set no of pv modules for MS800 GEN3PLUS inverters (#424)

* set no of pv modules for MS800 GEN3PLUS inverters

* fix unit test

* increase test coverage

* change the PV module handling

- in default we set the number of modules now to
  two. So with the first data from the inverter
  we only register two modules. After we determine
  the inverter module, the number can increase to
  four and more PV modules will be registered.

  With the default value of 4, we register always
  4 modules and can't reduce the number of areas
  when we detect that the inverter only supoorts
  two PV modules
This commit is contained in:
Stefan Allius
2025-05-24 23:12:55 +02:00
committed by GitHub
parent 0a8e708735
commit 321c66838d
5 changed files with 63 additions and 4 deletions

View File

@@ -216,7 +216,7 @@ class InfosG3P(Infos):
self.set_db_def_value(Register.MANUFACTURER, 'TSUN')
self.set_db_def_value(Register.EQUIPMENT_MODEL, 'TSOL-MSxx00')
self.set_db_def_value(Register.CHIP_TYPE, 'IGEN TECH')
self.set_db_def_value(Register.NO_INPUTS, 4)
self.set_db_def_value(Register.NO_INPUTS, 2)
def __hide_topic(self, row: dict) -> bool:
if 'dep' in row:

View File

@@ -562,12 +562,17 @@ class SolarmanV5(SolarmanBase):
rated = db.get_db_value(Register.RATED_POWER, 0)
model = None
if max_pow == 2000:
db.set_db_def_value(Register.NO_INPUTS, 4)
if rated == 800 or rated == 600:
model = f'TSOL-MS{max_pow}({rated})'
else:
model = f'TSOL-MS{max_pow}'
elif max_pow == 1800 or max_pow == 1600:
db.set_db_def_value(Register.NO_INPUTS, 4)
model = f'TSOL-MS{max_pow}'
elif max_pow <= 800:
model = f'TSOL-MS{max_pow}'
if model:
logger.info(f'Model: {model}')
self.db.set_db_def_value(Register.EQUIPMENT_MODEL, model)