add more unit tests

This commit is contained in:
Stefan Allius
2024-05-11 20:53:39 +02:00
parent 73baffe9e0
commit 6fcf4f47c2

View File

@@ -2,7 +2,7 @@
import pytest, logging
from app.src.gen3.talent import Talent, Control
from app.src.config import Config
from app.src.infos import Infos
from app.src.infos import Infos, Register
from app.src.modbus import Modbus
@@ -849,6 +849,41 @@ def test_msg_modbus_rsp2(ConfigTsunInv1, MsgModbusRsp):
assert m.db.stat['proxy']['Modbus_Command'] == 0
m.close()
def test_msg_modbus_rsp3(ConfigTsunInv1, MsgModbusResp20):
ConfigTsunInv1
m = MemoryStream(MsgModbusResp20, (0,), False)
m.append_msg(MsgModbusResp20)
m.forward_modbus_resp = True
m.mb.last_fcode = 3
m.mb.last_len = 20
m.mb.last_reg = 0x3008
assert m.db.db == {}
m.new_data['inverter'] = False
m.read() # read complete msg, and dispatch msg
assert not m.header_valid # must be invalid, since msg was handled and buffer flushed
assert m.mb.err == 0
assert m.msg_count == 1
assert m._forward_buffer==MsgModbusResp20
assert m._send_buffer==b''
assert m.db.db == {'inverter': {'Version': 'V5.1.09', 'Rated_Power': 300}, 'grid': {'Voltage': 225.9, 'Current': 0.41, 'Frequency': 49.99, 'Output_Power': 94.8}, 'env': {'Inverter_Temp': 22}, 'input': {'pv1': {'Voltage': 0.8, 'Current': 0.0, 'Power': 0.0}, 'pv2': {'Voltage': 34.5, 'Current': 2.89, 'Power': 99.8}, 'pv3': {'Voltage': 0.0, 'Current': 0.0, 'Power': 0.0}, 'pv4': {'Voltage': 0.0, 'Current': 0.0, 'Power': 0.0}}}
assert m.db.get_db_value(Register.VERSION) == 'V5.1.09'
assert m.new_data['inverter'] == True
m.new_data['inverter'] = False
m.read() # read complete msg, and dispatch msg
assert not m.header_valid # must be invalid, since msg was handled and buffer flushed
assert m.mb.err == 0
assert m.msg_count == 2
assert m._forward_buffer==MsgModbusResp20
assert m._send_buffer==b''
assert m.db.db == {'inverter': {'Version': 'V5.1.09', 'Rated_Power': 300}, 'grid': {'Voltage': 225.9, 'Current': 0.41, 'Frequency': 49.99, 'Output_Power': 94.8}, 'env': {'Inverter_Temp': 22}, 'input': {'pv1': {'Voltage': 0.8, 'Current': 0.0, 'Power': 0.0}, 'pv2': {'Voltage': 34.5, 'Current': 2.89, 'Power': 99.8}, 'pv3': {'Voltage': 0.0, 'Current': 0.0, 'Power': 0.0}, 'pv4': {'Voltage': 0.0, 'Current': 0.0, 'Power': 0.0}}}
assert m.db.get_db_value(Register.VERSION) == 'V5.1.09'
assert m.new_data['inverter'] == False
m.close()
def test_msg_modbus_invalid(ConfigTsunInv1, MsgModbusInv):
ConfigTsunInv1
m = MemoryStream(MsgModbusInv, (0,), False)
@@ -919,3 +954,37 @@ async def test_msg_build_modbus_req(ConfigTsunInv1, MsgModbusCmd):
assert m._forward_buffer == b''
assert m._send_buffer == b''
m.close()
'''
def test_zombie_conn(ConfigTsunInv1, MsgInverterInd):
ConfigTsunInv1
tracer.setLevel(logging.DEBUG)
start_val = MemoryStream._RefNo
m1 = MemoryStream(MsgInverterInd, (0,))
assert MemoryStream._RefNo == 1 + start_val
assert m1.RefNo == 1 + start_val
m2 = MemoryStream(MsgInverterInd, (0,))
assert MemoryStream._RefNo == 2 + start_val
assert m2.RefNo == 2 + start_val
m3 = MemoryStream(MsgInverterInd, (0,))
assert MemoryStream._RefNo == 3 + start_val
assert m3.RefNo == 3 + start_val
assert m1.state == m1.STATE_INIT
assert m2.state == m2.STATE_INIT
assert m3.state == m3.STATE_INIT
m1.read() # read complete msg, and set unique_id
assert m1.state == m1.STATE_UP
assert m2.state == m2.STATE_INIT
assert m3.state == m3.STATE_INIT
m2.read() # read complete msg, and set unique_id
assert m1.state == m1.STATE_CLOSED
assert m2.state == m2.STATE_UP
assert m3.state == m3.STATE_INIT
m3.read() # read complete msg, and set unique_id
assert m1.state == m1.STATE_CLOSED
assert m2.state == m2.STATE_CLOSED
assert m3.state == m3.STATE_UP
m1.close()
m2.close()
m3.close()
'''