S allius/issue281 (#282)
* accept DCU serial number starting with '410' * determine sensor-list by serial number * adapt unit test for DCU support * send first batterie measurements to home assistant * add test case for sensor-list==3036 * add more registers for batteries * improve error logging (Monitoring SN) * update the add-on repro only for one stage * add configuration for energie storages * add License and Readme file to the add-on * addon: add date and time to dev and debug docker container tag * disable duplicate code check for config.py * cleanup unit test, remove trailing whitespaces * update changelog * fix example config for batteries * cleanup config.jinja template * fix comments * improve help texts
This commit is contained in:
@@ -76,7 +76,7 @@ def ConfigDefault():
|
||||
'type': 'RSM40-8-395M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-395M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
},
|
||||
'Y170000000000001': {
|
||||
'modbus_polling': True,
|
||||
@@ -91,8 +91,21 @@ def ConfigDefault():
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv4': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
}
|
||||
},
|
||||
'batteries': {
|
||||
'4100000000000001': {
|
||||
'modbus_polling': True,
|
||||
'monitor_sn': 3000000000,
|
||||
'suggested_area': '',
|
||||
'node_id': '',
|
||||
'pv1': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 0,
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -140,6 +153,18 @@ def ConfigComplete():
|
||||
'type': 'type4'},
|
||||
'suggested_area': 'Garage2',
|
||||
'sensor_list': 688}
|
||||
},
|
||||
'batteries': {
|
||||
'4100000000000001': {
|
||||
'modbus_polling': True,
|
||||
'monitor_sn': 3000000000,
|
||||
'suggested_area': 'Garage3',
|
||||
'node_id': 'Bat-Garage3/',
|
||||
'pv1': {'manufacturer': 'man5',
|
||||
'type': 'type5'},
|
||||
'pv2': {'manufacturer': 'man6',
|
||||
'type': 'type6'},
|
||||
'sensor_list': 12326}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -147,6 +172,19 @@ def test_default_config():
|
||||
Config.init(ConfigReadToml("app/src/cnf/default_config.toml"))
|
||||
validated = Config.def_config
|
||||
assert validated == {'gen3plus': {'at_acl': {'mqtt': {'allow': ['AT+'], 'block': []}, 'tsun': {'allow': ['AT+Z', 'AT+UPURL', 'AT+SUPDATE'], 'block': []}}}, 'tsun': {'enabled': True, 'host': 'logger.talent-monitoring.com', 'port': 5005}, 'solarman': {'enabled': True, 'host': 'iot.talent-monitoring.com', 'port': 10000}, 'mqtt': {'host': 'mqtt', 'port': 1883, 'user': None, 'passwd': None}, 'ha': {'auto_conf_prefix': 'homeassistant', 'discovery_prefix': 'homeassistant', 'entity_prefix': 'tsun', 'proxy_node_id': 'proxy', 'proxy_unique_id': 'P170000000000001'},
|
||||
'batteries': {
|
||||
'4100000000000001': {
|
||||
'modbus_polling': True,
|
||||
'monitor_sn': 3000000000,
|
||||
'node_id': '',
|
||||
'pv1': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 0,
|
||||
'suggested_area': ''
|
||||
}
|
||||
},
|
||||
'inverters': {
|
||||
'allow_all': False,
|
||||
'R170000000000001': {
|
||||
@@ -158,7 +196,7 @@ def test_default_config():
|
||||
'modbus_polling': False,
|
||||
'monitor_sn': 0,
|
||||
'suggested_area': '',
|
||||
'sensor_list': 688},
|
||||
'sensor_list': 0},
|
||||
'Y170000000000001': {
|
||||
'modbus_polling': True,
|
||||
'monitor_sn': 2000000000,
|
||||
@@ -172,7 +210,7 @@ def test_default_config():
|
||||
'pv4': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'suggested_area': '',
|
||||
'sensor_list': 688}}}
|
||||
'sensor_list': 0}}}
|
||||
|
||||
def test_full_config(ConfigComplete):
|
||||
cnf = {'tsun': {'enabled': True, 'host': 'logger.talent-monitoring.com', 'port': 5005},
|
||||
@@ -181,9 +219,14 @@ def test_full_config(ConfigComplete):
|
||||
'solarman': {'enabled': True, 'host': 'iot.talent-monitoring.com', 'port': 10000},
|
||||
'mqtt': {'host': 'mqtt', 'port': 1883, 'user': '', 'passwd': ''},
|
||||
'ha': {'auto_conf_prefix': 'homeassistant', 'discovery_prefix': 'homeassistant', 'entity_prefix': 'tsun', 'proxy_node_id': 'proxy', 'proxy_unique_id': 'P170000000000001'},
|
||||
'batteries': {
|
||||
'4100000000000001': {'modbus_polling': True, 'monitor_sn': 3000000000, 'node_id': 'Bat-Garage3/', 'sensor_list': 0x3026, 'suggested_area': 'Garage3', 'pv1': {'type': 'type5', 'manufacturer': 'man5'}, 'pv2': {'type': 'type6', 'manufacturer': 'man6'}}
|
||||
},
|
||||
'inverters': {'allow_all': False,
|
||||
'R170000000000001': {'modbus_polling': False, 'node_id': 'PV-Garage/', 'sensor_list': 0x02B0, 'suggested_area': 'Garage', 'pv1': {'type': 'type1', 'manufacturer': 'man1'}, 'pv2': {'type': 'type2', 'manufacturer': 'man2'}},
|
||||
'Y170000000000001': {'modbus_polling': True, 'monitor_sn': 2000000000, 'node_id': 'PV-Garage2/', 'sensor_list': 0x02B0, 'suggested_area': 'Garage2', 'pv1': {'type': 'type1', 'manufacturer': 'man1'}, 'pv2': {'type': 'type2', 'manufacturer': 'man2'}, 'pv3': {'type': 'type3', 'manufacturer': 'man3'}, 'pv4': {'type': 'type4', 'manufacturer': 'man4'}}}}
|
||||
'Y170000000000001': {'modbus_polling': True, 'monitor_sn': 2000000000, 'node_id': 'PV-Garage2/', 'sensor_list': 0x02B0, 'suggested_area': 'Garage2', 'pv1': {'type': 'type1', 'manufacturer': 'man1'}, 'pv2': {'type': 'type2', 'manufacturer': 'man2'}, 'pv3': {'type': 'type3', 'manufacturer': 'man3'}, 'pv4': {'type': 'type4', 'manufacturer': 'man4'}}
|
||||
}
|
||||
}
|
||||
try:
|
||||
validated = Config.conf_schema.validate(cnf)
|
||||
except Exception:
|
||||
@@ -240,6 +283,19 @@ def test_read_cnf1():
|
||||
assert err == None
|
||||
cnf = Config.get()
|
||||
assert cnf == {'gen3plus': {'at_acl': {'mqtt': {'allow': ['AT+'], 'block': []}, 'tsun': {'allow': ['AT+Z', 'AT+UPURL', 'AT+SUPDATE'], 'block': []}}}, 'tsun': {'enabled': True, 'host': 'logger.talent-monitoring.com', 'port': 5005}, 'solarman': {'enabled': False, 'host': 'iot.talent-monitoring.com', 'port': 10000}, 'mqtt': {'host': 'mqtt', 'port': 1883, 'user': None, 'passwd': None}, 'ha': {'auto_conf_prefix': 'homeassistant', 'discovery_prefix': 'homeassistant', 'entity_prefix': 'tsun', 'proxy_node_id': 'proxy', 'proxy_unique_id': 'P170000000000001'},
|
||||
'batteries': {
|
||||
'4100000000000001': {
|
||||
'modbus_polling': True,
|
||||
'monitor_sn': 3000000000,
|
||||
'node_id': '',
|
||||
'pv1': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 0,
|
||||
'suggested_area': ''
|
||||
}
|
||||
},
|
||||
'inverters': {
|
||||
'allow_all': False,
|
||||
'R170000000000001': {
|
||||
@@ -251,7 +307,7 @@ def test_read_cnf1():
|
||||
'type': 'RSM40-8-395M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-395M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
},
|
||||
'Y170000000000001': {
|
||||
'modbus_polling': True,
|
||||
@@ -266,7 +322,7 @@ def test_read_cnf1():
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv4': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -287,6 +343,19 @@ def test_read_cnf2():
|
||||
assert err == None
|
||||
cnf = Config.get()
|
||||
assert cnf == {'gen3plus': {'at_acl': {'mqtt': {'allow': ['AT+'], 'block': []}, 'tsun': {'allow': ['AT+Z', 'AT+UPURL', 'AT+SUPDATE'], 'block': []}}}, 'tsun': {'enabled': True, 'host': 'logger.talent-monitoring.com', 'port': 5005}, 'solarman': {'enabled': True, 'host': 'iot.talent-monitoring.com', 'port': 10000}, 'mqtt': {'host': 'mqtt', 'port': 1883, 'user': None, 'passwd': None}, 'ha': {'auto_conf_prefix': 'homeassistant', 'discovery_prefix': 'homeassistant', 'entity_prefix': 'tsun', 'proxy_node_id': 'proxy', 'proxy_unique_id': 'P170000000000001'},
|
||||
'batteries': {
|
||||
'4100000000000001': {
|
||||
'modbus_polling': True,
|
||||
'monitor_sn': 3000000000,
|
||||
'node_id': '',
|
||||
'pv1': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 0,
|
||||
'suggested_area': ''
|
||||
}
|
||||
},
|
||||
'inverters': {
|
||||
'allow_all': False,
|
||||
'R170000000000001': {
|
||||
@@ -298,7 +367,7 @@ def test_read_cnf2():
|
||||
'type': 'RSM40-8-395M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-395M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
},
|
||||
'Y170000000000001': {
|
||||
'modbus_polling': True,
|
||||
@@ -313,7 +382,7 @@ def test_read_cnf2():
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv4': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -342,6 +411,19 @@ def test_read_cnf4():
|
||||
assert err == None
|
||||
cnf = Config.get()
|
||||
assert cnf == {'gen3plus': {'at_acl': {'mqtt': {'allow': ['AT+'], 'block': []}, 'tsun': {'allow': ['AT+Z', 'AT+UPURL', 'AT+SUPDATE'], 'block': []}}}, 'tsun': {'enabled': True, 'host': 'logger.talent-monitoring.com', 'port': 5005}, 'solarman': {'enabled': True, 'host': 'iot.talent-monitoring.com', 'port': 5000}, 'mqtt': {'host': 'mqtt', 'port': 1883, 'user': None, 'passwd': None}, 'ha': {'auto_conf_prefix': 'homeassistant', 'discovery_prefix': 'homeassistant', 'entity_prefix': 'tsun', 'proxy_node_id': 'proxy', 'proxy_unique_id': 'P170000000000001'},
|
||||
'batteries': {
|
||||
'4100000000000001': {
|
||||
'modbus_polling': True,
|
||||
'monitor_sn': 3000000000,
|
||||
'node_id': '',
|
||||
'pv1': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 0,
|
||||
'suggested_area': ''
|
||||
}
|
||||
},
|
||||
'inverters': {
|
||||
'allow_all': False,
|
||||
'R170000000000001': {
|
||||
@@ -353,7 +435,7 @@ def test_read_cnf4():
|
||||
'type': 'RSM40-8-395M'},
|
||||
'pv2': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-395M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
},
|
||||
'Y170000000000001': {
|
||||
'modbus_polling': True,
|
||||
@@ -368,7 +450,7 @@ def test_read_cnf4():
|
||||
'type': 'RSM40-8-410M'},
|
||||
'pv4': {'manufacturer': 'Risen',
|
||||
'type': 'RSM40-8-410M'},
|
||||
'sensor_list': 688
|
||||
'sensor_list': 0
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user