Add two states build from the measurements (#351)
* Add two states build from the measurements - Batterie Status calculated from the batt current - Power Supply State calc from the out Power * improve test coverage
This commit is contained in:
@@ -19,6 +19,19 @@ class RegisterFunc:
|
||||
result += prod
|
||||
return result
|
||||
|
||||
@staticmethod
|
||||
def cmp_values(info: Infos, params: map) -> None | int:
|
||||
try:
|
||||
val = info.get_db_value(params['reg'])
|
||||
if val < params['cmp_val']:
|
||||
return params['res'][0]
|
||||
if val == params['cmp_val']:
|
||||
return params['res'][1]
|
||||
return params['res'][2]
|
||||
except Exception:
|
||||
pass
|
||||
return None
|
||||
|
||||
|
||||
class RegisterMap:
|
||||
# make the class read/only by using __slots__
|
||||
@@ -136,8 +149,8 @@ class RegisterMap:
|
||||
0x42010034: {'reg': Register.BATT_PV2_VOLT, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Voltage PV2
|
||||
0x42010036: {'reg': Register.BATT_PV2_CUR, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, DC Current PV2
|
||||
0x42010038: {'reg': Register.BATT_TOTAL_CHARG, 'fmt': '!L', 'ratio': 0.01}, # noqa: E501
|
||||
0x4201003c: {'reg': Register.BATT_STATUS_1, 'fmt': '!H'}, # noqa: E501 MPTT-1 Operating Status: 0(Standby), 1(Work)
|
||||
0x4201003e: {'reg': Register.BATT_STATUS_2, 'fmt': '!H'}, # noqa: E501 MPTT-2 Operating Status: 0(Standby), 1(Work)
|
||||
0x4201003c: {'reg': Register.BATT_PV1_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-1 Operating Status: 0(Standby), 1(Work)
|
||||
0x4201003e: {'reg': Register.BATT_PV2_STATUS, 'fmt': '!H'}, # noqa: E501 MPTT-2 Operating Status: 0(Standby), 1(Work)
|
||||
0x42010040: {'reg': Register.BATT_VOLT, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501
|
||||
0x42010042: {'reg': Register.BATT_CUR, 'fmt': '!h', 'ratio': 0.01}, # noqa: E501 => Batterie Status: <0(Discharging), 0(Static), 0>(Loading)
|
||||
0x42010044: {'reg': Register.BATT_SOC, 'fmt': '!H', 'ratio': 0.01}, # noqa: E501, state of charge (SOC) in percent
|
||||
@@ -173,8 +186,12 @@ class RegisterMap:
|
||||
[Register.BATT_PV2_VOLT, Register.BATT_PV2_CUR]]},
|
||||
2: {'reg': Register.BATT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501
|
||||
'params': [[Register.BATT_VOLT, Register.BATT_CUR]]},
|
||||
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Supply Power => Power Supply State: 0(Idle), 0>(Power Supply)
|
||||
3: {'reg': Register.BATT_OUT_PWR, 'func': RegisterFunc.prod_sum, # noqa: E501 Supply Power => Power Supply State: 0(Idle), 0>(Power Supply)
|
||||
'params': [[Register.BATT_OUT_VOLT, Register.BATT_OUT_CUR]]},
|
||||
4: {'reg': Register.BATT_PWR_SUPL_STATE, 'func': RegisterFunc.cmp_values, # noqa: E501
|
||||
'params': {'reg': Register.BATT_OUT_PWR, 'cmp_val': 0, 'res': [0, 0, 1]}}, # noqa: E501
|
||||
5: {'reg': Register.BATT_STATUS, 'func': RegisterFunc.cmp_values, # noqa: E501
|
||||
'params': {'reg': Register.BATT_CUR, 'cmp_val': 0.0, 'res': [0, 1, 2]}} # noqa: E501
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue
Block a user