Add two states build from the measurements (#351)

* Add two states build from the measurements
- Batterie Status calculated from the batt current
- Power Supply State calc from the out Power

* improve test coverage
This commit is contained in:
Stefan Allius
2025-04-06 01:21:41 +02:00
committed by GitHub
parent 3d073acc58
commit 7782a3cb57
5 changed files with 70 additions and 16 deletions

View File

@@ -126,8 +126,8 @@ class Register(Enum):
BATT_PV2_VOLT = 1002
BATT_PV2_CUR = 1003
BATT_TOTAL_CHARG = 1005
BATT_STATUS_1 = 1006
BATT_STATUS_2 = 1007
BATT_PV1_STATUS = 1006
BATT_PV2_STATUS = 1007
BATT_VOLT = 1010
BATT_CUR = 1011
BATT_SOC = 1012
@@ -160,6 +160,8 @@ class Register(Enum):
BATT_PV_PWR = 1040
BATT_PWR = 1041
BATT_OUT_PWR = 1042
BATT_PWR_SUPL_STATE = 1043
BATT_STATUS = 1044
TEST_VAL_0 = 2000
TEST_VAL_1 = 2001
@@ -377,6 +379,8 @@ class Infos:
__status_type_val_tpl = "{%set inv_status = ['Off-line', 'On-grid', 'Off-grid'] %}{{inv_status[value_json['Inverter_Status']|int(0)]|default(value_json['Inverter_Status'])}}" # noqa: E501
__mppt1_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv1']['MPPT-Status']|int(0)]|default(value_json['pv1']['MPPT-Status'])}}" # noqa: E501
__mppt2_status_type_val_tpl = "{%set mppt_status = ['Standby', 'On', 'Off'] %}{{mppt_status[value_json['pv2']['MPPT-Status']|int(0)]|default(value_json['pv2']['MPPT-Status'])}}" # noqa: E501
__supply_status_type_val_tpl = "{%set supply_status = ['Idle', 'Power-Supply'] %}{{supply_status[value_json['out']['Suppl_State']|int(0)]|default(value_json['out']['Suppl_State'])}}" # noqa: E501
__batt_status_type_val_tpl = "{%set batt_status = ['Discharging', 'Static', 'Loading'] %}{{batt_status[value_json['batt']['Batt_State']|int(0)]|default(value_json['batt']['Batt_State'])}}" # noqa: E501
__out_status_type_val_tpl = "{%set out_status = ['Standby', 'On'] %}{{out_status[value_json['out']['Out_Status']|int(0)]|default(value_json['out']['Out_Status'])}}" # noqa: E501
__rated_power_val_tpl = "{% if 'Rated_Power' in value_json and value_json['Rated_Power'] != None %}{{value_json['Rated_Power']|string() +' W'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
__designed_power_val_tpl = '''
@@ -637,10 +641,10 @@ class Infos:
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
# Batterie DC-1000: Electricity Genration
Register.BATT_STATUS_1: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV1_STATUS: {'name': ['batterie', 'pv1', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status1_', 'name': 'MPPT-1 Status', 'val_tpl': __mppt1_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV1_VOLT: {'name': ['batterie', 'pv1', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV1_CUR: {'name': ['batterie', 'pv1', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_STATUS_2: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV2_STATUS: {'name': ['batterie', 'pv2', 'MPPT-Status'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status2_', 'name': 'MPPT-2 Status', 'val_tpl': __mppt2_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_PV2_VOLT: {'name': ['batterie', 'pv2', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV2_CUR: {'name': ['batterie', 'pv2', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_PV_PWR: {'name': ['batterie', 'PV_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'pv_power_', 'fmt': FMT_INT, 'name': 'PV Power'}}, # noqa: E501
@@ -648,6 +652,7 @@ class Infos:
Register.BATT_OUT_VOLT: {'name': ['batterie', 'out', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'out_volt_', 'val_tpl': "{{ (value_json['out']['Voltage'] | float)}}", 'name': 'Output Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_OUT_CUR: {'name': ['batterie', 'out', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'batterie', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'out_cur_', 'val_tpl': "{{ (value_json['out']['Current'] | float)}}", 'name': 'Output Current', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_OUT_PWR: {'name': ['batterie', 'out', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'out_power_', 'val_tpl': "{{ (value_json['out']['Power'] | int)}}", 'name': 'Supply Power'}}, # noqa: E501
Register.BATT_PWR_SUPL_STATE: {'name': ['batterie', 'out', 'Suppl_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_supply_', 'name': 'Supply State', 'val_tpl': __supply_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
# Batterie DC-1000: Cell Package
Register.BATT_CELL1_VOLT: {'name': ['batterie', 'cell', 'Volt1'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'batterie', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_cell1_', 'val_tpl': "{{ (value_json['cell']['Volt1'] | float)}}", 'name': 'Cell-01 Voltage', 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
@@ -673,6 +678,7 @@ class Infos:
Register.BATT_PWR: {'name': ['batterie', 'batt', 'Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'power_', 'val_tpl': "{{ (value_json['batt']['Power'] | int)}}", 'name': 'Batterie Power'}}, # noqa: E501
Register.BATT_SOC: {'name': ['batterie', 'batt', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'val_tpl': "{{ (value_json['batt']['SOC'] | float)}}", 'name': 'State of Charge (SOC)', 'icon': 'mdi:battery-90'}}, # noqa: E501
Register.BATT_TOTAL_CHARG: {'name': ['batterie', 'batt', 'Total_Charging'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'batterie', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_charg_', 'val_tpl': "{{ (value_json['batt']['Total_Charging'] | float)}}", 'name': TOTAL_CHARG, 'icon': 'mdi:battery-charging', 'must_incr': True}}, # noqa: E501
Register.BATT_STATUS: {'name': ['batterie', 'batt', 'Batt_State'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'status_batt_', 'name': 'Batterie State', 'val_tpl': __batt_status_type_val_tpl, 'icon': POWER}}, # noqa: E501
Register.BATT_TEMP_1: {'name': ['batterie', 'cell', 'Temp_1'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_1_', 'val_tpl': "{{ (value_json['cell']['Temp_1'] | int)}}", 'name': 'Cell Temp-1', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.BATT_TEMP_2: {'name': ['batterie', 'cell', 'Temp_2'], 'level': logging.INFO, 'unit': '°C', 'ha': {'dev': 'batterie', 'dev_cla': 'temperature', 'stat_cla': 'measurement', 'id': 'temp_2_', 'val_tpl': "{{ (value_json['cell']['Temp_2'] | int)}}", 'name': 'Cell Temp-2', 'ent_cat': 'diagnostic'}}, # noqa: E501