S allius/issue281 (#282)

* accept DCU serial number starting with '410'

* determine sensor-list by serial number

* adapt unit test for DCU support

* send first batterie measurements to home assistant

* add test case for sensor-list==3036

* add more registers for batteries

* improve error logging (Monitoring SN)

* update the add-on repro only for one stage

* add configuration for energie storages

* add License and Readme file to the add-on

* addon: add date and time to dev and debug docker container tag

* disable duplicate code check for config.py

* cleanup unit test, remove trailing whitespaces

* update changelog

* fix example config for batteries

* cleanup config.jinja template

* fix comments

* improve help texts
This commit is contained in:
Stefan Allius
2025-02-24 22:39:34 +01:00
committed by GitHub
parent 1f0ac97368
commit 036dd6d1dc
24 changed files with 691 additions and 132 deletions

View File

@@ -2,6 +2,7 @@ import struct
import logging
import time
import asyncio
from itertools import chain
from datetime import datetime
from async_ifc import AsyncIfc
@@ -376,12 +377,23 @@ class SolarmanV5(SolarmanBase):
self.ifc.fwd_add(build_msg)
self.ifc.fwd_add(struct.pack('<BB', 0, 0x15)) # crc & stop
def __set_config_parms(self, inv: dict):
def __set_config_parms(self, inv: dict, serial_no: str):
'''init connection with params from the configuration'''
self.node_id = inv['node_id']
self.sug_area = inv['suggested_area']
self.modbus_polling = inv['modbus_polling']
self.sensor_list = inv['sensor_list']
if 0 == self.sensor_list:
snr = serial_no[:3]
if '410' == snr:
self.sensor_list = 0x3026
else:
self.sensor_list = 0x02b0
self.db.set_db_def_value(Register.SENSOR_LIST,
f"{self.sensor_list:04x}")
logging.debug(f"Use sensor-list: {self.sensor_list:#04x}"
f" for '{serial_no}'")
if self.mb:
self.mb.set_node_id(self.node_id)
@@ -392,13 +404,14 @@ class SolarmanV5(SolarmanBase):
logger.debug(f'SerialNo: {serial_no}')
else:
inverters = Config.get('inverters')
batteries = Config.get('batteries')
# logger.debug(f'Inverters: {inverters}')
for key, inv in inverters.items():
for key, inv in chain(inverters.items(), batteries.items()):
# logger.debug(f'key: {key} -> {inv}')
if (type(inv) is dict and 'monitor_sn' in inv
and inv['monitor_sn'] == snr):
self.__set_config_parms(inv)
self.__set_config_parms(inv, key)
self.db.set_pv_module_details(inv)
logger.debug(f'SerialNo {serial_no} allowed! area:{self.sug_area}') # noqa: E501
@@ -411,9 +424,11 @@ class SolarmanV5(SolarmanBase):
if 'allow_all' not in inverters or not inverters['allow_all']:
self.inc_counter('Unknown_SNR')
self.unique_id = None
logger.warning(f'ignore message from unknow inverter! (SerialNo: {serial_no})') # noqa: E501
logging.error(f"Ignore message from unknow inverter with Monitoring-SN: {serial_no})!\n" # noqa: E501
" !!Check the 'monitor_sn' setting in your configuration!!") # noqa: E501
return
logger.warning(f'SerialNo {serial_no} not known but accepted!')
logging.warning(f"Monitoring-SN: {serial_no} not configured but accepted!" # noqa: E501
" !!Check the 'monitor_sn' setting in your configuration!!") # noqa: E501
self.unique_id = serial_no
@@ -460,11 +475,11 @@ class SolarmanV5(SolarmanBase):
def mb_timout_cb(self, exp_cnt):
self.mb_timer.start(self.mb_timeout)
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.DEBUG)
self._send_modbus_cmd(Modbus.READ_REGS, 0x3000, 48, logging.INFO)
if 1 == (exp_cnt % 30):
# logging.info("Regular Modbus Status request")
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.DEBUG)
self._send_modbus_cmd(Modbus.READ_REGS, 0x2000, 96, logging.INFO)
def at_cmd_forbidden(self, cmd: str, connection: str) -> bool:
return not cmd.startswith(tuple(self.at_acl[connection]['allow'])) or \