reset inverter state on close
- workaround which reset the inverter status to offline when the inverter has a very low output power on connection close
This commit is contained in:
@@ -143,6 +143,14 @@ class SolarmanV5(Message):
|
|||||||
'''
|
'''
|
||||||
def close(self) -> None:
|
def close(self) -> None:
|
||||||
logging.debug('Solarman.close()')
|
logging.debug('Solarman.close()')
|
||||||
|
if self.server_side:
|
||||||
|
# set inverter state to offline, if output power is very low
|
||||||
|
logging.debug('close power: '
|
||||||
|
f'{self.db.get_db_value(Register.OUTPUT_POWER, -1)}')
|
||||||
|
if self.db.get_db_value(Register.OUTPUT_POWER, 999) < 2:
|
||||||
|
self.db.set_db_def_value(Register.INVERTER_STATUS, 0)
|
||||||
|
self.new_data['env'] = True
|
||||||
|
|
||||||
# we have references to methods of this class in self.switch
|
# we have references to methods of this class in self.switch
|
||||||
# so we have to erase self.switch, otherwise this instance can't be
|
# so we have to erase self.switch, otherwise this instance can't be
|
||||||
# deallocated by the garbage collector ==> we get a memory leak
|
# deallocated by the garbage collector ==> we get a memory leak
|
||||||
|
|||||||
Reference in New Issue