S allius/issue281 (#282)
* accept DCU serial number starting with '410' * determine sensor-list by serial number * adapt unit test for DCU support * send first batterie measurements to home assistant * add test case for sensor-list==3036 * add more registers for batteries * improve error logging (Monitoring SN) * update the add-on repro only for one stage * add configuration for energie storages * add License and Readme file to the add-on * addon: add date and time to dev and debug docker container tag * disable duplicate code check for config.py * cleanup unit test, remove trailing whitespaces * update changelog * fix example config for batteries * cleanup config.jinja template * fix comments * improve help texts
This commit is contained in:
@@ -121,6 +121,32 @@ class Register(Enum):
|
||||
TS_INPUT = 600
|
||||
TS_GRID = 601
|
||||
TS_TOTAL = 602
|
||||
BATT_PV1_VOLT = 1000
|
||||
BATT_PV1_CUR = 1001
|
||||
BATT_PV2_VOLT = 1002
|
||||
BATT_PV2_CUR = 1003
|
||||
BATT_38 = 1004
|
||||
BATT_3a = 1005
|
||||
BATT_3c = 1006
|
||||
BATT_3e = 1007
|
||||
BATT_40 = 1010
|
||||
BATT_42 = 1011
|
||||
BATT_SOC = 1012
|
||||
BATT_46 = 1013
|
||||
BATT_48 = 1014
|
||||
BATT_4a = 1015
|
||||
BATT_4c = 1016
|
||||
BATT_4e = 1017
|
||||
BATT_66 = 1018
|
||||
BATT_68 = 1019
|
||||
BATT_6a = 1020
|
||||
BATT_6c = 1021
|
||||
BATT_6e = 1022
|
||||
BATT_70 = 1023
|
||||
BATT_72 = 1024
|
||||
BATT_74 = 1025
|
||||
BATT_76 = 1026
|
||||
BATT_78 = 1027
|
||||
VALUE_1 = 9000
|
||||
TEST_REG1 = 10000
|
||||
TEST_REG2 = 10001
|
||||
@@ -266,6 +292,7 @@ class Infos:
|
||||
__info_devs = {
|
||||
'proxy': {'singleton': True, 'name': 'Proxy', 'mf': 'Stefan Allius'}, # noqa: E501
|
||||
'controller': {'via': 'proxy', 'name': 'Controller', 'mdl': Register.CHIP_MODEL, 'mf': Register.CHIP_TYPE, 'sw': Register.COLLECTOR_FW_VERSION, 'mac': Register.MAC_ADDR, 'sn': Register.COLLECTOR_SNR}, # noqa: E501
|
||||
|
||||
'inverter': {'via': 'controller', 'name': 'Micro Inverter', 'mdl': Register.EQUIPMENT_MODEL, 'mf': Register.MANUFACTURER, 'sw': Register.VERSION, 'sn': Register.SERIAL_NUMBER}, # noqa: E501
|
||||
'input_pv1': {'via': 'inverter', 'name': 'Module PV1', 'mdl': Register.PV1_MODEL, 'mf': Register.PV1_MANUFACTURER}, # noqa: E501
|
||||
'input_pv2': {'via': 'inverter', 'name': 'Module PV2', 'mdl': Register.PV2_MODEL, 'mf': Register.PV2_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 2}}, # noqa: E501
|
||||
@@ -273,6 +300,10 @@ class Infos:
|
||||
'input_pv4': {'via': 'inverter', 'name': 'Module PV4', 'mdl': Register.PV4_MODEL, 'mf': Register.PV4_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 4}}, # noqa: E501
|
||||
'input_pv5': {'via': 'inverter', 'name': 'Module PV5', 'mdl': Register.PV5_MODEL, 'mf': Register.PV5_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 5}}, # noqa: E501
|
||||
'input_pv6': {'via': 'inverter', 'name': 'Module PV6', 'mdl': Register.PV6_MODEL, 'mf': Register.PV6_MANUFACTURER, 'dep': {'reg': Register.NO_INPUTS, 'gte': 6}}, # noqa: E501
|
||||
|
||||
'batterie': {'via': 'controller', 'name': 'Batterie', 'mdl': Register.EQUIPMENT_MODEL, 'mf': Register.MANUFACTURER, 'sw': Register.VERSION, 'sn': Register.SERIAL_NUMBER}, # noqa: E501
|
||||
'bat_inp_pv1': {'via': 'batterie', 'name': 'Module PV1', 'mdl': Register.PV1_MODEL, 'mf': Register.PV1_MANUFACTURER}, # noqa: E501
|
||||
'bat_inp_pv2': {'via': 'batterie', 'name': 'Module PV2', 'mdl': Register.PV2_MODEL, 'mf': Register.PV2_MANUFACTURER}, # noqa: E501
|
||||
}
|
||||
|
||||
__comm_type_val_tpl = "{%set com_types = ['n/a','Wi-Fi', 'G4', 'G5', 'GPRS'] %}{{com_types[value_json['Communication_Type']|int(0)]|default(value_json['Communication_Type'])}}" # noqa: E501
|
||||
@@ -518,15 +549,15 @@ class Infos:
|
||||
Register.TOTAL_GENERATION: {'name': ['total', 'Total_Generation'], 'level': logging.INFO, 'unit': 'kWh', 'ha': {'dev': 'inverter', 'dev_cla': 'energy', 'stat_cla': 'total', 'id': 'total_gen_', 'fmt': FMT_FLOAT, 'name': TOTAL_GEN, 'icon': SOLAR_POWER, 'must_incr': True}}, # noqa: E501
|
||||
|
||||
# controller:
|
||||
Register.SIGNAL_STRENGTH: {'name': ['controller', 'Signal_Strength'], 'level': logging.DEBUG, 'unit': '%', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'signal_', 'fmt': FMT_INT, 'name': 'Signal Strength', 'icon': WIFI}}, # noqa: E501
|
||||
Register.POWER_ON_TIME: {'name': ['controller', 'Power_On_Time'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': 'duration', 'stat_cla': 'measurement', 'id': 'power_on_time_', 'fmt': FMT_INT, 'name': 'Power on Time', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.COLLECT_INTERVAL: {'name': ['controller', 'Collect_Interval'], 'level': logging.DEBUG, 'unit': 'min', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_collect_intval_', 'fmt': '| string + " min"', 'name': 'Data Collect Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.CONNECT_COUNT: {'name': ['controller', 'Connect_Count'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'connect_count_', 'fmt': FMT_INT, 'name': 'Connect Count', 'icon': COUNTER, 'comp': 'sensor', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.COMMUNICATION_TYPE: {'name': ['controller', 'Communication_Type'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'comm_type_', 'name': 'Communication Type', 'val_tpl': __comm_type_val_tpl, 'comp': 'sensor', 'icon': WIFI}}, # noqa: E501
|
||||
Register.DATA_UP_INTERVAL: {'name': ['controller', 'Data_Up_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_up_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Data Up Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.HEARTBEAT_INTERVAL: {'name': ['controller', 'Heartbeat_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'heartbeat_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Heartbeat Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.IP_ADDRESS: {'name': ['controller', 'IP_Address'], 'level': logging.DEBUG, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'ip_address_', 'fmt': '| string', 'name': 'IP Address', 'icon': WIFI, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.POLLING_INTERVAL: {'name': ['controller', 'Polling_Interval'], 'level': logging.DEBUG, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'polling_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Polling Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.SIGNAL_STRENGTH: {'name': ['controller', 'Signal_Strength'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'signal_', 'fmt': FMT_INT, 'name': 'Signal Strength', 'icon': WIFI}}, # noqa: E501
|
||||
Register.POWER_ON_TIME: {'name': ['controller', 'Power_On_Time'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': 'duration', 'stat_cla': 'measurement', 'id': 'power_on_time_', 'fmt': FMT_INT, 'name': 'Power on Time', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.COLLECT_INTERVAL: {'name': ['controller', 'Collect_Interval'], 'level': logging.INFO, 'unit': 'min', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_collect_intval_', 'fmt': '| string + " min"', 'name': 'Data Collect Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.CONNECT_COUNT: {'name': ['controller', 'Connect_Count'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'connect_count_', 'fmt': FMT_INT, 'name': 'Connect Count', 'icon': COUNTER, 'comp': 'sensor', 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.COMMUNICATION_TYPE: {'name': ['controller', 'Communication_Type'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'comm_type_', 'name': 'Communication Type', 'val_tpl': __comm_type_val_tpl, 'comp': 'sensor', 'icon': WIFI}}, # noqa: E501
|
||||
Register.DATA_UP_INTERVAL: {'name': ['controller', 'Data_Up_Interval'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'data_up_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Data Up Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.HEARTBEAT_INTERVAL: {'name': ['controller', 'Heartbeat_Interval'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'heartbeat_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Heartbeat Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.IP_ADDRESS: {'name': ['controller', 'IP_Address'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'ip_address_', 'fmt': '| string', 'name': 'IP Address', 'icon': WIFI, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.POLLING_INTERVAL: {'name': ['controller', 'Polling_Interval'], 'level': logging.INFO, 'unit': 's', 'ha': {'dev': 'controller', 'dev_cla': None, 'stat_cla': None, 'id': 'polling_intval_', 'fmt': FMT_STRING_SEC, 'name': 'Polling Interval', 'icon': UPDATE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.SENSOR_LIST: {'name': ['controller', 'Sensor_List'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
||||
Register.SSID: {'name': ['controller', 'WiFi_SSID'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
|
||||
@@ -536,6 +567,33 @@ class Infos:
|
||||
Register.PROD_COMPL_TYPE: {'name': ['other', 'Prod_Compliance_Type'], 'level': logging.INFO, 'unit': ''}, # noqa: E501
|
||||
Register.INV_UNKNOWN_1: {'name': ['inv_unknown', 'Unknown_1'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
|
||||
|
||||
Register.BATT_PV1_VOLT: {'name': ['batterie', 'pv1', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv1_', 'val_tpl': "{{ (value_json['pv1']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV1_CUR: {'name': ['batterie', 'pv1', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv1', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv1_', 'val_tpl': "{{ (value_json['pv1']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV2_VOLT: {'name': ['batterie', 'pv2', 'Voltage'], 'level': logging.INFO, 'unit': 'V', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'voltage', 'stat_cla': 'measurement', 'id': 'volt_pv2_', 'val_tpl': "{{ (value_json['pv2']['Voltage'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_PV2_CUR: {'name': ['batterie', 'pv2', 'Current'], 'level': logging.INFO, 'unit': 'A', 'ha': {'dev': 'bat_inp_pv2', 'dev_cla': 'current', 'stat_cla': 'measurement', 'id': 'cur_pv2_', 'val_tpl': "{{ (value_json['pv2']['Current'] | float)}}", 'icon': GAUGE, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_38: {'name': ['batterie', 'Reg_38'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_38_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_3a: {'name': ['batterie', 'Reg_3a'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_3a_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_3c: {'name': ['batterie', 'Reg_3c'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_3c_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_3e: {'name': ['batterie', 'Reg_3e'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_3e_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_40: {'name': ['batterie', 'Reg_40'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_40_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_42: {'name': ['batterie', 'Reg_42'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_42_', 'fmt': FMT_FLOAT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_SOC: {'name': ['batterie', 'SOC'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'batterie', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'soc_', 'fmt': FMT_FLOAT, 'name': 'State of Charge', 'icon': 'mdi:battery-90'}}, # noqa: E501
|
||||
# Register.BATT_46: {'name': ['batterie', 'Reg_46'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_46_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
# Register.BATT_48: {'name': ['batterie', 'Reg_48'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_48_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
# Register.BATT_4a: {'name': ['batterie', 'Reg_4a'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_4a_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
# Register.BATT_4c: {'name': ['batterie', 'Reg_4c'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_4c_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
# Register.BATT_4e: {'name': ['batterie', 'Reg_4e'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_4e_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
|
||||
Register.BATT_66: {'name': ['batterie', 'Reg_66'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_66_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_68: {'name': ['batterie', 'Reg_68'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_68_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_6a: {'name': ['batterie', 'Reg_6a'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_6a_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_6c: {'name': ['batterie', 'Reg_6c'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_6c_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_6e: {'name': ['batterie', 'Reg_6e'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_6e_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_70: {'name': ['batterie', 'Reg_70'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_70_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_72: {'name': ['batterie', 'Reg_72'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_72_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_74: {'name': ['batterie', 'Reg_74'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_74_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_76: {'name': ['batterie', 'Reg_76'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_76_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
Register.BATT_78: {'name': ['batterie', 'Reg_78'], 'level': logging.INFO, 'unit': '', 'ha': {'dev': 'batterie', 'dev_cla': 'power', 'stat_cla': 'measurement', 'id': 'batt_78_', 'fmt': FMT_INT, 'ent_cat': 'diagnostic'}}, # noqa: E501
|
||||
}
|
||||
|
||||
@property
|
||||
|
||||
Reference in New Issue
Block a user