From 13b1930599c60c6dfb2b0d42980163535643ec99 Mon Sep 17 00:00:00 2001
From: Stefan Allius <122395479+s-allius@users.noreply.github.com>
Date: Mon, 1 Apr 2024 23:36:43 +0200
Subject: [PATCH 1/2] Update README.md
---
README.md | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/README.md b/README.md
index a60c200..e1cb526 100644
--- a/README.md
+++ b/README.md
@@ -185,7 +185,7 @@ Legend
β: proxy support possible but not testet
π§: Proxy support in preparation
```
-βThe new inverters of the G3 Plus generation (e.g. MS-2000) use a completely different protocol for data transmission to the TSUN server. These inverters are supported from proxy version 0.6.ial numbers of these inverters start with `Y17E` instead of `R17E`
+βThe new inverters of the G3 Plus generation (e.g. MS-2000) use a completely different protocol for data transmission to the TSUN server. These inverters are supported from proxy version 0.6. The serial numbers of these inverters start with `Y17E` instead of `R17E`
If you have one of these combinations with a red question mark, it would be very nice if you could send me a proxy trace so that I can carry out the detailed checks and adjust the device and system tests. [Ask here how to send a trace](https://github.com/s-allius/tsun-gen3-proxy/discussions/categories/traces-for-compatibility-check)
From 4da8f8f3b2f4bbc312bfada4881a02a79ac11b96 Mon Sep 17 00:00:00 2001
From: Stefan Allius <122395479+s-allius@users.noreply.github.com>
Date: Tue, 2 Apr 2024 00:15:04 +0200
Subject: [PATCH 2/2] Update README.md
Compatibility table
---
README.md | 24 ++++++++++++------------
1 file changed, 12 insertions(+), 12 deletions(-)
diff --git a/README.md b/README.md
index e1cb526..ed7d65a 100644
--- a/README.md
+++ b/README.md
@@ -40,11 +40,11 @@ If you use a Pi-hole, you can also store the host entry in the Pi-hole.
## Features
-- supports TSUN G3 inverters: TSOL MS-300, MS-350, MS-400, MS-600, MS-700 and MS-800
-- support for TSUN G3 Plus inverters since proxy version 0.6 (e.g. MS-2000)
+- supports TSUN GEN3 inverters: TSOL MS-300, MS-350, MS-400, MS-600, MS-700 and MS-800
+- support for TSUN GEN3 PLUS inverters since proxy version 0.6 (e.g. MS-2000)
- `MQTT` support
- `Home-Assistant` auto-discovery support
-- Self-sufficient island operation without internet (for TSUN G3 Plus inverters in preparation)
+- Self-sufficient island operation without internet (for TSUN GEN3 PLUS inverters in preparation)
- non-root Docker Container
## Home Assistant Screenshots
@@ -94,12 +94,12 @@ You find more details here: https://toml.io/en/v1.0.0
```toml
-# configuration for tsun cloud for 'generation 3' inverters
+# configuration for tsun cloud for 'GEN3' inverters
tsun.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
tsun.host = 'logger.talent-monitoring.com'
tsun.port = 5005
-# configuration for solarman cloud for 'generation 3 plus' inverters
+# configuration for solarman cloud for 'GEN3 PLUS' inverters
solarman.enabled = true # false: disables connecting to the tsun cloud, and avoids updates
solarman.host = 'iot.talent-monitoring.com'
solarman.port = 10000
@@ -148,7 +148,7 @@ suggested_area = 'garage' # suggested installation place for home-assistant
### Loop the proxy into the connection
To include the proxy in the connection between the inverter and the TSUN Cloud, you must adapt the DNS record of *logger.talent-monitoring.com* within the network that your inverter uses. You need a mapping from logger.talent-monitoring.com to the IP address of the host running the Docker engine.
-The new Generation 3 Plus inverters use a different URL. Here, *iot.talent-monitoring.com* must be redirected.
+The new GEN3 PLUS inverters use a different URL. Here, *iot.talent-monitoring.com* must be redirected.
This can be done, for example, by adding a local DNS record to the Pi-hole if you are using it.
@@ -173,11 +173,11 @@ A combination with a red question mark should work, but I have not checked it in
Micro Inverter Model | Fw. 1.00.06 | Fw. 1.00.17 | Fw. 1.00.20| Fw. 1.1.00.0B
:---|:---:|:---:|:---:|:---:|
-G3 micro inverters (single MPPT):
MS-300, MS-350, MS-400| β | β | β |β
-G3 micro inverters (dual MPPT):
MS-600, MS-700, MS-800| βοΈ | βοΈ | βοΈ |β
-G3 Plus micro inverters:
MS-1600, MS-1800, MS-2000| β |β | β | π§
-balcony micro inverters:
MS-400-D, MS-800-D, MS-2000-D| β | β | β| β
-
+GEN3 micro inverters (single MPPT):
MS300, MS350,MS-400| β | β | β |β
+GEN3 micro inverters (dual MPPT):
MS600, MS700, MS800| βοΈ | βοΈ | βοΈ |β
+GEN3 PLUS micro inverters:
MS1600, MS1800, MS2000| β |β | β | βοΈ
+Balcony micro inverters:
MS400-D, MS800-D, MS2000-D| β | β | β| β
+TITAN micro inverters:
TSOL-MP3000, MP2250, MS3000| β | β | β| β
```
Legend
β: Firmware not available for this devices
@@ -185,7 +185,7 @@ Legend
β: proxy support possible but not testet
π§: Proxy support in preparation
```
-βThe new inverters of the G3 Plus generation (e.g. MS-2000) use a completely different protocol for data transmission to the TSUN server. These inverters are supported from proxy version 0.6. The serial numbers of these inverters start with `Y17E` instead of `R17E`
+βThe new inverters of the GEN3 Plus generation (e.g. MS-2000) use a completely different protocol for data transmission to the TSUN server. These inverters are supported from proxy version 0.6. The serial numbers of these inverters start with `Y17E` instead of `R17E`
If you have one of these combinations with a red question mark, it would be very nice if you could send me a proxy trace so that I can carry out the detailed checks and adjust the device and system tests. [Ask here how to send a trace](https://github.com/s-allius/tsun-gen3-proxy/discussions/categories/traces-for-compatibility-check)