report alarm and fault bitfield to ha (#204)

* report alarm and fault bitfield to home assistant

* initial verson of message builder for SolarmanV5

- for SolarmaV5 we build he param field for the
  device and inverter message from the internal
  database
- added param description to the info table
  for constant values, which are not parsed and
  stored in internal database

* define constants for often used format strings

* update changelog
This commit is contained in:
Stefan Allius
2024-11-02 15:09:10 +01:00
committed by GitHub
parent 9b22fe354c
commit 78a35b5513
8 changed files with 328 additions and 70 deletions

View File

@@ -7,6 +7,9 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
## [unreleased] ## [unreleased]
- add SolarmanV5 messages builder
- report inverter alarms and faults per MQTT [#7](https://github.com/s-allius/tsun-gen3-proxy/issues/7)
## [0.11.0] - 2024-10-13 ## [0.11.0] - 2024-10-13
- fix healthcheck on infrastructure with IPv6 support [#196](https://github.com/s-allius/tsun-gen3-proxy/issues/196) - fix healthcheck on infrastructure with IPv6 support [#196](https://github.com/s-allius/tsun-gen3-proxy/issues/196)

View File

@@ -70,22 +70,10 @@ class RegisterMap:
0x000d0020: {'reg': Register.COLLECT_INTERVAL}, 0x000d0020: {'reg': Register.COLLECT_INTERVAL},
0x000cf850: {'reg': Register.DATA_UP_INTERVAL}, 0x000cf850: {'reg': Register.DATA_UP_INTERVAL},
0x000c7f38: {'reg': Register.COMMUNICATION_TYPE}, 0x000c7f38: {'reg': Register.COMMUNICATION_TYPE},
0x00000191: {'reg': Register.EVENT_401}, 0x00000190: {'reg': Register.EVENT_ALARM},
0x00000192: {'reg': Register.EVENT_402}, 0x000001f4: {'reg': Register.EVENT_FAULT},
0x00000193: {'reg': Register.EVENT_403}, 0x00000258: {'reg': Register.EVENT_BF1},
0x00000194: {'reg': Register.EVENT_404}, 0x000002bc: {'reg': Register.EVENT_BF2},
0x00000195: {'reg': Register.EVENT_405},
0x00000196: {'reg': Register.EVENT_406},
0x00000197: {'reg': Register.EVENT_407},
0x00000198: {'reg': Register.EVENT_408},
0x00000199: {'reg': Register.EVENT_409},
0x0000019a: {'reg': Register.EVENT_410},
0x0000019b: {'reg': Register.EVENT_411},
0x0000019c: {'reg': Register.EVENT_412},
0x0000019d: {'reg': Register.EVENT_413},
0x0000019e: {'reg': Register.EVENT_414},
0x0000019f: {'reg': Register.EVENT_415},
0x000001a0: {'reg': Register.EVENT_416},
0x00000064: {'reg': Register.INVERTER_STATUS}, 0x00000064: {'reg': Register.INVERTER_STATUS},
0x0000125c: {'reg': Register.MAX_DESIGNED_POWER}, 0x0000125c: {'reg': Register.MAX_DESIGNED_POWER},
0x00003200: {'reg': Register.OUTPUT_COEFFICIENT, 'ratio': 100/1024}, 0x00003200: {'reg': Register.OUTPUT_COEFFICIENT, 'ratio': 100/1024},

View File

@@ -11,28 +11,48 @@ class RegisterMap:
# make the class read/only by using __slots__ # make the class read/only by using __slots__
__slots__ = () __slots__ = ()
FMT_2_16BIT_VAL = '!HH'
FMT_3_16BIT_VAL = '!HHH'
FMT_4_16BIT_VAL = '!HHHH'
map = { map = {
# 0x41020007: {'reg': Register.DEVICE_SNR, 'fmt': '<L'}, # noqa: E501 # 0x41020007: {'reg': Register.DEVICE_SNR, 'fmt': '<L'}, # noqa: E501
0x41020018: {'reg': Register.DATA_UP_INTERVAL, 'fmt': '<B', 'ratio': 60, 'dep': ProxyMode.SERVER}, # noqa: E501 0x41020018: {'reg': Register.DATA_UP_INTERVAL, 'fmt': '<B', 'ratio': 60, 'dep': ProxyMode.SERVER}, # noqa: E501
0x41020019: {'reg': Register.COLLECT_INTERVAL, 'fmt': '<B', 'quotient': 60, 'dep': ProxyMode.SERVER}, # noqa: E501 0x41020019: {'reg': Register.COLLECT_INTERVAL, 'fmt': '<B', 'quotient': 60, 'dep': ProxyMode.SERVER}, # noqa: E501
0x4102001a: {'reg': Register.HEARTBEAT_INTERVAL, 'fmt': '<B', 'ratio': 1}, # noqa: E501 0x4102001a: {'reg': Register.HEARTBEAT_INTERVAL, 'fmt': '<B', 'ratio': 1}, # noqa: E501
0x4102001b: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501
0x4102001c: {'reg': Register.SIGNAL_STRENGTH, 'fmt': '<B', 'ratio': 1, 'dep': ProxyMode.SERVER}, # noqa: E501 0x4102001c: {'reg': Register.SIGNAL_STRENGTH, 'fmt': '<B', 'ratio': 1, 'dep': ProxyMode.SERVER}, # noqa: E501
0x4102001d: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501
0x4102001e: {'reg': Register.CHIP_MODEL, 'fmt': '!40s'}, # noqa: E501 0x4102001e: {'reg': Register.CHIP_MODEL, 'fmt': '!40s'}, # noqa: E501
0x41020046: {'reg': Register.MAC_ADDR, 'fmt': '!BBBBBB', 'func': Fmt.mac}, # noqa: E501 0x41020046: {'reg': Register.MAC_ADDR, 'fmt': '!6B', 'func': Fmt.mac}, # noqa: E501
0x4102004c: {'reg': Register.IP_ADDRESS, 'fmt': '!16s'}, # noqa: E501 0x4102004c: {'reg': Register.IP_ADDRESS, 'fmt': '!16s'}, # noqa: E501
0x4102005c: {'reg': None, 'fmt': '<B', 'const': 15}, # noqa: E501
0x4102005e: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501
0x4102005f: {'reg': Register.SENSOR_LIST, 'fmt': '<H', 'func': Fmt.hex4}, # noqa: E501 0x4102005f: {'reg': Register.SENSOR_LIST, 'fmt': '<H', 'func': Fmt.hex4}, # noqa: E501
0x41020061: {'reg': None, 'fmt': '<BBB', 'const': (15, 0, 255)}, # noqa: E501
0x41020064: {'reg': Register.COLLECTOR_FW_VERSION, 'fmt': '!40s'}, # noqa: E501 0x41020064: {'reg': Register.COLLECTOR_FW_VERSION, 'fmt': '!40s'}, # noqa: E501
0x4102008c: {'reg': None, 'fmt': '<BB', 'const': (254, 254)}, # noqa: E501
0x410200b7: {'reg': Register.SSID, 'fmt': '!40s'}, # noqa: E501
0x4201000c: {'reg': Register.SENSOR_LIST, 'fmt': '<H', 'func': Fmt.hex4}, # noqa: E501 0x4201000c: {'reg': Register.SENSOR_LIST, 'fmt': '<H', 'func': Fmt.hex4}, # noqa: E501
0x4201001c: {'reg': Register.POWER_ON_TIME, 'fmt': '<H', 'ratio': 1, 'dep': ProxyMode.SERVER}, # noqa: E501, or packet number 0x4201001c: {'reg': Register.POWER_ON_TIME, 'fmt': '<H', 'ratio': 1, 'dep': ProxyMode.SERVER}, # noqa: E501, or packet number
0x42010020: {'reg': Register.SERIAL_NUMBER, 'fmt': '!16s'}, # noqa: E501 0x42010020: {'reg': Register.SERIAL_NUMBER, 'fmt': '!16s'}, # noqa: E501
# Start MODBUS Block: 0x3000 (R/O Measurements)
0x420100c0: {'reg': Register.INVERTER_STATUS, 'fmt': '!H'}, # noqa: E501 0x420100c0: {'reg': Register.INVERTER_STATUS, 'fmt': '!H'}, # noqa: E501
0x420100c2: {'reg': Register.DETECT_STATUS_1, 'fmt': '!H'}, # noqa: E501
0x420100c4: {'reg': Register.DETECT_STATUS_2, 'fmt': '!H'}, # noqa: E501
0x420100c6: {'reg': Register.EVENT_ALARM, 'fmt': '!H'}, # noqa: E501
0x420100c8: {'reg': Register.EVENT_FAULT, 'fmt': '!H'}, # noqa: E501
0x420100ca: {'reg': Register.EVENT_BF1, 'fmt': '!H'}, # noqa: E501
0x420100cc: {'reg': Register.EVENT_BF2, 'fmt': '!H'}, # noqa: E501
# 0x420100ce
0x420100d0: {'reg': Register.VERSION, 'fmt': '!H', 'func': Fmt.version}, # noqa: E501 0x420100d0: {'reg': Register.VERSION, 'fmt': '!H', 'func': Fmt.version}, # noqa: E501
0x420100d2: {'reg': Register.GRID_VOLTAGE, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501 0x420100d2: {'reg': Register.GRID_VOLTAGE, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501
0x420100d4: {'reg': Register.GRID_CURRENT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 0x420100d4: {'reg': Register.GRID_CURRENT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
0x420100d6: {'reg': Register.GRID_FREQUENCY, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 0x420100d6: {'reg': Register.GRID_FREQUENCY, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
0x420100d8: {'reg': Register.INVERTER_TEMP, 'fmt': '!H', 'offset': -40}, # noqa: E501 0x420100d8: {'reg': Register.INVERTER_TEMP, 'fmt': '!H', 'offset': -40}, # noqa: E501
# 0x420100d8: {'reg': Register.INVERTER_TEMP, 'fmt': '!H'}, # noqa: E501 # 0x420100da
0x420100dc: {'reg': Register.RATED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501 0x420100dc: {'reg': Register.RATED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501
0x420100de: {'reg': Register.OUTPUT_POWER, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501 0x420100de: {'reg': Register.OUTPUT_POWER, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501
0x420100e0: {'reg': Register.PV1_VOLTAGE, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501 0x420100e0: {'reg': Register.PV1_VOLTAGE, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501
@@ -57,12 +77,34 @@ class RegisterMap:
0x4201010c: {'reg': Register.PV3_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501 0x4201010c: {'reg': Register.PV3_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
0x42010110: {'reg': Register.PV4_DAILY_GENERATION, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 0x42010110: {'reg': Register.PV4_DAILY_GENERATION, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
0x42010112: {'reg': Register.PV4_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501 0x42010112: {'reg': Register.PV4_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
0x42010126: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501 0x42010116: {'reg': Register.INV_UNKNOWN_1, 'fmt': '!H'}, # noqa: E501
# Start MODBUS Block: 0x2000 (R/W Config Paramaneters)
0x42010118: {'reg': Register.BOOT_STATUS, 'fmt': '!H'}, # noqa: E501
0x4201011a: {'reg': Register.DSP_STATUS, 'fmt': '!H'}, # noqa: E501
0x4201011c: {'reg': None, 'fmt': FMT_2_16BIT_VAL, 'const': (1, 0)}, # noqa: E501
0x42010124: {'reg': None, 'fmt': '!H', 'const': 0xffff}, # noqa: E501
0x42010126: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501
0x42010128: {'reg': None, 'fmt': '!H', 'const': 3}, # noqa: E501
0x4201012a: {'reg': None, 'fmt': FMT_3_16BIT_VAL, 'const': (1024, 1024, 1024)}, # noqa: E501
0x42010130: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (1024, 1, 0xffff, 1)}, # noqa: E501
0x42010138: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (6, 0x68, 0x68, 0x500)}, # noqa: E501
0x42010140: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x9cd, 0x7b6, 0x139c, 0x1324)}, # noqa: E501
0x42010148: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (1, 0x7ae, 0x40f, 0x41)}, # noqa: E501
0x42010150: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0xf, 0xa64, 0xa64, 0x6)}, # noqa: E501
0x42010158: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x6, 0x9f6, 0x128c, 0x128c)}, # noqa: E501
0x42010160: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x10, 0x10, 0x1452, 0x1452)}, # noqa: E501
0x42010168: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x10, 0x10, 0x151, 0x5)}, # noqa: E501
0x42010170: {'reg': Register.OUTPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501 0x42010170: {'reg': Register.OUTPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501
0x42010172: {'reg': None, 'fmt': FMT_3_16BIT_VAL, 'const': (0x1, 0x139c, 0xfa0)}, # noqa: E501
0x42010178: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x4e, 0x66, 0x3e8, 0x400)}, # noqa: E501
0x42010180: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x9ce, 0x7a8, 0x139c, 0x1326)}, # noqa: E501
0x42010188: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x0, 0x0, 0x0, 0)}, # noqa: E501
0x42010190: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x0, 0x0, 1024, 1024)}, # noqa: E501
0x4201019a: {'reg': None, 'fmt': FMT_2_16BIT_VAL, 'const': (0, 0xffff)}, # noqa: E501
0xffffff02: {'reg': Register.POLLING_INTERVAL}, 0xffffff02: {'reg': Register.POLLING_INTERVAL},
# 0x4281001c: {'reg': Register.POWER_ON_TIME, 'fmt': '<H', 'ratio': 1}, # noqa: E501 # 0x4281001c: {'reg': Register.POWER_ON_TIME, 'fmt': '<H', 'ratio': 1}, # noqa: E501
} }
@@ -136,3 +178,23 @@ class InfosG3P(Infos):
if update: if update:
self.tracer.log(level, f'[{node_id}] GEN3PLUS: {name}' self.tracer.log(level, f'[{node_id}] GEN3PLUS: {name}'
f' : {result}{unit}') f' : {result}{unit}')
def build(self, len, msg_type: int, rcv_ftype: int):
buf = bytearray(len)
for idx, row in RegisterMap.map.items():
addr = idx & 0xffff
ftype = (idx >> 16) & 0xff
mtype = (idx >> 24) & 0xff
if ftype != rcv_ftype or mtype != msg_type:
continue
if not isinstance(row, dict):
continue
if 'const' in row:
val = row['const']
else:
info_id = row['reg']
val = self.get_db_value(info_id)
if not val:
continue
Fmt.set_value(buf, addr, row, val)
return buf

View File

@@ -43,6 +43,8 @@ class Register(Enum):
RATED_POWER = 84 RATED_POWER = 84
INVERTER_TEMP = 85 INVERTER_TEMP = 85
INVERTER_STATUS = 86 INVERTER_STATUS = 86
DETECT_STATUS_1 = 87
DETECT_STATUS_2 = 88
PV1_VOLTAGE = 100 PV1_VOLTAGE = 100
PV1_CURRENT = 101 PV1_CURRENT = 101
PV1_POWER = 102 PV1_POWER = 102
@@ -85,6 +87,10 @@ class Register(Enum):
PV5_TOTAL_GENERATION = 241 PV5_TOTAL_GENERATION = 241
PV6_DAILY_GENERATION = 250 PV6_DAILY_GENERATION = 250
PV6_TOTAL_GENERATION = 251 PV6_TOTAL_GENERATION = 251
INV_UNKNOWN_1 = 252
BOOT_STATUS = 253
DSP_STATUS = 254
GRID_VOLTAGE = 300 GRID_VOLTAGE = 300
GRID_CURRENT = 301 GRID_CURRENT = 301
GRID_FREQUENCY = 302 GRID_FREQUENCY = 302
@@ -100,22 +106,11 @@ class Register(Enum):
IP_ADDRESS = 407 IP_ADDRESS = 407
POLLING_INTERVAL = 408 POLLING_INTERVAL = 408
SENSOR_LIST = 409 SENSOR_LIST = 409
EVENT_401 = 500 SSID = 410
EVENT_402 = 501 EVENT_ALARM = 500
EVENT_403 = 502 EVENT_FAULT = 501
EVENT_404 = 503 EVENT_BF1 = 502
EVENT_405 = 504 EVENT_BF2 = 503
EVENT_406 = 505
EVENT_407 = 506
EVENT_408 = 507
EVENT_409 = 508
EVENT_410 = 509
EVENT_411 = 510
EVENT_412 = 511
EVENT_413 = 512
EVENT_414 = 513
EVENT_415 = 514
EVENT_416 = 515
TS_INPUT = 600 TS_INPUT = 600
TS_GRID = 601 TS_GRID = 601
TS_TOTAL = 602 TS_TOTAL = 602
@@ -144,17 +139,54 @@ class Fmt:
return result return result
@staticmethod @staticmethod
def hex4(val): def hex4(val: tuple | str, reverse=False) -> str | int:
return f'{val[0]:04x}' if not reverse:
return f'{val[0]:04x}'
else:
return int(val, 16)
@staticmethod @staticmethod
def mac(val): def mac(val: tuple | str, reverse=False) -> str | tuple:
return "%02x:%02x:%02x:%02x:%02x:%02x" % val if not reverse:
return "%02x:%02x:%02x:%02x:%02x:%02x" % val
else:
return (
int(val[0:2], 16), int(val[3:5], 16),
int(val[6:8], 16), int(val[9:11], 16),
int(val[12:14], 16), int(val[15:], 16))
@staticmethod @staticmethod
def version(val): def version(val: tuple | str, reverse=False) -> str | int:
x = val[0] if not reverse:
return f'V{(x >> 12)}.{(x >> 8) & 0xf}.{(x >> 4) & 0xf}{x & 0xf:1X}' x = val[0]
return f'V{(x >> 12)}.{(x >> 8) & 0xf}' \
f'.{(x >> 4) & 0xf}{x & 0xf:1X}'
else:
arr = val[1:].split('.')
return int(arr[0], 10) << 12 | \
int(arr[1], 10) << 8 | \
int(arr[2][:-1], 10) << 4 | \
int(arr[2][-1:], 16)
@staticmethod
def set_value(buf: bytearray, idx: int, row: dict, val):
'''Get a value from buf and interpret as in row defined'''
fmt = row['fmt']
if 'offset' in row:
val = val - row['offset']
if 'quotient' in row:
val = round(val * row['quotient'])
if 'ratio' in row:
val = round(val / row['ratio'])
if 'func' in row:
val = row['func'](val, reverse=True)
if isinstance(val, str):
val = bytes(val, 'UTF8')
if isinstance(val, tuple):
struct.pack_into(fmt, buf, idx, *val)
else:
struct.pack_into(fmt, buf, idx, val)
class ClrAtMidnight: class ClrAtMidnight:
@@ -251,6 +283,99 @@ class Infos:
{{ this.state }} {{ this.state }}
{% endif %} {% endif %}
''' '''
__inv_alarm_val_tpl = '''
{% if 'Inverter_Alarm' in value_json and
value_json['Inverter_Alarm'] != None %}
{% set val_int = value_json['Inverter_Alarm'] | int %}
{% if val_int == 0 %}
{% set result = 'noAlarm'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(1)%}{% set result = result + 'Bit1, '%}
{% endif %}
{% if val_int | bitwise_and(2)%}{% set result = result + 'Bit2, '%}
{% endif %}
{% if val_int | bitwise_and(3)%}{% set result = result + 'Bit3, '%}
{% endif %}
{% if val_int | bitwise_and(4)%}{% set result = result + 'Bit4, '%}
{% endif %}
{% if val_int | bitwise_and(5)%}{% set result = result + 'Bit5, '%}
{% endif %}
{% if val_int | bitwise_and(6)%}{% set result = result + 'Bit6, '%}
{% endif %}
{% if val_int | bitwise_and(7)%}{% set result = result + 'Bit7, '%}
{% endif %}
{% if val_int | bitwise_and(8)%}{% set result = result + 'Bit8, '%}
{% endif %}
{% if val_int | bitwise_and(9)%}{% set result = result + 'noUtility, '%}
{% endif %}
{% if val_int | bitwise_and(10)%}{% set result = result + 'Bit10, '%}
{% endif %}
{% if val_int | bitwise_and(11)%}{% set result = result + 'Bit11, '%}
{% endif %}
{% if val_int | bitwise_and(12)%}{% set result = result + 'Bit12, '%}
{% endif %}
{% if val_int | bitwise_and(13)%}{% set result = result + 'Bit13, '%}
{% endif %}
{% if val_int | bitwise_and(14)%}{% set result = result + 'Bit14, '%}
{% endif %}
{% if val_int | bitwise_and(15)%}{% set result = result + 'Bit15, '%}
{% endif %}
{% if val_int | bitwise_and(16)%}{% set result = result + 'Bit16, '%}
{% endif %}
{% endif %}
{{ result }}
{% else %}
{{ this.state }}
{% endif %}
'''
__inv_fault_val_tpl = '''
{% if 'Inverter_Fault' in value_json and
value_json['Inverter_Fault'] != None %}
{% set val_int = value_json['Inverter_Fault'] | int %}
{% if val_int == 0 %}
{% set result = 'noFault'%}
{%else%}
{% set result = '' %}
{% if val_int | bitwise_and(1)%}{% set result = result + 'Bit1, '%}
{% endif %}
{% if val_int | bitwise_and(2)%}{% set result = result + 'Bit2, '%}
{% endif %}
{% if val_int | bitwise_and(3)%}{% set result = result + 'Bit3, '%}
{% endif %}
{% if val_int | bitwise_and(4)%}{% set result = result + 'Bit4, '%}
{% endif %}
{% if val_int | bitwise_and(5)%}{% set result = result + 'Bit5, '%}
{% endif %}
{% if val_int | bitwise_and(6)%}{% set result = result + 'Bit6, '%}
{% endif %}
{% if val_int | bitwise_and(7)%}{% set result = result + 'Bit7, '%}
{% endif %}
{% if val_int | bitwise_and(8)%}{% set result = result + 'Bit8, '%}
{% endif %}
{% if val_int | bitwise_and(9)%}{% set result = result + 'Bit9, '%}
{% endif %}
{% if val_int | bitwise_and(10)%}{% set result = result + 'Bit10, '%}
{% endif %}
{% if val_int | bitwise_and(11)%}{% set result = result + 'Bit11, '%}
{% endif %}
{% if val_int | bitwise_and(12)%}{% set result = result + 'Bit12, '%}
{% endif %}
{% if val_int | bitwise_and(13)%}{% set result = result + 'Bit13, '%}
{% endif %}
{% if val_int | bitwise_and(14)%}{% set result = result + 'Bit14, '%}
{% endif %}
{% if val_int | bitwise_and(15)%}{% set result = result + 'Bit15, '%}
{% endif %}
{% if val_int | bitwise_and(16)%}{% set result = result + 'Bit16, '%}
{% endif %}
{% endif %}
{{ result }}
{% else %}
{{ this.state }}
{% endif %}
'''
__output_coef_val_tpl = "{% if 'Output_Coefficient' in value_json and value_json['Output_Coefficient'] != None %}{{value_json['Output_Coefficient']|string() +' %'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501 __output_coef_val_tpl = "{% if 'Output_Coefficient' in value_json and value_json['Output_Coefficient'] != None %}{{value_json['Output_Coefficient']|string() +' %'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
__info_defs = { __info_defs = {
@@ -286,7 +411,8 @@ class Infos:
Register.PV5_MODEL: {'name': ['inverter', 'PV5_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 Register.PV5_MODEL: {'name': ['inverter', 'PV5_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.PV6_MANUFACTURER: {'name': ['inverter', 'PV6_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 Register.PV6_MANUFACTURER: {'name': ['inverter', 'PV6_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.PV6_MODEL: {'name': ['inverter', 'PV6_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 Register.PV6_MODEL: {'name': ['inverter', 'PV6_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.BOOT_STATUS: {'name': ['inverter', 'BOOT_STATUS'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.DSP_STATUS: {'name': ['inverter', 'DSP_STATUS'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
# proxy: # proxy:
Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': FMT_INT, 'name': 'Active Inverter Connections', 'icon': COUNTER}}, # noqa: E501 Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': FMT_INT, 'name': 'Active Inverter Connections', 'icon': COUNTER}}, # noqa: E501
Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': FMT_INT, 'name': 'Unknown Serial No', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501 Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': FMT_INT, 'name': 'Unknown Serial No', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
@@ -303,22 +429,12 @@ class Infos:
# 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':FMT_FLOAT,'name': 'Grid Voltage'}}, # noqa: E501 # 0xffffff03: {'name':['proxy', 'Voltage'], 'level': logging.DEBUG, 'unit': 'V', 'ha':{'dev':'proxy', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id':'proxy_volt_', 'fmt':FMT_FLOAT,'name': 'Grid Voltage'}}, # noqa: E501
# events # events
Register.EVENT_401: {'name': ['events', '401_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 Register.EVENT_ALARM: {'name': ['events', 'Inverter_Alarm'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_alarm_', 'name': 'Inverter Alarm', 'val_tpl': __inv_alarm_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
Register.EVENT_402: {'name': ['events', '402_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 Register.EVENT_FAULT: {'name': ['events', 'Inverter_Fault'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_fault_', 'name': 'Inverter Fault', 'val_tpl': __inv_fault_val_tpl, 'icon': 'mdi:alarm-light'}}, # noqa: E501
Register.EVENT_403: {'name': ['events', '403_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 Register.EVENT_BF1: {'name': ['events', 'Inverter_Bitfield_1'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.EVENT_404: {'name': ['events', '404_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 Register.EVENT_BF2: {'name': ['events', 'Inverter_bitfield_2'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.EVENT_405: {'name': ['events', '405_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 # Register.EVENT_409: {'name': ['events', '409_No_Utility'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_406: {'name': ['events', '406_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501 # Register.EVENT_415: {'name': ['events', '415_GridFreqOverRating'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_407: {'name': ['events', '407_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_408: {'name': ['events', '408_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_409: {'name': ['events', '409_No_Utility'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_410: {'name': ['events', '410_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_411: {'name': ['events', '411_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_412: {'name': ['events', '412_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_413: {'name': ['events', '413_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_414: {'name': ['events', '414_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_415: {'name': ['events', '415_GridFreqOverRating'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EVENT_416: {'name': ['events', '416_'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
# grid measures: # grid measures:
Register.TS_GRID: {'name': ['grid', 'Timestamp'], 'level': logging.INFO, 'unit': ''}, # noqa: E501 Register.TS_GRID: {'name': ['grid', 'Timestamp'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
@@ -328,6 +444,8 @@ class Infos:
Register.OUTPUT_POWER: {'name': ['grid', 'Output_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'fmt': FMT_FLOAT, 'name': 'Power'}}, # noqa: E501 Register.OUTPUT_POWER: {'name': ['grid', 'Output_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'fmt': FMT_FLOAT, 'name': 'Power'}}, # noqa: E501
Register.INVERTER_TEMP: {'name': ['env', 'Inverter_Temp'], 'level': logging.DEBUG, 'unit': '°C', 'ha': {'dev': 'inverter', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501 Register.INVERTER_TEMP: {'name': ['env', 'Inverter_Temp'], 'level': logging.DEBUG, 'unit': '°C', 'ha': {'dev': 'inverter', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_', 'fmt': FMT_INT, 'name': 'Temperature'}}, # noqa: E501
Register.INVERTER_STATUS: {'name': ['env', 'Inverter_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_status_', 'name': 'Inverter Status', 'val_tpl': __status_type_val_tpl, 'icon': 'mdi:power'}}, # noqa: E501 Register.INVERTER_STATUS: {'name': ['env', 'Inverter_Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_status_', 'name': 'Inverter Status', 'val_tpl': __status_type_val_tpl, 'icon': 'mdi:power'}}, # noqa: E501
Register.DETECT_STATUS_1: {'name': ['env', 'Detect_Status_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.DETECT_STATUS_2: {'name': ['env', 'Detect_Status_2'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
# input measures: # input measures:
Register.TS_INPUT: {'name': ['input', 'Timestamp'], 'level': logging.INFO, 'unit': ''}, # noqa: E501 Register.TS_INPUT: {'name': ['input', 'Timestamp'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
@@ -377,6 +495,10 @@ class Infos:
Register.IP_ADDRESS: {'name': ['controller', 'IP_Address'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'ip_address_', 'fmt': '| string', 'name': 'IP Address', 'icon': WIFI, 'ent_cat': 'diagnostic'}}, # noqa: E501 Register.IP_ADDRESS: {'name': ['controller', 'IP_Address'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'ip_address_', 'fmt': '| string', 'name': 'IP Address', 'icon': WIFI, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.POLLING_INTERVAL: {'name': ['controller', 'Polling_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'polling_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Polling Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501 Register.POLLING_INTERVAL: {'name': ['controller', 'Polling_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'polling_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Polling Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.SENSOR_LIST: {'name': ['controller', 'Sensor_List'], 'level': logging.INFO, 'unit': ''}, # noqa: E501 Register.SENSOR_LIST: {'name': ['controller', 'Sensor_List'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
Register.SSID: {'name': ['controller', 'WiFi_SSID'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
} }
@property @property
@@ -686,6 +808,8 @@ class Infos:
def get_db_value(self, id: Register, not_found_result: any = None): def get_db_value(self, id: Register, not_found_result: any = None):
'''get database value''' '''get database value'''
if id not in self.info_defs:
return not_found_result
row = self.info_defs[id] row = self.info_defs[id]
if isinstance(row, dict): if isinstance(row, dict):
keys = row['name'] keys = row['name']

View File

@@ -40,10 +40,19 @@ class Modbus():
__crc_tab = [] __crc_tab = []
mb_reg_mapping = { mb_reg_mapping = {
0x2000: {'reg': Register.BOOT_STATUS, 'fmt': '!H'}, # noqa: E501
0x2001: {'reg': Register.DSP_STATUS, 'fmt': '!H'}, # noqa: E501
0x2007: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501 0x2007: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501
0x202c: {'reg': Register.OUTPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501 0x202c: {'reg': Register.OUTPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501
0x3000: {'reg': Register.INVERTER_STATUS, 'fmt': '!H'}, # noqa: E501 0x3000: {'reg': Register.INVERTER_STATUS, 'fmt': '!H'}, # noqa: E501
0x3001: {'reg': Register.DETECT_STATUS_1, 'fmt': '!H'}, # noqa: E501
0x3002: {'reg': Register.DETECT_STATUS_2, 'fmt': '!H'}, # noqa: E501
0x3003: {'reg': Register.EVENT_ALARM, 'fmt': '!H'}, # noqa: E501
0x3004: {'reg': Register.EVENT_FAULT, 'fmt': '!H'}, # noqa: E501
0x3005: {'reg': Register.EVENT_BF1, 'fmt': '!H'}, # noqa: E501
0x3006: {'reg': Register.EVENT_BF2, 'fmt': '!H'}, # noqa: E501
0x3008: {'reg': Register.VERSION, 'fmt': '!H', 'func': Fmt.version}, # noqa: E501 0x3008: {'reg': Register.VERSION, 'fmt': '!H', 'func': Fmt.version}, # noqa: E501
0x3009: {'reg': Register.GRID_VOLTAGE, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501 0x3009: {'reg': Register.GRID_VOLTAGE, 'fmt': '!H', 'ratio': 0.1}, # noqa: E501
0x300a: {'reg': Register.GRID_CURRENT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 0x300a: {'reg': Register.GRID_CURRENT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
@@ -74,6 +83,7 @@ class Modbus():
0x3026: {'reg': Register.PV3_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501 0x3026: {'reg': Register.PV3_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
0x3028: {'reg': Register.PV4_DAILY_GENERATION, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501 0x3028: {'reg': Register.PV4_DAILY_GENERATION, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501
0x3029: {'reg': Register.PV4_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501 0x3029: {'reg': Register.PV4_TOTAL_GENERATION, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
# 0x302a
} }
def __init__(self, snd_handler: Callable[[bytes, int, str], None], def __init__(self, snd_handler: Callable[[bytes, int, str], None],

View File

@@ -3,7 +3,7 @@ import pytest
import json, math import json, math
import logging import logging
from app.src.infos import Register, ClrAtMidnight from app.src.infos import Register, ClrAtMidnight
from app.src.infos import Infos from app.src.infos import Infos, Fmt
def test_statistic_counter(): def test_statistic_counter():
i = Infos() i = Infos()
@@ -256,3 +256,24 @@ def test_key_obj():
assert level == logging.DEBUG assert level == logging.DEBUG
assert unit == 'kWh' assert unit == 'kWh'
assert must_incr == True assert must_incr == True
def test_hex4_cnv():
tst_val = (0x12ef, )
string = Fmt.hex4(tst_val)
assert string == '12ef'
val = Fmt.hex4(string, reverse=True)
assert val == tst_val[0]
def test_mac_cnv():
tst_val = (0x12, 0x34, 0x67, 0x89, 0xcd, 0xef)
string = Fmt.mac(tst_val)
assert string == '12:34:67:89:cd:ef'
val = Fmt.mac(string, reverse=True)
assert val == tst_val
def test_version_cnv():
tst_val = (0x123f, )
string = Fmt.version(tst_val)
assert string == 'V1.2.3F'
val = Fmt.version(string, reverse=True)
assert val == tst_val[0]

View File

@@ -501,10 +501,10 @@ def test_new_data_types(inv_data_new):
else: else:
assert False assert False
assert tests==15 assert tests==5
assert json.dumps(i.db['inverter']) == json.dumps({"Manufacturer": 0}) assert json.dumps(i.db['inverter']) == json.dumps({"Manufacturer": 0})
assert json.dumps(i.db['input']) == json.dumps({"pv1": {}}) assert json.dumps(i.db['input']) == json.dumps({"pv1": {}})
assert json.dumps(i.db['events']) == json.dumps({"401_": 0, "404_": 0, "405_": 0, "408_": 0, "409_No_Utility": 0, "406_": 0, "416_": 0}) assert json.dumps(i.db['events']) == json.dumps({"Inverter_Alarm": 0, "Inverter_Fault": 0})
def test_invalid_data_type(invalid_data_seq): def test_invalid_data_type(invalid_data_seq):
i = InfosG3() i = InfosG3()

View File

@@ -57,6 +57,7 @@ def inverter_data(): # 0x4210 ftype: 0x01
msg += b'\x01\x61\x00\xa8\x02\x54\x01\x5a\x00\x8a\x01\xe4\x01\x5a\x00\xbd' msg += b'\x01\x61\x00\xa8\x02\x54\x01\x5a\x00\x8a\x01\xe4\x01\x5a\x00\xbd'
msg += b'\x02\x8f\x00\x11\x00\x01\x00\x00\x00\x0b\x00\x00\x27\x98\x00\x04' msg += b'\x02\x8f\x00\x11\x00\x01\x00\x00\x00\x0b\x00\x00\x27\x98\x00\x04'
msg += b'\x00\x00\x0c\x04\x00\x03\x00\x00\x0a\xe7\x00\x05\x00\x00\x0c\x75' msg += b'\x00\x00\x0c\x04\x00\x03\x00\x00\x0a\xe7\x00\x05\x00\x00\x0c\x75'
msg += b'\x00\x00\x00\x00\x06\x16\x02\x00\x00\x00\x55\xaa\x00\x01\x00\x00' msg += b'\x00\x00\x00\x00\x06\x16\x02\x00\x00\x00\x55\xaa\x00\x01\x00\x00'
msg += b'\x00\x00\x00\x00\xff\xff\x07\xd0\x00\x03\x04\x00\x04\x00\x04\x00' msg += b'\x00\x00\x00\x00\xff\xff\x07\xd0\x00\x03\x04\x00\x04\x00\x04\x00'
msg += b'\x04\x00\x00\x01\xff\xff\x00\x01\x00\x06\x00\x68\x00\x68\x05\x00' msg += b'\x04\x00\x00\x01\xff\xff\x00\x01\x00\x06\x00\x68\x00\x68\x05\x00'
@@ -85,10 +86,21 @@ def test_parse_4110(str_test_ip, device_data: bytes):
pass # side effect is calling generator i.parse() pass # side effect is calling generator i.parse()
assert json.dumps(i.db) == json.dumps({ assert json.dumps(i.db) == json.dumps({
'controller': {"Data_Up_Interval": 300, "Collect_Interval": 1, "Heartbeat_Interval": 120, "Signal_Strength": 100, "IP_Address": str_test_ip, "Sensor_List": "02b0"}, 'controller': {"Data_Up_Interval": 300, "Collect_Interval": 1, "Heartbeat_Interval": 120, "Signal_Strength": 100, "IP_Address": str_test_ip, "Sensor_List": "02b0", "WiFi_SSID": "Allius-Home"},
'collector': {"Chip_Model": "LSW5BLE_17_02B0_1.05", "MAC-Addr": "40:2a:8f:4f:51:54", "Collector_Fw_Version": "V1.1.00.0B"}, 'collector': {"Chip_Model": "LSW5BLE_17_02B0_1.05", "MAC-Addr": "40:2a:8f:4f:51:54", "Collector_Fw_Version": "V1.1.00.0B"},
}) })
def test_build_4110(str_test_ip, device_data: bytes):
i = InfosG3P(client_mode=False)
i.db.clear()
for key, update in i.parse (device_data, 0x41, 2):
pass # side effect is calling generator i.parse()
build_msg = i.build(len(device_data), 0x41, 2)
for i in range(11, 20):
build_msg[i] = device_data[i]
assert device_data == build_msg
def test_parse_4210(inverter_data: bytes): def test_parse_4210(inverter_data: bytes):
i = InfosG3P(client_mode=False) i = InfosG3P(client_mode=False)
i.db.clear() i.db.clear()
@@ -98,16 +110,30 @@ def test_parse_4210(inverter_data: bytes):
assert json.dumps(i.db) == json.dumps({ assert json.dumps(i.db) == json.dumps({
"controller": {"Sensor_List": "02b0", "Power_On_Time": 2051}, "controller": {"Sensor_List": "02b0", "Power_On_Time": 2051},
"inverter": {"Serial_Number": "Y17E00000000000E", "Version": "V4.0.10", "Rated_Power": 600, "Max_Designed_Power": 2000, "Output_Coefficient": 100.0}, "inverter": {"Serial_Number": "Y17E00000000000E", "Version": "V4.0.10", "Rated_Power": 600, "BOOT_STATUS": 0, "DSP_STATUS": 21930, "Max_Designed_Power": 2000, "Output_Coefficient": 100.0},
"env": {"Inverter_Status": 1, "Inverter_Temp": 14}, "env": {"Inverter_Status": 1, "Detect_Status_1": 2, "Detect_Status_2": 0, "Inverter_Temp": 14},
"events": {"Inverter_Alarm": 0, "Inverter_Fault": 0, "Inverter_Bitfield_1": 0, "Inverter_bitfield_2": 0},
"grid": {"Voltage": 224.8, "Current": 0.73, "Frequency": 50.05, "Output_Power": 165.8}, "grid": {"Voltage": 224.8, "Current": 0.73, "Frequency": 50.05, "Output_Power": 165.8},
"input": {"pv1": {"Voltage": 35.3, "Current": 1.68, "Power": 59.6, "Daily_Generation": 0.04, "Total_Generation": 30.76}, "input": {"pv1": {"Voltage": 35.3, "Current": 1.68, "Power": 59.6, "Daily_Generation": 0.04, "Total_Generation": 30.76},
"pv2": {"Voltage": 34.6, "Current": 1.38, "Power": 48.4, "Daily_Generation": 0.03, "Total_Generation": 27.91}, "pv2": {"Voltage": 34.6, "Current": 1.38, "Power": 48.4, "Daily_Generation": 0.03, "Total_Generation": 27.91},
"pv3": {"Voltage": 34.6, "Current": 1.89, "Power": 65.5, "Daily_Generation": 0.05, "Total_Generation": 31.89}, "pv3": {"Voltage": 34.6, "Current": 1.89, "Power": 65.5, "Daily_Generation": 0.05, "Total_Generation": 31.89},
"pv4": {"Voltage": 1.7, "Current": 0.01, "Power": 0.0, "Total_Generation": 15.58}}, "pv4": {"Voltage": 1.7, "Current": 0.01, "Power": 0.0, "Total_Generation": 15.58}},
"total": {"Daily_Generation": 0.11, "Total_Generation": 101.36} "total": {"Daily_Generation": 0.11, "Total_Generation": 101.36},
"inv_unknown": {"Unknown_1": 512}
}) })
def test_build_4210(inverter_data: bytes):
i = InfosG3P(client_mode=False)
i.db.clear()
for key, update in i.parse (inverter_data, 0x42, 1):
pass # side effect is calling generator i.parse()
build_msg = i.build(len(inverter_data), 0x42, 1)
for i in range(11, 31):
build_msg[i] = inverter_data[i]
assert inverter_data == build_msg
def test_build_ha_conf1(): def test_build_ha_conf1():
i = InfosG3P(client_mode=False) i = InfosG3P(client_mode=False)
i.static_init() # initialize counter i.static_init() # initialize counter
@@ -269,19 +295,43 @@ def test_exception_and_calc(inverter_data: bytes):
RegisterMap.map[0x420100de] = 'invalid_entry' RegisterMap.map[0x420100de] = 'invalid_entry'
i = InfosG3P(client_mode=False) i = InfosG3P(client_mode=False)
# i.db.clear() i.db.clear()
for key, update in i.parse (inverter_data, 0x42, 1): for key, update in i.parse (inverter_data, 0x42, 1):
pass # side effect is calling generator i.parse() pass # side effect is calling generator i.parse()
assert math.isclose(12.2222, round (i.get_db_value(Register.INVERTER_TEMP, 0),4), rel_tol=1e-09, abs_tol=1e-09) assert math.isclose(12.2222, round (i.get_db_value(Register.INVERTER_TEMP, 0),4), rel_tol=1e-09, abs_tol=1e-09)
build_msg = i.build(len(inverter_data), 0x42, 1)
assert build_msg[32:0xde] == inverter_data[32:0xde]
assert build_msg[0xde:0xe2] == b'\x00\x00\x00\x00'
assert build_msg[0xe2:-1] == inverter_data[0xe2:-1]
# remove a table entry and test parsing and building
del RegisterMap.map[0x420100d8]['quotient'] del RegisterMap.map[0x420100d8]['quotient']
del RegisterMap.map[0x420100d8]['offset'] del RegisterMap.map[0x420100d8]['offset']
RegisterMap.map[0x420100e0]['reg'] = Register.PV1_VOLTAGE # reset mapping i.db.clear()
RegisterMap.map[0x420100de] = backup # reset mapping
for key, update in i.parse (inverter_data, 0x42, 1): for key, update in i.parse (inverter_data, 0x42, 1):
pass # side effect is calling generator i.parse() pass # side effect is calling generator i.parse()
assert 54 == i.get_db_value(Register.INVERTER_TEMP, 0) assert 54 == i.get_db_value(Register.INVERTER_TEMP, 0)
build_msg = i.build(len(inverter_data), 0x42, 1)
assert build_msg[32:0xd8] == inverter_data[32:0xd8]
assert build_msg[0xd8:0xe2] == b'\x006\x00\x00\x02X\x00\x00\x00\x00'
assert build_msg[0xe2:-1] == inverter_data[0xe2:-1]
# test restore table
RegisterMap.map[0x420100d8]['offset'] = ofs RegisterMap.map[0x420100d8]['offset'] = ofs
RegisterMap.map[0x420100e0]['reg'] = Register.PV1_VOLTAGE # reset mapping
RegisterMap.map[0x420100de] = backup # reset mapping
# test orginial table
i.db.clear()
for key, update in i.parse (inverter_data, 0x42, 1):
pass # side effect is calling generator i.parse()
assert 14 == i.get_db_value(Register.INVERTER_TEMP, 0)
build_msg = i.build(len(inverter_data), 0x42, 1)
assert build_msg[32:-1] == inverter_data[32:-1]