S allius/issue102 (#110)

* hotfix: don't send two MODBUS commands together

* fix unit tests

* remove read loop

* optional sleep between msg read and sending rsp

* wait after read 0.5s before sending a response

* add pending state

* fix state definitions

* determine the connection timeout by the conn state

* avoid sending MODBUS cmds in the inverter's reporting phase

* update changelog
This commit is contained in:
Stefan Allius
2024-06-23 15:06:43 +02:00
committed by GitHub
parent cc233dcb17
commit 6332976c4a
7 changed files with 53 additions and 16 deletions

View File

@@ -852,8 +852,7 @@ def test_read_message_in_chunks2(ConfigTsunInv1, DeviceIndMsg):
assert m.data_len == 0xd4
assert m.msg_count == 1
assert m.db.stat['proxy']['Invalid_Msg_Format'] == 0
while m.read(): # read rest of message
pass
m.read() # read rest of message
assert m.msg_count == 1
assert not m.header_valid # must be invalid, since msg was handled and buffer flushed
assert m.db.stat['proxy']['Invalid_Msg_Format'] == 0

View File

@@ -435,8 +435,7 @@ def test_read_message_in_chunks2(MsgContactInfo):
assert int(m.ctrl)==145
assert m.msg_id==0
assert m.msg_count == 1
while m.read(): # read rest of message
pass
m.read() # read rest of message
assert m.msg_count == 1
assert not m.header_valid # must be invalid, since msg was handled and buffer flushed
m.close()
@@ -807,6 +806,29 @@ def test_msg_inv_ind2(ConfigTsunInv1, MsgInverterIndNew, MsgInverterIndTsOffs, M
assert m._send_buffer==MsgInverterAck
m.close()
def test_msg_inv_ind2(ConfigTsunInv1, MsgInverterIndNew, MsgInverterIndTsOffs, MsgInverterAck):
ConfigTsunInv1
tracer.setLevel(logging.DEBUG)
m = MemoryStream(MsgInverterIndNew, (0,))
m.db.stat['proxy']['Unknown_Ctrl'] = 0
m.db.stat['proxy']['Invalid_Data_Type'] = 0
m.read() # read complete msg, and dispatch msg
assert m.db.stat['proxy']['Unknown_Ctrl'] == 0
assert m.db.stat['proxy']['Invalid_Data_Type'] == 0
assert not m.header_valid # must be invalid, since msg was handled and buffer flushed
assert m.msg_count == 1
assert m.id_str == b"R170000000000001"
assert m.unique_id == 'R170000000000001'
assert int(m.ctrl)==145
assert m.msg_id==4
assert m.header_len==23
assert m.data_len==1165
m.ts_offset = 0
m._update_header(m._forward_buffer)
assert m._forward_buffer==MsgInverterIndNew
assert m._send_buffer==MsgInverterAck
m.close()
def test_msg_inv_ack(ConfigTsunInv1, MsgInverterAck):
ConfigTsunInv1