S allius/issue205 (#207)
* Add SolarmanEmu class * Forward a device ind to establish the EMU connection * Move SolarmanEmu class into a dedicated file * Add cloud connection counter * Send inverter data in emulator mode * Improve emulator mode - parse more values from MQTT register - differ between inverter and logger serial no * Add some unit tests for SolarmanEmu class * Send seconds since last sync in data packets * Increase test coverage
This commit is contained in:
@@ -305,6 +305,14 @@ class AsyncStream(AsyncIfcImpl):
|
||||
f"Fwd Exception for {self.r_addr}:\n"
|
||||
f"{traceback.format_exc()}")
|
||||
|
||||
async def publish_outstanding_mqtt(self):
|
||||
'''Publish all outstanding MQTT topics'''
|
||||
try:
|
||||
await self.async_publ_mqtt()
|
||||
await Proxy._async_publ_mqtt_proxy_stat('proxy')
|
||||
except Exception:
|
||||
pass
|
||||
|
||||
|
||||
class AsyncStreamServer(AsyncStream):
|
||||
def __init__(self, reader: StreamReader, writer: StreamWriter,
|
||||
@@ -354,14 +362,6 @@ class AsyncStreamServer(AsyncStream):
|
||||
self.remote.ifc._writer.write(self.fwd_fifo.get())
|
||||
await self.remote.ifc._writer.drain()
|
||||
|
||||
async def publish_outstanding_mqtt(self):
|
||||
'''Publish all outstanding MQTT topics'''
|
||||
try:
|
||||
await self.async_publ_mqtt()
|
||||
await Proxy._async_publ_mqtt_proxy_stat('proxy')
|
||||
except Exception:
|
||||
pass
|
||||
|
||||
|
||||
class AsyncStreamClient(AsyncStream):
|
||||
def __init__(self, reader: StreamReader, writer: StreamWriter,
|
||||
@@ -381,7 +381,11 @@ class AsyncStreamClient(AsyncStream):
|
||||
|
||||
async def client_loop(self, _: str) -> None:
|
||||
'''Loop for receiving messages from the TSUN cloud (client-side)'''
|
||||
Infos.inc_counter('Cloud_Conn_Cnt')
|
||||
await self.publish_outstanding_mqtt()
|
||||
await self.loop()
|
||||
Infos.dec_counter('Cloud_Conn_Cnt')
|
||||
await self.publish_outstanding_mqtt()
|
||||
logger.info(f'[{self.node_id}:{self.conn_no}] '
|
||||
'Client loop stopped for'
|
||||
f' l{self.l_addr}')
|
||||
|
||||
@@ -57,7 +57,8 @@ class Config():
|
||||
Optional('client_mode'): {
|
||||
'host': Use(str),
|
||||
Optional('port', default=8899):
|
||||
And(Use(int), lambda n: 1024 <= n <= 65535)
|
||||
And(Use(int), lambda n: 1024 <= n <= 65535),
|
||||
Optional('forward', default=False): Use(bool),
|
||||
},
|
||||
Optional('modbus_polling', default=True): Use(bool),
|
||||
Optional('suggested_area', default=""): Use(str),
|
||||
|
||||
@@ -75,7 +75,15 @@ class RegisterMap:
|
||||
0x00000258: {'reg': Register.EVENT_BF1},
|
||||
0x000002bc: {'reg': Register.EVENT_BF2},
|
||||
0x00000064: {'reg': Register.INVERTER_STATUS},
|
||||
|
||||
0x00000fa0: {'reg': Register.BOOT_STATUS},
|
||||
0x00001004: {'reg': Register.DSP_STATUS},
|
||||
0x000010cc: {'reg': Register.WORK_MODE},
|
||||
0x000011f8: {'reg': Register.OUTPUT_SHUTDOWN},
|
||||
0x0000125c: {'reg': Register.MAX_DESIGNED_POWER},
|
||||
0x000012c0: {'reg': Register.RATED_LEVEL},
|
||||
0x00001324: {'reg': Register.INPUT_COEFFICIENT, 'ratio': 100/1024},
|
||||
0x00001388: {'reg': Register.GRID_VOLT_CAL_COEF},
|
||||
0x00003200: {'reg': Register.OUTPUT_COEFFICIENT, 'ratio': 100/1024},
|
||||
}
|
||||
|
||||
|
||||
@@ -17,17 +17,17 @@ class RegisterMap:
|
||||
|
||||
map = {
|
||||
# 0x41020007: {'reg': Register.DEVICE_SNR, 'fmt': '<L'}, # noqa: E501
|
||||
0x41020018: {'reg': Register.DATA_UP_INTERVAL, 'fmt': '<B', 'ratio': 60, 'dep': ProxyMode.SERVER}, # noqa: E501
|
||||
0x41020018: {'reg': Register.DATA_UP_INTERVAL, 'fmt': '<B', 'ratio': 60, 'dep': ProxyMode.SERVER}, # noqa: E501
|
||||
0x41020019: {'reg': Register.COLLECT_INTERVAL, 'fmt': '<B', 'quotient': 60, 'dep': ProxyMode.SERVER}, # noqa: E501
|
||||
0x4102001a: {'reg': Register.HEARTBEAT_INTERVAL, 'fmt': '<B', 'ratio': 1}, # noqa: E501
|
||||
0x4102001b: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501
|
||||
0x4102001b: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501 Max No Of Connected Devices
|
||||
0x4102001c: {'reg': Register.SIGNAL_STRENGTH, 'fmt': '<B', 'ratio': 1, 'dep': ProxyMode.SERVER}, # noqa: E501
|
||||
0x4102001d: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501
|
||||
0x4102001e: {'reg': Register.CHIP_MODEL, 'fmt': '!40s'}, # noqa: E501
|
||||
0x41020046: {'reg': Register.MAC_ADDR, 'fmt': '!6B', 'func': Fmt.mac}, # noqa: E501
|
||||
0x4102004c: {'reg': Register.IP_ADDRESS, 'fmt': '!16s'}, # noqa: E501
|
||||
0x4102005c: {'reg': None, 'fmt': '<B', 'const': 15}, # noqa: E501
|
||||
0x4102005e: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501
|
||||
0x4102005e: {'reg': None, 'fmt': '<B', 'const': 1}, # noqa: E501 No Of Sensors (ListLen)
|
||||
0x4102005f: {'reg': Register.SENSOR_LIST, 'fmt': '<H', 'func': Fmt.hex4}, # noqa: E501
|
||||
0x41020061: {'reg': None, 'fmt': '<BBB', 'const': (15, 0, 255)}, # noqa: E501
|
||||
0x41020064: {'reg': Register.COLLECTOR_FW_VERSION, 'fmt': '!40s'}, # noqa: E501
|
||||
@@ -80,13 +80,16 @@ class RegisterMap:
|
||||
0x42010116: {'reg': Register.INV_UNKNOWN_1, 'fmt': '!H'}, # noqa: E501
|
||||
|
||||
# Start MODBUS Block: 0x2000 (R/W Config Paramaneters)
|
||||
0x42010118: {'reg': Register.BOOT_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x4201011a: {'reg': Register.DSP_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x4201011c: {'reg': None, 'fmt': FMT_2_16BIT_VAL, 'const': (1, 0)}, # noqa: E501
|
||||
0x42010124: {'reg': None, 'fmt': '!H', 'const': 0xffff}, # noqa: E501
|
||||
0x42010126: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501
|
||||
0x42010128: {'reg': None, 'fmt': '!H', 'const': 3}, # noqa: E501
|
||||
0x4201012a: {'reg': None, 'fmt': FMT_3_16BIT_VAL, 'const': (1024, 1024, 1024)}, # noqa: E501
|
||||
0x42010118: {'reg': Register.BOOT_STATUS, 'fmt': '!H'},
|
||||
0x4201011a: {'reg': Register.DSP_STATUS, 'fmt': '!H'},
|
||||
0x4201011c: {'reg': None, 'fmt': '!H', 'const': 1}, # noqa: E501
|
||||
0x4201011e: {'reg': Register.WORK_MODE, 'fmt': '!H'},
|
||||
0x42010124: {'reg': Register.OUTPUT_SHUTDOWN, 'fmt': '!H'},
|
||||
0x42010126: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H'},
|
||||
0x42010128: {'reg': Register.RATED_LEVEL, 'fmt': '!H'},
|
||||
0x4201012a: {'reg': Register.INPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501
|
||||
0x4201012c: {'reg': Register.GRID_VOLT_CAL_COEF, 'fmt': '!H'},
|
||||
0x4201012e: {'reg': None, 'fmt': '!H', 'const': 1024}, # noqa: E501
|
||||
0x42010130: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (1024, 1, 0xffff, 1)}, # noqa: E501
|
||||
0x42010138: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (6, 0x68, 0x68, 0x500)}, # noqa: E501
|
||||
0x42010140: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x9cd, 0x7b6, 0x139c, 0x1324)}, # noqa: E501
|
||||
@@ -101,7 +104,8 @@ class RegisterMap:
|
||||
0x42010180: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x9ce, 0x7a8, 0x139c, 0x1326)}, # noqa: E501
|
||||
0x42010188: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x0, 0x0, 0x0, 0)}, # noqa: E501
|
||||
0x42010190: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0x0, 0x0, 1024, 1024)}, # noqa: E501
|
||||
0x4201019a: {'reg': None, 'fmt': FMT_2_16BIT_VAL, 'const': (0, 0xffff)}, # noqa: E501
|
||||
0x42010198: {'reg': None, 'fmt': FMT_4_16BIT_VAL, 'const': (0, 0, 0xffff, 0)}, # noqa: E501
|
||||
0x420101a0: {'reg': None, 'fmt': FMT_2_16BIT_VAL, 'const': (0x0, 0x0)}, # noqa: E501
|
||||
|
||||
0xffffff02: {'reg': Register.POLLING_INTERVAL},
|
||||
# 0x4281001c: {'reg': Register.POWER_ON_TIME, 'fmt': '<H', 'ratio': 1}, # noqa: E501
|
||||
|
||||
@@ -3,13 +3,18 @@ from asyncio import StreamReader, StreamWriter
|
||||
if __name__ == "app.src.gen3plus.inverter_g3p":
|
||||
from app.src.inverter_base import InverterBase
|
||||
from app.src.gen3plus.solarman_v5 import SolarmanV5
|
||||
from app.src.gen3plus.solarman_emu import SolarmanEmu
|
||||
else: # pragma: no cover
|
||||
from inverter_base import InverterBase
|
||||
from gen3plus.solarman_v5 import SolarmanV5
|
||||
from gen3plus.solarman_emu import SolarmanEmu
|
||||
|
||||
|
||||
class InverterG3P(InverterBase):
|
||||
def __init__(self, reader: StreamReader, writer: StreamWriter,
|
||||
client_mode: bool = False):
|
||||
remote_prot = None
|
||||
if client_mode:
|
||||
remote_prot = SolarmanEmu
|
||||
super().__init__(reader, writer, 'solarman',
|
||||
SolarmanV5, client_mode)
|
||||
SolarmanV5, client_mode, remote_prot)
|
||||
|
||||
144
app/src/gen3plus/solarman_emu.py
Normal file
144
app/src/gen3plus/solarman_emu.py
Normal file
@@ -0,0 +1,144 @@
|
||||
import logging
|
||||
import struct
|
||||
|
||||
if __name__ == "app.src.gen3plus.solarman_emu":
|
||||
from app.src.async_ifc import AsyncIfc
|
||||
from app.src.gen3plus.solarman_v5 import SolarmanBase
|
||||
from app.src.my_timer import Timer
|
||||
from app.src.infos import Register
|
||||
else: # pragma: no cover
|
||||
from async_ifc import AsyncIfc
|
||||
from gen3plus.solarman_v5 import SolarmanBase
|
||||
from my_timer import Timer
|
||||
from infos import Register
|
||||
|
||||
logger = logging.getLogger('msg')
|
||||
|
||||
|
||||
class SolarmanEmu(SolarmanBase):
|
||||
def __init__(self, addr, ifc: "AsyncIfc",
|
||||
server_side: bool, client_mode: bool):
|
||||
super().__init__(addr, ifc, server_side=False,
|
||||
_send_modbus_cb=None,
|
||||
mb_timeout=8)
|
||||
logging.debug('SolarmanEmu.init()')
|
||||
self.db = ifc.remote.stream.db
|
||||
self.snr = ifc.remote.stream.snr
|
||||
self.hb_timeout = 60
|
||||
'''actual heatbeat timeout from the last response message'''
|
||||
self.data_up_inv = self.db.get_db_value(Register.DATA_UP_INTERVAL)
|
||||
'''time interval for getting new MQTT data messages'''
|
||||
self.hb_timer = Timer(self.send_heartbeat_cb, self.node_id)
|
||||
self.data_timer = Timer(self.send_data_cb, self.node_id)
|
||||
self.last_sync = self._emu_timestamp()
|
||||
'''timestamp when we send the last sync message (4110)'''
|
||||
self.pkt_cnt = 0
|
||||
'''last sent packet number'''
|
||||
|
||||
self.switch = {
|
||||
|
||||
0x4210: 'msg_data_ind', # real time data
|
||||
0x1210: self.msg_response, # at least every 5 minutes
|
||||
|
||||
0x4710: 'msg_hbeat_ind', # heatbeat
|
||||
0x1710: self.msg_response, # every 2 minutes
|
||||
|
||||
0x4110: 'msg_dev_ind', # device data, sync start
|
||||
0x1110: self.msg_response, # every 3 hours
|
||||
|
||||
}
|
||||
|
||||
self.log_lvl = {
|
||||
|
||||
0x4110: logging.INFO, # device data, sync start
|
||||
0x1110: logging.INFO, # every 3 hours
|
||||
|
||||
0x4210: logging.INFO, # real time data
|
||||
0x1210: logging.INFO, # at least every 5 minutes
|
||||
|
||||
0x4710: logging.DEBUG, # heatbeat
|
||||
0x1710: logging.DEBUG, # every 2 minutes
|
||||
|
||||
}
|
||||
|
||||
'''
|
||||
Our puplic methods
|
||||
'''
|
||||
def close(self) -> None:
|
||||
logging.info('SolarmanEmu.close()')
|
||||
# we have references to methods of this class in self.switch
|
||||
# so we have to erase self.switch, otherwise this instance can't be
|
||||
# deallocated by the garbage collector ==> we get a memory leak
|
||||
self.switch.clear()
|
||||
self.log_lvl.clear()
|
||||
self.hb_timer.close()
|
||||
self.data_timer.close()
|
||||
self.db = None
|
||||
super().close()
|
||||
|
||||
def _set_serial_no(self, snr: int):
|
||||
logging.debug(f'SolarmanEmu._set_serial_no, snr: {snr}')
|
||||
self.unique_id = str(snr)
|
||||
|
||||
def _init_new_client_conn(self) -> bool:
|
||||
logging.debug('SolarmanEmu.init_new()')
|
||||
self.data_timer.start(self.data_up_inv)
|
||||
return False
|
||||
|
||||
def next_pkt_cnt(self):
|
||||
'''get the next packet number'''
|
||||
self.pkt_cnt = (self.pkt_cnt + 1) & 0xffffffff
|
||||
return self.pkt_cnt
|
||||
|
||||
def seconds_since_last_sync(self):
|
||||
'''get seconds since last 0x4110 message was sent'''
|
||||
return self._emu_timestamp() - self.last_sync
|
||||
|
||||
def send_heartbeat_cb(self, exp_cnt):
|
||||
'''send a heartbeat to the TSUN cloud'''
|
||||
self._build_header(0x4710)
|
||||
self.ifc.tx_add(struct.pack('<B', 0))
|
||||
self._finish_send_msg()
|
||||
log_lvl = self.log_lvl.get(0x4710, logging.WARNING)
|
||||
self.ifc.tx_log(log_lvl, 'Send heartbeat:')
|
||||
self.ifc.tx_flush()
|
||||
|
||||
def send_data_cb(self, exp_cnt):
|
||||
'''send a inverter data message to the TSUN cloud'''
|
||||
self.hb_timer.start(self.hb_timeout)
|
||||
self.data_timer.start(self.data_up_inv)
|
||||
_len = 420
|
||||
ftype = 1
|
||||
build_msg = self.db.build(_len, 0x42, ftype)
|
||||
|
||||
self._build_header(0x4210)
|
||||
self.ifc.tx_add(
|
||||
struct.pack(
|
||||
'<BHLLLHL', ftype, 0x02b0,
|
||||
self._emu_timestamp(),
|
||||
self.seconds_since_last_sync(),
|
||||
self.time_ofs,
|
||||
1, # offset 0x1a
|
||||
self.next_pkt_cnt()))
|
||||
self.ifc.tx_add(build_msg[0x20:])
|
||||
self._finish_send_msg()
|
||||
log_lvl = self.log_lvl.get(0x4210, logging.WARNING)
|
||||
self.ifc.tx_log(log_lvl, 'Send inv-data:')
|
||||
self.ifc.tx_flush()
|
||||
|
||||
'''
|
||||
Message handler methods
|
||||
'''
|
||||
def msg_response(self):
|
||||
'''handle a received response from the TSUN cloud'''
|
||||
logger.debug("EMU received rsp:")
|
||||
_, _, ts, hb = super().msg_response()
|
||||
logger.debug(f"EMU ts:{ts} hb:{hb}")
|
||||
self.hb_timeout = hb
|
||||
self.time_ofs = ts - self._emu_timestamp()
|
||||
self.hb_timer.start(self.hb_timeout)
|
||||
|
||||
def msg_unknown(self):
|
||||
'''counts a unknown or unexpected message from the TSUN cloud'''
|
||||
logger.warning(f"EMU Unknow Msg: ID:{int(self.control):#04x}")
|
||||
self.inc_counter('Unknown_Msg')
|
||||
@@ -10,14 +10,14 @@ if __name__ == "app.src.gen3plus.solarman_v5":
|
||||
from app.src.modbus import Modbus
|
||||
from app.src.config import Config
|
||||
from app.src.gen3plus.infos_g3p import InfosG3P
|
||||
from app.src.infos import Register
|
||||
from app.src.infos import Register, Fmt
|
||||
else: # pragma: no cover
|
||||
from async_ifc import AsyncIfc
|
||||
from messages import hex_dump_memory, Message, State
|
||||
from config import Config
|
||||
from modbus import Modbus
|
||||
from gen3plus.infos_g3p import InfosG3P
|
||||
from infos import Register
|
||||
from infos import Register, Fmt
|
||||
|
||||
logger = logging.getLogger('msg')
|
||||
|
||||
@@ -48,7 +48,209 @@ class Sequence():
|
||||
return f'{self.rcv_idx:02x}:{self.snd_idx:02x}'
|
||||
|
||||
|
||||
class SolarmanV5(Message):
|
||||
class SolarmanBase(Message):
|
||||
def __init__(self, addr, ifc: "AsyncIfc", server_side: bool,
|
||||
_send_modbus_cb, mb_timeout: int):
|
||||
super().__init__('G3P', ifc, server_side, _send_modbus_cb,
|
||||
mb_timeout)
|
||||
ifc.rx_set_cb(self.read)
|
||||
ifc.prot_set_timeout_cb(self._timeout)
|
||||
ifc.prot_set_init_new_client_conn_cb(self._init_new_client_conn)
|
||||
ifc.prot_set_update_header_cb(self.__update_header)
|
||||
self.addr = addr
|
||||
self.conn_no = ifc.get_conn_no()
|
||||
self.header_len = 11 # overwrite construcor in class Message
|
||||
self.control = 0
|
||||
self.seq = Sequence(server_side)
|
||||
self.snr = 0
|
||||
self.time_ofs = 0
|
||||
|
||||
def read(self) -> float:
|
||||
'''process all received messages in the _recv_buffer'''
|
||||
self._read()
|
||||
while True:
|
||||
if not self.header_valid:
|
||||
self.__parse_header(self.ifc.rx_peek(),
|
||||
self.ifc.rx_len())
|
||||
|
||||
if self.header_valid and self.ifc.rx_len() >= \
|
||||
(self.header_len + self.data_len+2):
|
||||
self.__process_complete_received_msg()
|
||||
self.__flush_recv_msg()
|
||||
else:
|
||||
return 0 # wait 0s before sending a response
|
||||
'''
|
||||
Our public methods
|
||||
'''
|
||||
def _flow_str(self, server_side: bool, type: str): # noqa: F821
|
||||
switch = {
|
||||
'rx': ' <',
|
||||
'tx': ' >',
|
||||
'forwrd': '<< ',
|
||||
'drop': ' xx',
|
||||
'rxS': '> ',
|
||||
'txS': '< ',
|
||||
'forwrdS': ' >>',
|
||||
'dropS': 'xx ',
|
||||
}
|
||||
if server_side:
|
||||
type += 'S'
|
||||
return switch.get(type, '???')
|
||||
|
||||
def get_fnc_handler(self, ctrl):
|
||||
fnc = self.switch.get(ctrl, self.msg_unknown)
|
||||
if callable(fnc):
|
||||
return fnc, repr(fnc.__name__)
|
||||
else:
|
||||
return self.msg_unknown, repr(fnc)
|
||||
|
||||
def _build_header(self, ctrl) -> None:
|
||||
'''build header for new transmit message'''
|
||||
self.send_msg_ofs = self.ifc.tx_len()
|
||||
|
||||
self.ifc.tx_add(struct.pack(
|
||||
'<BHHHL', 0xA5, 0, ctrl, self.seq.get_send(), self.snr))
|
||||
_fnc, _str = self.get_fnc_handler(ctrl)
|
||||
logger.info(self._flow_str(self.server_side, 'tx') +
|
||||
f' Ctl: {int(ctrl):#04x} Msg: {_str}')
|
||||
|
||||
def _finish_send_msg(self) -> None:
|
||||
'''finish the transmit message, set lenght and checksum'''
|
||||
_len = self.ifc.tx_len() - self.send_msg_ofs
|
||||
struct.pack_into('<H', self.ifc.tx_peek(), self.send_msg_ofs+1,
|
||||
_len-11)
|
||||
check = sum(self.ifc.tx_peek()[
|
||||
self.send_msg_ofs+1:self.send_msg_ofs + _len]) & 0xff
|
||||
self.ifc.tx_add(struct.pack('<BB', check, 0x15)) # crc & stop
|
||||
|
||||
def _timestamp(self):
|
||||
# utc as epoche
|
||||
return int(time.time()) # pragma: no cover
|
||||
|
||||
def _emu_timestamp(self):
|
||||
'''timestamp for an emulated inverter (realtime - 1 day)'''
|
||||
one_day = 24*60*60
|
||||
return self._timestamp()-one_day
|
||||
|
||||
'''
|
||||
Our private methods
|
||||
'''
|
||||
def __update_header(self, _forward_buffer):
|
||||
'''update header for message before forwarding,
|
||||
set sequence and checksum'''
|
||||
_len = len(_forward_buffer)
|
||||
ofs = 0
|
||||
while ofs < _len:
|
||||
result = struct.unpack_from('<BH', _forward_buffer, ofs)
|
||||
data_len = result[1] # len of variable id string
|
||||
|
||||
struct.pack_into('<H', _forward_buffer, ofs+5,
|
||||
self.seq.get_send())
|
||||
|
||||
check = sum(_forward_buffer[ofs+1:ofs+data_len+11]) & 0xff
|
||||
struct.pack_into('<B', _forward_buffer, ofs+data_len+11, check)
|
||||
ofs += (13 + data_len)
|
||||
|
||||
def __process_complete_received_msg(self):
|
||||
log_lvl = self.log_lvl.get(self.control, logging.WARNING)
|
||||
if callable(log_lvl):
|
||||
log_lvl = log_lvl()
|
||||
self.ifc.rx_log(log_lvl, f'Received from {self.addr}:')
|
||||
# self._recv_buffer, self.header_len +
|
||||
# self.data_len+2)
|
||||
if self.__trailer_is_ok(self.ifc.rx_peek(), self.header_len
|
||||
+ self.data_len + 2):
|
||||
if self.state == State.init:
|
||||
self.state = State.received
|
||||
self._set_serial_no(self.snr)
|
||||
self.__dispatch_msg()
|
||||
|
||||
def __parse_header(self, buf: bytes, buf_len: int) -> None:
|
||||
|
||||
if (buf_len < self.header_len): # enough bytes for complete header?
|
||||
return
|
||||
|
||||
result = struct.unpack_from('<BHHHL', buf, 0)
|
||||
|
||||
# store parsed header values in the class
|
||||
start = result[0] # start byte
|
||||
self.data_len = result[1] # len of variable id string
|
||||
self.control = result[2]
|
||||
self.seq.set_recv(result[3])
|
||||
self.snr = result[4]
|
||||
|
||||
if start != 0xA5:
|
||||
hex_dump_memory(logging.ERROR,
|
||||
'Drop packet w invalid start byte from'
|
||||
f' {self.addr}:', buf, buf_len)
|
||||
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
# erase broken recv buffer
|
||||
self.ifc.rx_clear()
|
||||
return
|
||||
self.header_valid = True
|
||||
|
||||
def __trailer_is_ok(self, buf: bytes, buf_len: int) -> bool:
|
||||
crc = buf[self.data_len+11]
|
||||
stop = buf[self.data_len+12]
|
||||
if stop != 0x15:
|
||||
hex_dump_memory(logging.ERROR,
|
||||
'Drop packet w invalid stop byte from '
|
||||
f'{self.addr}:', buf, buf_len)
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
if self.ifc.rx_len() > (self.data_len+13):
|
||||
next_start = buf[self.data_len+13]
|
||||
if next_start != 0xa5:
|
||||
# erase broken recv buffer
|
||||
self.ifc.rx_clear()
|
||||
|
||||
return False
|
||||
|
||||
check = sum(buf[1:buf_len-2]) & 0xff
|
||||
if check != crc:
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
logger.debug(f'CRC {int(crc):#02x} {int(check):#08x}'
|
||||
f' Stop:{int(stop):#02x}')
|
||||
# start & stop byte are valid, discard only this message
|
||||
return False
|
||||
|
||||
return True
|
||||
|
||||
def __flush_recv_msg(self) -> None:
|
||||
self.ifc.rx_get(self.header_len + self.data_len+2)
|
||||
self.header_valid = False
|
||||
|
||||
def __dispatch_msg(self) -> None:
|
||||
_fnc, _str = self.get_fnc_handler(self.control)
|
||||
if self.unique_id:
|
||||
logger.info(self._flow_str(self.server_side, 'rx') +
|
||||
f' Ctl: {int(self.control):#04x}' +
|
||||
f' Msg: {_str}')
|
||||
_fnc()
|
||||
else:
|
||||
logger.info(self._flow_str(self.server_side, 'drop') +
|
||||
f' Ctl: {int(self.control):#04x}' +
|
||||
f' Msg: {_str}')
|
||||
|
||||
'''
|
||||
Message handler methods
|
||||
'''
|
||||
def msg_response(self):
|
||||
data = self.ifc.rx_peek()[self.header_len:]
|
||||
result = struct.unpack_from('<BBLL', data, 0)
|
||||
ftype = result[0] # always 2
|
||||
valid = result[1] == 1 # status
|
||||
ts = result[2]
|
||||
set_hb = result[3] # always 60 or 120
|
||||
logger.debug(f'ftype:{ftype} accepted:{valid}'
|
||||
f' ts:{ts:08x} nextHeartbeat: {set_hb}s')
|
||||
|
||||
dt = datetime.fromtimestamp(ts)
|
||||
logger.debug(f'ts: {dt.strftime("%Y-%m-%d %H:%M:%S")}')
|
||||
return ftype, valid, ts, set_hb
|
||||
|
||||
|
||||
class SolarmanV5(SolarmanBase):
|
||||
AT_CMD = 1
|
||||
MB_RTU_CMD = 2
|
||||
MB_CLIENT_DATA_UP = 30
|
||||
@@ -58,24 +260,15 @@ class SolarmanV5(Message):
|
||||
|
||||
def __init__(self, addr, ifc: "AsyncIfc",
|
||||
server_side: bool, client_mode: bool):
|
||||
super().__init__('G3P', ifc, server_side, self.send_modbus_cb,
|
||||
super().__init__(addr, ifc, server_side, self.send_modbus_cb,
|
||||
mb_timeout=8)
|
||||
ifc.rx_set_cb(self.read)
|
||||
ifc.prot_set_timeout_cb(self._timeout)
|
||||
ifc.prot_set_init_new_client_conn_cb(self._init_new_client_conn)
|
||||
ifc.prot_set_update_header_cb(self._update_header)
|
||||
|
||||
self.addr = addr
|
||||
self.conn_no = ifc.get_conn_no()
|
||||
self.header_len = 11 # overwrite construcor in class Message
|
||||
self.control = 0
|
||||
self.seq = Sequence(server_side)
|
||||
self.snr = 0
|
||||
self.db = InfosG3P(client_mode)
|
||||
self.time_ofs = 0
|
||||
self.forward_at_cmd_resp = False
|
||||
self.no_forwarding = False
|
||||
'''not allowed to connect to TSUN cloud by connection type'''
|
||||
self.establish_inv_emu = False
|
||||
'''create an Solarman EMU instance to send data to the TSUN cloud'''
|
||||
self.switch = {
|
||||
|
||||
0x4210: self.msg_data_ind, # real time data
|
||||
@@ -135,7 +328,7 @@ class SolarmanV5(Message):
|
||||
if 'at_acl' in g3p_cnf: # pragma: no cover
|
||||
self.at_acl = g3p_cnf['at_acl']
|
||||
|
||||
self.sensor_list = 0x0000
|
||||
self.sensor_list = 0
|
||||
|
||||
'''
|
||||
Our puplic methods
|
||||
@@ -150,16 +343,24 @@ class SolarmanV5(Message):
|
||||
super().close()
|
||||
|
||||
async def send_start_cmd(self, snr: int, host: str,
|
||||
forward: bool,
|
||||
start_timeout=MB_CLIENT_DATA_UP):
|
||||
self.no_forwarding = True
|
||||
self.establish_inv_emu = forward
|
||||
self.snr = snr
|
||||
self.__set_serial_no(snr)
|
||||
self._set_serial_no(snr)
|
||||
self.mb_timeout = start_timeout
|
||||
self.db.set_db_def_value(Register.IP_ADDRESS, host)
|
||||
self.db.set_db_def_value(Register.POLLING_INTERVAL,
|
||||
self.mb_timeout)
|
||||
self.db.set_db_def_value(Register.DATA_UP_INTERVAL,
|
||||
300)
|
||||
self.db.set_db_def_value(Register.COLLECT_INTERVAL,
|
||||
1)
|
||||
self.db.set_db_def_value(Register.HEARTBEAT_INTERVAL,
|
||||
120)
|
||||
self.db.set_db_def_value(Register.SENSOR_LIST,
|
||||
Fmt.hex4((self.sensor_list, )))
|
||||
self.new_data['controller'] = True
|
||||
|
||||
self.state = State.up
|
||||
@@ -174,6 +375,15 @@ class SolarmanV5(Message):
|
||||
self.db.set_db_def_value(Register.POLLING_INTERVAL,
|
||||
self.mb_timeout)
|
||||
|
||||
def establish_emu(self):
|
||||
_len = 223
|
||||
build_msg = self.db.build(_len, 0x41, 2)
|
||||
struct.pack_into(
|
||||
'<BHHHLBL', build_msg, 0, 0xA5, _len-11, 0x4110,
|
||||
0, self.snr, 2, self._emu_timestamp())
|
||||
self.ifc.fwd_add(build_msg)
|
||||
self.ifc.fwd_add(struct.pack('<BB', 0, 0x15)) # crc & stop
|
||||
|
||||
def __set_config_parms(self, inv: dict):
|
||||
'''init connection with params from the configuration'''
|
||||
self.node_id = inv['node_id']
|
||||
@@ -183,7 +393,7 @@ class SolarmanV5(Message):
|
||||
if self.mb:
|
||||
self.mb.set_node_id(self.node_id)
|
||||
|
||||
def __set_serial_no(self, snr: int):
|
||||
def _set_serial_no(self, snr: int):
|
||||
'''check the serial number and configure the inverter connection'''
|
||||
serial_no = str(snr)
|
||||
if self.unique_id == serial_no:
|
||||
@@ -200,7 +410,8 @@ class SolarmanV5(Message):
|
||||
self.db.set_pv_module_details(inv)
|
||||
logger.debug(f'SerialNo {serial_no} allowed! area:{self.sug_area}') # noqa: E501
|
||||
|
||||
self.db.set_db_def_value(Register.COLLECTOR_SNR, key)
|
||||
self.db.set_db_def_value(Register.COLLECTOR_SNR, snr)
|
||||
self.db.set_db_def_value(Register.SERIAL_NUMBER, key)
|
||||
break
|
||||
else:
|
||||
self.node_id = ''
|
||||
@@ -214,35 +425,6 @@ class SolarmanV5(Message):
|
||||
|
||||
self.unique_id = serial_no
|
||||
|
||||
def read(self) -> float:
|
||||
'''process all received messages in the _recv_buffer'''
|
||||
self._read()
|
||||
while True:
|
||||
if not self.header_valid:
|
||||
self.__parse_header(self.ifc.rx_peek(),
|
||||
self.ifc.rx_len())
|
||||
|
||||
if self.header_valid and self.ifc.rx_len() >= \
|
||||
(self.header_len + self.data_len+2):
|
||||
self.__process_complete_received_msg()
|
||||
self.__flush_recv_msg()
|
||||
else:
|
||||
return 0 # wait 0s before sending a response
|
||||
|
||||
def __process_complete_received_msg(self):
|
||||
log_lvl = self.log_lvl.get(self.control, logging.WARNING)
|
||||
if callable(log_lvl):
|
||||
log_lvl = log_lvl()
|
||||
self.ifc.rx_log(log_lvl, f'Received from {self.addr}:')
|
||||
# self._recv_buffer, self.header_len +
|
||||
# self.data_len+2)
|
||||
if self.__trailer_is_ok(self.ifc.rx_peek(), self.header_len
|
||||
+ self.data_len + 2):
|
||||
if self.state == State.init:
|
||||
self.state = State.received
|
||||
self.__set_serial_no(self.snr)
|
||||
self.__dispatch_msg()
|
||||
|
||||
def forward(self, buffer, buflen) -> None:
|
||||
'''add the actual receive msg to the forwarding queue'''
|
||||
if self.no_forwarding:
|
||||
@@ -252,158 +434,34 @@ class SolarmanV5(Message):
|
||||
self.ifc.fwd_add(buffer[:buflen])
|
||||
self.ifc.fwd_log(logging.DEBUG, 'Store for forwarding:')
|
||||
|
||||
fnc = self.switch.get(self.control, self.msg_unknown)
|
||||
logger.info(self.__flow_str(self.server_side, 'forwrd') +
|
||||
_, _str = self.get_fnc_handler(self.control)
|
||||
logger.info(self._flow_str(self.server_side, 'forwrd') +
|
||||
f' Ctl: {int(self.control):#04x}'
|
||||
f' Msg: {fnc.__name__!r}')
|
||||
f' Msg: {_str}')
|
||||
|
||||
def _init_new_client_conn(self) -> bool:
|
||||
return False
|
||||
|
||||
'''
|
||||
Our private methods
|
||||
'''
|
||||
def __flow_str(self, server_side: bool, type: str): # noqa: F821
|
||||
switch = {
|
||||
'rx': ' <',
|
||||
'tx': ' >',
|
||||
'forwrd': '<< ',
|
||||
'drop': ' xx',
|
||||
'rxS': '> ',
|
||||
'txS': '< ',
|
||||
'forwrdS': ' >>',
|
||||
'dropS': 'xx ',
|
||||
}
|
||||
if server_side:
|
||||
type += 'S'
|
||||
return switch.get(type, '???')
|
||||
|
||||
def _timestamp(self):
|
||||
# utc as epoche
|
||||
return int(time.time()) # pragma: no cover
|
||||
|
||||
def _heartbeat(self) -> int:
|
||||
return 60 # pragma: no cover
|
||||
|
||||
def __parse_header(self, buf: bytes, buf_len: int) -> None:
|
||||
|
||||
if (buf_len < self.header_len): # enough bytes for complete header?
|
||||
return
|
||||
|
||||
result = struct.unpack_from('<BHHHL', buf, 0)
|
||||
|
||||
# store parsed header values in the class
|
||||
start = result[0] # start byte
|
||||
self.data_len = result[1] # len of variable id string
|
||||
self.control = result[2]
|
||||
self.seq.set_recv(result[3])
|
||||
self.snr = result[4]
|
||||
|
||||
if start != 0xA5:
|
||||
hex_dump_memory(logging.ERROR,
|
||||
'Drop packet w invalid start byte from'
|
||||
f' {self.addr}:', buf, buf_len)
|
||||
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
# erase broken recv buffer
|
||||
self.ifc.rx_clear()
|
||||
return
|
||||
self.header_valid = True
|
||||
|
||||
def __trailer_is_ok(self, buf: bytes, buf_len: int) -> bool:
|
||||
crc = buf[self.data_len+11]
|
||||
stop = buf[self.data_len+12]
|
||||
if stop != 0x15:
|
||||
hex_dump_memory(logging.ERROR,
|
||||
'Drop packet w invalid stop byte from '
|
||||
f'{self.addr}:', buf, buf_len)
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
if self.ifc.rx_len() > (self.data_len+13):
|
||||
next_start = buf[self.data_len+13]
|
||||
if next_start != 0xa5:
|
||||
# erase broken recv buffer
|
||||
self.ifc.rx_clear()
|
||||
|
||||
return False
|
||||
|
||||
check = sum(buf[1:buf_len-2]) & 0xff
|
||||
if check != crc:
|
||||
self.inc_counter('Invalid_Msg_Format')
|
||||
logger.debug(f'CRC {int(crc):#02x} {int(check):#08x}'
|
||||
f' Stop:{int(stop):#02x}')
|
||||
# start & stop byte are valid, discard only this message
|
||||
return False
|
||||
|
||||
return True
|
||||
|
||||
def __build_header(self, ctrl) -> None:
|
||||
'''build header for new transmit message'''
|
||||
self.send_msg_ofs = self.ifc.tx_len()
|
||||
|
||||
self.ifc.tx_add(struct.pack(
|
||||
'<BHHHL', 0xA5, 0, ctrl, self.seq.get_send(), self.snr))
|
||||
fnc = self.switch.get(ctrl, self.msg_unknown)
|
||||
logger.info(self.__flow_str(self.server_side, 'tx') +
|
||||
f' Ctl: {int(ctrl):#04x} Msg: {fnc.__name__!r}')
|
||||
|
||||
def __finish_send_msg(self) -> None:
|
||||
'''finish the transmit message, set lenght and checksum'''
|
||||
_len = self.ifc.tx_len() - self.send_msg_ofs
|
||||
struct.pack_into('<H', self.ifc.tx_peek(), self.send_msg_ofs+1,
|
||||
_len-11)
|
||||
check = sum(self.ifc.tx_peek()[
|
||||
self.send_msg_ofs+1:self.send_msg_ofs + _len]) & 0xff
|
||||
self.ifc.tx_add(struct.pack('<BB', check, 0x15)) # crc & stop
|
||||
|
||||
def _update_header(self, _forward_buffer):
|
||||
'''update header for message before forwarding,
|
||||
set sequence and checksum'''
|
||||
_len = len(_forward_buffer)
|
||||
ofs = 0
|
||||
while ofs < _len:
|
||||
result = struct.unpack_from('<BH', _forward_buffer, ofs)
|
||||
data_len = result[1] # len of variable id string
|
||||
|
||||
struct.pack_into('<H', _forward_buffer, ofs+5,
|
||||
self.seq.get_send())
|
||||
|
||||
check = sum(_forward_buffer[ofs+1:ofs+data_len+11]) & 0xff
|
||||
struct.pack_into('<B', _forward_buffer, ofs+data_len+11, check)
|
||||
ofs += (13 + data_len)
|
||||
|
||||
def __dispatch_msg(self) -> None:
|
||||
fnc = self.switch.get(self.control, self.msg_unknown)
|
||||
if self.unique_id:
|
||||
logger.info(self.__flow_str(self.server_side, 'rx') +
|
||||
f' Ctl: {int(self.control):#04x}' +
|
||||
f' Msg: {fnc.__name__!r}')
|
||||
fnc()
|
||||
else:
|
||||
logger.info(self.__flow_str(self.server_side, 'drop') +
|
||||
f' Ctl: {int(self.control):#04x}' +
|
||||
f' Msg: {fnc.__name__!r}')
|
||||
|
||||
def __flush_recv_msg(self) -> None:
|
||||
self.ifc.rx_get(self.header_len + self.data_len+2)
|
||||
self.header_valid = False
|
||||
|
||||
def __send_ack_rsp(self, msgtype, ftype, ack=1):
|
||||
self.__build_header(msgtype)
|
||||
self._build_header(msgtype)
|
||||
self.ifc.tx_add(struct.pack('<BBLL', ftype, ack,
|
||||
self._timestamp(),
|
||||
self._heartbeat()))
|
||||
self.__finish_send_msg()
|
||||
self._finish_send_msg()
|
||||
|
||||
def send_modbus_cb(self, pdu: bytearray, log_lvl: int, state: str):
|
||||
if self.state != State.up:
|
||||
logger.warning(f'[{self.node_id}] ignore MODBUS cmd,'
|
||||
' cause the state is not UP anymore')
|
||||
return
|
||||
self.__build_header(0x4510)
|
||||
self._build_header(0x4510)
|
||||
self.ifc.tx_add(struct.pack('<BHLLL', self.MB_RTU_CMD,
|
||||
self.sensor_list, 0, 0, 0))
|
||||
self.ifc.tx_add(pdu)
|
||||
self.__finish_send_msg()
|
||||
self._finish_send_msg()
|
||||
self.ifc.tx_log(log_lvl, f'Send Modbus {state}:{self.addr}:')
|
||||
self.ifc.tx_flush()
|
||||
|
||||
@@ -436,11 +494,11 @@ class SolarmanV5(Message):
|
||||
return
|
||||
|
||||
self.forward_at_cmd_resp = False
|
||||
self.__build_header(0x4510)
|
||||
self._build_header(0x4510)
|
||||
self.ifc.tx_add(struct.pack(f'<BHLLL{len(at_cmd)}sc', self.AT_CMD,
|
||||
0x0002, 0, 0, 0,
|
||||
at_cmd.encode('utf-8'), b'\r'))
|
||||
self.__finish_send_msg()
|
||||
self._finish_send_msg()
|
||||
self.ifc.tx_log(logging.INFO, 'Send AT Command:')
|
||||
try:
|
||||
self.ifc.tx_flush()
|
||||
@@ -607,6 +665,18 @@ class SolarmanV5(Message):
|
||||
return
|
||||
self.__forward_msg()
|
||||
|
||||
def __parse_modbus_rsp(self, data):
|
||||
inv_update = False
|
||||
self.modbus_elms = 0
|
||||
for key, update, _ in self.mb.recv_resp(self.db, data[14:]):
|
||||
self.modbus_elms += 1
|
||||
if update:
|
||||
if key == 'inverter':
|
||||
inv_update = True
|
||||
self._set_mqtt_timestamp(key, self._timestamp())
|
||||
self.new_data[key] = True
|
||||
return inv_update
|
||||
|
||||
def __modbus_command_rsp(self, data):
|
||||
'''precess MODBUS RTU response'''
|
||||
valid = data[1]
|
||||
@@ -614,18 +684,13 @@ class SolarmanV5(Message):
|
||||
# logger.debug(f'modbus_len:{modbus_msg_len} accepted:{valid}')
|
||||
if valid == 1 and modbus_msg_len > 4:
|
||||
# logger.info(f'first byte modbus:{data[14]}')
|
||||
inv_update = False
|
||||
self.modbus_elms = 0
|
||||
for key, update, _ in self.mb.recv_resp(self.db, data[14:]):
|
||||
self.modbus_elms += 1
|
||||
if update:
|
||||
if key == 'inverter':
|
||||
inv_update = True
|
||||
self._set_mqtt_timestamp(key, self._timestamp())
|
||||
self.new_data[key] = True
|
||||
inv_update = self.__parse_modbus_rsp(data)
|
||||
if inv_update:
|
||||
self.__build_model_name()
|
||||
|
||||
if self.establish_inv_emu and not self.ifc.remote.stream:
|
||||
self.establish_emu()
|
||||
|
||||
def msg_hbeat_ind(self):
|
||||
data = self.ifc.rx_peek()[self.header_len:]
|
||||
result = struct.unpack_from('<B', data, 0)
|
||||
@@ -647,16 +712,3 @@ class SolarmanV5(Message):
|
||||
|
||||
self.__forward_msg()
|
||||
self.__send_ack_rsp(0x1810, ftype)
|
||||
|
||||
def msg_response(self):
|
||||
data = self.ifc.rx_peek()[self.header_len:]
|
||||
result = struct.unpack_from('<BBLL', data, 0)
|
||||
ftype = result[0] # always 2
|
||||
valid = result[1] == 1 # status
|
||||
ts = result[2]
|
||||
set_hb = result[3] # always 60 or 120
|
||||
logger.debug(f'ftype:{ftype} accepted:{valid}'
|
||||
f' ts:{ts:08x} nextHeartbeat: {set_hb}s')
|
||||
|
||||
dt = datetime.fromtimestamp(ts)
|
||||
logger.debug(f'ts: {dt.strftime("%Y-%m-%d %H:%M:%S")}')
|
||||
|
||||
@@ -26,7 +26,10 @@ class Register(Enum):
|
||||
EQUIPMENT_MODEL = 24
|
||||
NO_INPUTS = 25
|
||||
MAX_DESIGNED_POWER = 26
|
||||
OUTPUT_COEFFICIENT = 27
|
||||
RATED_LEVEL = 27
|
||||
INPUT_COEFFICIENT = 28
|
||||
GRID_VOLT_CAL_COEF = 29
|
||||
OUTPUT_COEFFICIENT = 30
|
||||
INVERTER_CNT = 50
|
||||
UNKNOWN_SNR = 51
|
||||
UNKNOWN_MSG = 52
|
||||
@@ -39,6 +42,7 @@ class Register(Enum):
|
||||
AT_COMMAND = 59
|
||||
MODBUS_COMMAND = 60
|
||||
AT_COMMAND_BLOCKED = 61
|
||||
CLOUD_CONN_CNT = 62
|
||||
OUTPUT_POWER = 83
|
||||
RATED_POWER = 84
|
||||
INVERTER_TEMP = 85
|
||||
@@ -90,6 +94,8 @@ class Register(Enum):
|
||||
INV_UNKNOWN_1 = 252
|
||||
BOOT_STATUS = 253
|
||||
DSP_STATUS = 254
|
||||
WORK_MODE = 255
|
||||
OUTPUT_SHUTDOWN = 256
|
||||
|
||||
GRID_VOLTAGE = 300
|
||||
GRID_CURRENT = 301
|
||||
@@ -269,6 +275,7 @@ class Infos:
|
||||
}
|
||||
|
||||
__comm_type_val_tpl = "{%set com_types = ['n/a','Wi-Fi', 'G4', 'G5', 'GPRS'] %}{{com_types[value_json['Communication_Type']|int(0)]|default(value_json['Communication_Type'])}}" # noqa: E501
|
||||
__work_mode_val_tpl = "{%set mode = ['Normal-Mode', 'Aging-Mode', 'ATE-Mode', 'Shielding GFDI', 'DTU-Mode'] %}{{mode[value_json['Work_Mode']|int(0)]|default(value_json['Work_Mode'])}}" # noqa: E501
|
||||
__status_type_val_tpl = "{%set inv_status = ['Off-line', 'On-grid', 'Off-grid'] %}{{inv_status[value_json['Inverter_Status']|int(0)]|default(value_json['Inverter_Status'])}}" # noqa: E501
|
||||
__rated_power_val_tpl = "{% if 'Rated_Power' in value_json and value_json['Rated_Power'] != None %}{{value_json['Rated_Power']|string() +' W'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
|
||||
__designed_power_val_tpl = '''
|
||||
@@ -376,6 +383,7 @@ class Infos:
|
||||
{% endif %}
|
||||
'''
|
||||
|
||||
__input_coef_val_tpl = "{% if 'Output_Coefficient' in value_json and value_json['Input_Coefficient'] != None %}{{value_json['Input_Coefficient']|string() +' %'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
|
||||
__output_coef_val_tpl = "{% if 'Output_Coefficient' in value_json and value_json['Output_Coefficient'] != None %}{{value_json['Output_Coefficient']|string() +' %'}}{% else %}{{ this.state }}{% endif %}" # noqa: E501
|
||||
|
||||
__info_defs = {
|
||||
@@ -398,6 +406,8 @@ class Infos:
|
||||
Register.NO_INPUTS: {'name': ['inverter', 'No_Inputs'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.MAX_DESIGNED_POWER: {'name': ['inverter', 'Max_Designed_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'designed_power_', 'val_tpl': __designed_power_val_tpl, 'name': 'Max Designed Power', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.RATED_POWER: {'name': ['inverter', 'Rated_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'rated_power_', 'val_tpl': __rated_power_val_tpl, 'name': 'Rated Power', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.WORK_MODE: {'name': ['inverter', 'Work_Mode'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'inverter', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'work_mode_', 'name': 'Work Mode', 'val_tpl': __work_mode_val_tpl, 'icon': 'mdi:power', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INPUT_COEFFICIENT: {'name': ['inverter', 'Input_Coefficient'], 'level': logging.DEBUG, 'unit': '%', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'input_coef_', 'val_tpl': __input_coef_val_tpl, 'name': 'Input Coefficient', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.OUTPUT_COEFFICIENT: {'name': ['inverter', 'Output_Coefficient'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'output_coef_', 'val_tpl': __output_coef_val_tpl, 'name': 'Output Coefficient', 'icon': LIGHTNING, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.PV1_MANUFACTURER: {'name': ['inverter', 'PV1_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.PV1_MODEL: {'name': ['inverter', 'PV1_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
@@ -415,6 +425,7 @@ class Infos:
|
||||
Register.DSP_STATUS: {'name': ['inverter', 'DSP_STATUS'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
# proxy:
|
||||
Register.INVERTER_CNT: {'name': ['proxy', 'Inverter_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_count_', 'fmt': FMT_INT, 'name': 'Active Inverter Connections', 'icon': COUNTER}}, # noqa: E501
|
||||
Register.CLOUD_CONN_CNT: {'name': ['proxy', 'Cloud_Conn_Cnt'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'cloud_conn_count_', 'fmt': FMT_INT, 'name': 'Active Cloud Connections', 'icon': COUNTER}}, # noqa: E501
|
||||
Register.UNKNOWN_SNR: {'name': ['proxy', 'Unknown_SNR'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_snr_', 'fmt': FMT_INT, 'name': 'Unknown Serial No', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.UNKNOWN_MSG: {'name': ['proxy', 'Unknown_Msg'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'unknown_msg_', 'fmt': FMT_INT, 'name': 'Unknown Msg Type', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.INVALID_DATA_TYPE: {'name': ['proxy', 'Invalid_Data_Type'], 'singleton': True, 'ha': {'dev': 'proxy', 'comp': 'sensor', 'dev_cla': None, 'stat_cla': None, 'id': 'inv_data_type_', 'fmt': FMT_INT, 'name': 'Invalid Data Type', 'icon': COUNTER, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
@@ -495,9 +506,12 @@ class Infos:
|
||||
Register.IP_ADDRESS: {'name': ['controller', 'IP_Address'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'ip_address_', 'fmt': '| string', 'name': 'IP Address', 'icon': WIFI, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.POLLING_INTERVAL: {'name': ['controller', 'Polling_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'polling_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Polling Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.SENSOR_LIST: {'name': ['controller', 'Sensor_List'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
||||
Register.SSID: {'name': ['controller', 'WiFi_SSID'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.SSID: {'name': ['controller', 'WiFi_SSID'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
|
||||
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.OUTPUT_SHUTDOWN: {'name': ['other', 'Output_Shutdown'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.RATED_LEVEL: {'name': ['other', 'Rated_Level'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.GRID_VOLT_CAL_COEF: {'name': ['other', 'Grid_Volt_Cal_Coef'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
|
||||
}
|
||||
|
||||
|
||||
@@ -31,12 +31,16 @@ class InverterBase(InverterIfc, Proxy):
|
||||
|
||||
def __init__(self, reader: StreamReader, writer: StreamWriter,
|
||||
config_id: str, prot_class,
|
||||
client_mode: bool = False):
|
||||
client_mode: bool = False,
|
||||
remote_prot_class=None):
|
||||
Proxy.__init__(self)
|
||||
self._registry.append(weakref.ref(self))
|
||||
self.addr = writer.get_extra_info('peername')
|
||||
self.config_id = config_id
|
||||
self.prot_class = prot_class
|
||||
if remote_prot_class:
|
||||
self.prot_class = remote_prot_class
|
||||
else:
|
||||
self.prot_class = prot_class
|
||||
self.__ha_restarts = -1
|
||||
self.remote = StreamPtr(None)
|
||||
ifc = AsyncStreamServer(reader, writer,
|
||||
@@ -45,7 +49,7 @@ class InverterBase(InverterIfc, Proxy):
|
||||
self.remote)
|
||||
|
||||
self.local = StreamPtr(
|
||||
self.prot_class(self.addr, ifc, True, client_mode), ifc
|
||||
prot_class(self.addr, ifc, True, client_mode), ifc
|
||||
)
|
||||
|
||||
def __enter__(self):
|
||||
|
||||
@@ -104,12 +104,14 @@ class Message(ProtocolIfc):
|
||||
self._registry.append(weakref.ref(self))
|
||||
|
||||
self.server_side = server_side
|
||||
if server_side:
|
||||
self.mb = Modbus(send_modbus_cb, mb_timeout)
|
||||
else:
|
||||
self.mb = None
|
||||
self.ifc = ifc
|
||||
self.node_id = node_id
|
||||
if server_side:
|
||||
self.mb = Modbus(send_modbus_cb, mb_timeout)
|
||||
self.mb_timer = Timer(self.mb_timout_cb, self.node_id)
|
||||
else:
|
||||
self.mb = None
|
||||
self.mb_timer = None
|
||||
self.header_valid = False
|
||||
self.header_len = 0
|
||||
self.data_len = 0
|
||||
@@ -119,7 +121,6 @@ class Message(ProtocolIfc):
|
||||
self.state = State.init
|
||||
self.shutdown_started = False
|
||||
self.modbus_elms = 0 # for unit tests
|
||||
self.mb_timer = Timer(self.mb_timout_cb, self.node_id)
|
||||
self.mb_timeout = self.MB_REGULAR_TIMEOUT
|
||||
self.mb_first_timeout = self.MB_START_TIMEOUT
|
||||
'''timer value for next Modbus polling request'''
|
||||
@@ -188,8 +189,8 @@ class Message(ProtocolIfc):
|
||||
if self.db.get_db_value(Register.OUTPUT_POWER, 999) < 2:
|
||||
self.db.set_db_def_value(Register.INVERTER_STATUS, 0)
|
||||
self.new_data['env'] = True
|
||||
self.mb_timer.close()
|
||||
self.state = State.closed
|
||||
self.mb_timer.close()
|
||||
self.ifc.rx_set_cb(None)
|
||||
self.ifc.prot_set_timeout_cb(None)
|
||||
self.ifc.prot_set_init_new_client_conn_cb(None)
|
||||
|
||||
@@ -42,7 +42,13 @@ class Modbus():
|
||||
mb_reg_mapping = {
|
||||
0x2000: {'reg': Register.BOOT_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x2001: {'reg': Register.DSP_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
0x2003: {'reg': Register.WORK_MODE, 'fmt': '!H'},
|
||||
0x2006: {'reg': Register.OUTPUT_SHUTDOWN, 'fmt': '!H'},
|
||||
0x2007: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501
|
||||
0x2008: {'reg': Register.RATED_LEVEL, 'fmt': '!H'},
|
||||
0x2009: {'reg': Register.INPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501
|
||||
0x200a: {'reg': Register.GRID_VOLT_CAL_COEF, 'fmt': '!H'},
|
||||
|
||||
0x202c: {'reg': Register.OUTPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501
|
||||
|
||||
0x3000: {'reg': Register.INVERTER_STATUS, 'fmt': '!H'}, # noqa: E501
|
||||
|
||||
@@ -57,15 +57,17 @@ class ModbusTcp():
|
||||
# logging.info(f"SerialNo:{inv['monitor_sn']} host:{client['host']} port:{client['port']}") # noqa: E501
|
||||
loop.create_task(self.modbus_loop(client['host'],
|
||||
client['port'],
|
||||
inv['monitor_sn']))
|
||||
inv['monitor_sn'],
|
||||
client['forward']))
|
||||
|
||||
async def modbus_loop(self, host, port, snr: int) -> None:
|
||||
async def modbus_loop(self, host, port,
|
||||
snr: int, forward: bool) -> None:
|
||||
'''Loop for receiving messages from the TSUN cloud (client-side)'''
|
||||
while True:
|
||||
try:
|
||||
async with ModbusConn(host, port) as inverter:
|
||||
stream = inverter.local.stream
|
||||
await stream.send_start_cmd(snr, host)
|
||||
await stream.send_start_cmd(snr, host, forward)
|
||||
await stream.ifc.loop()
|
||||
logger.info(f'[{stream.node_id}:{stream.conn_no}] '
|
||||
f'Connection closed - Shutdown: '
|
||||
|
||||
Reference in New Issue