Sonar qube 3 (#165)

* cleanup

* Add support for TSUN Titan inverter
Fixes #161


* fix SonarQube warnings

* fix error

* rename field "config"

* SonarQube reads flake8 output

* don't stop on flake8 errors

* flake8 scan only app/src for SonarQube

* update flake8 run

* ignore flake8 C901

* cleanup

* fix linter warnings

* ignore changed *.yml files

* read sensor list solarman data packets

* catch 'No route to' error and log only in debug mode

* fix unit tests

* add sensor_list configuration

* adapt unit tests

* fix SonarQube warnings
This commit is contained in:
Stefan Allius
2024-08-16 21:07:08 +02:00
committed by GitHub
parent 5a39370cc3
commit 54de2aecfe
11 changed files with 179 additions and 139 deletions

View File

@@ -633,15 +633,15 @@ def msg_unknown_cmd_rsp(): # 0x1510
@pytest.fixture
def config_tsun_allow_all():
Config.config = {'solarman':{'enabled': True}, 'inverters':{'allow_all':True}}
Config.act_config = {'solarman':{'enabled': True}, 'inverters':{'allow_all':True}}
@pytest.fixture
def config_no_tsun_inv1():
Config.config = {'solarman':{'enabled': False},'inverters':{'Y170000000000001':{'monitor_sn': 2070233889, 'node_id':'inv1', 'modbus_polling': True, 'suggested_area':'roof'}}}
Config.act_config = {'solarman':{'enabled': False},'inverters':{'Y170000000000001':{'monitor_sn': 2070233889, 'node_id':'inv1', 'modbus_polling': True, 'suggested_area':'roof', 'sensor_list': 688}}}
@pytest.fixture
def config_tsun_inv1():
Config.config = {'solarman':{'enabled': True},'inverters':{'Y170000000000001':{'monitor_sn': 2070233889, 'node_id':'inv1', 'modbus_polling': True, 'suggested_area':'roof'}}}
Config.act_config = {'solarman':{'enabled': True},'inverters':{'Y170000000000001':{'monitor_sn': 2070233889, 'node_id':'inv1', 'modbus_polling': True, 'suggested_area':'roof', 'sensor_list': 688}}}
def test_read_message(device_ind_msg):
m = MemoryStream(device_ind_msg, (0,))
@@ -843,7 +843,7 @@ def test_read_two_messages(config_tsun_allow_all, device_ind_msg, device_rsp_msg
config_tsun_allow_all
m = MemoryStream(device_ind_msg, (0,))
m.append_msg(inverter_ind_msg)
assert 0 == m.sensor_list
m._init_new_client_conn()
m.read() # read complete msg, and dispatch msg
assert m.db.stat['proxy']['Invalid_Msg_Format'] == 0
@@ -858,6 +858,8 @@ def test_read_two_messages(config_tsun_allow_all, device_ind_msg, device_rsp_msg
assert m.msg_recvd[1]['control']==0x4210
assert m.msg_recvd[1]['seq']=='02:02'
assert m.msg_recvd[1]['data_len']==0x199
assert '02b0' == m.db.get_db_value(Register.SENSOR_LIST, None)
assert 0x02b0 == m.sensor_list
assert m._forward_buffer==device_ind_msg+inverter_ind_msg
assert m._send_buffer==device_rsp_msg+inverter_rsp_msg
@@ -1078,6 +1080,7 @@ def test_sync_end_rsp(config_tsun_inv1, sync_end_rsp_msg):
def test_build_modell_600(config_tsun_allow_all, inverter_ind_msg):
config_tsun_allow_all
m = MemoryStream(inverter_ind_msg, (0,))
assert 0 == m.sensor_list
assert 0 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
assert None == m.db.get_db_value(Register.RATED_POWER, None)
assert None == m.db.get_db_value(Register.INVERTER_TEMP, None)
@@ -1085,6 +1088,8 @@ def test_build_modell_600(config_tsun_allow_all, inverter_ind_msg):
assert 2000 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
assert 600 == m.db.get_db_value(Register.RATED_POWER, 0)
assert 'TSOL-MS2000(600)' == m.db.get_db_value(Register.EQUIPMENT_MODEL, 0)
assert '02b0' == m.db.get_db_value(Register.SENSOR_LIST, None)
assert 0 == m.sensor_list # must not been set by an inverter data ind
m._send_buffer = bytearray(0) # clear send buffer for next test
m._init_new_client_conn()
@@ -1420,6 +1425,7 @@ def test_msg_modbus_req(config_tsun_inv1, msg_modbus_cmd, msg_modbus_cmd_fwd):
config_tsun_inv1
m = MemoryStream(b'')
m.snr = get_sn_int()
m.sensor_list = 0x2b0
m.state = State.up
c = m.createClientStream(msg_modbus_cmd)