reduce code duplications

This commit is contained in:
Stefan Allius
2024-10-17 23:20:13 +02:00
parent ce5bd6eb0a
commit 7d0ea41728
4 changed files with 45 additions and 64 deletions

View File

@@ -8,7 +8,6 @@ if __name__ == "app.src.gen3plus.solarman_v5":
from app.src.async_ifc import AsyncIfc
from app.src.messages import hex_dump_memory, Message, State
from app.src.modbus import Modbus
from app.src.my_timer import Timer
from app.src.config import Config
from app.src.gen3plus.infos_g3p import InfosG3P
from app.src.infos import Register
@@ -17,7 +16,6 @@ else: # pragma: no cover
from messages import hex_dump_memory, Message, State
from config import Config
from modbus import Modbus
from my_timer import Timer
from gen3plus.infos_g3p import InfosG3P
from infos import Register
@@ -53,10 +51,6 @@ class Sequence():
class SolarmanV5(Message):
AT_CMD = 1
MB_RTU_CMD = 2
MB_START_TIMEOUT = 40
'''start delay for Modbus polling in server mode'''
MB_REGULAR_TIMEOUT = 60
'''regular Modbus polling time in server mode'''
MB_CLIENT_DATA_UP = 30
'''Data up time in client mode'''
HDR_FMT = '<BLLL'
@@ -64,14 +58,14 @@ class SolarmanV5(Message):
def __init__(self, addr, ifc: "AsyncIfc",
server_side: bool, client_mode: bool):
super().__init__(server_side, self.send_modbus_cb, mb_timeout=8)
super().__init__('G3P', ifc, server_side, self.send_modbus_cb,
mb_timeout=8)
ifc.rx_set_cb(self.read)
ifc.prot_set_timeout_cb(self._timeout)
ifc.prot_set_init_new_client_conn_cb(self._init_new_client_conn)
ifc.prot_set_update_header_cb(self._update_header)
self.addr = addr
self.ifc = ifc
self.conn_no = ifc.get_conn_no()
self.header_len = 11 # overwrite construcor in class Message
self.control = 0
@@ -136,18 +130,11 @@ class SolarmanV5(Message):
0x4510: logging.INFO, # from server
0x1510: self.get_cmd_rsp_log_lvl,
}
self.modbus_elms = 0 # for unit tests
g3p_cnf = Config.get('gen3plus')
if 'at_acl' in g3p_cnf: # pragma: no cover
self.at_acl = g3p_cnf['at_acl']
self.node_id = 'G3P' # will be overwritten in __set_serial_no
self.mb_timer = Timer(self.mb_timout_cb, self.node_id)
self.mb_timeout = self.MB_REGULAR_TIMEOUT
self.mb_first_timeout = self.MB_START_TIMEOUT
'''timer value for next Modbus polling request'''
self.modbus_polling = False
self.sensor_list = 0x0000
'''
@@ -155,26 +142,11 @@ class SolarmanV5(Message):
'''
def close(self) -> None:
logging.debug('Solarman.close()')
if self.server_side:
# set inverter state to offline, if output power is very low
logging.debug('close power: '
f'{self.db.get_db_value(Register.OUTPUT_POWER, -1)}')
if self.db.get_db_value(Register.OUTPUT_POWER, 999) < 2:
self.db.set_db_def_value(Register.INVERTER_STATUS, 0)
self.new_data['env'] = True
# we have references to methods of this class in self.switch
# so we have to erase self.switch, otherwise this instance can't be
# deallocated by the garbage collector ==> we get a memory leak
self.switch.clear()
self.log_lvl.clear()
self.state = State.closed
self.mb_timer.close()
self.ifc.rx_set_cb(None)
self.ifc.prot_set_timeout_cb(None)
self.ifc.prot_set_init_new_client_conn_cb(None)
self.ifc.prot_set_update_header_cb(None)
self.ifc = None
super().close()
async def send_start_cmd(self, snr: int, host: str,