change the PV module handling
- in default we set the number of modules now to two. So with the first data from the inverter we only register two modules. After we determine the inverter module, the number can increase to four and more PV modules will be registered. With the default value of 4, we register always 4 modules and can't reduce the number of areas when we detect that the inverter only supoorts two PV modules
This commit is contained in:
@@ -216,7 +216,7 @@ class InfosG3P(Infos):
|
||||
self.set_db_def_value(Register.MANUFACTURER, 'TSUN')
|
||||
self.set_db_def_value(Register.EQUIPMENT_MODEL, 'TSOL-MSxx00')
|
||||
self.set_db_def_value(Register.CHIP_TYPE, 'IGEN TECH')
|
||||
self.set_db_def_value(Register.NO_INPUTS, 4)
|
||||
self.set_db_def_value(Register.NO_INPUTS, 2)
|
||||
|
||||
def __hide_topic(self, row: dict) -> bool:
|
||||
if 'dep' in row:
|
||||
|
||||
@@ -562,14 +562,15 @@ class SolarmanV5(SolarmanBase):
|
||||
rated = db.get_db_value(Register.RATED_POWER, 0)
|
||||
model = None
|
||||
if max_pow == 2000:
|
||||
db.set_db_def_value(Register.NO_INPUTS, 4)
|
||||
if rated == 800 or rated == 600:
|
||||
model = f'TSOL-MS{max_pow}({rated})'
|
||||
else:
|
||||
model = f'TSOL-MS{max_pow}'
|
||||
elif max_pow == 1800 or max_pow == 1600:
|
||||
db.set_db_def_value(Register.NO_INPUTS, 4)
|
||||
model = f'TSOL-MS{max_pow}'
|
||||
elif max_pow <= 800:
|
||||
self.db.set_db_def_value(Register.NO_INPUTS, 2)
|
||||
model = f'TSOL-MS{max_pow}'
|
||||
|
||||
if model:
|
||||
|
||||
@@ -109,7 +109,7 @@ def test_default_db():
|
||||
i = InfosG3P(client_mode=False)
|
||||
|
||||
assert json.dumps(i.db) == json.dumps({
|
||||
"inverter": {"Manufacturer": "TSUN", "Equipment_Model": "TSOL-MSxx00", "No_Inputs": 4},
|
||||
"inverter": {"Manufacturer": "TSUN", "Equipment_Model": "TSOL-MSxx00", "No_Inputs": 2},
|
||||
"collector": {"Chip_Type": "IGEN TECH"},
|
||||
})
|
||||
|
||||
@@ -271,7 +271,7 @@ def test_build_ha_conf1():
|
||||
elif id == 'inv_count_456':
|
||||
assert False
|
||||
|
||||
assert tests==7
|
||||
assert tests==5
|
||||
|
||||
def test_build_ha_conf2():
|
||||
i = InfosG3P(client_mode=False)
|
||||
@@ -346,7 +346,7 @@ def test_build_ha_conf3():
|
||||
elif id == 'inv_count_456':
|
||||
assert False
|
||||
|
||||
assert tests==7
|
||||
assert tests==5
|
||||
|
||||
def test_build_ha_conf4():
|
||||
i = InfosG3P(client_mode=True)
|
||||
|
||||
@@ -1468,6 +1468,7 @@ async def test_build_modell_600(my_loop, config_tsun_allow_all, inverter_ind_msg
|
||||
m.read() # read complete msg, and dispatch msg
|
||||
assert 2000 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
|
||||
assert 600 == m.db.get_db_value(Register.RATED_POWER, 0)
|
||||
assert 4 == m.db.get_db_value(Register.NO_INPUTS, 0)
|
||||
assert 'TSOL-MS2000(600)' == m.db.get_db_value(Register.EQUIPMENT_MODEL, 0)
|
||||
assert '02b0' == m.db.get_db_value(Register.SENSOR_LIST, None)
|
||||
assert 0 == m.sensor_list # must not been set by an inverter data ind
|
||||
@@ -1487,6 +1488,7 @@ async def test_build_modell_1600(my_loop, config_tsun_allow_all, inverter_ind_ms
|
||||
m.read() # read complete msg, and dispatch msg
|
||||
assert 1600 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
|
||||
assert 1600 == m.db.get_db_value(Register.RATED_POWER, 0)
|
||||
assert 4 == m.db.get_db_value(Register.NO_INPUTS, 0)
|
||||
assert 'TSOL-MS1600' == m.db.get_db_value(Register.EQUIPMENT_MODEL, 0)
|
||||
m.close()
|
||||
|
||||
@@ -1500,6 +1502,7 @@ async def test_build_modell_1800(my_loop, config_tsun_allow_all, inverter_ind_ms
|
||||
m.read() # read complete msg, and dispatch msg
|
||||
assert 1800 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
|
||||
assert 1800 == m.db.get_db_value(Register.RATED_POWER, 0)
|
||||
assert 4 == m.db.get_db_value(Register.NO_INPUTS, 0)
|
||||
assert 'TSOL-MS1800' == m.db.get_db_value(Register.EQUIPMENT_MODEL, 0)
|
||||
m.close()
|
||||
|
||||
@@ -1513,6 +1516,7 @@ async def test_build_modell_2000(my_loop, config_tsun_allow_all, inverter_ind_ms
|
||||
m.read() # read complete msg, and dispatch msg
|
||||
assert 2000 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
|
||||
assert 2000 == m.db.get_db_value(Register.RATED_POWER, 0)
|
||||
assert 4 == m.db.get_db_value(Register.NO_INPUTS, 0)
|
||||
assert 'TSOL-MS2000' == m.db.get_db_value(Register.EQUIPMENT_MODEL, 0)
|
||||
m.close()
|
||||
|
||||
@@ -1526,6 +1530,7 @@ async def test_build_modell_800(my_loop, config_tsun_allow_all, inverter_ind_msg
|
||||
m.read() # read complete msg, and dispatch msg
|
||||
assert 800 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
|
||||
assert 800 == m.db.get_db_value(Register.RATED_POWER, 0)
|
||||
assert 2 == m.db.get_db_value(Register.NO_INPUTS, 0)
|
||||
assert 'TSOL-MS800' == m.db.get_db_value(Register.EQUIPMENT_MODEL, 0)
|
||||
m.close()
|
||||
|
||||
@@ -1539,6 +1544,7 @@ async def test_build_modell_900(my_loop, config_tsun_allow_all, inverter_ind_msg
|
||||
m.read() # read complete msg, and dispatch msg
|
||||
assert 900 == m.db.get_db_value(Register.MAX_DESIGNED_POWER, 0)
|
||||
assert 900 == m.db.get_db_value(Register.RATED_POWER, 0)
|
||||
assert 2 == m.db.get_db_value(Register.NO_INPUTS, 0)
|
||||
assert 'TSOL-MSxx00' == m.db.get_db_value(Register.EQUIPMENT_MODEL, 0)
|
||||
m.close()
|
||||
|
||||
@@ -2588,6 +2594,7 @@ async def test_proxy_dcu_cmd(my_loop, config_tsun_dcu1, patch_open_connection, d
|
||||
assert l.db.stat['proxy']['AT_Command'] == 0
|
||||
assert l.db.stat['proxy']['AT_Command_Blocked'] == 0
|
||||
assert l.db.stat['proxy']['Modbus_Command'] == 0
|
||||
assert 2 == l.db.get_db_value(Register.NO_INPUTS, 0)
|
||||
|
||||
l.append_msg(dcu_command_rsp_msg)
|
||||
l.read() # read at resp
|
||||
|
||||
Reference in New Issue