serial_no} allowed! area:{self.sug_area}') # noqa: E501
else:
self.node_id = ''
self.sug_area = ''
@@ -175,12 +171,17 @@ class Talent(Message):
def mb_timout_cb(self, exp_cnt):
self.mb_timer.start(self.mb_timeout)
if self.mb_scan:
self._send_modbus_scan()
return
if 2 == (exp_cnt % 30):
# logging.info("Regular Modbus Status request")
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.DEBUG)
self._send_modbus_cmd(Modbus.INV_ADDR, Modbus.READ_REGS, 0x2000,
96, logging.DEBUG)
else:
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.DEBUG)
self._send_modbus_cmd(Modbus.INV_ADDR, Modbus.READ_REGS, 0x3000,
48, logging.DEBUG)
def _init_new_client_conn(self) -> bool:
contact_name = self.contact_name
@@ -554,6 +555,9 @@ class Talent(Message):
logger.warning('Unknown Message')
self.inc_counter('Unknown_Msg')
return
if (self.mb_scan):
modbus_msg_len = self.data_len - hdr_len
self._dump_modbus_scan(data, hdr_len, modbus_msg_len)
for key, update, _ in self.mb.recv_resp(self.db, data[
hdr_len:]):